The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Chemiluminescent immunoassay technology: what does it change in autoantibody detection?
Open accessAbstract
Diagnostic technology is rapidly evolving, and over the last decade, substantial progress has been made even for the identification of antibodies, increasingly approaching this type of diagnostic to that of automated clinical chemistry laboratory. In this review, we describe the analytical and diagnostic characteristics of chemiluminescence technology in its strength and in its applicability for a more rapid and accurate diagnosis of autoimmune diseases. The wide dynamic range, greater than that of immunoenzymatic methods, the high sensitivity and specificity of the results expressed in quantitative form, the high degree of automation and the clinical implications related to the reduction in the turnaround time, and the ability to run a large number of antibody tests (even of different isotypes), directed towards large antigenic panels in random access mode, make this technology the most advanced in the clinical laboratory, with enormous repercussions on the workflow and on the autoimmunology laboratory organisation. Further improvements are expected in the coming years with the development of new analytical platforms such as the flow-injection chemiluminescent immunoassay, the two-dimensional resolution for chemiluminescence multiplex immunoassay and the magnetic nanoparticles chemiluminescence immunoassay, which will likely result in additional increases in the clinical efficacy of antibody tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aletaha, D., Neogi, T., Silman, A. J., Funovits, J., Felson, D. T., Bingham, C. O., Birnbaum, N. S., Burmester, G. R., Bykerk, V. P., Cohen, M. D., et al. (2010) · Arthritis & Rheumatism · doi:10.1002/art.27584 · Cited by 9,619
Petri, M., Orbai, A., Alarcón, G. S., Gordon, C., Merrill, J. T., Fortin, P. R., Bruce, I. N., Isenberg, D., Wallace, D. J., Nived, O., et al. (2012) · Arthritis & Rheumatism · doi:10.1002/art.34473 · Cited by 5,322
van den Hoogen, F., Khanna, D., Fransen, J., Johnson, S. R., Baron, M., Tyndall, A., Matucci‐Cerinic, M., Naden, R. P., Medsger, T. A., Carreira, P. E., et al. (2013) · Arthritis & Rheumatism · doi:10.1002/art.38098 · Cited by 3,409
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Husby, S., Koletzko, S., Korponay‐Szabó, I. R., Mearin, M. L., Phillips, A., Shamir, R., Troncone, R., Giersiepen, K., Branski, D., Catassi, C., et al. (2012) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e31821a23d0 · Cited by 2,683
Development of Autoantibodies before the Clinical Onset of Systemic Lupus Erythematosus
Arbuckle, M. R., McClain, M. T., Rubertone, M. V., Scofield, R. H., Dennis, G. J., James, J. A., & Harley, J. B. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021933 · Cited by 2,578
Kaplan, M. M. (1987) · New England Journal of Medicine · doi:10.1056/nejm198702263160907 · Cited by 1,959
Rantapää‐Dahlqvist, S., de Jong, B. A. W., Berglin, E., Hallmans, G., Wadell, G., Stenlund, H., Sundin, U., & van Venrooij, W. J. (2003) · Arthritis & Rheumatism · doi:10.1002/art.11223 · Cited by 1,953
Simplified criteria for the diagnosis of autoimmune hepatitis
Hennes, E. M., Zeniya, M., Czaja, A. J., Parés, A., Dalekos, G. N., Krawitt, E. L., Bittencourt, P. L., Porta, G., Boberg, K. M., Hofer, H., et al. (2008) · Hepatology · doi:10.1002/hep.22322 · Cited by 1,901
Nielen, M. M. J., van Schaardenburg, D., Reesink, H. W., van de Stadt, R. J., van der Horst‐Bruinsma, I. E., de Koning, M. H. M. T., Habibuw, M. R., Vandenbroucke, J. P., & Dijkmans, B. A. C. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20018 · Cited by 1,861
Shiboski, C. H., Shiboski, S. C., Seror, R., Criswell, L. A., Labetoulle, M., Lietman, T. M., Rasmussen, A., Scofield, H., Vitali, C., Bowman, S. J., et al. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-210571 · Cited by 1,414
Renal-Limited “Lupus-Like” Nephritis: How Much of a Lupus
Maziad, A. S. A., Torrealba, J., Seikaly, M. G., Hassler, J. R., & Hendricks, A. R. (2017) · Case Reports in Nephrology and Dialysis · doi:10.1159/000475493 · Cited by 1,299
