Electrical stimulation for the suppression of pathological tremor
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson's disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of the above systems, several were demonstrated with individuals with tremor [17–20, 27–32] resulting in ~ 20–88% tremor attenuation levels”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [30]
In the citing paper
“This system was tested on seven patients (three ET and four PD); although one of them did not respond to the stimulation, the remaining six showed an average tremor suppression of 67.0 ± 13.0%.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [66]
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“A tremor is an involuntary, rhythmic oscillation of a body part [4].”
BackgroundMechanism of action of deep brain stimulation.
Benazzouz, A., & Hallett, M. (2000) · PubMed · Cited by 350
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“It has been shown that tremor can be mechanically suppressed using external skeletons in form of anthropomorphic robots [16, 17].”
BackgroundAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15 ].”
MethodTremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 139
Malešević, N., Popović‐Maneski, L., Schwirtlich, L. B., & Popović, D. B. (2010) · Muscle & Nerve · doi:10.1002/mus.21736 · Cited by 124
Self-citationMulti‐Field Surface Electrode for Selective Electrical Stimulation
Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29075.x · Cited by 97
Self-citationAttenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation
Javidan, M., Elek, J., & Prochazka, A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368522 · Cited by 80 · cited 1×
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15].”
BackgroundAutomatic determination of the optimal shape of a surface electrode: Selective stimulation
Popović, D. B., & Popović, M. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.12.003 · Cited by 78
Self-citationMechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68 · cited 1×
“It has been shown that tremor can be mechanically suppressed using external skeletons in form of anthropomorphic robots [ 16 , 17].”
Background
Cited by
A multi-pad electrode based functional electrical stimulation system for restoration of grasp
Malešević, N. M., Maneski, L. Z., Ilić, V., Jorgovanović, N., Bijelić, G., Keller, T., & Popović, D. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-66 · Cited by 178
Self-citationBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Online tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
Self-citationEvancho, A. M., Tyler, W. J., & McGregor, K. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1151218 · Cited by 114
Electrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67
“…the use of external devices to suppress tremor by mechanical loading (Pledgie et al., 2000; Rocon et al., 2007) or electrical stimulation (Javidan et al., 1992; Prochazka et al., 1992; Gillard et al., 1999; Popović Maneski et al., 2011; Gallego et al., 2013; Bó et al., 2014; Dosen et al., 2015).”
BackgroundMethodSelf-citationPeripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
“[41] reported 67 ± 13% average acute reduction in three and four patients with ET and PD respectively.”
BackgroundMethodResultInfluentialMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 78
“One patient, however, did not respond, suggesting that out-of-phase stimulation may not work for all patients with tremor [79].”
BackgroundMethodA Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“Besides, muscle fatigue due to induced contraction also decreases the effectiveness of these devices (66).”
BackgroundMethodInfluentialAdaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
“Functional electrical stimulation has been used to stimulate the tremorogenic muscles and attenuate tremor amplitude [6]–[8].”
MethodJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2017) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2017.08.3246 · Cited by 51
Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
“Eng. 8, 53–59. doi:10.1109/86.830949 Popović, L. Z., Sekara, T. B., and Popović, M. B. (2010).”
MethodInfluentialAtashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Murphy, M. D., Guggenmos, D. J., Bundy, D. T., & Nudo, R. J. (2016) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00497 · Cited by 59
Adaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremor
Wang, S., Gao, Y., Zhao, J., & Cai, H. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.004 · Cited by 42
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
On the Use of Fixed‐Intensity Functional Electrical Stimulation for Attenuating Essential Tremor
Bó, A. P. L., Azevedo‐Coste, C., Geny, C., Poignet, P., & Fattal, C. (2014) · Artificial Organs · doi:10.1111/aor.12261 · Cited by 40
“Pioneer studies on the topic (8), and also more recent studies (9,10), were based on applying FES to activate antagonist muscles in antiphase with respect to the trembling motion in order to reduce tremor amplitude.”
An integrated wearable robot for tremor suppression with context aware sensing
Huen, D., Liu, J., & Lo, B. P. L. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516280 · Cited by 41
“Several wearable tremor suppression devices are proposed [15-29], however, many of these devices are bulky, heavy and too power An Integrated Wearable Robot for Tremor Suppression with Context Aware Sensing”
BackgroundVib-bracelet: a passive absorber for attenuating forearm tremor
Buki, E., Katz, R., Zacksenhouse, M., & Schlesinger, I. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1742-7 · Cited by 42
“The frequency range over which the Vib-bracelet attenuates vibrations is typical to forearm tremor of PD patients as measured in our experiments (pronation/supination) and as presented in the literature [12].”
BackgroundJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.08.1527 · Cited by 38
Trout, M. A., Harrison, A. T., Brinton, M. R., & George, J. A. (2023) · Scientific Reports · doi:10.1038/s41598-023-30545-8 · Cited by 39
Puttaraksa, G., Muceli, S., Gallego, J. Á., Holobar, A., Charles, S. K., Pons, J. L., & Farina, D. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00407.2019 · Cited by 35
“This variation of the phase difference over time could explain the limited effectiveness of tremor suppression strategies that apply out-of-phase stimulation to antagonist muscle groups (Dosen et al. 2015; Popović Maneski et al. 2011).”
BackgroundNon-invasive electrical stimulation of peripheral nerves for the management of tremor
Valdunciel, A. P., Rajagopal, A., Pons, J. L., & Delp, S. L. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120195 · Cited by 39
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“PHT therapies such as oral medication, therapeutic lesions, Gamma-knife radiosurgery, and Deep Brain Stimulation (DBS) 18 focus on alleviating tremor severity and improving arm functionality 19–21 .”
BackgroundHerrnstadt, G., McKeown, M. J., & Menon, C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0484-1 · Cited by 30
On-Off Tremor Suppression Orthosis with Electromagnetic Brake
Herrnstadt, G., & Menon, C. (2013) · International Journal of Mechanical Engineering and Mechatronics · doi:10.11159/ijmem.2013.002 · Cited by 32
Sensory electrical stimulation for suppression of postural tremor in patients with essential tremor
Heo, J.-H., Kim, J.-W., Kwon, Y., Lee, S.-K., Eom, G.-M., Kwon, D.-Y., Lee, C.-N., Park, K.-W., & Manto, M. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151372 · Cited by 30
“Two commercially available electrical stimulators (Walking man 2, Cybermedic, Korea) were used for the stimulation of four muscles (Flexor Carpi Radialis, Extensor Carpi Radialis, Biceps Brachii, and Triceps Brachii), associated with the movements of finger, wrist, and elbow [14-15].”
MethodHao, M.-Z., Xu, S.-Q., Hu, Z.-X., Xu, F.-L., Niu, C.-X. M., Xiao, Q., & Lan, N. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0286-2 · Cited by 29
Admittance-Based Voluntary-Driven Motion With Speed-Controlled Tremor Rejection
Herrnstadt, G., & Menon, C. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2555811 · Cited by 29
Simulated Tremor Propagation in the Upper Limb: From Muscle Activity to Joint Displacement
Corie, T., & Charles, S. K. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4043442 · Cited by 30
Menguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Biomechanical loading as an alternative treatment for tremor: a review of two approaches
Rocon, E., Gallego, J. Á., Belda-Lois, J. M., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.107 · Cited by 26
Peripherical Electrical Stimulation for Parkinsonian Tremor: A Systematic Review
Meng, L., Jin, M., Zhu, X., & Ming, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.795454 · Cited by 30
“The out-of-phase stimulation activates the antagonist muscle contraction to generate an opposite force for reducing tremor (Maneski et al., 2011), as shown in Figure 2A.”
BackgroundMethodInfluentialBiomechanical Loading as an Alternative Treatment for Tremor: A Review of Two Approaches
Rocón, E., Gallego, J. Á., Lois, J. M. B., Benito‐León, J., & Pons, J. L. (2011) · PubMed · doi:10.7916/d82z147g · Cited by 26
Rationale and Evidence for Peripheral Nerve Stimulation for Treating Essential Tremor
Shukla, A. W. (2022) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.685 · Cited by 25
Essential tremor amplitude modulation by median nerve stimulation
Reis, C., Arruda, B. S., Pogosyan, A. H., Brown, P., & Cagnan, H. (2021) · Scientific Reports · doi:10.1038/s41598-021-96660-6 · Cited by 26
Abbasi, M., Afsharfard, A., Arasteh, R., & Safaie, J. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1769-9 · Cited by 24
Shah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21
“Numerous methods with different sensors, including EMG [2, 15, 17, 25, 44], spirograms [7, 37], and gyroscopes [23, 32, 38], have been used to quantify tremor.”
