Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The Holter monitor, the most frequently used diagnostic test in patients with syncope, is nondiagnostic in over 90% of cases. This study sought to determine the impact of a new noninvasive device, the cardiac loop electrocardiographic (ECG) recorder, after Holter monitoring in 57 patients with unexplained syncope. All patients underwent a standardized evaluation protocol and were the monitor for up to 1 month. In 14 patients, loop recording definitively determined whether an arrhythmia was the cause of symptoms (diagnostic yield 25%; 95% confidence intervals 14 to 38%). Diagnoses included unsuspected ventricular tachycardia (1 patient), high grade atrioventricular block (2 patients), supraventricular tachycardia (1 patient), asystole or junctional bradycardia from neurally mediated syncope (3 patients) and normal cardiac rhythms (the remaining 7 patients). Follow-up of all patients diagnosed as having nonarrhythmic syncope by loop recording showed that none of these patients died suddenly. Cardiac loop ECG recording is an important new diagnostic test in patients with syncope unexplained by Holter monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Linzer et al. reported that the diagnostic rate of Holter ECG for syncope was only about 10% [12].”
From Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms (2017) · cites this paper as [12]
In the citing paper
“External loop recorders can be useful in patients with relatively frequent syncope episodes. 166-168”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [167]
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Almquist, A., Goldenberg, I. F., Milstein, S., Chen, M.-Y., Chen, X., Hansen, R., Gornick, C. C., & Benditt, D. G. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200603 · Cited by 651
Isoproterenol induction of vasodepressor-type reaction in vasodepressor-prone persons
Waxman, M. B., Yao, L., Cameron, D. A., Wald, R. W., & Roseman, J. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)91076-x · Cited by 257
Patients With Syncope Admitted to Medical Intensive Care Units
Silverstein, M. D. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330100023024 · Cited by 256
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
Gulamhusein, S., Naccarelli, G. V., Ko, P. T., Prystowsky, E. N., Zipes, D. P., Barnett, H. J. M., Heger, J. J., & Klein, G. J. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90413-2 · Cited by 177
Fujimura, O., Yee, R., Klein, G. J., Sharma, A. D., & Boahene, K. A. (1989) · New England Journal of Medicine · doi:10.1056/nejm198912213212503 · Cited by 158
Role of Cardiac Electrophysiologic Studies in Patients with Unexplained Recurrent Syncope
AKHTAR, M., SHENASA, M., DENKER, S., GILBERT, C. J., & RIZWI, N. (1983) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1983.tb04346.x · Cited by 132
The value of electrophysiologic studies in syncope of undetermined origin: Report of 150 cases
Teichman, S. L., Felder, S. D., Matos, J. A., Kim, S. G., Waspe, L. E., & Fisher, J. D. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90171-1 · Cited by 114
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Research works printed but not linked: 2
- Gendelman, 1983, Syncope in a general hospital patient population, NY State Med J, 83, 1161
- Westveer, 1984, The role of eleclrophysiologic studies in the evaluation of recurrent, unexplained syncope, Cardiovasc Rev Rep, 5, 770
Cited by
Items 101–200 of 254
Utility of patient-activated cardiac event recorders in the detection of cardiac arrhythmias
Wu, C.-C., Hsieh, M.-H., Tai, C.-T., Chiang, C.-E., Yu, W.-C., Lin, Y.-K., Tsao, H.-M., Ding, P. Y.-A., & Chen, S.-A. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1023604816368 · Cited by 27
“Previous studies had similar low incidence of bradyarrhythmias (4%) [7,9].”