(2011) · Encyclopedia of Cancer · doi:10.1007/978-3-642-16483-5_4730 · Cited by 1,240
Kaplan, M. M., & Gershwin, M. E. (2005) · New England Journal of Medicine · doi:10.1056/nejmra043898 · Cited by 1,144
(2015) · Diagnostic Imaging: Gastrointestinal · doi:10.1016/b978-0-323-37755-3.50202-6 · Cited by 811
“Homogeneous” enzyme immunoassay. A new immunochemical technique
Rubenstein, K. E., Schneider, R. S., & Ullman, E. F. (1972) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(72)90570-0 · Cited by 498
IMMUNOASSAY OF ENDOGENOUS PLASMA INSULIN IN MAN
YALOW, R. S., & BERSON, S. A. (1996) · Obesity Research · doi:10.1002/j.1550-8528.1996.tb00274.x · Cited by 460
(2012) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000413582.61110.4a · Cited by 453
Autoimmune type 1 diabetes: resolved and unresolved issues
Notkins, A. L., & Lernmark, Å. (2001) · Journal of Clinical Investigation · doi:10.1172/jci14257 · Cited by 323
Labelled Antibodies and Immunological Assay Systems
MILES, L. E. M., & HALES, C. N. (1968) · Nature · doi:10.1038/219186a0 · Cited by 269
The estimation of thyroxine in human plasma by an electrophoretic technique
Ekins, R. P. (1960) · Clinica Chimica Acta · doi:10.1016/0009-8981(60)90051-6 · Cited by 246
Multianalyte microspot immunoassay--microanalytical "compact disk" of the future
Ekins, R. P., & Chu, F. W. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.11.1955 · Cited by 235
Autoantibodies predate the onset of systemic lupus erythematosus in northern Sweden
Eriksson, C., Kokkonen, H., Johansson, M., Hallmans, G., Wadell, G., & Rantapää-Dahlqvist, S. (2011) · Arthritis Research & Therapy · doi:10.1186/ar3258 · Cited by 231
Autoantibodies Present Before Symptom Onset in Primary Sjögren Syndrome
Jonsson, R. (2013) · JAMA · doi:10.1001/jama.2013.278448 · Cited by 230
Primary biliary cirrhosis once rare, now common in the United Kingdom?
James, O. F., Bhopal, R., Howel, D., Gray, J., Burt, A. D., & Metcalf, J. V. (1999) · Hepatology · doi:10.1002/hep.510300213 · Cited by 213
Mahler, M., Meroni, P.-L., Bossuyt, X., & Fritzler, M. J. (2014) · Journal of Immunology Research · doi:10.1155/2014/315179 · Cited by 203
Tozzoli, R., Bizzaro, N., Tonutti, E., Villalta, D., Bassetti, D., Manoni, F., Piazza, A., Pradella, M., & Rizzotti, P. (2002) · American Journal of Clinical Pathology · doi:10.1309/y5vf-c3dm-l8xv-u053 · Cited by 202
Self-citation(2002) · PubMed · Cited by 191
2010 rheumatoid arthritis classification criteria
Initiative, C. (2010) · Arthritis & Rheumatism · doi:10.14961/cra.23.339 · Cited by 161
Bizzaro, N., Antico, A., Platzgummer, S., Tonutti, E., Bassetti, D., Pesente, F., Tozzoli, R., Tampoia, M., & Villalta, D. (2013) · Autoimmunity Reviews · doi:10.1016/j.autrev.2013.10.015 · Cited by 135
Self-citationTozzoli, R., Kodermaz, G., Perosa, A. R., Tampoia, M., Zucano, A., Antico, A., & Bizzaro, N. (2010) · Autoimmunity Reviews · doi:10.1016/j.autrev.2010.08.006 · Cited by 128
Self-citationDiagnostic criteria of autoimmune hepatitis
Liberal, R., Grant, C. R., Longhi, M. S., Mieli‐Vergani, G., & Vergani, D. (2014) · Autoimmunity Reviews · doi:10.1016/j.autrev.2013.11.009 · Cited by 117
Haugbro, K., Nossent, J. C., Winkler, T., Figenschau, Y., & Rekvig, O. P. (2004) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2003.016303 · Cited by 113
Ebert, T., Chapman, J., & Shoenfeld, Y. (2005) · Lupus · doi:10.1191/0961203305lu2150rr · Cited by 110
Autoantibodies 2015: From diagnostic biomarkers toward prediction, prognosis and prevention
Damoiseaux, J. G. M. C., Andrade, L. E. C., Fritzler, M. J., & Shoenfeld, Y. (2015) · Autoimmunity Reviews · doi:10.1016/j.autrev.2015.01.017 · Cited by 108
Autoimmune diseases in the intensive care unit. An update
Quintero, O. L., Rojas‐Villarraga, A., Mantilla, R. D., & Anaya, J. (2012) · Autoimmunity Reviews · doi:10.1016/j.autrev.2012.06.002 · Cited by 101
Diagnosis and management of thyrotoxicosis
Vaidya, B., & Pearce, S. H. S. (2014) · BMJ · doi:10.1136/bmj.g5128 · Cited by 98
Predicting and Preventing Autoimmunity, Myth or Reality?
