The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The Advantages of Wearable Green Reflected Photoplethysmography
Abstract
This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Mio Alpha's PPG technology was previously validated against a standard electrocardiogram (ECG) (Maeda, Sekine, Tamura, 2011a)”
From Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance (2017) · cites this paper as Maeda, Sekine, Tamura, 2011a
In the citing paper
“Green is preferred to red and infrared since this wavelength does not penetrate deep into tissue causing fewer artifacts from a non-pulsatile slow-changing component [55].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [55]
In the citing paper
“Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter [30,80,102].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [102]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Pulsed multifrequency photoplethysmograph
Giltvedt, J., Sira, A., & Helme, P. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442745 · Cited by 47
Green Light Photoplethysmography Monitoring of Free Flaps
Futran, N. D., Stack, B. C., Hollenbeak, C. S., & Scharf, J. (2000) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.126.5.659 · Cited by 35
Cited by
Sorted by citations
Items 101–200 of 209
Tun, H. M. (2021) · International Journal of Electrical and Electronic Engineering & Telecommunications · doi:10.18178/ijeetc.10.4.272-282 · Cited by 14
Estimation of HbA1c level among diabetic patients using second derivative of Photoplethysmography
Usman, S., Harun, N., Dziyauddin, R. A., & Bani, N. A. (2017) · IEEE Student Conference on Research and Development (SCOReD) · doi:10.1109/scored.2017.8305415 · Cited by 14
Polarizer-free polarimetric organic photodetectors for enhanced signal monitoring
Hwang, H., Um, H.-K., Ahn, H., Cho, S., Lee, J., & Lee, B. H. (2024) · Device · doi:10.1016/j.device.2024.100613 · Cited by 12
Bioelectronic devices for light-based diagnostics and therapies
Kim, H., Sritandi, W., Xiong, Z., & Ho, J. S. (2023) · Biophysics Reviews · doi:10.1063/5.0102811 · Cited by 12
Multi-spectral photoplethysmography biosensor
Asare, L., Kviesis-Kipge, E., Grabovskis, A., Rubīns, U., Spīgulis, J., & Erts, R. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.887176 · Cited by 13
Montes, J., Tandy, R. D., Young, J., Lee, S., & Navalta, J. W. (2019) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.7n.2p.30 · Cited by 10
Multipoint Tissue Circulation Monitoring with a Flexible Optical Probe
Tomioka, Y., Enomoto, S., Gu, J., Kaneko, A., Saito, I., Inoue, Y., Woo, T., Koshima, I., Yoshimura, K., Someya, T., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10115-5 · Cited by 11
Examining the Accuracy of the Polar A360 Monitor
Rider, B. C., Conger, S. A., Ditzenberger, G. L., Besteman, S. S., Bouret, C. M., & Coughlin, A. M. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003136 · Cited by 10
Heart rate monitoring by using non-invasive wearable sensor
Maria, A. R., Pasca, S., & Strungaru, R. (2017) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb.2017.7995492 · Cited by 10
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10
A Rare Case of Ciprofloxacin-Induced Bradycardia Recognized by a Smartwatch
Sanchez, A. M. C., Chohan, M. R., Olatunde, O., & White, C. (2022) · Journal of Investigative Medicine High Impact Case Reports · doi:10.1177/23247096211069761 · Cited by 11
Acevedo, R. U., Sánchez, L. O., Londoño, S. V., Mejía‐Mejía, E., Villa, R. T., & Montoya, Y. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.1.017001 · Cited by 9
Liu, I., Liu, F., Zhong, Q., & Ni, S. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01365-w · Cited by 13
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2023) · Sensors · doi:10.3390/s23146628 · Cited by 9
Multifunctional Photoplethysmography Sensor Design for Respiratory and Cardiovascular Diagnosis