ResultGuía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 29
Management of vasovagal syncope: 2004
Sheldon, R. S., Morillo, C. A., & Krahn, A. D. (2004) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2.6.915 · Cited by 27
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1008-y · Cited by 27
Roche, F., Gaspoz, J.-M., Pichot, V., Costes, F., Isaaz, K., Ferron, C., Roche, C., Geyssant, A., Lacour, J.-R., & Barthélémy, J.-C. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00614-0 · Cited by 26
Kaufmann, H. (1997) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70329-5 · Cited by 24
Methods Other Than Tilt Testing for Diagnosing Neurocardiogenic (Neurally Mediated) Syncope
Brignole, M., & Menozzi, C. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb03906.x · Cited by 24
Ruwald, M. H., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.007 · Cited by 23
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 22
Sivathamboo, S., Liu, Z., Sutherland, F., Minato, E., Casillas-Espinosa, P. M., Jones, N. C., Todaro, M., Seneviratne, U. K., Cahill, V., Yerra, R., et al. (2022) · Neurology · doi:10.1212/wnl.0000000000200173 · Cited by 22
Syncope: Review of Monitoring Modalities
Krahn, A. D., Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., & Yee, R. K. (2008) · Current Cardiology Reviews · doi:10.2174/157340308783565447 · Cited by 22
Implantable loop recorders: a viable diagnostic tool in veterinary medicine
James, R., Summerfield, N., Loureiro, J., Swift, S., & Dukes‐McEwan, J. (2008) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2008.00593.x · Cited by 22
Syncope: Current diagnosis and treatment
Henderson, M. C., & Prabhu, S. D. (1997) · Current Problems in Cardiology · doi:10.1016/s0146-2806(97)80008-4 · Cited by 22
Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder
Ergül, Y., Tanıdır, İ. C., Özyılmaz, İ., Akdeniz, C., & Tuzcu, V. (2015) · Pediatrics International · doi:10.1111/ped.12530 · Cited by 21
Cooper, P. N., Westby, M. J., Pitcher, D. W., & Bullock, I. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00368 · Cited by 20
Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Subbiah, R., Chia, P.-L., Gula, L., Klein, G., Skanes, A., Yee, R., & Krahn, A. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x10666140214120056 · Cited by 19
Utility of event loop recorders for the management of arrhythmias in young ambulatory patients
Martinez, T., & Sztajzel, J. M. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.11.004 · Cited by 20
Mason, P. K., Wood, M. A., Reese, D. B., Lobban, J. H., Mitchell, M. A., & Dimarco, J. (2003) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.07.011 · Cited by 20
Selecting Appropriate Diagnostic Tools for Evaluating the Patient With Syncope/Collapse
Krahn, A. D., Andrade, J. G., & Deyell, M. W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.003 · Cited by 19
Kanjwal, K., Kanjwal, Y., Karabin, B. L., & Grubb, B. P. (2009) · International Journal of Medical Sciences · doi:10.7150/ijms.6.106 · Cited by 19
Investigation of syncope: increasing the yield and reducing the cost
Zaidi, A. (2000) · European Heart Journal · doi:10.1053/euhj.1999.2058 · Cited by 17
Is There an Effective Treatment for Neurally Mediated Syncope?
Kapoor, W. N. (2003) · JAMA · doi:10.1001/jama.289.17.2272 · Cited by 20
External Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Costs and utility of tests in the evaluation of the pediatric patients with syncope
Steinberg, L. A., & Knilans, T. K. (2001) · Progress in Pediatric Cardiology · doi:10.1016/s1058-9813(01)00097-2 · Cited by 17
Determining the optimal duration for premature ventricular contraction monitoring
Hsia, B. C., Greige, N., Patel, S. K., Clark, R. M., Ferrick, K. J., Fisher, J. D., GROSS, J. N., Biase, L. D., & KRUMERMAN, A. K. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.07.013 · Cited by 16
Syncope: Etiology and diagnostic approach
Hanna, E. B. (2014) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.81a.13152 · Cited by 14
Shanmugam, N., & Liew, R. (2012) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v41n3p115 · Cited by 14
Investigating syncope: a review
Gould, P. A., Krahn, A. D., Klein, G. J., Yee, R. K., Skanes, A. C., & Gula, L. J. (2005) · Current Opinion in Internal Medicine · doi:10.1097/01.hco.0000198986.16626.86 · Cited by 14
PocketECG: a new continuous and real-time ambulatory arrhythmia diagnostic method.
Dziubinski, M. J. (2011) · PubMed · Cited by 14
Paskaranandavadivel, N., Lin, A. Y., Cheng, L. K., Bissett, I. P., Lowe, A., Arkwright, J. W., Mollaee, S., Dinning, P. G., & O’Grady, G. (2021) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-021-02316-y · Cited by 12
Schuchert, A., Behrens, G., & Meinertz, T. (2002) · Zeitschrift für Kardiologie · doi:10.1007/s392-002-8373-4 · Cited by 12
Auer, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm637 · Cited by 10
Paylos, J. M., & Aguilar, R. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76331-2 · Cited by 9
Falls, Dizziness, and Syncope in the Very Old
Didyk, N., & Morillo, C. A. (2004) · Developments in cardiovascular medicine · doi:10.1007/978-1-4419-8865-2_6 · Cited by 9
Henry Isaiah Dorr Was the First Person to Hold the Title Professor of Anaesthesia
Lowenstein, E., Dorr, H. I., Kitz, R. J., & Dorr, H. I. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00057 · Cited by 9
Diagnostic algorithm for syncope
Mereu, R., Sau, A., & Lim, P. B. (2014) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.05.008 · Cited by 8
Loop recorders for syncope evaluation: what is the evidence?
