Abstract
INTRODUCTION: In Sweden an estimated 10,000 people with type 1 diabetes use continuous subcutaneous insulin infusion (CSII). Sensor-augmented pump therapy (SAP) is associated with higher acquisition costs but provides additional clinical benefits (e.g. reduced rate of hypoglycemic events) over and above that of CSII alone. The aim of the analysis was to assess the cost-effectiveness of SAP with automated insulin suspension relative to CSII alone in two different groups of patients with type 1 diabetes in Sweden. METHODS: Cost-effectiveness analyses were performed using the QuintilesIMS CORE Diabetes Model, with clinical and economic input data derived from published literature. Separate analyses were performed for patients at increased risk of hypoglycemia and for patients with uncontrolled glycated hemoglobin (HbA1c) at baseline. Analyses were performed from a societal perspective over a lifetime time horizon. Future costs and clinical outcomes were discounted at 3% per annum. RESULTS: SAP with automated insulin suspension was associated with an incremental gain in quality-adjusted life expectancy versus the CSII of 1.88 quality-adjusted life years (QALYs) in patients at high risk of hypoglycemia and of 1.07 QALYs in patients with uncontrolled HbA1c at baseline. Higher lifetime costs for SAP with automated insulin suspension resulted in projected incremental cost-effectiveness ratios for the SAP with automated insulin suspension versus CSII of Swedish Krona (SEK) 139,795 [euros (EUR) 14,648] per QALY gained for patients at increased risk for hypoglycemia and SEK 251,896 (EUR 26,395) per QALY gained for patients with uncontrolled HbA1c. In both groups, SAP with automated insulin suspension also reduced the incidence of diabetes-related complications relative to CSII. CONCLUSIONS: In Sweden, SAP with automated insulin suspension likely represents a cost-effective treatment option relative to CSII for the management of patients with type 1 diabetes with a history of severe hypoglycemic events or patients who struggle to achieve good glycemic control despite the use of CSII. FUNDING: Medtronic International Trading Sàrl.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glycemic Control and Excess Mortality in Type 1 Diabetes
Lind, M., Svensson, A.-M., Kosiborod, M., Gudbjörnsdottir, S., Pivodic, A., Wedel, H., Dahlqvist, S., Clements, M., & Rosengren, A. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1408214 · Cited by 964
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411 · cited 4×
“However, since publication of that report, clinical evidence has accrued which suggests that SAP with automated insulin suspension contributes to a reduced incidence of hypoglycemic events, particularly nocturnal hypoglycemic events [12, 13, 16, 21].”
BackgroundInfluentialMisso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
The impact of non-severe hypoglycemic events on work productivity and diabetes management
Brod, M., Christensen, T., Thomsen, T. L., & Bushnell, D. M. (2011) · Value in Health · doi:10.1016/j.jval.2011.02.001 · Cited by 284
(2015) · doi:10.1136/bmj.h3234 · Cited by 258 · cited 6×
“Data from the Swedish NDR has also shown that CSII is associated with a significantly lower hazard ratio for fatal coronary heart disease, fatal cardiovascular disease and all-cause mortality relative to MDI [8].”
InfluentialSelf-citationPeters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250 · cited 1×
“CSII with CGM was also recommended in the Endocrine Society Clinical Practice guidelines for type 1 diabetes patients failing to achieve HbA1c targets as well as for well-controlled patients willing to use CGM on an almost daily basis [17].”
MethodFonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Yang, K., Yang, X., Jin, C., Ding, S., Liu, T., Ma, B., Sun, H., Zhang, J., & Li, Y. (2024) · BMJ · doi:10.1136/bmj-2023-078432 · Cited by 172
Pease, A., Zomer, E., Liew, D., Earnest, A., Soldatos, G., Ademi, Z., & Zoungas, S. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0064 · Cited by 39
Jendle, J., & Reznik, Y. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15087 · Cited by 26
Self-citationMathieu, C., Ahmed, W., Gillard, P., Cohen, O., Vigersky, R., de Portu, S., & Ozdemir Saltik, A. Z. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0438 · Cited by 16
“22,26,30,31,33,35 In 16 studies, results demonstrated that the AID system of choice was cost-effective, with one additional study (set in Greece) demonstrating that the AHCL MiniMed (cid:2) 780G system was dominant (cost-saving while leading to higher incremental QALY gains) compared to SAP with…”
Metadata
- Authors
- Jendle, J., Smith-Palmer, J., Delbaere, A., de Portu, S., Papo, N., Valentine, W., & Roze, S.
- Venue
- Diabetes Therapy
- Published
- 2017-09-04
- Volume
- 8
- Issue
- 5
- Pages
- 1015-1030
- ISSN
- 1869-6953 (ISSN-L)
- 1869-6961
- OpenAlex
- W2751941061
- Cited by
- 20
- References
- 13
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.