The frequency content of gait
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and reduction of noise in kinematics of locomotion
Winter, D. A., Sidwall, H. G., & Hobson, D. A. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90056-6 · Cited by 405
Stearns, S. D., & Ahmed, N. (1976) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1976.4309433 · Cited by 362
Peak dynamic force in human gait
Simon, S. R., Paul, I. L., Mansour, J., Munro, M., Abernethy, P. J., & Radin, E. L. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90009-9 · Cited by 270
The interplay of muscular and external forces in human ambulation
Cappozzo, A., Figura, F., Marchetti, M., & Pedotti, A. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90137-8 · Cited by 241
A general computing method for the analysis of human locomotion
Cappozzo, A., Leo, T., & Pedotti, A. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90083-4 · Cited by 209
Fourier analysis of forces exerted in walking and running
Alexander, R. M., & Jayes, A. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90019-6 · Cited by 151
HATZE, H. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90076-2 · Cited by 123
Kinematics of normal locomotion—A statistical study based on T.V. data
Winter, D. A., Quanbury, A. O., Hobson, D., Sidwall, H. G., Reimer, G. D., Trenholm, B. G., Steinke, T., & Shlosser, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90082-7 · Cited by 113
Soudan, K., Audekercke, R. V., & Martens, M. A. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90006-x · Cited by 106
On precision limits for derivatives numerically calculated from noisy data
Lanshammar, H. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90082-3 · Cited by 81
Cited by
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Using mobile phones to determine transportation modes
Reddy, S., Mun, M., Burke, J., Estrin, D., Hansen, M., & Srivastava, M. (2010) · ACM Transactions on Sensor Networks · doi:10.1145/1689239.1689243 · Cited by 852
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
Self-citationFrequency and velocity of rotational head perturbations during locomotion
Grossman, G. E., Leigh, R. J., Abel, L. A., Lanska, D. J., & Thurston, S. E. (1988) · Experimental Brain Research · doi:10.1007/bf00247595 · Cited by 576
External loading of the knee joint during running and cutting maneuvers
BESIER, T. F., LLOYD, D. G., COCHRANE, J. L., & ACKLAND, T. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00014 · Cited by 498
A Survey of Online Activity Recognition Using Mobile Phones
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2015) · Sensors · doi:10.3390/s150102059 · Cited by 489
“Moreover, in [65], the authors showed that human activity frequencies lie between 0 and 20 Hz and that 98% of the FFT (fast fourier transform) amplitude is contained below 10 Hz.”
BackgroundElectromagnetic effects—From cell biology to medicine
Funk, R. H. W., Monsees, T., & Özkucur, N. (2009) · Progress in Histochemistry and Cytochemistry · doi:10.1016/j.proghi.2008.07.001 · Cited by 423
Mizner, R. L., & Snyder‐Mackler, L. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2005.01.021 · Cited by 375
The Head-Neck Sensory Motor System
(1992) · doi:10.1093/acprof:oso/9780195068207.001.0001 · Cited by 331
Daily physical activity assessment with accelerometers: new insights and validation studies
Plasqui, G., Bonomi, A. G., & Westerterp, K. R. (2013) · Obesity Reviews · doi:10.1111/obr.12021 · Cited by 315
Whole body inverse dynamics over a complete gait cycle based only on measured kinematics
Ren, L., Jones, R. K., & Howard, D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.001 · Cited by 283
Utility of the Frontal Plane Projection Angle in Females With Patellofemoral Pain
Willson, J. D., & Davis, I. S. (2008) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2008.2706 · Cited by 251
Cuticular pad–inspired selective frequency damper for nearly dynamic noise–free bioelectronics
Park, B., Shin, J. H., Ok, J., Park, S., Jung, W., Jeong, C., Choy, S., Jo, Y. J., & Kim, T.-I. (2022) · Science · doi:10.1126/science.abj9912 · Cited by 244
Force treadmill for measuring vertical and horizontal ground reaction forces
Kram, R., Griffin, T. M., Donelan, J. M., & Chang, Y. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.764 · Cited by 239
“These values were similar to those reported previously (1).”