Cheung, C. C., & Krahn, A. D. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243463 · Cited by 8
Morillo, A., Myerburg, R. J., Sila, C. A., Goldberger, J. J., Heidenreich, P. A., Klein, G. J., Knight, B. P., Cohen, I., Ellenbogen, K. A., Epstein, A. E., et al. (2006) · Cited by 9
Diagnosis and Management of Vasovagal Syncope and Dysautonomia
Sealey, B., & Lui, K. (2004) · AACN Clinical Issues Advanced Practice in Acute & Critical Care · doi:10.1097/00044067-200407000-00012 · Cited by 8
Altinsoy, M., Sutton, R., Kohno, R., Sakaguchi, S., Mears, R. K., & Benditt, D. G. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12560 · Cited by 7
Kakkar, S., Chauhan, S., Bala, R., Bharti, B., Kumar, V., Rohit, M., & Bhalla, V. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05461-9 · Cited by 7
Krahn, A. D., Renner, S., Klein, G. J., Yee, R. K., Skanes, A. C., & Evans, E. M. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00400.x · Cited by 7
Angaran, P., Klein, G. J., Yee, R. K., Skanes, A. C., Gula, L. J., Leong‐Sit, P., & Krahn, A. D. (2011) · Neurologic Clinics · doi:10.1016/j.ncl.2011.07.005 · Cited by 7
Gula, L. J., Klein, G. J., Zurawska, U., Massel, D. R., Yee, R. K., Skanes, A. C., & Krahn, A. D. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02306.x · Cited by 7
Evaluation of syncope: an overview.
Gupta, A. K., Maheshwari, A., & Lokhandwala, Y. Y. (2001) · PubMed Central · Cited by 6
Seidl, K., Breunung, S., Rameken, M., Siemon, G., Schwacke, H., Drögemüller, A., Zahn, R., & Senges, J. C. (2000) · Zeitschrift für Kardiologie · doi:10.1007/s003920050007 · Cited by 6
Højager, A., Tingsgaard, J. K., Andersen, D. M., Søholm, H., Taskiran, M., Bock, T. G., & Schoos, M. M. (2020) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2020.107711 · Cited by 5
The Role of the Syncope Management Unit
Kenny, R. A., Rice, C. P., & Byrne, L. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.016 · Cited by 5
García, J. R., Samartín, R. C., Sánchez, V., & Jj, E. A. (1998) · Revista Española de Cardiología · doi:10.1016/s0300-8932(98)74781-5 · Cited by 5
Holter monitoring in diagnosis of arrhythmias and asequence heart
Целуйко, В. И., & Radchenko, О. (2016) · Medicine of Ukraine · doi:10.37987/1997-9894.2016.5-6(201-2).204729 · Cited by 4
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 4
Gupta, A., & BONADIO, W. A. (2018) · Clinical Pediatrics · doi:10.1177/0009922818809464 · Cited by 4
Tayal, U., & Dancy, M. C. (2013) · Medicine · doi:10.1016/j.mpmed.2012.11.004 · Cited by 4
Seizures and Syncope: What's the Difference?
