A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions
The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Prospective Natural-History Study of Coronary Atherosclerosis
Stone, G. W., Maehara, A., Lansky, A. J., de Bruyne, B., Cristea, E., Mintz, G. S., Mehran, R., McPherson, J., Farhat, N., Marso, S. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1002358 · Cited by 3,276
Small-scale soft-bodied robot with multimodal locomotion
Hu, W., Lum, G. Z., Mastrangeli, M., & Sitti, M. (2018) · Nature · doi:10.1038/nature25443 · Cited by 2,372
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339 · cited 1×
“The physician then uses the catheter to scar a small section of the heart by making tiny burns using radiofrequency energy [21, 22].”
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Introduction to magnetism and magnetic materials
(2016) · Choice Reviews Online · doi:10.5860/choice.195889 · Cited by 1,518
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006464 · Cited by 1,381
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161 · cited 3×
“They demonstrated the performance of the guidewire in a 2D blood vessel phantom, where a uniform external magnetic field was generated by an eightcoil electromagnetic system called MiniMag (MagnebotiX, Zurich, Switzerland) [87].”
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jai¨s, P., Hai¨ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Cle´menty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,117 · cited 1×
“The physician then uses the catheter to scar a small section of the heart by making tiny burns using radiofrequency energy [21, 22].”
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Cited by
Magnetic Actuation Methods in Bio/Soft Robotics
Ebrahimi, N., Bi, C., Cappelleri, D. J., Ciuti, G., Conn, A. T., Faivre, D., Habibi, N., Hošovský, A., Iacovacci, V., Khalil, I. S. M., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202005137 · Cited by 353
Magnetic soft microfiberbots for robotic embolization
Liu, X., Wang, L., Xiang, Y., Liao, F., Li, N., Li, J., Wang, J., Wu, Q., Zhou, C., Yang, Y., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh2479 · Cited by 213
Magnetically Controlled Soft Robotics Utilizing Elastomers and Gels in Actuation: A Review
Chung, H., Parsons, A. M., & Zheng, L. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202000186 · Cited by 196
Dexterous helical magnetic robot for improved endovascular access
Dreyfus, R., Boehler, Q., Lyttle, S., Gruber, P., Lussi, J., Chautems, C., Gervasoni, S., Berberat, J., Seibold, D., Ochsenbein-Kölble, N., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh0298 · Cited by 185
“Traditionally, mCRs are designed with one or more strong but rigid distal permanent magnets connected by flexible tubular sections ( 35 , 36 , 49 , 81 – 83 ).”
BackgroundMicro/nanoscale magnetic robots for biomedical applications
Koleoso, M., Feng, X., Xue, Y., Li, Q., Munshi, T., & Chen, X. (2020) · Materials Today Bio · doi:10.1016/j.mtbio.2020.100085 · Cited by 174
“Beyond research examples, another recent review paper detailed current commercial magnetic actuation systems, such as Niobe, Genesis, Aeon Phocus, MiniMag, OctoMag, and Catheter Guidance Control and Imaging systems [58].”
MethodMagnetically Actuated Continuum Medical Robots: A Review
Yang, Z., Yang, H., Cao, Y., Cui, Y., & Zhang, L. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200416 · Cited by 165
Endovascular Microrobotics for Neurointervention
Santiago-Dieppa, D. R., & Friend, J. (2024) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060523-010720 · Cited by 12
Metadata
- Authors
- Hwang, J., Kim, J.-Y., & Choi, H.
- Venue
- Intelligent Service Robotics
- Published
- 2020-01
- Volume
- 13
- Issue
- 1
- Pages
- 1-14
- ISSN
- 1861-2776 (ISSN-L)
- 1861-2784
- OpenAlex
- W3001194984
- Cited by
- 181
- References
- 68
- FWCI
- 22.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.