MethodMotiMove: Multi‐purpose transcutaneous functional electrical stimulator
Popović‐Maneski, L., & Mateo, S. (2022) · Artificial Organs · doi:10.1111/aor.14379 · Cited by 19
Self-citationPigg, A. C., Thompson‐Westra, J., Mente, K., Maurer, C. W., Haubenberger, D., Hallett, M., & Charles, S. K. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.08.010 · Cited by 22
Development of a closed-loop system for tremor suppression in patients with Parkinson's disease
Xu, F. L., Hao, M. Z., Xu, S. Q., Hu, Z. X., Xiao, Q., & Lan, N. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591063 · Cited by 18
“Lana and colleagues [5] stabilized affected joints by activating the antagonistic muscles using sensor-driven electrical stimulation.”
BackgroundTrends in rehabilitation robotics
García-Aracil, N., Sabater-Navarro, J. M., Gugliemelli, E., & Casals, A. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0836-x · Cited by 18
“[11] also propose a new method, based on adaptative oscillators, for providing assistance during cyclical movements.”
MethodModeling and experimental study of a hand tremor suppression system
Abbasi, M., & Afsharfard, A. (2018) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2018.04.009 · Cited by 18
Hu, Z.-X., Xu, S., Hao, M., Xiao, Q., & Lan, N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab186f · Cited by 17
Tremor Control Devices for Essential Tremor: A Systematic Literature Review
Castrillo-Fraile, V., Casas-Peña, E., Trejo Gabriel Y Galán, J. M., López, P. D. D., Collazo, C., & Cubo, E. (2019) · Europe PMC (PubMed Central) · doi:10.7916/tohm.v0.688 · Cited by 17
Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00221 · Cited by 16
“Other studies have shown that it is possible to attenuate the tremor using the human muscle tissue as actuators, through functional electrical stimulation (Javidan et al., 1992; Popović Maneski et al., 2011; Gallego et al., 2013; Bó et al., 2014).”
BackgroundDynamic Decomposition of Motion in Essential and Parkinsonian Tremor
Rahimi, F., Debicki, D., Roberts, A., Bee, C., Bapat, P., & Jog, M. (2015) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/cjn.2015.12 · Cited by 16
Fujikawa, J., Morigaki, R., Yamamoto, N., Oda, T., Nakanishi, H., Izumi, Y., & Takagi, Y. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.807909 · Cited by 19
“A pilot study of MOTIMOVE showed 67% tremor suppression in patients with ET and PD (Popovic Maneski et al., 2011).”
MethodA two-step model to optimise transcutaneous electrical stimulation of the human upper arm
Goffredo, M., Schmid, M., Conforto, S., Bilotti, F., Palma, C., Vegni, L., & D’Alessio, T. (2014) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-04-2013-0118 · Cited by 14
Tremor Suppression Using Functional Electrical Stimulation
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Friedman, E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3453222 · Cited by 17
“FES contracts the flexor and extensor muscles simultaneously (co-contraction method) [11], [13], or in an alternating way to counteract tremor (out-of-phase) [8], [9], [10], [12], [14].”
BackgroundNon-invasive Central and Peripheral Stimulation: New Hope for Essential Tremor?
Chalah, M. A., Lefaucheur, J., & Ayache, S. S. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00440 · Cited by 17
Tremor Suppression With Mechanical Vibration Stimulation
Liu, W., Kai, T., & Kiguchi, K. (2020) · IEEE Access · doi:10.1109/access.2020.3045023 · Cited by 13
“In the other strategy, stimulation is delivered counterphase to the muscles so that the tremor is suppressed by the generated opposing forces [20]-[24].”
BackgroundMethodInfluentialWearable Peripheral Electrical Stimulation Devices for the Reduction of Essential Tremor: A Review
Karamesinis, A. D., Sillitoe, R. V., & Kouzani, A. Z. (2021) · IEEE Access · doi:10.1109/access.2021.3084819 · Cited by 14
“tremor patients failed to respond at all to the electrical stimulation, demonstrating that this treatment, similarly to other treatments for essential tremor, may not be effective for all patients [47], [68].”
