A new method of inhibiting glycolysis in blood samples
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The maintenance of hydrogen ion concentration in blood samples at pH 5.3-5.9 immediately inhibits glycolysis. This effect is due to the inhibition of all glycolytic enzymes, as shown by measurement of various glycolytic intermediates. At the inhibitory pH at 25 degrees C, the glucose content did not decrease over a period of 8 h, but it did decrease by 1.3 +/- 1.1 mg/dl over 24 h.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(1975) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/58.5.1085 · Cited by 19,795
Beutler, E., Blume, K. G., Kaplan, J. C., Löhr, G. W., Ramot, B., & Valentine, W. N. (1977) · British Journal of Haematology · doi:10.1111/j.1365-2141.1977.tb00589.x · Cited by 533
Increased Cell Membrane Permeability in the Pathogenesis of Hereditary Spherocytosis *
Jacob, H. S., Jandl, J. H., Bell, S. C., & Files, N. M. (1964) · Journal of Clinical Investigation · doi:10.1172/jci105046 · Cited by 168
Energy Metabolism in Human Erythrocytes
Feig, S. A., Shohet, S. B., & Nathan, D. G. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106662 · Cited by 67
Jacob, H. S. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105695 · Cited by 50
Glucose determinations in plasma and serum: potential error related to increased hematocrit.
Sidebottom, R. A., Williams, P. R., & Kanarek, K. S. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.1.190 · Cited by 48
Evaluation of Glucose Determinations in Untreated Serum Samples
Weissman, M., & Klein, B. (1958) · Clinical Chemistry · doi:10.1093/clinchem/4.5.420 · Cited by 47
Guminska, M., & Sterkowicz, J. (1976) · PubMed · Cited by 30
Glycolysis: A re-evaluation of the effect on blood glucose
Overfield, C. V., Savory, J., & Heintges, M. G. (1972) · Clinica Chimica Acta · doi:10.1016/0009-8981(72)90296-3 · Cited by 23
ラット赤血球の解糖系に及ぼす2,3‐Dimethoxy‐5‐methyl‐6‐(10`1´‐hydroxydecyl)‐1,4‐benzoquinone(CV‐2619)の影響
Shimamoto, N., Noriko, G. O. T. O., & Hirata, M. (1982) · Folia Pharmacologica Japonica · doi:10.1254/fpj.80.137 · Cited by 3
Research works printed but not linked: 1
- Ichikawa, 1981, Changes with age of ATP contents in rat blood measured by the bioluminescent technique, Ann Rep Tokyo Metr Res Lab PH, 32, 107
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Narayanan, S. (2000) · American Journal of Clinical Pathology · doi:10.1309/c0nm-q7r0-ll2e-b3uy · Cited by 198
Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.121707 · Cited by 160
Bogdanet, D., O’Shea, P., Lyons, C., Shafat, A., & Dunne, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113451 · Cited by 117
What is Blood Glucose: Can it be Measured?
Burrin, J. M., & Alberti, K. G. M. M. (1990) · Diabetic Medicine · doi:10.1111/j.1464-5491.1990.tb01370.x · Cited by 105
Guder, W. (2003) · Cited by 93
Sodium fluoride: an ineffective inhibitor of glycolysis
Gambino, R. (2013) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2012.012135 · Cited by 50
What is the most suitable blood collection tube for glucose estimation?
Dimeski, G., Yow, K. S., & Brown, N. N. (2015) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563214544708 · Cited by 47
Glucose measurement in body fluids: A ready reckoner for clinicians
Kubihal, S., Goyal, A., Gupta, Y., & Khadgawat, R. (2020) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2020.11.021 · Cited by 47
Skogberg, N., Laatikainen, T. K., Koskinen, S. V. P., Vartiainen, E. A., Jula, A., Leiviskä, J., Härkänen, T., & Koponen, P. (2016) · European Journal of Public Health · doi:10.1093/eurpub/ckw041 · Cited by 45
Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
“[14] proved the ability of sample acidification by addition of citrate buffer to block the activity of hexokinase and phosphofructokinase”
BackgroundWhich sample tube should be used for routine glucose determination?
Bonetti, G., Cancelli, V., Coccoli, G., Piccinelli, G., Brugnoni, D., Caimi, L., & Carta, M. (2015) · Primary care diabetes · doi:10.1016/j.pcd.2015.11.003 · Cited by 40
Review of Health Examination Surveys in Europe.
