A review of low-intensity focused ultrasound for neuromodulation
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 1×
“At low intensities, for instance, reversible cellular effects can potentially be produced, whereas high-intensity ultrasound can lead to irreversible cell death through coagulative necrosis [1, 64].”
BackgroundNoninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977 · cited 1×
“1 C) have been observed during the course of US neuromodulation [5, 24, 38, 40, 52].”
BackgroundDeep Brain Stimulation for Parkinson Disease: An Expert Consensus and Review of Key Issues
Bronstein, J. M., Tagliati, M., Alterman, R. L., Lozano, A. M., Volkmann, J., Stefani, A., Horak, F. B., Okun, M. S., Foote, K. D., Krack, P., et al. (2011) · Archives of Neurology · doi:10.1001/archneurol.2010.260 · Cited by 971 · cited 1×
“DBS technique, for example, requires a surgical procedure that causes risk of infection and immune responses [16].”
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707 · cited 3×
“In 2008, a ground-breaking work was published by Tyler group showing that US is capable of generating action potentials (APs) in central neurons, intracellular influx of Ca2? and Na? ions, and potentiated synaptic transmissions in CNS [23].”
BackgroundFocused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613 · cited 4×
“Activation as well as selective suppression effects of LIFU on craniotomized rabbit brain function were confirmed by the results obtained from electrophysiology and fMRI studies [5].”
BackgroundInfluentialMR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70048-6 · Cited by 604 · cited 1×
“brain studies, for example, a number of clinical trials have been performed to study the feasibility of HIFU in the treatment of essential tremor and neuropathic pain [3, 4].”
BackgroundIntramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550 · cited 4×
“Another possible mechanism underlying the ability of US to modulate the brain function is due to the presence of acoustic cavitation within the bilayer membrane [55, 56].”
BackgroundInfluentialScanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491 · cited 2×
“US parameters are needed to be refined in order to explore potential therapeutic applications since the evoked neuronal responses have only been observed in superficially anesthetized animals [25, 30].”
BackgroundPhysical mechanisms of the therapeutic effect of ultrasound (a review)
Bailey, M. R., Khokhlova, V. A., Sapozhnikov, O. A., Kargl, S. G., & Crum, L. A. (2003) · Acoustical Physics · doi:10.1134/1.1591291 · Cited by 465 · cited 1×
“tation, and is a threshold effect, which depends acoustic pressure, temperature and insonation frequency [60, 61].”
BackgroundThe mechanobiology of brain function
Tyler, W. J. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3383 · Cited by 420
Transcranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415 · cited 1×
“[49] also reported that LIFU-mediated primary visual cortex (V1) stimulation could result in US-evoked potentials and elevated fMRI blood oxygen level-dependent (BOLD) signals in not only V1 but also associated network region functionally connected with the exposed area.”
BackgroundSelf-citationImage-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S. (2015) · Scientific Reports · doi:10.1038/srep08743 · Cited by 414
Self-citationA review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409 · cited 1×
“[25, 62], to the best of our knowledge, no in vivo evidence validating the presence of intramembrane cavitation at low US intensities in an animal model has been published [10, 63].”
BackgroundUltrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353 · cited 1×
“[54] experimentally observed the activation of voltage-gated sodium Na, calcium Ca and potassium K channels during FUS exposure.”
BackgroundProduction of Reversible Changes in the Central Nervous System by Ultrasound
Fry, F. J., Ades, H. W., & Fry, W. J. (1958) · Science · doi:10.1126/science.127.3289.83 · Cited by 339 · cited 1×
“[6] observed that transmitted FUS to lateral geniculate nucleus (LGN) of craniotomized cats led to partial suppression in electrophysiological responses recorded from the primary visual cortex, and Mazoue et al.”
BackgroundFocused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters
Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.06.011 · Cited by 304 · cited 2×
“A number of studies reported that US at intensities below the FDA limits was able to modulate the neural activity with no signs of tissue damage in the brain [5, 30, 66] Acoustic intensities higher than the FDA limit but lower than the upper limit set by the International Electrotechnical Commission (IEC) for diagnost…”
BackgroundSelf-citationMonti, M. M., Schnakers, C., Korb, A. S., Bystritsky, A., & Vespa, P. M. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.07.008 · Cited by 280 · cited 1×
“LIFU to wake up a post-traumatic disorder of consciousness (DOC) patient [12], which was consistent with the”
Ultrasound Biosafety Considerations for the Practicing Sonographer and Sonologist
Nelson, T. R., Fowlkes, J. B., Abramowicz, J. S., & Church, C. C. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.2.139 · Cited by 279 · cited 2×
“For the sake of safety, the FDA currently stipulates the maximum allowed acoustic output level of diagnostic US system that [65, 67].”
