Frost growth parameters in a forced air stream
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Real-time frost mass measurement methods have been previously applied in [22] and [23].
“Real-time frost mass measurement methods have been pre viously applied, for instance, in [22] and [23].”
In [22], the weighing plate was connected via a shaft and was not directly in contact with the cold surface where the frost formed.
“However, in [22], the weighing plate was connected via a shaft and was not directly in contact with the cold surface where the frost formed.”
During frost formation, frost thickness, frost surface temperature, frost density, and frost thermal conductivity all increase continuously.
“These studies suggest that during frost formation, frost thickness, frost surface temperature, frost density, and frost thermal conductivity all increase continuously.”
From Frost growth and densification in laminar flow over flat surfaces (2011) · cites this paper as Östin and Anderson [5]
Frost growth depends strongly on the cold plate temperature and the air humidity.
“Experiments by Östin and Anderson [5] and others suggest that the frost growth depends strongly on the cold plate temperature and the air humidity.”
From Frost growth and densification in laminar flow over flat surfaces (2011) · cites this paper as Östin and Anderson [5]
Frost thermal conductivity varies with its density.
“According to their correlations [9,10,11] frost thermal conductivity varies with its density.”
From Frost formation on fin-and-tube heat exchangers. Part I—Modeling of frost formation on fin-and-tube heat exchangers (2004) · cites this paper as [10]
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 19,877 · see citing works
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,524 · see citing works
Frost formation with varying environmental parameters
Jones, B. W., & Parker, J. D. (1975) · Journal of Heat Transfer · doi:10.1115/1.3450350 · Cited by 171 · see citing works
Equation of the growth rate of frost forming on cooled surfaces
Schneider, H. W. (1978) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(78)90098-4 · Cited by 148 · see citing works
Effective Thermal Conductivity of Frost
Auracher, H. (1986) · Proceeding of International Symposium on Heat and Mass Transfer in Refrigeration and Cryogenics · doi:10.1615/ichmt.1986.intsymphmtinrefcryo.210 · Cited by 68 · see citing works
Generalized correlation of the water frost thermal conductivity
Dietenberger, M. A. (1983) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(83)90011-x · Cited by 52 · see citing works
Transient hot-strip probe for measuring thermal properties of insulating solids and liquids
Gustafsson, S. E., & Karawacki, E. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137466 · Cited by 51 · see citing works
Techniques for determining thermal conductivity and heat capacity under hydrostatic pressure
Andersson, S., & Bäckström, G. (1986) · Review of Scientific Instruments · doi:10.1063/1.1138542 · Cited by 44 · see citing works
Self-citationIncipient Phenomena of Frost Formation
Seki, N., FUKUSAKO, S., MATSUO, K., & UEMURA, S. (1984) · Bulletin of JSME · doi:10.1299/jsme1958.27.2476 · Cited by 33 · see citing works
An analysis of incipient frost formation
Seki, N., Fukusako, S., Matsuo, K., & Uemura, S. (1985) · Wärme- und Stoffübertragung · doi:10.1007/bf01682542 · Cited by 28 · see citing works
Aoki, K., KATAYAMA, K., & Hayashi, Y. (1983) · Bulletin of JSME · doi:10.1299/jsme1958.26.87 · Cited by 17 · see citing works
dc-ac hot-wire procedure for determining thermophysical properties under pressure
Nilsson, O. R., Sandberg, O., & Bäckström, G. (1986) · Review of Scientific Instruments · doi:10.1063/1.1138701 · Cited by 10 · see citing works
Aoki, K., Hattori, M., & Takeshi, I. T. O. H. (1986) · Bulletin of JSME · doi:10.1299/jsme1958.29.1499 · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147 · see citing works
Frost growth and densification in laminar flow over flat surfaces
Kandula, M. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.056 · Cited by 141 · see citing works
Dimensionless correlations of frost properties on a cold plate
Yang, D.-K., & Lee, K.-S. (2004) · International Journal of Refrigeration · doi:10.1016/s0140-7007(03)00118-x · Cited by 134 · see citing works
Frost formation on a vertical plate in simultaneously developing flow
Lee, Y. B., & Ro, S. T. (2002) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(02)00216-9 · Cited by 97 · see citing works
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94 · see citing works
Sommers, A. D., Truster, N. L., Napora, A. C., Riechman, A. C., & Caraballo, E. J. (2016) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2016.01.008 · Cited by 84 · see citing works
Fin spacing optimization of a fin-tube heat exchanger under frosting conditions
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.01.016 · Cited by 81 · see citing works
The behavior of frost layer growth under conditions favorable for desublimation
Lee, J., & Lee, K.-S. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.12.039 · Cited by 68 · see citing works
Observations of early-stage frost formation on a cold plate in atmospheric air flow
Cheng, C.-H., & Wu, K.-H. (2003) · Journal of Heat Transfer · doi:10.1115/1.1513576 · Cited by 66 · see citing works
Moallem, E., Padhmanabhan, S., Cremaschi, L., & Fisher, D. E. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.08.010 · Cited by 61 · see citing works
Modeling of frost formation over parallel cold plates
Ismail, K. A. R., & Salinas, C. S. (1999) · International Journal of Refrigeration · doi:10.1016/s0140-7007(98)00069-3 · Cited by 61 · see citing works
Frost growth around a cylinder in a wet air stream
Ismail, K. A. R., Salinas, C., & Gonçalves, M. M. (1997) · International Journal of Refrigeration · doi:10.1016/s0140-7007(96)00065-5 · Cited by 42 · see citing works
EFFECTIVE THERMAL CONDUCTIVITY OF FROST CONSIDERINGMASS DIFFUSION AND EDDY CONVECTION
Kandula, M. (2010) · Special Topics & Reviews in Porous Media - An International Journal · doi:10.1615/specialtopicsrevporousmedia.v1.i4.40 · Cited by 10 · see citing works
Juhola, V., Mikkola, V., Inkeri, E., Kabelac, S., & Tynjälä, T. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.127396 · Cited by 9 · see citing works
Studies of an air cooler under frost condition
Cheng, Y. C. (2019) · doi:10.32657/10356/6557
- Authors
- Östin, R., & Andersson, S.
- Affiliations
- Umeå University (SE)
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 1991-04
- Volume
- 34
- Issue
- 4-5
- Pages
- 1009-1017
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W1996611818
- Cited by
- 116
- References
- 13
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 3 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 5 · 2019: 3 · 2018: 5 · 2017: 7 · 2016: 7 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 5
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- frost growth, frost thickness, frost density, relative humidity, air velocity, surface temperature, water vapour condensation, frost melting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review