Uguz, D. U., Venema, B., Leonhardt, S. K., & Teichmann, D. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_167 · Cited by 9
Demonstrating the Applicability of Smartwatches in PM2.5 Health Impact Assessment
Tsou, M. M., Lung, S. C., & Cheng, C.-H. C. (2021) · Sensors · doi:10.3390/s21134585 · Cited by 9
Design of a Wearable Finger PPG-Based Blood Glucose Monitor
Wang, M., Liu, X., Han, W., Lin, X., Chen, X., Zhao, S., Zhuang, Z., Zhang, L., & Su, P. (2025) · Annals of Biomedical Engineering · doi:10.1007/s10439-025-03809-9 · Cited by 8
Multi-wavelength SPAD photoplethysmography for cardio-respiratory monitoring
Cusini, I., Rinaldi, R., Castiglioni, P., Faini, A., & Villa, F. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.952103 · Cited by 8
Physiological origin of camera-based PPG imaging
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00010-x · Cited by 8
Akishin, A. D., Николаев, А. П., & Pisareva, A. V. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2096/1/012187 · Cited by 7
Development of telemedicine tools with an emphasis on visual observation
Takahashi, M., Koike, R., Nagasawa, K., Manabe, Y., Hirana, H., Takamura, M., Hongawa, T., Kimoto, I., Ogawa‐Ochiai, K., & Tsumura, N. (2022) · Artificial Life and Robotics · doi:10.1007/s10015-022-00731-4 · Cited by 8
Comparison and convergence of compartment syndrome techniques: a narrative review
Sharma, N., Sharma, N. M., Sharma, A., & Mirza, S. (2023) · Expert Review of Medical Devices · doi:10.1080/17434440.2023.2206020 · Cited by 8
Kido, K., Chen, Z., Huang, M., TAMURA, T., Chen, W., Ono, N., Takeuchi, M., Altaf‐Ul‐Amin, M., & Kanaya, S. (2021) · Life · doi:10.3390/life12010011 · Cited by 9
Self-citationYan, L., Long, Z., Qian, J., Lin, J., Xie, S. Q., & Sheng, B. (2024) · Sensors · doi:10.3390/s24092925 · Cited by 9
Zhong, Y., Zhang, Y., Pu, J., Wustoni, S., Uribe, J., Lopez‐Larrea, N., Marks, A., McCulloch, I. A., Mecerreyes, D., Baran, D., et al. (2025) · Device · doi:10.1016/j.device.2025.100778 · Cited by 7
Wearable health monitoring system based on self-powered Bi-based perovskite photodetector
Ren, H., Li, Y., Chen, Y., Wei, R., Kuang, D., Wei, Z., & Shen, G. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.111835 · Cited by 8
TAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 11
Self-citationImaging photoplethysmography and its applications
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00014-1 · Cited by 7
A Practical Approach to Health Status Monitoring Based on Heart Rate and Respiratory Rate Assessment
Ribeiro, G., Postolache, O. A., & Ferrero, F. J. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856576 · Cited by 7
Yoshioka, M., Murakami, K., & Ozawa, J. (2015) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2015.7280486 · Cited by 7
Vorreuther, A., Tagalidou, N., & Vukelić, M. (2025) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2025.1585469 · Cited by 10
Pulse rate variability analysis by video using face detection and tracking algorithms
Rodríguez, A., & Ramos-Castro, J. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319685 · Cited by 7
Development of wearable optical-based fibre sensor system for pulse transit time measurement
Zaki, W. S. W., Correia, R. G., Korposh, S., Hayes‐Gill, B., & Morgan, S. P. (2020) · AIP conference proceedings · doi:10.1063/1.5142105 · Cited by 6
TAMURA, T. (2020) · Advanced Biomedical Engineering · doi:10.14326/abe.9.189 · Cited by 6
Self-citationPark, T. S., Kim, M., Park, J., Hong, J.-M., Lee, D., Han, I. H., & Shin, M. (2025) · Healthcare · doi:10.3390/healthcare13182346 · Cited by 5
Baciu, V.-E., Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2023) · Sensors · doi:10.3390/s23156947 · Cited by 5
Regalia, G., Resnati, D., & Tognetti, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00130-8 · Cited by 9
Le, V. N. D., Fronckowiak, S., & Badolato, E. (2025) · Sensors · doi:10.3390/s25072311 · Cited by 5
