The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The Advantages of Wearable Green Reflected Photoplethysmography
Abstract
This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Mio Alpha's PPG technology was previously validated against a standard electrocardiogram (ECG) (Maeda, Sekine, Tamura, 2011a)”
From Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance (2017) · cites this paper as Maeda, Sekine, Tamura, 2011a
In the citing paper
“Green is preferred to red and infrared since this wavelength does not penetrate deep into tissue causing fewer artifacts from a non-pulsatile slow-changing component [55].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [55]
In the citing paper
“Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter [30,80,102].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [102]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Pulsed multifrequency photoplethysmograph
Giltvedt, J., Sira, A., & Helme, P. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442745 · Cited by 47
Green Light Photoplethysmography Monitoring of Free Flaps
Futran, N. D., Stack, B. C., Hollenbeak, C. S., & Scharf, J. (2000) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.126.5.659 · Cited by 35
Cited by
Sorted by citations
Items 201–209 of 209
Li, L., Taha, S. N. S., Nishinaka, Y., Tan, Y., Ohtsu, H., Sinyoung, L. E. E., & Kiyono, K. (2026) · Sensors · doi:10.3390/s26041118
Sokolov, A. Y., Zaytsev, V. V., Shcherbinin, A. V., & Kamshilin, A. A. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1777457
Hybrid deep learning-based blood glucose level monitoring using PPG signals
Soliman, A. Y., Nor, A. M., Omer, O. A., & Mubarak, A. S. (2026) · Signal Image and Video Processing · doi:10.1007/s11760-026-05368-5
Sato, S., & Nakayama, S. (2026) · Biomedical Engineering Advances · doi:10.1016/j.bea.2026.100220
Guo, M., Cui, H., Yang, B., Jiang, S., Xu, Z., Li, Z., & Wang, Z. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.118265
Du, K., Zhao, M., Wang, T., & Hongxing, 蔡. C. (2026) · Journal of Russian Laser Research · doi:10.1007/s10946-026-10329-x
Sapkota, M., Thakur, J., Karki, M., Aryal, U., & Tulachan, S. B. (2026) · Journal of Electronics and Informatics · doi:10.36548/jei.2026.4.003
Metadata
- Authors
- Maeda, Y., Sekine, M., & Tamura, T.
- Affiliations
- Chiba University (JP)
- Corresponding author
- Maeda, Yuka
- Venue
- Journal of Medical Systems
- Published
- 2010-05-18
- Volume
- 35
- Issue
- 5
- Pages
- 829-834
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W2040137929
- Cited by
- 209
- References
- 6
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 15 · 2023: 20 · 2022: 22 · 2021: 25 · 2020: 15 · 2019: 17 · 2018: 13 · 2017: 19 · 2016: 5 · 2015: 9 · 2014: 7 · 2013: 3 · 2012: 1
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- heat stress, pulse rate monitoring, wearable sensors, cold exposure, vascular blood flow
- MeSH terms
- Adult, Blood Pressure Determination, Color, Humans, Infrared Rays, Monitoring, Physiologic, Skin Temperature, Photoplethysmography, Young Adult, Wavelet Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review