Zaidi, A. M., & Fitzpatrick, A. P. (2001) · Cardiac Electrophysiology Review · doi:10.1023/a:1013218519485 · Cited by 4
Richtlinien für die Durchführung der nichtinvasiven Diagnostik von Rhythmusstörungen
Block, M. S., Borggrefe, M., Goedel-Meinen, L., Hohnloser, S. H., Jung, W., Kalusche, D., Kück, K., Meinertz, T., Oeff, M., & Pitschner, H. F. (2001) · Steinkopff eBooks · doi:10.1007/978-3-642-57631-7_7 · Cited by 4
Kürer, C. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00660-0 · Cited by 4
Blücher, S., Kaemmerer, H. M., Lammers, A. E., Brodherr-Heberlein, S., & Hess, J. (2000) · Herz · doi:10.1007/pl00001978 · Cited by 4
Current investigations used to assess syncope
Arthur, W., & Kaye, G. (2001) · Postgraduate Medical Journal · doi:10.1136/pmj.77.903.20 · Cited by 4
Adams, M. E., Antczak‐Bouckoms, A., Frazier, H. S., Lau, J., Chalmers, T. C., & Mosteller, F. C. (1993) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462300003068 · Cited by 4
Electrocardiographic monitoring in the assessment of unexplained syncope
Sarasin, F. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00306-1 · Cited by 4
Diagnosis of Arrhythmias with Non-invasive Tools
Sullivan, R. M., Li, W. W., Kendig, A. C., & Olshansky, B. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-161-5_5 · Cited by 4
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 3
Steinbach, K. K., Nümberg, M., & Wessely, E. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00292.x · Cited by 3
Hamman's syndrome: an atypical cause of chest pain
Barge‐Caballero, E., Bouzas‐Mosquera, A., Gulias-Soidan, D., & Castro‐Beiras, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm410 · Cited by 3
The Role of the Syncope Management Unit
Kenny, R. A., Rice, C. P., & Byrne, L. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.013 · Cited by 3
Appropriateness of ECG Holter requests in an outpatient service: a prospective study
Piccirilli, S., Gallagher, M. M., Vellini, M., Padula, M., Voumvourakis, A., Santini, L., Magliano, G., & Romeo, F. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000278449.96988.82 · Cited by 3
Electrocardiology, N., Kadish, A. H., Buxton, A. E., Winters, W. L., & Boone, A. W. (2001) · Cited by 3
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 3
Syncope and Arrhythmias: Role of the Electrophysiological Study
Stouffer, G. A., Sheahan, R. G., Lenihan, D. J., & Sheahan, R. G. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200107000-00007 · Cited by 3
de Jongh, T. O. H., & van Dijk, J. (2003) · Huisarts en Wetenschap · doi:10.1007/bf03083397 · Cited by 3
Monitoring of Atrial Tachyarrhythmias
Mehra, R. (2002) · Cardiac Electrophysiology Review · doi:10.1023/a:1016372823942 · Cited by 3
Contribuição do monitor de eventos no diagnóstico de sintomas
Grupi, C., Barbosa, S. A., Sampaio, C. R., & Moffa, P. J. (1998) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x1998000500001 · Cited by 3
Significance of external loop recorders (ELR) in diagnosis of disturbances in heart rhythm
Młynarczyk, J., Poręba, M., Gać, P., Derkacz, A., Bryłka, A., Jurdziak, M., Pilecki, W., Mazur, G. J., Sobieszczańska, M. I., & Poręba, R. (2015) · Family Medicine & Primary Care Review · doi:10.5114/fmpcr/45093 · Cited by 2
Diagnosis and Management of Syncope
Karabin, B. L., & Grubb, B. P. (2011) · Wiley eBooks · doi:10.1002/9781118788967.ch16 · Cited by 2
Syncope/Presyncope in the Competitive Athlete
Asplund, C. A., O’Connor, F. G., & Levine, B. D. (2010) · Springer eBooks · doi:10.1007/978-0-387-92775-6_9 · Cited by 2
Características clínicas de pacientes llevados a monitoría externa de eventos
Carvajal, J. J., Clavijo, C., Bautista, L. J., & Mora, G. (2014) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2013.11.001 · Cited by 2
Kanjwal, M. Y., & Grubb, B. P. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0085-4 · Cited by 2
Hussein, A. A., & SALIARIS, A. P. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.07.014 · Cited by 2
Syncope: Approach to diagnosis
Anil, O. (2016) · Journal of Clinical and Preventive Cardiology · doi:10.4103/2250-3528.191099 · Cited by 2
Iliev, I. T., Jekova, I. I., Tabakov, S. D., Koshtikova, K. G., Runev, N. M., & Manov, Е. (2022) · Lecture notes in networks and systems · doi:10.1007/978-3-030-96638-6_33 · Cited by 2
Synkopendiagnostik: wann ambulant, wann stationär?