BackgroundResultInfluentialCONTINUOUS SENSORY ELECTRICAL STIMULATION FOR THE SUPPRESSION OF PARKINSONIAN REST TREMOR
Heo, J.-H., Jeon, H.-M., Choi, E.-B., Kwon, D., & Eom, G. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519418400067 · Cited by 16
SUPPRESSION OF ACTION TREMOR BY SENSORY ELECTRICAL STIMULATION IN PATIENTS WITH ESSENTIAL TREMOR
HEO, J.-H., KWON, Y., JEON, H.-M., KWON, D.-Y., LEE, C.-N., PARK, K.-W., MANTO, M., KIM, J.-W., & EOM, G.-M. (2016) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519416400261 · Cited by 12
Puttaraksa, G., Muceli, S., Barsakcioglu, D. Y., Holobar, A., Clarke, A. K., Charles, S. K., Pons, J. L., & Farina, D. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3158606 · Cited by 13
Standring, D. J., Pigg, A. C., Thompson‐Westra, J., Mente, K., Maurer, C. W., Haubenberger, D., Hallett, M., & Charles, S. K. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.07.001 · Cited by 15
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995590.012 · Cited by 12
A green and simple process to develop conductive polyurethane foams for biomedical applications
Caba, V., Borgese, L., Agnelli, S., & Depero, L. E. (2018) · International Journal of Polymeric Materials · doi:10.1080/00914037.2018.1525732 · Cited by 12
Multimodal Tremor Suppression of the Wrist Using FES and Electric Motors–A Simulation Study
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Naish, M. D., & Trejos, A. L. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3316607 · Cited by 11
Tudela-Pi, M., Minguillón, J., Becerra-Fajardo, L., & Ivorra, A. (2021) · IEEE Access · doi:10.1109/access.2021.3096729 · Cited by 15
Phokaewvarangkul, O., Vateekul, P., Wichakam, I., Anan, C., & Bhidayasiri, R. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.727654 · Cited by 13
Shah, V. V., Goyal, S., & Palanthandalam‐Madapusi, H. J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2746623 · Cited by 11
“muscles [29], [30] and [31], [62] and sensory stimulation at flexor and extensor carpi readialis [32].”
BackgroundMotor point stimulation induces more robust F‐waves than peripheral nerve stimulation
Kaneko, N., Fok, K. L., Nakazawa, K., & Masani, K. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15625 · Cited by 13
Shaking Up Essential Tremor: Peripheral Devices and Mechanical Strategies to Reduce Tremor
Adabi, K., & Ondo, W. G. (2024) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.930 · Cited by 16
Gordleeva, S., Grigorev, N., Николаевна, П. Е., Kurkin, S., Kazantsev, V., & Hramov, A. E. (2025) · Ageing Research Reviews · doi:10.1016/j.arr.2025.102923 · Cited by 12
Bilateral transcranial direct current stimulation may be a feasible treatment of Parkinsonian tremor
Zhang, B., Huang, F., Liu, J., & Zhang, D. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1101751 · Cited by 11
“The effect of tDCS was also proven by other studies combining tDCS with other methods, such as tDCS + occupational therapy (Nair et al., 2011), tDCS + FES (Shaheiwola et al., 2018) etc. Additionally, the motor functions of stroke patients were found to improve better with combined methods than with either technique al…”
BackgroundUpper Limb Neuroprostheses: Recent Advances and Future Directions
Koutsou, A. D., Summa, S., Nasser, B., Gutiérrez-Martínez, J., & Thangaramanujam, M. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-38556-8_11 · Cited by 9
“mor by applying FES (Gallego et al. 2011; Popović-Maneski et al. 2011).”
MethodArruda, B. S., Reis, C., Sermon, J. J., Pogosyan, A. H., Brown, P., & Cagnan, H. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00973-6 · Cited by 10
Dynamic estimation strategy for E-BMFLC filters in analyzing pathological hand tremors
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308681 · Cited by 8
“Based on a similar motivation, in [6] and [7], arrays of functional electrical stimulators are used (instead of an electromechanical actuators) to counteract hand tremor of PD and ET patients by activating antagonistic muscle pairs.”
BackgroundDevelopment and Validation of a Finger Tremor Simulator
Zhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2018) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2018.8447595 · Cited by 8
“Additional results [11–15] have been reported that indicate that active suppression devices have become a viable alternative solution for tremor management.”