Measurement of physical activity in clinical practice using accelerometers
Arvidsson, D., Fridolfsson, J., & Börjesson, M. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12908 · Cited by 239
Bioreactor Systems for Bone Tissue Engineering
Rauh, J., Milan, F., Günther, K.-P., & Stiehler, M. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0612 · Cited by 225
“Frequencies in the ranges of 5–30 Hz and < 10 Hz were observed during postural muscle activity and walking, respectively.(141) Interestingly, bone cells exhibit a strong frequency selectivity with EMF effectiveness peaking at 15 Hz.”
Khusainov, R., Azzi, D., Achumba, I., & Bersch, S. (2013) · Sensors · doi:10.3390/s131012852 · Cited by 207
Derrick, T. R., van den Bogert, A. J., Cereatti, A., Dumas, R., Fantozzi, S., & Leardini, A. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109533 · Cited by 187
Ankle and foot power in gait analysis: Implications for science, technology and clinical assessment
Zelik, K. E., & Honert, E. C. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.017 · Cited by 183
The effect of low-frequency electrical fields on osteogenesis.
McLeod, K. J., & Rubin, C. T. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00014 · Cited by 177
Fall detection and fall risk assessment in older person using wearable sensors: A systematic review
Bet, P., Castro, P. C., & Ponti, M. A. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.08.006 · Cited by 172
Funk, R. H. W., & Monsees, T. K. (2006) · Cells Tissues Organs · doi:10.1159/000093061 · Cited by 170
Gait analysis in neurological populations: Progression in the use of wearables
Celik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 167
“Antonsson and Mann reported that during barefoot walking, 99% of the acceleration signal is contained frequency below 15Hz [93].”
BackgroundRoss, C. L., Siriwardane, M., Almeida-Porada, G., Porada, C. D., Brink, P., Christ, G. J., & Harrison, B. S. (2015) · Stem Cell Research · doi:10.1016/j.scr.2015.04.009 · Cited by 166
“30 Hz frequencies during quiet muscle activity (standing), and b10 Hz while walking (Antonsson and Mann, 1985).”
BackgroundTime-Varying Ankle Mechanical Impedance During Human Locomotion
Lee, H., & Hogan, N. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346927 · Cited by 162
“In fact, 98% of power in normal human walking is contained below 10 Hz and 99% below 15 Hz [24].”
BackgroundWearable Hardware Design for the Internet of Medical Things (IoMT)
Qureshi, F., & Krishnan, S. (2018) · Sensors · doi:10.3390/s18113812 · Cited by 158
“[5,8,12,13] respectively.”
Shin, J. H., Kwon, J., Kim, J. U., Ryu, H., Ok, J., Joon Kwon, S., Park, H., & Kim, T.-I. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00164-w · Cited by 123
“The dominant P300 frequency band perfectly matches the dominant frequency band of motion artifacts below 4 Hz 48,49 ; thus, motion artifacts can easily distort the P300 signal (Fig.”
BackgroundSamà, A., Rodríguez-Martín, D., Pérez-López, C., Català, A., Alcaine, S., Mestre, B., Prats, A., Crespo, M. C., & Bayés, À. (2018) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.05.009 · Cited by 76
Validation of a Portable Device for Mapping Motor and Gait Disturbances in Parkinson’s Disease
Rodríguez-Molinero, A., Samà, A., Pérez-Martínez, D. A., Pérez López, C., Romagosa, J., Bayés, À., Sanz, P., Calopa, M., Gálvez-Barrón, C., de Mingo, E., et al. (2015) · JMIR mHealth and uHealth · doi:10.2196/mhealth.3321 · Cited by 64
Parkus: a novel vehicle parking detection system
Carnelli, P., Yeh, J., Sooriyabandara, M., & Khan, A. (2017) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v31i2.19090 · Cited by 27
Lackner, J. R., & DiZio, P. (1992) · The Head-Neck Sensory Motor System · doi:10.1093/acprof:oso/9780195068207.003.0033 · Cited by 11
Metadata
- Authors
- Antonsson, E. K., & Mann, R. W.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1985-01
- Volume
- 18
- Issue
- 1
- Pages
- 39-47
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2037643601
- Cited by
- 570
- References
- 15
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.