Hip impact velocities and body configurations for voluntary falls from standing height
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tinetti, M. E., Baker, D. I., McAvay, G., Claus, E. B., Garrett, P., Gottschalk, M., Koch, M. L., Trainor, K., & Horwitz, R. I. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409293311301 · Cited by 2,147
Cummings, S. R., Rubin, S. M., & Black, D. (1990) · PubMed · Cited by 635
Fall Severity and Bone Mineral Density as Risk Factors for Hip Fracture in Ambulatory Elderly
Greenspan, S. L. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510260060029 · Cited by 588 · cited 3×
“From a surveillance study among nursing home fallers, Greenspan et al. (1994) reported that the greatest risk factor for fracture was falling to the side, followed by a factor measuring bone mineral density and other factors measuring body habitus and the potential energy available in the fall.”
BackgroundType of Fall and Risk of Hip and Wrist Fractures: The Study of Osteoporotic Fractures
Nevitt, M. C., Cummings, S. R., & Study of Osteoporotic Fractures Research Group (1993) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1993.tb07307.x · Cited by 561 · cited 1×
“In this study, we focused on sideways falls only, with impact on the hip or side of leg, since such a fall has the highest risk for hip fracture (Greenspan et al., 1994; Hayes et al., 1993; Nevitt and Cummings, 1993).”
Local and Systemic Factors in the Pathogenesis of Osteoporosis
Epstein, F. H., & Raisz, L. G. (1988) · New England Journal of Medicine · doi:10.1056/nejm198803313181305 · Cited by 493
Cost of injury in the United States: A report to Congress: (572142009-001)
Rice, D. P., MacKenzie, E. J., Jones, A. S., Kaufman, S. R., deLissovoy, G. V., Max, W., McLoughlin, E., Miller, T. R., Robertson, L. S., Salkever, D. S., et al. (1989) · PsycEXTRA Dataset · doi:10.1037/e572142009-001 · Cited by 484
TYPE OF FALL AND RISK OF HIP AND WRIST FRACTURES: THE STUDY OF OSTEOPOROTIC FRACTURES
Drinka, P. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb06547.x · Cited by 475
Epidemiology of Fractures of the Proximal Femur in Rochester, Minnesota
GALLAGHER, J. C., MELTON, L. J., RIGGS, B. L., & BERGSTRATH, E. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00027 · Cited by 445 · cited 1×
“However, the increase in risk of a hip fracture for elderly persons compared to a middle-age population is more than ten times larger than the increase in the incidence of falls in the elderly (Fitti, 1987; Gallagher et al., 1980).”
BackgroundImpact near the hip dominates fracture risk in elderly nursing home residents who fall
Hayes, W. C., Myers, E. R., Morris, J. N., Gerhart, T. N., Yett, H. S., & Lipsitz, L. A. (1993) · Calcified Tissue International · doi:10.1007/bf00298717 · Cited by 436
Self-citationA HYPOTHESIS: The Causes of Hip Fractures
Cummings, S. R., & Nevitt, M. C. (1989) · Journal of Gerontology · doi:10.1093/geronj/44.4.m107 · Cited by 414
Cited by
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
Bourke, A. K., O’Brien, J. V., & Lyons, G. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.012 · Cited by 821
Parkkari, J., Kannus, P., Palvanen, M., Natri, A., Vainio, J., Aho, H., Vuori, I., & Järvinen, M. (1999) · Calcified Tissue International · doi:10.1007/s002239900679 · Cited by 563
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
Composable controllers for physics-based character animation
Faloutsos, P., van de Panne, M., & Terzopoulos, D. (2001) · Proceedings of the 28th annual conference on Computer graphics and interactive techniques · doi:10.1145/383259.383287 · Cited by 331
Common protective movements govern unexpected falls from standing height
Hsiao, E. T., & Robinovitch, S. N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00114-0 · Cited by 260
A wearable system for pre-impact fall detection
Nyan, M. N., Tay, F. E. H., & Murugasu, E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.009 · Cited by 241
“…include physical restraint (Gross et al., 1990), investigation of fall-related fractures prevention strategies (Smeesters et al., 2001; Van den Kroonenberg et al., 1996; Yamamoto et al., 2006), study of characteristics and risk factors of syncope (Kenny and O’Shea, 2002; Peczalski et al.,…”
BackgroundBiomechanics of Osteoporosis and Vertebral Fracture
Myers, E. R., & Wilson, S. E. (1997) · Spine · doi:10.1097/00007632-199712151-00005 · Cited by 239
Reduction in proximal femoral strength due to long-duration spaceflight
Keyak, J. H., Koyama, A. K., LeBlanc, A., Lu, Y., & Lang, T. F. (2009) · Bone · doi:10.1016/j.bone.2008.11.014 · Cited by 236
“The force for a posterolateral fall also cannot be estimated from experimental and modeling studies, as performed previously, because those studies examined falls directly to the side [17–21].”
ResultPortable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
“the configuration and velocity of the body at impact, is found to be the primary predictor of hip fracture risk [24], [25].”
BackgroundBouxsein, M. L., Szulc, P., Munoz, F., Thrall, E., Sornay-Rendu, E., & Delmas, P. D. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070309 · Cited by 217
Pinilla, T. P., Boardman, K. C., Bouxsein, M. L., Myers, E. R., & Hayes, W. C. (1996) · Calcified Tissue International · doi:10.1007/bf02508641 · Cited by 208
Self-citationDistinguishing fall activities from normal activities by velocity characteristics
Wu, G. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00117-2 · Cited by 192
Disturbance type and gait speed affect fall direction and impact location
Smeesters, C., Hayes, W. C., & McMahon, T. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00200-1 · Cited by 182
Self-citationFeldman, F., & Robinovitch, S. N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.01.019 · Cited by 168
“This differs from van den Kroonenberg et al.’s (1996) finding that impact to the hip precedes impact to the hand during sideways falls.”
ResultSafe landing strategies during a fall: Systematic review and meta-analysis
Moon, Y., & Sosnoff, J. J. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.08.460 · Cited by 79
Development and Validation of a Predictive Bone Fracture Risk Model for Astronauts
Nelson, E. S., Lewandowski, B., Licata, A., & Myers, J. G. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9779-x · Cited by 50
Metadata
- Authors
- van den Kroonenberg, A. J., Hayes, W. C., & McMahon, T. A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-06
- Volume
- 29
- Issue
- 6
- Pages
- 807-811
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2070347155
- Cited by
- 181
- References
- 17
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.