BackgroundTargeting the fundamentals for tremors: the frequency and amplitude coding in essential tremor
Pan, M. (2025) · Journal of Biomedical Science · doi:10.1186/s12929-024-01112-8 · Cited by 11
Impact of suppressed tremor: Is suppression of proximal joints sufficient?
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2018.8333369 · Cited by 7
EFFECT OF GYROSCOPE PARAMETERS ON GYROSCOPIC TREMOR SUPPRESSION IN A SINGLE DEGREE OF FREEDOM
Allen, B. C., & Charles, S. K. (2019) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519419500246 · Cited by 8
Studies on a Robotic Device that Minimizes End-Point Vibrations for Parkinson Tremor
Ayana, E. K., Yaşar, C. F., & Engin, Ş. N. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.09.060 · Cited by 6
Mengüç, E. C., & Rezayi, N. (2019) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2019.8806387 · Cited by 7
“[12] L.”
Lee, S. K., Kim, J. W., Kwon, Y., Lee, Y. J., Lee, J. H., Eom, G., Kwon, D., Lee, C. N., Seo, Y.-W., Kim, M. K., et al. (2013) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2013.34.3.129 · Cited by 5
“FES (functional electrical stimulation)를 이용한 진전 억 제 방법을 제안하였다[12-14].”
Zhou, Y., Box, D., Hardy, K. G., Jenkins, M. E., Garland, S. J., Naish, M. D., & Trejos, A. L. (2022) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/20556683221094480 · Cited by 5
Kiguchi, K., Kai, T., & Liu, W. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283118 · Cited by 4
Estimation of pathological tremor by using adaptive shifting BMFLC base d on RLS algorithm
Gao, Y., Wang, S., Zhao, J., & Cai, H. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6617979 · Cited by 4
“Under the requirement of effective methods for suppressing tremor, biomechanical loading [3-5], functional electrical stimulations (FES) [6-8] or other methods are developed.”
MethodBiofeedback Specialization Effect on Physiological Tremor Amplitude Dynamics
Aleksandrov, A. Y., Uplisova, K. O., & Ivanova, V. (2020) · Human Physiology · doi:10.1134/s036211972001003x · Cited by 4
“Apart from the need to design methods to correct pathological tremor forms [7], methods to temporally or permanently reduce the physiological tremor amplitude are desirable in certain fields, such as elite sports and certain special activities that require highly accurate micromanipulations.”
Mengüç, E. C. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219889171 · Cited by 4
“Parameters The first experiment The second experiment MSE Correlation MSE Correlation LMS LMK LMS LMK LMS LMK LMS LMK M= 1 and f0 = 4Hz 1.1801 0.1239 0.9300 0.9929 0.0039 0.0019 0.8910 0.9474 M= 1 and f0 = 8Hz 0.0467 0.0395 0.9974 0.9978 7.76x10 4 1.61x10 4 0.9789 0.9958 M= 1 and f0 = 8:6Hz 0.0703 0.0453 0.9960 0.9974…”
BackgroundInfluentialShahtalebi, S., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308679 · Cited by 3
“This makes tremor estimation and extraction of paramount importance in various application domains ranging from assisted robotic surgery to assistive, wearable, and rehabilitative devices [9–13].”
BackgroundMetzner, C., Stringham, A., Hislop, B., Bonham, J., Chatterton, L., DeFigueiredo, R., & Charles, S. K. (2023) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.740 · Cited by 6
Ultrasound Imaging Triggered Tremor Suppression With Personalized Afferent Stimulation Frequency
Iyer, A., Xue, X., Ganesh, V., Jiang, X., Gallippi, C. M., Roque, D., & Sharma, N. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3519628 · Cited by 4
“We argue that a US imaging-based sensing approach holds promise over different instrumentation/techniques used in tremorsuppressioncontrol,namelyaccelerometersandgyrosen-sors[8].”
A Non-Invasive, Soft Robotic Wearable Glove to Attenuate Hand Tremors
Youhanaie, K., & Hashem, R. (2022) · Journal of Student Research · doi:10.47611/jsrhs.v11i3.3814 · Cited by 2
Baker, S. A., Beutler, L. J., Free, D. B., Farina, D., & Charles, S. K. (2025) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.949 · Cited by 4
Spinal Interfacing via Muscle Recordings for Neuroprosthesis Control
Muceli, S., & Farina, D. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_29-1 · Cited by 2
Variability of Parkinsonian Tremor During Different Tasks and Under External Interference
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Friedman, E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3470556 · Cited by 2
“These devices are based on mechanical or electrical suppression actuation systems [4], [5], [6], [7], [8], [9], [10], [11], [12] and are designed to reduce tremor and allow participants to perform their activities of daily living more comfortably.”