Printing flexible two-dimensional indium tin oxide for multifunctional transparent bioelectrodes
Rahman, M. S., Ong, S. A., Tiwari, A. P., & Scheideler, W. J. (2025) · MRS Advances · doi:10.1557/s43580-025-01320-w · Cited by 4
Shcherbinin, A. V., Zaytsev, V. V., Nippolainen, E., Sokolov, A. Y., & Kamshilin, A. A. (2024) · Russian journal of neurosurgery · doi:10.17650/1683-3295-2024-26-3-43-56 · Cited by 4
Benchmarking of Sensor Configurations and Measurement Sites for Out-of-the-Lab Photoplethysmography
Supelnic, M. N., Ferreira, A. F., Bota, P. J., Rosário, L. B., & Silva, H. (2023) · Sensors · doi:10.3390/s24010214 · Cited by 4
Na, Y., Kim, C., Kim, K., Kim, T. H., Kwon, S. H., Kang, I., Jung, Y. W., Kim, T. W., Cho, D.-H., An, J., et al. (2024) · Biosensors · doi:10.3390/bios14020109 · Cited by 4
Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling
Yang, J., Zhi-hui, L., Li, X., Tao, K., & Qiu, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-00559-5 · Cited by 3
A comparative analysis of reflective and transmissive PPG sensor in pulse acquisition system
Sukesh Rao, M., Hegde, R. B., & Bangera, S. C. (2023) · International Conference on Computer, Electronics & Electrical Engineering & their Applications (IC2E3) · doi:10.1109/ic2e357697.2023.10262473 · Cited by 4
Improved peak detection technique for robust PPG-based heartrate monitoring system on smartphones
Lomaliza, J.-P., & Park, H. (2017) · Multimedia Tools and Applications · doi:10.1007/s11042-017-5282-9 · Cited by 4
Noninvasive Heart Rate and Respiration Rate Detection Enabled by Perovskite Single Crystal Detector
Chen, Y., Huang, L., Cui, Y., Ji, Y., Huang, Z., Liu, T., Liu, J., Ma, X., Tan, P., Hao, Y., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202516873 · Cited by 3
Multifunctional Wearable OLED−OPD System with Wavelength-Tunable Emission for Phototheranostics
Park, M., Lee, H. S., Cho, Y., Jeong, J., Lee, C., Jeong, S. Y., Kwon, S. J., Cho, E., & Jeon, Y. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04796 · Cited by 3
Reflective PPG-based noninvasive continuous pulse rate measurement and remote monitoring system
Mukherjee, R., Ghosh, S. P., Gupta, B., & Chakravarty, T. (2017) · Global Wireless Summit (GWS) · doi:10.1109/gws.2017.8300493 · Cited by 3
Validation of Cuffless Blood Pressure Monitoring Using Wearable Device
Baek, J., Kim, J., Kim, N., Lee, D., & Park, S. (2018) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2018.8650069 · Cited by 3
Chen, S.-Y., Lai, C., & Chang, C. (2019) · IEEE Access · doi:10.1109/access.2019.2940378 · Cited by 3
Feukeu, E. A., & Winberg, S. L. (2019) · International Multidisciplinary Information Technology and Engineering Conference (IMITEC) · doi:10.1109/imitec45504.2019.9015874 · Cited by 3
Tanaka, A. (2022) · IEICE Electronics Express · doi:10.1587/elex.19.20220371 · Cited by 3
Development and Testing of a Miniaturized Platform for Photoplethysmography
Traversi, G., Gaioni, L., & Salvetti, D. (2023) · Electronics · doi:10.3390/electronics12102230 · Cited by 3
Fawcett, A. (2018) · UWSpace (University of Waterloo) · Cited by 3
Sokolov, A. Y., Zaytsev, V. V., Shcherbinin, A. V., & Kamshilin, A. A. (2026) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545826400067 · Cited by 2
Sviridova, N., Zhao, T., Nakano, A., & Ikeguchi, T. (2022) · Sensors · doi:10.3390/s22145154 · Cited by 2
Noncontact Lie Detection System Involving Photoplethysmography and Heart Rate Variability
Chang, H.-C. (2023) · International Journal of Pattern Recognition and Artificial Intelligence · doi:10.1142/s0218001423500064 · Cited by 2
Schepanski, S. N., Batta, F., Schröter, M., Seifert, G., & Koch, A. K. (2025) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2025.1603700 · Cited by 2
Miyaji, T., Sviridova, N., Aihara, K., Zhao, T., & Nakano, A. (2019) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5088989 · Cited by 2