Harel, M., & Shoenfeld, Y. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1351.031 · Cited by 92
Autoantibodies as predictors of disease: The clinical and experimental evidence
Bizzaro, N. (2007) · Autoimmunity Reviews · doi:10.1016/j.autrev.2007.01.006 · Cited by 92
Self-citationAre we at a stage to predict autoimmune rheumatic diseases?
Bizzaro, N., Tozzoli, R., & Shoenfeld, Y. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22708 · Cited by 84
Self-citationCurrent state of diagnostic technologies in the autoimmunology laboratory
Tozzoli, R., Bonaguri, C., Melegari, A., Antico, A., Bassetti, D., & Bizzaro, N. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0191 · Cited by 76
Self-citationAntico, A., Platzgummer, S., Bassetti, D., Bizzaro, N., Tozzoli, R., Villalta, D., & Study Group on Autoimmune Diseases of the Italian Society of Laboratory Medicine (SIMeL) (2010) · Lupus · doi:10.1177/0961203310362995 · Cited by 70
Self-citationMähler, M., Radice, A., Yang, W., Bentow, C., Seaman, A., Bianchi, L., & Sinico, R. A. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.01.004 · Cited by 63
The laboratory approach to the diagnosis of autoimmune diseases: Is it time to change?
Villalta, D., Tozzoli, R., Tonutti, E., & Bizzaro, N. (2007) · Autoimmunity Reviews · doi:10.1016/j.autrev.2007.01.009 · Cited by 55
Self-citationThe diagnostic role of autoantibodies in the prediction of organ-specific autoimmune diseases
Tozzoli, R. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.138 · Cited by 44
A homogeneous immunoassay for cyclic nucleotides based on chemiluminescence energy transfer
Campbell, A. K., & Patel, A. R. (1983) · Biochemical Journal · doi:10.1042/bj2160185 · Cited by 44
The Predictive Significance of Autoantibodies in Organ-Specific Autoimmune Diseases
Bizzaro, N. (2007) · Clinical Reviews in Allergy & Immunology · doi:10.1007/s12016-007-8059-5 · Cited by 43
Self-citationBentow, C., Lakos, G., Rosenblum, R. A., Bryant, C., Seaman, A., & Mähler, M. (2014) · Immunologic Research · doi:10.1007/s12026-014-8601-5 · Cited by 42
Antinuclear antibody screening in this new millennium: farewell to the microscope?