Tolonen, H. K., Koponen, P., Aromaa, A. J., Conti, S., Graff‐Iversen, S., Grøtvedt, L., Kanieff, M., Mindell, J. S., Natunen, S., Primatesta, P., et al. (2008) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 39
It’s Time for a Better Blood Collection Tube to Improve the Reliability of Glucose Results
Peake, M. J., Bruns, D. E., Sacks, D. B., & Horvath, A. R. (2013) · Diabetes Care · doi:10.2337/dc12-1312 · Cited by 36
Citric/citrate buffer: an effective antiglycolytic agent
del Pino, I. G., Constanso, I., Mourín, L. V., Safont, C. B., & Vázquez, P. R. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0735 · Cited by 33
Klaus, R., Fischer, W., & Hauck, H. E. (1991) · Chromatographia · doi:10.1007/bf02321427 · Cited by 30
Lima-Oliveira, G., Brennan-Bourdon, L. M., Varela, B., Arredondo, M. E., Aranda, E., Flores, S., & Zamora, S. P. O. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1849008 · Cited by 30
Jamieson, E. L., Dimeski, G., Flatman, R., Hickman, P. E., Jones, G. R. D., Marley, J. V., McIntyre, D. H., McNeil, A. R., Nolan, C. J., Potter, J. M., et al. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.10.002 · Cited by 28
Technical and clinical validation of the Greiner FC-Mix glycaemia tube
van der Hagen, E. A. E., Fokkert, M. J., Kleefman, A. M. D., Thelen, M., van den Berg, S. A. A., & Slingerland, R. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0944 · Cited by 27
Carey, R., Lunt, H., Heenan, H. F., Frampton, C. M. A., & Florkowski, C. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.017 · Cited by 26
Juričić, G., Bakliža, A., Saračević, A., Kopčinović, L. M., Dobrijević, S., Drmić, S., & Šimundić, A.-M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0746 · Cited by 26
Juricic, G., Kopcinovic, L. M., Saracevic, A., Bakliza, A., & Simundic, A.-M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0358 · Cited by 23
Ridefelt, P., Åkerfeldt, T., & Helmersson-Karlqvist, J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.02.022 · Cited by 21
Inhibition of Glycolysis for Glucose Estimation in Plasma: Recent Guidelines and their Implications
Gupta, S. D., & Kaur, H. (2013) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-013-0405-1 · Cited by 17
Landberg, E., Nevander, S., Hadi, M. A., Blomberg, M. I., Norling, A., Ekman, B., & Lilliecreutz, C. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1980224 · Cited by 16
Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes
Winter, T., Hannemann, A., Suchsland, J., Nauck, M. A., & Petersmann, A. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0860 · Cited by 14
Are fluoride-containing blood tubes still needed for glucose testing?
Bruns, D. E. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.01.009 · Cited by 14
Mansell, E. C., Lunt, H., & Docherty, P. D. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.01.012 · Cited by 11
Gupta, S., Gupta, A., Verma, M., Singh, K., Kaur, A., Chopra, B., & Kaur, V. (2016) · International Journal of Applied and Basic Medical Research · doi:10.4103/2229-516x.174010 · Cited by 10
Skogberg, N., Laatikainen, T. K., Lilja, E., Lundqvist, A., Härkänen, T., & Koponen, P. (2019) · BMC Public Health · doi:10.1186/s12889-019-6698-0 · Cited by 10
Effects of different tube types on patient classification using current diabetes decision limits
Orth, M., Hawran, H., Ulloor, J., Bachhawat, K., & Lennartz, L. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00134 · Cited by 9
Preanalytical issues related to routine and diagnostic glucose tests: Results from a survey in Spain
del Pino, I. G., Ibarz, M., Rioja, R. G., Salas, P., Segovia, M., Puente, J. J., Marzana, I., Ventura, M., Martínez, D., Llopis, M. A., et al. (2020) · Biochemia Medica · doi:10.11613/bm.2020.010704 · Cited by 8
Optimal collection tubes for plasma glucose determination: confusion reigns supreme
Pasqualetti, S., Szőke, D., Birindelli, S., Dolci, A., & Panteghini, M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0137 · Cited by 8
Stolz, M., Schlawne, C., Hoffmann, J., Hartmann, V., Marini, I., Fritsche, A., Peter, A., Bakchoul, T., & Schick, F. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4358 · Cited by 7
The microcalorimetric approach to human sperm physiology
Antonelli, M. L., Luciani, M., & Silvestroni, L. (1991) · Thermochimica Acta · doi:10.1016/0040-6031(91)80379-w · Cited by 7
Methaemoglobin does not interfere with the analysis of glucose in Terumo Venosafe Glycaemia™tubes
Jones, I., & Böttiger, A. K. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.744463 · Cited by 4