BackgroundLiu, H.-L., Fan, C.-H., Ting, C.-Y., & Yeh, C.-K. (2014) · Theranostics · doi:10.7150/thno.8074 · Cited by 276
Plaksin, M., Kimmel, E., & Shoham, S. (2016) · eneuro · doi:10.1523/eneuro.0136-15.2016 · Cited by 268 · cited 1×
“[25, 62], to the best of our knowledge, no in vivo evidence validating the presence of intramembrane cavitation at low US intensities in an animal model has been published [10, 63].”
BackgroundTranscranial Ultrasound (TUS) Effects on Mental States: A Pilot Study
Hameroff, S., Trakas, M., Duffield, C., Annabi, E., Gerace, M. B., Boyle, P., Lucas, A., Amos, Q., Buadu, A., & Badal, J. J. (2013) · Brain stimulation · doi:10.1016/j.brs.2012.05.002 · Cited by 248 · cited 1×
“[45] reported improvement in subjective mood and pain reduction after transcranial US compared to placebo, when applying high-frequency US (8 MHz) for 15 s to the scalp over posterior frontal cortex.”
MethodPrecise Neural Stimulation in the Retina Using Focused Ultrasound
Menz, M. D., Oralkan, Ö., Khuri-Yakub, P. T., & Baccus, S. A. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.3521-12.2013 · Cited by 230 · cited 1×
“1 C) have been observed during the course of US neuromodulation [5, 24, 38, 40, 52].”
BackgroundImage-Guided Focused Ultrasound-Mediated Regional Brain Stimulation in Sheep
Lee, W., Lee, S. D., Park, M. Y., Foley, L., Purcell-Estabrook, E., Kim, H., Fischer, K., Maeng, L.-S., & Yoo, S.-S. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.10.001 · Cited by 218 · cited 1×
“Further evidence was discovered from large animal experiments showing that FUS sonication on primary sensorimotor (SM1) and visual (V1) region in sheep can elicit electromyographic responses from contralateral hind leg and electroencephalographic potentials, respectively [32].”
BackgroundSelf-citationTranscranial Focused Ultrasound Modulates Intrinsic and Evoked EEG Dynamics
Mueller, J., Legon, W., Opitz, A., Sato, T. F., & Tyler, W. J. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.08.008 · Cited by 214 · cited 1×
“A more standardized human study was conducted to modulate the function of primary somatosensory cortex (S1) and found slight but significant changes in EEG responses [46] with the enhancement of the discrimination ability [47].”
BackgroundYounan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204
Medical and non-medical protection standards for ultrasound and infrasound
Duck, F. A. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.008 · Cited by 187 · cited 1×
“Ispta of 3 W/cm (2), [68]) have also been used to stimulate brain function.”
MethodIncreased Anatomical Specificity of Neuromodulation via Modulated Focused Ultrasound
Mehić, E., Xu, J. M., Caler, C. J., Coulson, N. K., Moritz, C. T., & Mourad, P. D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086939 · Cited by 174
Application of focused ultrasound for the stimulation of neural structures
Gavrilov, L. R., Tsirulnikov, E. M., & Davies, I. A. I. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(96)83782-3 · Cited by 173 · cited 13×
“Although this hypothesis has not been directly tested yet, Tyler et al. [23] and Kubanek et al. [54] experimentally observed the activation of voltage-gated sodium Na?, calcium Ca?? and potassium K? channels during FUS exposure.”
BackgroundInfluentialTHE EFFECT OF HIGH FREQUENCY SOUND WAVES ON HEART MUSCLE AND OTHER IRRITABLE TISSUES
Harvey, E. N. (1929) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1929.91.1.284 · Cited by 172 · cited 1×
“In 1928, the feasibility of using ultrasound to stimulate peripheral nervous system through experimenting with ex vivo frog and turtle neuromuscular preparations was firstly reported by Harvey [33].”
BackgroundFocused Ultrasound Effects on Nerve Action Potential in vitro
Colucci, V., Strichartz, G., Jolesz, F., Vykhodtseva, N., & Hynynen, K. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.05.002 · Cited by 169 · cited 1×
“[36] attempted to use FUS to block the nerve conduction”
MethodLee, W., Chung, Y. A., Jung, Y., Song, I.-U., & Yoo, S.-S. (2016) · BMC Neuroscience · doi:10.1186/s12868-016-0303-6 · Cited by 159 · cited 1×
“In addition, they further investigated the various tactile sensations while simultaneously stimulating S1 and S2 in the later study [48].”