The Effects of Silicone Enclosure Colour on the Function of Optical Sensors
Frank, G., Askari, S., Raschdorf, K., Khosravi, S., Kwon, B. K., & Shadgan, B. (2022) · Biology · doi:10.3390/biology11060932 · Cited by 2
Volpes, G., Valenti, S., Parisi, A., Busacca, A., Faes, L., & Pernice, R. (2022) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon53508.2022.9842970 · Cited by 2
Hinatsu, S., Matsuda, N., Ishizuka, H., Ikeda, S., & Oshiro, O. (2022) · IEEE Access · doi:10.1109/access.2022.3221456 · Cited by 2
Sensing Technologies for Biomedical Telemetry
Tamura, T. (2014) · Wiley eBooks · doi:10.1002/9781118893715.ch4 · Cited by 2
Self-citationOptimal design of PPG sensor case geometry to improve sensitivity
Jang, J., & Yang, G. (2017) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2017.7992770 · Cited by 1
Evaluation of Cuffless Blood Pressure Estimation Accuracy of Different Light Colors
Nakagawa, M., Ebisuya, R., Hanada, K., Ishikawa, H., Fujimoto, K., & Suzuki, A. (2019) · IEEE CPMT Symposium Japan (ICSJ) · doi:10.1109/icsj47124.2019.8998686 · Cited by 1
Nakamura, H., Lin, G., & Mitsukura, Y. (2025) · IEEE Access · doi:10.1109/access.2025.3580578 · Cited by 2
Low-Cost Wearable Edge-AI Device for Diabetes Management
Young, L., Wang, D., & Gong, N. (2025) · ACM Great Lakes Symposium on VLSI (GLSVLSI) · doi:10.1145/3716368.3735270 · Cited by 1
Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram
Sviridova, N., & Okazaki, S. (2025) · Sensors · doi:10.3390/s25196232 · Cited by 1
Local heating induces an increase in the pulse wave velocity in peripheral vessels
Kamshilin, A. A., Podolyan, N. P., Mizeva, I. A., Mamontov, O. V., Zaytsev, V. V., Vasilieva, M., Кащенко, В. А., Sakovskaia, A. V., Dolotovskaya, P. M., Борисович, М. Н., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-40041-4 · Cited by 1
Li, X., Li, X., Tan, H., Xu, J., & Yuan, M. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0241-5 · Cited by 1
Analysis of light intensity modulation by red blood cells motion in capillaries
Potemkin, A. V., Kamshilin, A. A., Volkov, M. V., Margaryantz, N. B., Volynsky, M. A., & Gurov, I. P. (2017) · doi:10.1117/12.2284798 · Cited by 1
Detecting Cardiovascular Disease From PPG Signals using Machine Learning
Al-Sadek, T., Ahmad, J., Khoury, F., Badawe, H. M., & Khraiche, M. L. (2023) · IEEE International Multidisciplinary Conference on Engineering Technology (IMCET) · doi:10.1109/imcet59736.2023.10368256 · Cited by 1
Wang, L., Tao, X., Sun, L., & Shen, W. (2024) · SpringerBriefs in computer science · doi:10.1007/978-981-97-4550-0_4 · Cited by 1
Comparison of Measurement Sites in Instantaneous Orthostatic Pulse Rate Measurement
Itoigawa, R., Maeda, Y., Mizutani, K., & Wakatsuki, N. (2018) · Advanced Biomedical Engineering · doi:10.14326/abe.8.14 · Cited by 1
Self-citationPhotoplethysmography Heart Rate Monitoring
Feukeu, E. A., & Winberg, S. L. (2021) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.20210501.oa2 · Cited by 1
Wearable Cyberphysical Systems for Biomedicine
Latif, T., Dieffenderfer, J. P., da Silva, R. L., Lobaton, E. J., & Bozkurt, A. Y. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00124-2 · Cited by 1
Evaluation of the Signal Quality of Wrist-Based Photoplethysmography
Pradhan, N. (2018) · doi:10.22215/etd/2018-12624 · Cited by 1
Vers le développement d'un capteur photoplétysmographique sans contact
Bobbia, S. (2019) · theses.fr (ABES) · doi:10.70675/a3c47f9fz5d34z4690za579zb07025c69b0f · Cited by 1
Physiological Parameter Monitoring System for Patient and Doctors Interface
Reddy, M. B., & Krishnaiah, R. V. (2014)
The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light
Chang, K. Y., Ko, H., Lee, J. J., & Yoon, Y. R. (2014) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2014.35.5.125
Análisis de la variabilidad de la frecuencia cardíaca mediante fotopletismografía por imagen
