Reliable Determinations of Protein–Ligand Interactions by Direct ESI-MS Measurements. Are We There Yet?
The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
The association-dissociation of noncovalent interactions between protein and ligands, such as other proteins, carbohydrates, lipids, DNA, or small molecules, are critical events in many biological processes. The discovery and characterization of these interactions is essential to a complete understanding of biochemical reactions and pathways and to the design of novel therapeutic agents that may be used to treat a variety of diseases and infections. Over the last 20 y, electrospray ionization mass spectrometry (ESI-MS) has emerged as a versatile tool for the identification and quantification of protein-ligand interactions in vitro. Here, we describe the implementation of the direct ESI-MS assay for the determination of protein-ligand binding stoichiometry and affinity. Additionally, we outline common sources of error encountered with these measurements and various strategies to overcome them. Finally, we comment on some of the outstanding challenges associated with the implementation of the assay and highlight new areas where direct ESI-MS measurements are expected to make significant contributions in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An Update
Hunter, E. P. L., & Lias, S. G. (1998) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.556018 · Cited by 2,702 · cited 1×
“Additionally, the use of imidazole, which has a relatively high gas phase basicity and a relatively low gas phase acidity [53, 54], may also lead to a reduction in the charge states of the protein complex ions.”
BackgroundDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613 · cited 1×
“The formation of nonspecific PL complexes can be understood in the context of the charge residue model of ESI (Figure 2) [58].”
BackgroundStudying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182 · cited 1×
“Another method for the analysis of protein–ligand interactions in solution, which is the focus of the present article, is based on direct electrospray ionization mass spectrometry (ESI-MS) measurements [7–10].”
MethodNMR Spectroscopy Techniques for Screening and Identifying Ligand Binding to Protein Receptors
Meyer, B., & Peters, T. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390233 · Cited by 1,039 · cited 1×
“The most common techniques for quantifying protein–ligand binding in vitro include surface plasmon resonance (SPR) spectroscopy [1], isothermal titration calorimetry (ITC) [2], frontal affinity chromatography combined with mass spectrometry detection [3], enzymelinked immunosorbent assay [4], ThermoFluor assay [5] and…”
MethodOptical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015 · cited 1×
“The most common techniques for quantifying protein–ligand binding in vitro include surface plasmon resonance (SPR) spectroscopy [1], isothermal titration calorimetry (ITC) [2], frontal affinity chromatography combined with mass spectrometry detection [3], enzymelinked immunosorbent assay [4], ThermoFluor assay [5] and…”
MethodDetermining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655 · cited 1×
“A variety of strategies have been proposed for ESI-MS analysis of solutions containing physiological buffers at relevant concentrations, including the use of high ammonium acetate concentrations [76, 77], carrying out ESI in the presence of high velocity air (gas) [78], and decoupling the sample solution from the ESI…”
MethodInvestigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583 · cited 1×
“Another method for the analysis of protein–ligand interactions in solution, which is the focus of the present article, is based on direct electrospray ionization mass spectrometry (ESI-MS) measurements [7–10].”
MethodMatulis, D., Kranz, J. K., Salemme, F. R., & Todd, M. J. (2005) · Biochemistry · doi:10.1021/bi048135v · Cited by 495 · cited 1×
“The most common techniques for quantifying protein–ligand binding in vitro include surface plasmon resonance (SPR) spectroscopy [1], isothermal titration calorimetry (ITC) [2], frontal affinity chromatography combined with mass spectrometry detection [3], enzymelinked immunosorbent assay [4], ThermoFluor assay [5] and…”
MethodKatta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475 · cited 1×
“In 1991, Katta and Chait reported on the ESI-MS detection of the intact globin– heme interaction of myoglobin [11].”
BackgroundDaniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475 · cited 1×
“Another method for the analysis of protein–ligand interactions in solution, which is the focus of the present article, is based on direct electrospray ionization mass spectrometry (ESI-MS) measurements [7–10].”
Method
Cited by
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
Biophysics in drug discovery: impact, challenges and opportunities
Renaud, J.-P., Chung, C.-W., Danielson, U. H., Egner, U., Hennig, M., Hubbard, R. E., & Nar, H. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.123 · Cited by 382
Sialic acid-containing glycolipids mediate binding and viral entry of SARS-CoV-2
Nguyen, L., McCord, K. A., Bui, D. T., Bouwman, K. M., Kitova, E. N., Elaish, M., Kumawat, D., Daskhan, G. C., Tomris, I., Han, L., et al. (2022) · Nature Chemical Biology · doi:10.1038/s41589-021-00924-1 · Cited by 259
Self-citationKonermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Liu, X. R., Zhang, M. M., & Gross, M. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00815 · Cited by 242
Twenty Years of Gas Phase Structural Biology
Marcoux, J., & Robinson, C. V. (2013) · Structure · doi:10.1016/j.str.2013.08.002 · Cited by 158
Epsin and Sla2 form assemblies through phospholipid interfaces
Garcia-Alai, M. M., Heidemann, J., Skruzny, M., Gieras, A., Mertens, H. D. T., Svergun, D. I., Kaksonen, M., Uetrecht, C., & Meijers, R. (2018) · Nature Communications · doi:10.1038/s41467-017-02443-x · Cited by 52
Recognition of human milk oligosaccharides by bacterial exotoxins
El-Hawiet, A., Kitova, E. N., & Klassen, J. S. (2015) · Glycobiology · doi:10.1093/glycob/cwv025 · Cited by 51
“In the present work, the direct electrospray ionization mass spectrometry (ESI-MS) assay (El-Hawiet et al. 2012; Kitova et al. 2012) was used to quantify the binding of twenty commercially available HMOs to CTB5, HLTB5, Stx1B5 and Stx2 in neutral aqueous solutions at 25 °C. Results and discussion…”
MethodSelf-citationPfoh, R., Subramanian, A. S., Huang, J., Little, D. J., Forman, A., DiFrancesco, B. R., Balouchestani-Asli, N., Kitova, E. N., Klassen, J. S., Pomès, R., et al. (2022) · PLOS Pathogens · doi:10.1371/journal.ppat.1010750 · Cited by 17
Self-citationCanzani, D., Rusnac, D.-V., Zheng, N., & Bush, M. F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02331 · Cited by 11
(2023) · doi:10.32920/24746796 · Cited by 1
Pfoh, R., Subramanian, A. S., Huang, J., Little, D., Forman, A., DiFrancesco, B. R., Balouchestani-Asli, N., Kitova, E. N., Klassen, J. S., Pomès, R., et al. (2023) · doi:10.32920/24746796.v1
Self-citation
Metadata
- Authors
- Kitova, E. N., El-Hawiet, A., Schnier, P. D., & Klassen, J. S.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-21
- Volume
- 23
- Issue
- 3
- Pages
- 431-441
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2073317392
- Cited by
- 237
- References
- 72
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.