BackgroundProgress and Problems in the Neurological Applications of Focused Ultrasound
Ballantine, H. T., Bell, E., & Manlapaz, J. S. (1960) · Journal of neurosurgery · doi:10.3171/jns.1960.17.5.0858 · Cited by 146
Localization of Ultrasound-Induced In Vivo Neurostimulation in the Mouse Model
King, R. L., Brown, J., & Butts, K. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.01.020 · Cited by 144
Mihran, R. T., Barnes, F. S., & Wachtel, H. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90008-z · Cited by 138 · cited 1×
“In the 1990s, experiments were conducted on the response of electrical excitability of myelinated frog sciatic nerve in vitro [34, 35], which showed that US could increase or even decrease the compound action potential (CAP) amplitudes.”
BackgroundReview Paper: A Review on Brain Stimulation Using Low Intensity Focused Ultrasound
Rezayat, E., & Toostani, I. G. (2016) · Basic and Clinical Neuroscience Journal · doi:10.15412/j.bcn.03070303 · Cited by 135 · cited 1×
“[25, 62], to the best of our knowledge, no in vivo evidence validating the presence of intramembrane cavitation at low US intensities in an animal model has been published [10, 63].”
BackgroundNeuromodulation accompanying focused ultrasound-induced blood-brain barrier opening
Chu, P.-C., Liu, H.-L., Lai, H.-Y., Lin, C.-Y., Tsai, H.-C., & Pei, Y.-C. (2015) · Scientific Reports · doi:10.1038/srep15477 · Cited by 127
Acoustic cavitation series: part one
Neppiras, E. A. (1984) · Ultrasonics · doi:10.1016/0041-624x(84)90057-x · Cited by 125
Noninvasive Transcranial Stimulation of Rat Abducens Nerve by Focused Ultrasound
Kim, H., TAGHADOS, S. J., Fischer, K., Maeng, L., Park, S., & Yoo, S. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.04.023 · Cited by 120 · cited 2×
“1 C) have been observed during the course of US neuromodulation [5, 24, 38, 40, 52].”
BackgroundSelf-citationTranscranial focused ultrasound to the thalamus alters anesthesia time in rats
Yoo, S., Kim, H., Min, B., Franck, E., & Park, S. (2011) · Neuroreport · doi:10.1097/wnr.0b013e32834b2957 · Cited by 119 · cited 2×
“animal study showing the effectiveness of thalamic-LIFU to promote recovery from ketamine/xylazine-induced anesthesia in rodents [31].”
BackgroundSelf-citationYang, P. S., Kim, H., Lee, W., Böhlke, M., Park, S., Maher, T. J., & Yoo, S. (2012) · Neuropsychobiology · doi:10.1159/000336001 · Cited by 114
Self-citationRinaldi, P. C., Jones, J. P., Reines, F., & Price, L. R. (1991) · Brain Research · doi:10.1016/0006-8993(91)90711-4 · Cited by 99 · cited 1×
“Later on, several studies demonstrated the effect of US on the neural fibers in hippocampal slice cultures and mammalian brains for temporally altering bioelectrical activities [11, 18, 19].”
BackgroundMin, B., Yang, P. S., Böhlke, M., Park, S., Vago, D. R., Maher, T. J., & Yoo, S. (2011) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20284 · Cited by 98
Focused Ultrasound Modifications of Neural Circuit Activity in a Mammalian Brain
Bachtold, M. R., Rinaldi, P. C., Jones, J. P., Reines, F., & Price, L. R. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00014-3 · Cited by 94 · cited 1×
“Later on, several studies demonstrated the effect of US on the neural fibers in hippocampal slice cultures and mammalian brains for temporally altering bioelectrical activities [11, 18, 19].”
BackgroundNaor, O., Hertzberg, Y., Zemel, E., Kimmel, E., & Shoham, S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026006 · Cited by 79 · cited 2×
“A number of studies reported that US at intensities below the FDA limits was able to modulate the neural activity with no signs of tissue damage in the brain [5, 30, 66] Acoustic intensities higher than the FDA limit but lower than the upper limit set by the International Electrotechnical Commission (IEC) for diagnost…”
BackgroundJuan, E. J., González, R., Albors, G., Ward, M. P., & Irazoqui, P. (2014) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22080 · Cited by 78 · cited 1×
“conduction velocity with respect to time [39].”
Image-Guided High-Intensity Focused Ultrasound for Conduction Block of Peripheral Nerves
Foley, J. L., Little, J. W., & Vaezy, S. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9162-0 · Cited by 78 · cited 1×
“[37] FUS on rabbit sciatic nerves successfully led to the nerve conduction blockage followed by the axonal degeneration distal to the sonication site, which was confirmed by electrophysiological and histological analysis.”
MethodModulation of the functional state of the brain with the aid of focused ultrasonic action
Velling, V. A., & Sp, S. (1988) · Neuroscience and Behavioral Physiology · doi:10.1007/bf01193880 · Cited by 69 · cited 1×
“Sonication at low intensities (1–100 mW/cm(2)) led to activation of the bioelectrical activity in the brain, whereas higher intensities (1–100 W/cm(2)) caused a decrease in the electrocorticogram (ECoG) amplitude [21].”