BackgroundTatinati, S., & Veluvolu, K. C. (2013) · International Conference on Power, Energy and Control · doi:10.1109/icpec.2013.6527703 · Cited by 2
“To overcome the phase delay during estimation, adaptive algorithms are employed for modeling and compensating the tremor [5]–[8].”
MethodAlternative Technological Interventions for Analysis of Neurodegenerative Tremors
Ganguly, R., Nagarsheth, D., Thippana, E., & Nag, P. (2024) · Control Instrumentation System Conference (CISCON) · doi:10.1109/ciscon62171.2024.10696412 · Cited by 1
“The resultant decrease in tremors measured at the wrist for all six of seven patients was 61 ± 7% [23].”
BackgroundMethodZhao, X., Huang, T., Jin, M., Zhao, H., Shi, Y., Wang, Y., Shen, X., Li, Z., Shi, Q., Zhu, X., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3591134 · Cited by 1
Ruiz-Olaya, A. F., López-Delis, A., & Cerquera, A. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-18914-7_15 · Cited by 1
“In literature, FES has been evaluated to assist neurorehabilitation processes in people after stroke [7], [4], [5], rehabilitation after spinal cord injury [8], and suppression of pathological tremor [9].”
BackgroundCarvalho, E., Silva, C., Santos, A. P., Martins, F. L. M., Barbosa, M. A., & Barbosa, A. C. (2015) · ConScientiae Saúde · doi:10.5585/conssaude.v14n1.5297 · Cited by 1
Instrumentation: Classical and Emerging Techniques
Kraus, P. H. (2012) · Contemporary clinical neuroscience · doi:10.1007/978-1-4614-4027-7_19 · Cited by 1
MODEL OF AN ADAPTIVE ENERGY HARVESTER WITH ELECTRO-RHEOLOGICAL FLUID
Teodorescu, H.-N. (2015) · Cited by 1
A novel fully fast recovery EMG amplifier for the control of neural prosthesis
Ilić, V., Jorgovanović, N., Antić, A., Morača, S., & Ungureanu, N. S. (2016) · Tehnicki vjesnik - Technical Gazette · doi:10.17559/tv-20150710101906 · Cited by 1
“To verify amplifiers characteristics in the presence of the stimulation artifact, we used monophasic and biphasic stimulation pulses by the INTFES V1 electronic stimulator [22] and monophasic compensated pulse by the TremUNA stimulator [23].”
MethodSelf-citationSpinal Interfacing via Muscle Recordings for Neuroprosthesis Control
Muceli, S., & Farina, D. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_29 · Cited by 1
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Bhosale, P., Rewatkar, R. M., Pokle, P. B., & Reddy, K. T. V. (2024) · DMIHER International Conference on Artificial Intelligence in Healthcare, Education and Industry (IDICAIHEI) · doi:10.1109/idicaiei61867.2024.10842711 · Cited by 1
Ruiz-Olaya, A. F., & López-Delis, A. (2015) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-4666-7373-1.ch001 · Cited by 3
Metadata
- Authors
- Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B.
- Affiliations
- University of Novi Sad (RS)
- Tecnalia (ES)
- University of Belgrade (RS)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2011-07-14
- Volume
- 49
- Issue
- 10
- Pages
- 1187-1193
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1995477441
- Semantic Scholar
- 98ef177506afc865c5ce90349226e364b294c17b
- Cited by
- 129
- References
- 20
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 8 · 2023: 8 · 2022: 14 · 2021: 13 · 2020: 7 · 2019: 10 · 2018: 8 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 7 · 2013: 8 · 2012: 3
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- pathological tremor, electrical stimulation, inertial sensors, adaptive control, Parkinson's disease, essential tremor, tremor suppression
- MeSH terms
- Adult, Aged, Electric Stimulation Therapy, Equipment Design, Female, Humans, Male, Middle Aged, Parkinson Disease, Software Design, Tremor, Treatment Outcome, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.