Universal Anticoagulantsfor Medical Laboratory use
Tatsumi, N. (2002) · Japanese Journal of Thrombosis and Hemostasis · doi:10.2491/jjsth.13.158 · Cited by 4
Problems with the use of whole blood as a sample material in novel direct glucose analysers
Savolainen, K., Viitala, A. J., Puhakainen, E. V., & Väisänen, M. (1990) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519009089158 · Cited by 4
Pre-analytical Errors in Glucose Estimation Results in Query on Diabetic Management
Loganathan, P., Gasper, S. K., Afel, F. K., & Selvakumar, K. (2018) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-018-0782-6 · Cited by 3
Glucose(monitoring): from bench to real world experiences
Fokkert, M. J. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.207217778 · Cited by 2
Wiriyaprasit, R., Moonla, K., Apiratmateekul, N., Chittamma, A., Kost, G. J., & Treebuphachatsakul, W. (2024) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2024.e00388 · Cited by 2
Reshma, D. C. (2019) · International Journal of Clinical Biochemistry and Research · doi:10.18231/j.ijcbr.2019.066 · Cited by 2
Kume, Y., Hirowatari, Y., Kurano, M., Yatomi, Y., & Matsushita, M. (2023) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632231194829 · Cited by 2
Daimane, D., & Basu, S. (2024) · Cureus · doi:10.7759/cureus.72641 · Cited by 1
Effect of Addition of Sodium Citrate in Plasma Extraction for Venous Blood Glucose Determination
Tizziani, T., Siebert, D. A., Pancotte, T., & de Córdova, C. M. M. (2014) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2014.511085 · Cited by 1
Guder, W. G., Narayanan, S., Wisser, H., & Zawta, B. (2003) · Wiley eBooks · doi:10.1002/9783527612505.refs
Apparent gluco-concentration with citrate tubes is not a result of water uptake by erythrocytes
Potter, J. M., Pratt, J., D'Souza, M., Naumovski, J., Yosar, J., Hickman, P. E., & Salib, M. M. (2025) · Pathology · doi:10.1016/j.pathol.2025.09.010
Onyeaghala, A. A., Nurudeen, A. B., Adigun, A., & Babalola, C. P. (2024) · Qeios · doi:10.32388/ubmfgd
Könnun á stöðugleika glúkósa í þremur tegundum blóðsýnaglasa
Jónsdóttir, Þ. G., Hjaltadóttir, G., & Þorsteinsdóttir, I. (2012) · Hirsla (Landspítali University Hospital)
Effect of blood acidification on hemolysis-induced insulin degradation
Ercan, Ş. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120773
Grzych, G., Pinsart, A., Defauwes, I., Campas, M., Grifnée, E., Tullio, P. D., & Cavalier, E. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1384
Abara, U. S., Ibanga, I. E., Nwapi, L. L., Ekpo, M. I., Akpan, H. A., Nkechi, O., Mkpani, J. O., Joseph, N. I., Konglam, N. I., Nkwocha, B. C., et al. (2023) · Journal of Advances in Medical and Pharmaceutical Sciences · doi:10.9734/jamps/2023/v25i1595
Inosine attenuates glycolysis in erythrocytes via glucose transporter inhibition
Kume, Y., Ohkubo, M., Nakatsuka, N., Aritake‐Okada, S., Yoshikawa, N., Yoshida, T., Isago, H., & Kurano, M. (2026) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632261433354
Müller, R., Müller, D., & Plonné, D. (2026) · PLoS ONE · doi:10.1371/journal.pone.0344562
Nounou, O. S., Mamy, N., Dahlia, P., Beya, D. T., Michael, B., & Patrick, M. (2026) · PubMed Central
Mansell, E. C. (2017) · UC Research Repository (University of Canterbury) · doi:10.26021/2943
Wiedmer, G. P. (2016) · Repositório Digital Institucional da UFPR (Universidade Federal do Paraná)
Könnun á stöðugleika glúkósa í þremur mismunandi \nblóðsýnaglösum
Jónsdóttir, Þ. G. (2010) · Skemman
Metadata
- Authors
- Uchida, K., Matuse, R., Toyoda, E., Okuda, S., & Tomita, S.
- Corresponding author
- Uchida, Kazuo
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 1988-02
- Volume
- 172
- Issue
- 1
- Pages
- 101-108
- ISSN
- 0009-8981 (ISSN-L)
- OpenAlex
- W2932060406
- Semantic Scholar
- 6588f3b143d17614865631c3edebdfbf3528ac43
- Cited by
- 53
- References
- 11
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 2 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 3 · 2012: 4
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Clinica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Biochemical and Molecular Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer, Hypoxia, and Metabolism
- Keywords
- glycolysis inhibition, blood samples, low pH, pH, glycolytic enzymes, glycolytic intermediates, glucose degradation, sample storage
- MeSH terms
- Adenosine Triphosphate, Blood Glucose, Blood Specimen Collection, Electrolytes, Erythrocytes, Glycolysis, Hexokinase, Humans, Hydrogen-Ion Concentration, Phosphofructokinase-1
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.