BackgroundReversible Block of Nerve Conduction by Ultrasound: Ultrasonic Blocking of Nerve Fibers
Young, R. R. (1961) · Archives of Neurology · doi:10.1001/archneur.1961.00450070085009 · Cited by 58 · cited 1×
“In the 1990s, experiments were conducted on the response of electrical excitability of myelinated frog sciatic nerve in vitro [34, 35], which showed that US could increase or even decrease the compound action potential (CAP) amplitudes.”
BackgroundUltrasonic stimulation of peripheral nervous tissue: an investigation into mechanisms
Wright, C. J., Rothwell, J. C., & Saffari, N. (2015) · Journal of Physics Conference Series · doi:10.1088/1742-6596/581/1/012003 · Cited by 54 · cited 2×
“1 C) have been observed during the course of US neuromodulation [5, 24, 38, 40, 52].”
BackgroundFocused ultrasound as a tool to input sensory information to humans (Review)
Gavrilov, L. R., & Tsirulnikov, E. M. (2012) · Acoustical Physics · doi:10.1134/s1063771012010083 · Cited by 48 · cited 1×
“The threshold values of different types of sensations measured by acoustic intensity were found to be dependent on US frequency and the location of sonicated region [43, 44].”
BackgroundFocused ultrasound as a non-invasive intervention for neurological disease: a review
Piper, R. J., Hughes, M. A., MORAN, C. M., & Kandasamy, J. (2016) · British Journal of Neurosurgery · doi:10.3109/02688697.2016.1173189 · Cited by 48
THE ACTIONS OF ULTRASOUND ON THE MYELINATED NERVE, THE SPINAL CORD AND THE BRAIN
Takagi, S. F., Higashino, S., Shibuya, T., & Osawa, N. (1960) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.10.183 · Cited by 41 · cited 1×
“Later on, several studies demonstrated the effect of US on the neural fibers in hippocampal slice cultures and mammalian brains for temporally altering bioelectrical activities [11, 18, 19].”
BackgroundEarly ultrasonic effects upon mammalian CNS structures (chemical synapses)
Borrelli, M. J., Bailey, K., & DUNN, F. L. (1981) · The Journal of the Acoustical Society of America · doi:10.1121/1.385791 · Cited by 39 · cited 1×
“Though heating due to absorption of acoustic energy may suppress neuronal activity by disrupting synaptic signalling pathways [51], only minimal increases in temperature (less than 0.”
BackgroundPahk, K. J., Mohammad, G. H., Malagó, M., Saffari, N., & Dhar, D. K. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.03.020 · Cited by 37 · cited 1×
“FUS at high intensities, known as high-intensity focused ultrasound (HIFU), has been used to thermally ablate or mechanically fractionate soft tissues [1, 2].”
BackgroundSelf-citationLee, W., Kim, H., Lee, S., Yoo, S., & Chung, Y. A. (2014) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22091 · Cited by 35 · cited 1×
“The threshold values of different types of sensations measured by acoustic intensity were found to be dependent on US frequency and the location of sonicated region [43, 44].”
BackgroundSelf-citationTang, L. P., Lü, Y., Zheng, W., & Li, Y. (2014) · Journal of Molecular Neuroscience · doi:10.1007/s12031-013-0204-4 · Cited by 21
Distinguishing different fictional worlds during sentence comprehension: ERP evidence
Yang, J., & Xue, J. (2013) · Psychophysiology · doi:10.1111/psyp.12149 · Cited by 18
Koroleva, V. I., Vykhodtseva, N. I., & Elagin, V. A. (1986) · PubMed · Cited by 14
Cited by
Injectable and biodegradable piezoelectric hydrogel for osteoarthritis treatment
Vinikoor, T., Dzidotor, G. K., Le, T. T., Liu, Y., Kan, H.-M., Barui, S., Chorsi, M. T., Curry, E. J., Reinhardt, E., Wang, H., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-41594-y · Cited by 344
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Huang, L., Kang, J., Chen, G., Ye, W., Meng, X., Du, Q., & Feng, Z. (2022) · Aging · doi:10.18632/aging.204290 · Cited by 23
Metadata
- Authors
- Baek, H., Pahk, K. J., & Kim, H.
- Venue
- Biomedical Engineering Letters
- Published
- 2017-01-09
- Volume
- 7
- Issue
- 2
- Pages
- 135-142
- ISSN
- 2093-985X (ISSN-L)
- 2093-9868
- OpenAlex
- W2568559291
- Cited by
- 184
- References
- 62
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.