Boundaries of Mass Resolution in Native Mass Spectrometry
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)-protein interactions, to nanomachineries such as the proteasome and ribosome, to even virus assembly. In native MS, ions attain high m/z values, requiring special mass analyzers for their detection. Depending on the particular mass analyzer used, instrumental mass resolution does often decrease at higher m/z but can still be above a couple of thousand at m/z 5000. However, the mass resolving power obtained on charge states of protein complexes in this m/z region is experimentally found to remain well below the inherent instrument resolution of the mass analyzers employed. Here, we inquire into reasons for this discrepancy and ask how native MS would benefit from higher instrumental mass resolution. To answer this question, we discuss advantages and shortcomings of mass analyzers used to study intact biomolecules and biomolecular complexes in their native state, and we review which other factors determine mass resolving power in native MS analyses. Recent examples from the literature are given to illustrate the current status and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 4×
“Efficiency of desolvation in the ESI process, i. e. adduct removal from the analyte.”
InfluentialNative mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766 · cited 1×
“Next to its eminent role in peptide sequencing and proteomics, MS has evolved as a valuable tool to study structures, interactions, and dynamics of protein complexes [15–17].”
Self-citationA Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 3×
“This is also illustrated in Figure 3, where we simulate the 26+ charge state of a 150 kDa “averagine” protein (1350 averagine residues [61]) in its unmodified, ammonium-bound, and sodium-bound form.”
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Self-citationDynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194 · cited 1×
“In fact, Makarov and Denisov deduced that fragmenting and nonfragmenting collisions are the main reasons for ion loss within the Orbitrap [46].”
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175 · cited 1×
“Using an Orbitrap Q-Exactive with extended mass range, pyruvate kinase fragment ions with a maximum mass of 11,000 Da could be isotopically resolved by native top-down MS [50].”
Allosteric mechanisms can be distinguished using structural mass spectrometry
Dyachenko, A., Gruber, R., Shimon, L., Horovitz, A., & Sharon, M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1302395110 · Cited by 144 · cited 10×
“Although the inherent instrument resolution is the same in each case, we encountered substantial differences for the apparent resolution: R nat in the simulation, where only ‘bare’ GroEL ions are considered, is two–three times higher than in the experimental QTOF or Orbitrap spectra.”
InfluentialValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers
Shaw, J. B., & Brodbelt, J. S. (2013) · Analytical Chemistry · doi:10.1021/ac401634b · Cited by 28
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationBest practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Nguyen, G. T. H., Bennett, J. L., Liu, S., Hancock, S. E., Winter, D. L., Glover, D. J., & Donald, W. A. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c10408 · Cited by 66
Mikhailov, V. A., Griffiths, R. L., & Cooper, H. J. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.09.011 · Cited by 41
“To date, mass spectra of intact complexes as large as 18 MDa (an entire capsid assembly of bacteriophage HK97) have been reported [22], although the mass resolution of such large species is limited by incomplete desolvation of their gas-phase ions rather than by the inherent instrument resolution of the mass analysers…”
Background
Metadata
- Authors
- Lössl, P., Snijder, J., & Heck, A. J. R.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-04-04
- Volume
- 25
- Issue
- 6
- Pages
- 906-917
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2117968689
- Cited by
- 136
- References
- 10
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Boundaries of Mass Resolution in Native Mass Spectrometry. https://app.cochat.ai/papers/10.1007/s13361-014-0874-3
- The paper
- Lössl, P., Snijder, J., & Heck, A. J. R. (2014). Boundaries of Mass Resolution in Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-014-0874-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.