Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Glucose measurements are crucial in diabetes diagnosis. We aimed to assess the effectiveness of liquid citrate acidification in preventing glycolysis and investigate glucose stability in serum, sodium fluoride (NaF/KOx) and Glucomedics tubes. Samples from 40 participants were collected in serum, lithium-heparin (LiH), sodium fluoride/potassium oxalate (NaF/KOx) and Glucomedics tubes. Glucose was measured within 60 min (baseline), 120 and 180 min from venipuncture. Serum, NaF/KOx and Glucomedics values at baseline were compared to LiH glucose concentration. Additionally, glucose values measured at 120 and 180 min from each tube were compared with the baseline value. Mean absolute bias for each tube and time point was calculated and compared to recommended criteria. The regression equation obtained comparing citrate to NaF/KOx tubes was used to recalculate glucose results retrieved from the laboratory information system. Glucose measured in Glucomedics was higher (9.9%; p<0.001), while glucose in NaF/KOx and serum was lower compared to LiH (2.4%; p<0.001 and 3.2%; p<0.001, respectively). Biases for all tubes were clinically significant. Glucose remained unchanged at room temperature in all tubes for up to 180 min after venipuncture. Observed bias caused by Glucomedics leads to a 10.6% increase in diabetes prevalence (p<0.001). Inhibition of glycolysis is most effectively achieved using liquid citrate acidification, compared to LiH, NaF/KOx or serum. Due to clinically significant bias relative to reference glucose, the interchangeable use of different tube types for serial glucose measurements is not recommended. The replacement of NaF/KOx with Glucomedics tubes substantially impacts glucose results, giving marked rise in diabetes prevalence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Effectiveness of sodium fluoride as a preservative of glucose in blood
Chan, A. Y., Swaminathan, R., & Cockram, C. S. (1989) · Clinical Chemistry · doi:10.1093/clinchem/35.2.315 · Cited by 289
Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.121707 · Cited by 160 · cited 2×
“The authors concluded that acidification was superior to NaF/KOx alone in inhibiting glycolysis [9].”
BackgroundStabilization of glucose in blood samples: why it matters
Bruns, D. E., & Knowler, W. C. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.126037 · Cited by 125 · cited 2×
“Therefore, reporting of accurate glucose results is important for correct patient classification according to the established guidelines [2, 3].”
BackgroundNikolac, N., Šupak Smolčić, V., Šimundić, A.-M., & Ćelap, I. (2013) · Biochemia Medica · doi:10.11613/bm.2013.031 · Cited by 99
Self-citationA new method of inhibiting glycolysis in blood samples
Uchida, K., Matuse, R., Toyoda, E., Okuda, S., & Tomita, S. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90125-8 · Cited by 53
It takes acid, rather than ice, to freeze glucose
van den Berg, S. A. A., Thelen, M. H. M., Salden, L. P. W., van Thiel, S. W., & Boonen, K. J. M. (2015) · Scientific Reports · doi:10.1038/srep08875 · Cited by 49
Stability of glucose in plasma with different anticoagulants
Fobker, M. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1049 · Cited by 47
Ridefelt, P., Åkerfeldt, T., & Helmersson-Karlqvist, J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.02.022 · Cited by 21 · cited 2×
“Our results are in accordance with previously published data [27, 28].”
BackgroundResult
Cited by
Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
“The use of citrate in liquid form (Vacuette® Glucomedics, Greiner Bio-One) also implied the obtainment of PG results significantly higher in comparison to those obtained using fluoride only [25-28].”
BackgroundResultBlood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
Carey, R., Lunt, H., Heenan, H. F., Frampton, C. M. A., & Florkowski, C. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.017 · Cited by 26
Nikolac, N., Lenicek Krleza, J., & Simundic, A.-M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.017 · Cited by 18
Metadata
- Authors
- Juricic, G., Kopcinovic, L. M., Saracevic, A., Bakliza, A., & Simundic, A.-M.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-01-01
- Volume
- 54
- Issue
- 2
- Pages
- 363-71
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W786788947
- Cited by
- 23
- References
- 9
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes. https://app.cochat.ai/papers/10.1515/cclm-2015-0358
- The paper
- Juricic, G., Kopcinovic, L. M., Saracevic, A., Bakliza, A., & Simundic, A.-M. (2016). Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2015-0358
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.