A review of low-intensity focused ultrasound for neuromodulation
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 1×
“At low intensities, for instance, reversible cellular effects can potentially be produced, whereas high-intensity ultrasound can lead to irreversible cell death through coagulative necrosis [1, 64].”
BackgroundNoninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977 · cited 1×
“1 C) have been observed during the course of US neuromodulation [5, 24, 38, 40, 52].”
BackgroundDeep Brain Stimulation for Parkinson Disease: An Expert Consensus and Review of Key Issues
Bronstein, J. M., Tagliati, M., Alterman, R. L., Lozano, A. M., Volkmann, J., Stefani, A., Horak, F. B., Okun, M. S., Foote, K. D., Krack, P., et al. (2011) · Archives of Neurology · doi:10.1001/archneurol.2010.260 · Cited by 971 · cited 1×
“DBS technique, for example, requires a surgical procedure that causes risk of infection and immune responses [16].”
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707 · cited 3×
“In 2008, a ground-breaking work was published by Tyler group showing that US is capable of generating action potentials (APs) in central neurons, intracellular influx of Ca2? and Na? ions, and potentiated synaptic transmissions in CNS [23].”
BackgroundFocused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613 · cited 4×
“Activation as well as selective suppression effects of LIFU on craniotomized rabbit brain function were confirmed by the results obtained from electrophysiology and fMRI studies [5].”
BackgroundInfluentialMR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70048-6 · Cited by 604 · cited 1×
“brain studies, for example, a number of clinical trials have been performed to study the feasibility of HIFU in the treatment of essential tremor and neuropathic pain [3, 4].”
BackgroundIntramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550 · cited 4×
“Another possible mechanism underlying the ability of US to modulate the brain function is due to the presence of acoustic cavitation within the bilayer membrane [55, 56].”
BackgroundInfluential
Cited by
Injectable and biodegradable piezoelectric hydrogel for osteoarthritis treatment
Vinikoor, T., Dzidotor, G. K., Le, T. T., Liu, Y., Kan, H.-M., Barui, S., Chorsi, M. T., Curry, E. J., Reinhardt, E., Wang, H., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-41594-y · Cited by 344
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Huang, L., Kang, J., Chen, G., Ye, W., Meng, X., Du, Q., & Feng, Z. (2022) · Aging · doi:10.18632/aging.204290 · Cited by 23
Metadata
- Authors
- Baek, H., Pahk, K. J., & Kim, H.
- Venue
- Biomedical Engineering Letters
- Published
- 2017-01-09
- Volume
- 7
- Issue
- 2
- Pages
- 135-142
- ISSN
- 2093-985X (ISSN-L)
- 2093-9868
- OpenAlex
- W2568559291
- Cited by
- 184
- References
- 62
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.