Hans Nossent, O. P. R. (2001) · Scandinavian Journal of Rheumatology · doi:10.1080/030097401300162860 · Cited by 42
Infantino, M., Meacci, F., Bentow, C., Martis, P., Benucci, M., Afeltra, A., Rigon, A., Atzeni, F., Sarzi-Puttini, P., Manfredi, M., et al. (2015) · Journal of Immunology Research · doi:10.1155/2015/902821 · Cited by 41
Automation, consolidation, and integration in autoimmune diagnostics
Tozzoli, R., D’Aurizio, F., Villalta, D., & Bizzaro, N. (2015) · Autoimmunity Highlights · doi:10.1007/s13317-015-0067-5 · Cited by 40
Self-citationBentow, C., Lakos, G., Martis, P., Wahl, E., Garcia, M., Viñas, O., Espinosa, G., Cervera, R., Sjöwall, C., Carmona-Fernandes, D., et al. (2016) · Lupus · doi:10.1177/0961203316640917 · Cited by 37
Bentow, C., Swart, A., Wu, J., Seaman, A., Manfredi, M., Infantino, M. G., Benucci, M., Lakos, G., & Mähler, M. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.05.011 · Cited by 37
Protein microarray platform for the multiplex analysis of biomarkers in human sera
Urbanowska, T., Mangialaio, S., Zickler, C., Cheevapruk, S., Hasler, P., Regenass, S., & Legay, F. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.03.019 · Cited by 33
The clinical autoimmunologist and the laboratory autoimmunologist: The two sides of the coin
Tozzoli, R., & Bizzaro, N. (2012) · Autoimmunity Reviews · doi:10.1016/j.autrev.2012.02.011 · Cited by 32
Self-citationAnti-dsDNA antibody testing in the clinic: Farr or ELISA?
Mähler, M., & Fritzler, M. J. (2007) · Nature Clinical Practice Rheumatology · doi:10.1038/ncprheum0398 · Cited by 29
Lakos, G., Norman, G. L., Mähler, M., Martis, P., Bentow, C., Santora, D., & Fasano, A. (2014) · Journal of Immunology Research · doi:10.1155/2014/371263 · Cited by 29
Cinquanta, L., Bizzaro, N., Villalta, D., Morozzi, G., Tonutti, E., Bagnasco, M., Pesce, G., Bassetti, D., Porcelli, B., Terzuoli, L., et al. (2015) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-015-0099-x · Cited by 19
Self-citationRecent advances in diagnostic technology: applications in autoimmune and infectious diseases.
Lalvani, A., Meroni, P. L., Millington, K. A., Modolo, M. L., Plebani, M., Tincani, A., Villalta, D., Doria, A., & Ghirardello, A. (2008) · PubMed · Cited by 19
A new oligonucleotide-based ELISA for the detection of anti-double-stranded DNA antibodies
Radice, A., & Sinico, R. A. (2005) · Autoimmunity · doi:10.1080/08916930500448422 · Cited by 16
Detection of autoantibodies in a point-of-care rheumatology setting
Konstantinov, K. N., Tzamaloukas, A. H., & Rubin, R. L. (2013) · Autoimmunity Highlights · doi:10.1007/s13317-013-0052-9 · Cited by 15
Gelpí, C., Pérez, E., & Roldán, C. (2014) · Autoimmunity Highlights · doi:10.1007/s13317-014-0059-x · Cited by 12
Indagine conoscitiva sull’attività dei Laboratori italiani di autoimmunologia—anno 2012
della SIMeL, G. D. S. I. A., Bizzaro, N., Tozzoli, R., et al. (2014) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-014-0070-2 · Cited by 3
Self-citationQuanto e come vengono applicate le linee guida in Autoimmunologia nei Laboratori italiani?
Porcelli, B., Cinquanta, L., Barberio, G., Sorrentino, M. C., Brusca, I., & Bizzaro, N. (2016) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-016-0134-6 · Cited by 2
Self-citation
Cited by
Safiabadi Tali, S. H., LeBlanc, J. J., Sadiq, Z., Oyewunmi, O. D., Camargo, C., Nikpour, B., Armanfard, N., Sagan, S. M., & Jahanshahi-Anbuhi, S. (2021) · Clinical Microbiology Reviews · doi:10.1128/cmr.00228-20 · Cited by 405
Fluid biomarkers in Alzheimer's disease
Simrén, J., Elmgren, A., Blennow, K., & Zetterberg, H. (2023) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2022.09.006 · Cited by 58
Metadata
- Authors
- Cinquanta, L., Fontana, D. E., & Bizzaro, N.
- Venue
- Autoimmunity Highlights
- Published
- 2017-06-24
- Volume
- 8
- Issue
- 1
- Pages
- 9-9
- ISSN
- 2038-0305 (ISSN-L)
- 2038-3274
- OpenAlex
- W2722513105
- Cited by
- 287
- References
- 64
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.