Biphasic indentation of articular cartilage—II. A numerical algorithm and an experimental study
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Part I (Mak et al., 1987, J. Biomechanics 20, 703-714) presented the theoretical solutions for the biphasic indentation of articular cartilage under creep and stress-relaxation conditions. In this study, using the creep solution, we developed an efficient numerical algorithm to compute all three material coefficients of cartilage in situ on the joint surface from the indentation creep experiment. With this method we determined the average values of the aggregate modulus. Poisson's ratio and permeability for young bovine femoral condylar cartilage in situ to be HA = 0.90 MPa, vs = 0.39 and k = 0.44 x 10(-15) m4/Ns respectively, and those for patellar groove cartilage to be HA = 0.47 MPa, vs = 0.24, k = 1.42 x 10(-15) m4/Ns. One surprising finding from this study is that the in situ Poisson's ratio of cartilage (0.13-0.45) may be much less than those determined from measurements performed on excised osteochondral plugs (0.40-0.49) reported in the literature. We also found the permeability of patellar groove cartilage to be several times higher than femoral condyle cartilage. These findings may have important implications on understanding the functional behavior of cartilage in situ and on methods used to determine the elastic moduli of cartilage using the indentation experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ueber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationMortenson, M. E. (1985) · Cited by 1,475
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationA mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Self-citationUber die Beruhrung fester elastischer Korper
Hertz, H. G. (1882) · Medical Entomology and Zoology · Cited by 719
Biphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478
Self-citationViscoelastic properties of human articular cartilage.
Hayes, W. C., & Mockros, L. F. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.562 · Cited by 306
Kempson, G. E., Freeman, M. A. R., & Swanson, S. A. V. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90030-3 · Cited by 192
Cited by
Mesenchymal cell-based repair of large, full-thickness defects of articular cartilage.
Wakitani, S., Goto, T., Pineda, S. J., Young, R. G., Mansour, J. M., Caplan, A. I., & Goldberg, V. M. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199404000-00013 · Cited by 1,605
Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage
Athanasiou, K. A., Rosenwasser, M. P., Buckwalter, J. A., Malinin, T. I., & Mow, V. C. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090304 · Cited by 750
Self-citationNanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Self-citationSetton, L. A., Elliott, D. M., & Mow, V. C. (1999) · Osteoarthritis and Cartilage · doi:10.1053/joca.1998.0170 · Cited by 378
Self-citationAn asymptotic solution for the contact of two biphasic cartilage layers
Ateshian, G. A., Lai, W. M., Zhu, W. B., & Mow, V. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90044-2 · Cited by 350
Self-citationOptical and mechanical determination of poisson's ratio of adult bovine humeral articular cartilage
Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00133-9 · Cited by 344
Athanasiou, K. A., Agarwal, A., & Dzida, F. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120306 · Cited by 343
Self-citationSoltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Setton, L. A., Zhu, W., & Mow, V. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90019-b · Cited by 316
Self-citationMechanical Properties of Natural Cartilage and Tissue-Engineered Constructs
Little, C. J., Bawolin, N. K., & Chen, X. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0572 · Cited by 314
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Foundations of multiphasic and porous materials
Ehlers, W. (2002) · Porous Media · doi:10.1007/978-3-662-04999-0_1 · Cited by 294
Kleemann, R. U., Krocker, D., Cedraro, A., Tuischer, J., & Duda, G. N. (2005) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.06.008 · Cited by 283
Zhang, M., Zheng, Y. P., & Mak, A. F. T. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00017-9 · Cited by 282
Biomechanics of Articular Cartilage and Determination of Material Properties
LU, X. L., & MOW, V. C. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815cb1fc · Cited by 253
Self-citationWakitani, S., Goto, T., Young, R. G., Mansour, J. M., Goldberg, V. M., & Caplan, A. I. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.429 · Cited by 250
“Cartilage thickness and indentation depth were measured using procedures developed by Mow et al. 38 as modified in our laboratory by Matsuura et al. 39 for generating a simplified estimate of the "compliance" of the reparative cartilage.”
Single‐Cell Elastography: Probing for Disease with the Atomic Force Microscope
Costa, K. D. (2004) · Disease Markers · doi:10.1155/2004/482680 · Cited by 233
“Indentation is an alternative approach for identifying in-plane material properties of biological tissues [48, 49].”
BackgroundBiomechanical topography of human ankle cartilage
Athanasiou, K. A., Niederauer, G. G., & Schenck, R. C. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584467 · Cited by 216
Self-citationStrategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
Ateshian, G. A., Rajan, V., Chahine, N. O., Canal, C. E., & Hung, C. T. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3118773 · Cited by 199
“For example, the linear isotropic biphasic theory for soft hydrated tissues [13] can predict the transient response of cartilage deformation and interstitial fluid pressurization in confined compression creep, stress-relaxation, and dynamic loading [13– 16], and indentation creep [17].”
BackgroundHuang, C.-Y., Soltz, M. A., Kopacz, M., Mow, V. C., & Ateshian, G. A. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1531656 · Cited by 198
Self-citationMechanical Properties of Tissue
Duck, F. A. (1990) · Physical Properties of Tissues · doi:10.1016/b978-0-12-222800-1.50009-7 · Cited by 175
Zheng, Y. P., Choi, Y. K. C., Wong, K., Chan, S., & Mak, A. F. T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00163-5 · Cited by 171
Immunochemical and Mechanical Characterization of Cartilage Subtypes in Rabbit
Naumann, A., Dennis, J. E., Awadallah, A., Carrino, D. A., Mansour, J. M., Kastenbauer, E., & Caplan, A. I. (2002) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540205000807 · Cited by 170
“By curve-fitting the experimental creep curves with the master solution via a nonlinear regression procedure, the intrinsic material properties (aggregate modulus, Poisson’s ratio, and permeability) of the different cartilage subtypes were calculated (Mak et al. 1987; Mow et al. 1989).”
MethodInfluentialWayne, J. S., McDowell, C. L., Shields, K. J., & Tuan, R. S. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.953 · Cited by 162
“31,33”
Li, W.-J., Chiang, H., Kuo, T.-F., Lee, H.-S., Jiang, C.-C., & Tuan, R. S. (2009) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.127 · Cited by 160
“The tensile stress-relaxation property of each specimen was determined by an unconfined uniaxial indentation test using a custom-designed mechanical tester (Mak et al., 1987; Mow et al., 1989) as described previously (Chiang et al., 2005).”
MethodComputational aspects in mechanical modeling of the articular cartilage tissue
Mohammadi, H., Mequanint, K., & Herzog, W. (2013) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411912470239 · Cited by 28
Metadata
- Authors
- Mow, V. C., Gibbs, M. C., Lai, W. M., Zhu, W. B., & Athanasiou, K. A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1989
- Volume
- 22
- Issue
- 8-9
- Pages
- 853-861
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1969711196
- Cited by
- 509
- References
- 16
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.