Schuchert, A., & Wille, E. (2008) · Herz · doi:10.1007/s00059-008-3145-x · Cited by 2
In Vitro Model for Cardiac Function under Xenon Anesthesia
Schroth, S., Reyle‐Hahn, M., & Rossaint, R. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00054 · Cited by 2
In Vitro Model for Cardiac Function under Xenon Anesthesia
Stowe, D. F., Bosnjak, Z. J., Rehmert, G. C., Kwok, W., Weigt, H. U., & Georgieff, M. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00055 · Cited by 2
Pulmonary Aspiration of a Milk–Cream Mixture
Cox, R. G. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00049 · Cited by 2
Mitjans, À. M. (2000) · Springer eBooks · doi:10.1007/978-88-470-2139-6_59 · Cited by 2
Kardiale Synkope: Diagnostik und Therapie
Seegers, J., & Zabel, M. (2011) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-011-0131-4 · Cited by 1
Podsumowanie wskazań do implantacji układów stymulujących serce
Załuska, R., Bobruk, M., Bobruk, M., Grabowski, M., & Bobruk, M. (2019) · Choroby Serca i Naczyń · doi:10.5603/chsin.2019.0041 · Cited by 1
Neto, A. C. L., Mezzalira, R., & Bittar, R. S. M. (2026) · Brazilian Journal of Otorhinolaryngology · doi:10.1016/j.bjorl.2026.101822 · Cited by 1
The Effect of Late Adoption of Canadian Innovations: A Case for Implantable Cardiac Monitors
Sadri, H., & Winsor, P. (2014) · Healthcare Management Forum · doi:10.1016/j.hcmf.2014.01.002 · Cited by 1
Update on syncope in the older person – a clinical review
Mappilakkandy, R. K., & Edwards, I. (2012) · Reviews in Clinical Gerontology · doi:10.1017/s0959259812000202 · Cited by 1
2018 KHRS Guidelines for Catheter Ablation of Ventricular Arrhythmias – Part1
Roh, S., Kim, S., Kim, Y.-N., Kim, J.-Y., Kim, J., Kim, T., Nam, G., Park, K., Park, H., Pak, H., et al. (2018) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2018.006 · Cited by 1
Kardiyak Olay Kaydedici ve Telemetri Sistemi için Yeni Bir Bileklik Tasarımı
BİLGİN, G., Oktay, M., & Bilgin, S. (2021) · Mehmet Akif Ersoy Üniversitesi Fen Bilimleri Enstitüsü Dergisi · doi:10.29048/makufebed.889637 · Cited by 1
Yang, S., & ZIMETBAUM, P. J. (2020) · Springer eBooks · doi:10.1007/978-3-030-47868-1_26 · Cited by 1
Zeevi, B. (2002) · KARGER eBooks · doi:10.1159/000067384 · Cited by 1
Effiziente Synkopenabklärung: Wann soll der implantierbare Loop-Rekorder verwendet werden?
Pezawas, T., & Schmidinger, H. (2004) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 1
Zimerman, L. I., Medeiros, C. M., & Ribeiro, J. P. (1998) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x1998000300010 · Cited by 1
Synkope und epileptischer Anfall
Becker, A., Noachtar, S., Reithmann, C., Brandt, T. H., & Steinbeck, G. (2005) · Der Internist · doi:10.1007/s00108-005-1475-9 · Cited by 1
Linzer, M., & Estes, N. A. M. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80235-6 · Cited by 1
Self-citationElektrophysiologische Diagnostik und Therapie
Ritscher, G., Simon, H., Nölker, G., Brachmann, J., & Sinha, A. M. (2010) · Medizinische Klinik - Intensivmedizin und Notfallmedizin · doi:10.1007/s00063-010-1078-7 · Cited by 1
Anesthetic Implications of a New Implantable Device: The Loop Recorder System
Hepner, D. L. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00058 · Cited by 1
Metadata
- Authors
- Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W.
- Affiliations
- Duke Medical Center (US)
- Duke University (US)
- Corresponding author
- Linzer, Mark
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1990-07
- Volume
- 66
- Issue
- 2
- Pages
- 214-219
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2066071317
- Semantic Scholar
- 7b7fdf3a51f4893b64f1f600a91f1c4149d231a8
- Cited by
- 239
- References
- 23
- Citations by year
- 2026: 2 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 6 · 2019: 2 · 2018: 10 · 2017: 15 · 2016: 3 · 2015: 5 · 2014: 9 · 2013: 10 · 2012: 5
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (1r01hl040392-01a1, 2s07rr005405-30)
- National Heart, Lung, and Blood Institute (HL24920, HL40392)
- National Center for Research Resources (S07-RR-05405)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- unexplained syncope, Holter monitoring, diagnostic yield, cardiac arrhythmias, neurally mediated syncope, ventricular tachycardia, atrioventricular block, supraventricular tachycardia, asystole, sudden cardiac death
- MeSH terms
- Arrhythmias, Cardiac, Female, Follow-Up Studies, Humans, Male, Middle Aged, Patient Compliance, Prospective Studies, Syncope, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.