Rodríguez, A., & Ramos-Castro, J. J. (2014)
Golaraei, A., Raja, V., Akens, M. K., Wilson, B. C., & Barzda, V. (2017) · Clinical and Preclinical Optical Diagnostics · doi:10.1117/12.2284430
Detail-Preserving Signal Fitting for Pulse Wave Detection from Smartphone-Based Fingertip Videos
Liu, X., Yang, X., Jin, J., & Fang, S. (2019) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2019.8803243
Akishin, A. D., Николаев, А. П., & Pisareva, A. V. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2096/1/012186
An Analog Front-End for a Photoplethysmography Patch to Monitor Respiratory Rate
Elokda, M., Jiang, J., Mandile, C. A., & Güler, Ü. (2020) · IEEE MIT Undergraduate Research Technology Conference (URTC) · doi:10.1109/urtc51696.2020.9668886
Measurement of Human Heart Rate: A Cost-Effective Solution to Monitor Cardiovascular Health
Nawaz, R., Sharna, T. A., Akand, M. N. H., & Rahman, R. M. (2022) · IEEE Annual International Computer Software and Applications Conference (COMPSAC) · doi:10.1109/compsac54236.2022.00262
Kamshilin, A. A. (2022) · Bulletin of the Russian Academy of Sciences Physics · doi:10.3103/s1062873822700447
Effect of Filters in Photoplethysmography Analog Signals Using Open-Source LTspice Software
Pandi, & Abuzairi, T. (2024) · International Journal of Electrical Computer and Biomedical Engineering · doi:10.62146/ijecbe.v2i1.32
Wearables and sleep tracking in athletics programs
Lujan, M. R., Perez-Pozuelo, I., & Grandner, M. A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-822969-9.00013-4
Green-Infrared Dominance in Atrial Fibrillation Detection
Devaki, V. (2024) · African Journal of Biomedical Research · doi:10.53555/ajbr.v27i4s.5498
Lai, Y., Lin, Y., Yu, C.-H., Huang, S. K., Liou, C., Wu, Y., & Mao, S. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3564573
Light-Emitting Materials for Wearable Bioelectronics
Okmi, A. (2025) · Engineering materials · doi:10.1007/978-3-031-88731-4_7
Electro-Luminescent System for Detection and Classification of Muscle Movements
Reyes-Jiménez, F., Vega-Martínez, A., Lomelí-García, S., Rosas-Agraz, F., Vélez-Pérez, H. A., & Guzmán-Quezada, E. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-89510-4_15
Contact Imaging Photoplethysmography: Effect of Channel Choice on Dynamical Properties Stability
Sviridova, N., & Mine, A. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-93822-1_9
Accuracy of Pulse-Oximetry in Non-white Patients
Gallagher, J. J., & Adamski, J. L. (2025) · Critical Care Nursing Clinics of North America · doi:10.1016/j.cnc.2025.05.006 · Cited by 1
Han, W., Lu, L., & Li, Q. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5375344
Healthcare on the Move: The Evolution and Future of Wearable Health Tech
Islam, M. (2025) · Information systems engineering and management · doi:10.1007/978-3-031-98897-4_10
Sviridova, N., & Namba, M. (2025) · International Conference on Bioinformatics and Biomedical Technology (ICBBT) · doi:10.1109/icbbt65815.2025.11276208
Metadata
- Authors
- Maeda, Y., Sekine, M., & Tamura, T.
- Affiliations
- Chiba University (JP)
- Corresponding author
- Maeda, Yuka
- Venue
- Journal of Medical Systems
- Published
- 2010-05-18
- Volume
- 35
- Issue
- 5
- Pages
- 829-834
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W2040137929
- Cited by
- 209
- References
- 6
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 15 · 2023: 20 · 2022: 22 · 2021: 25 · 2020: 15 · 2019: 17 · 2018: 13 · 2017: 19 · 2016: 5 · 2015: 9 · 2014: 7 · 2013: 3 · 2012: 1
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- heat stress, pulse rate monitoring, wearable sensors, cold exposure, vascular blood flow
- MeSH terms
- Adult, Blood Pressure Determination, Color, Humans, Infrared Rays, Monitoring, Physiologic, Skin Temperature, Photoplethysmography, Young Adult, Wavelet Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review