The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Cuticular pad–inspired selective frequency damper for nearly dynamic noise–free bioelectronics
Abstract
Bioelectronics needs to continuously monitor mechanical and electrophysiological signals for patients. However, the signals always include artifacts by patients’ unexpected movement (such as walking and respiration under approximately 30 hertz). The current method to remove them is a signal process that uses a bandpass filter, which may cause signal loss. We present an unconventional bandpass filter material—viscoelastic gelatin-chitosan hydrogel damper, inspired by the viscoelastic cuticular pad in a spider—to remove dynamic mechanical noise artifacts selectively. The hydrogel exhibits frequency-dependent phase transition that results in a rubbery state that damps low-frequency noise and a glassy state that transmits the desired high-frequency signals. It serves as an adaptable passfilter that enables the acquisition of high-quality signals from patients while minimizing signal process for advanced bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationUltrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Self-citationA skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Artificial multimodal receptors based on ion relaxation dynamics
You, I., Mackanic, D. G., Matsuhisa, N., Kang, J., Kwon, J., Beker, L., Mun, J., Suh, W., Kim, T. Y., Tok, J. B.-H., et al. (2020) · Science · doi:10.1126/science.aba5132 · Cited by 632
Self-citationA wireless body area sensor network based on stretchable passive tags
Niu, S., Matsuhisa, N., Beker, L., Li, J., Wang, S., Wang, J., Jiang, Y., Yan, X., Yun, Y., Burnett, W., et al. (2019) · Nature Electronics · doi:10.1038/s41928-019-0286-2 · Cited by 601
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Cited by
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Xiang, H., Li, X., Wu, B., Sun, S., & Wu, P. (2023) · Advanced Materials · doi:10.1002/adma.202209581 · Cited by 268
Song, H., Kim, M., Kim, E., Lee, J., Jeong, I., Lim, K., Ryu, S. Y., Oh, M., Kim, Y., & Park, J. (2024) · BMEMat · doi:10.1002/bmm2.12048 · Cited by 61
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 9
Reprogramming Multi‐Dimensional Material Properties of Cured Thermosets by Hot‐Pressing
Yang, Z., Liang, H., Lei, T., Yang, Y., Wang, X., Zhou, Y., Wu, M., He, E., Wang, Y., Zhang, S., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.78148
Metadata
- Authors
- Park, B., Shin, J. H., Ok, J., Park, S., Jung, W., Jeong, C., Choy, S., Jo, Y. J., & Kim, T.-I.
- Venue
- Science
- Published
- 2022-05-06
- Volume
- 376
- Issue
- 6593
- Pages
- 624-629
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4229000069
- Cited by
- 244
- References
- 13
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cuticular pad–inspired selective frequency damper for nearly dynamic noise–free bioelectronics. https://app.cochat.ai/papers/10.1126/science.abj9912
- The paper
- Park, B., Shin, J. H., Ok, J., Park, S., Jung, W., Jeong, C., Choy, S., Jo, Y. J., & Kim, T.-I. (2022). Cuticular pad–inspired selective frequency damper for nearly dynamic noise–free bioelectronics. Science. https://doi.org/10.1126/science.abj9912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.