Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 201–300 of 1,000
Realization of the permanent magnet undulator Noel
Ortéga, J. M., Bazin, C., Deacon, D. A. G., Depautex, C., & Elleaume, P. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)91269-3 · Cited by 38
A Review of Technology Readiness Levels for Superconducting Electric Machinery
Santos, B. M. O., Dias, F. J. M., Trillaud, F., Sotelo, G. G., & Junior, R. D. A. (2023) · Energies · doi:10.3390/en16165955 · Cited by 37
Cryocoolers for aircraft superconducting generators and motors
Radebaugh, R. (2012) · AIP conference proceedings · doi:10.1063/1.4706918 · Cited by 37
Multiphysical analysis of moving-magnet planar motor topologies
Rovers, J. M. M., Jansen, J. W., & Lomonova, E. A. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2273060 · Cited by 37
“This motor consists of a translator with four linear Halbach arrays [4] levitated above a stator with four coil segments.”
Design and simulation of superconducting Lorentz Force Electrical Impedance Tomography (LFEIT)
Shen, B., Fu, L. Z., Geng, J., Zhang, X., Zhang, H., Dong, Q., Li, C., Li, J., & Coombs, T. A. (2016) · Physica C Superconductivity · doi:10.1016/j.physc.2016.02.023 · Cited by 37
Yan, C., Sun, Z., Zhang, W., & Chen, Q. (2016) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-016-0106-9 · Cited by 37
Compact magnets for magnetic resonance
Demas, V., & Prado, P. J. (2009) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20131 · Cited by 37
Permanent magnets for Faraday rotators inspired by the design of the magic sphere
Trénec, G., Volondat, W., Cugat, O., & Vigué, J. (2011) · Applied Optics · doi:10.1364/ao.50.004788 · Cited by 37
“These properties make it possible to produce very strong magnetic fields with permanent magnets [37,38].”
BackgroundMagnetic Field Created by Tile Permanent Magnets
Ravaud, R., Lemarquand, G., & Lemarquand, V. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2014752 · Cited by 37
The trigger and data acquisition system of the FASER experiment
Abreu, H., Mansour, E. A., Antel, C., Ariga, A., Ariga, T., Bernlochner, F. U., Boeckh, T., Boyd, J., Brenner, L., Cadoux, F., et al. (2021) · Journal of Instrumentation · doi:10.1088/1748-0221/16/12/p12028 · Cited by 36
“They are based on a Halbach array design [7], which maximizes the field without the need for complicated support infrastructure.”
MethodOptimizing dissolution dynamic nuclear polarization
Bornet, A., & Jannin, S. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.12.007 · Cited by 48
Oxygen adsorption on surfaces studied by a spin- and alignment-controlled O 2 beam
Kurahashi, M. (2016) · Progress in Surface Science · doi:10.1016/j.progsurf.2016.03.001 · Cited by 40
High Flow-Rate Benchtop NMR Spectroscopy Enabled by Continuous Overhauser DNP
Kircher, R., Hasse, H., & Münnemann, K. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01118 · Cited by 38
Numerical model of electron cyclotron resonance ion source
Mironov, V., Bogomolov, S. L., Bondarchenko, A. E., Efremov, A., & Логинов, В. Н. (2015) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.18.123401 · Cited by 36
Sun, R., Zheng, J., Zheng, B., Qian, N., Li, J., & Deng, Z. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.08.082 · Cited by 36
A New Design for a Compact Centrifugal Blood Pump with a Magnetically Levitated Rotor
Asama, J., Shinshi, T., Hoshi, H., Takatani, S., & Shimokohbe, A. (2004) · ASAIO Journal · doi:10.1097/01.mat.0000144364.62671.5a · Cited by 36
Magnetically levitated planar actuator with moving magnets:electromechanical analysis and design
Jansen, J. W. (2007) · TU/e Research Portal · doi:10.6100/ir630846 · Cited by 36
MHD PbLi experiments in MaPLE loop at UCLA
Courtessole, C., Smolentsev, S., Sketchley, T., & Abdou, M. (2016) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2016.01.032 · Cited by 35
Homopolar Bearingless Slice Motor With Flux-Biasing Halbach Arrays
Noh, M., & Trumper, D. L. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2942512 · Cited by 35
“This characteristic can be attributed to the Halbach array that can be modeled as a flux source in parallel with a relatively large source reluctance.”
InfluentialThe metastable Q 3Δ2 state of ThO: a new resource for the ACME electron EDM search
Wu, X., Han, Z., Chow, J., Ang, D. G., Meisenhelder, C., Panda, C. D., West, E. P., Gabrielse, G., Doyle, J. M., & DeMille, D. (2020) · New Journal of Physics · doi:10.1088/1367-2630/ab6a3a · Cited by 35
Experimentally Testing a Halbach Rotor Coaxial Magnetic Gear With 279 Nm/L Torque Density
Wong, H. Y., Baninajar, H., Dechant, B., Southwick, P., & Bird, J. Z. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3208320 · Cited by 35
“highly sinusoidal field distributions [11] and therefore a Halbach rotor offers the potential for both increased torque density and lower harmonic related loss.”
BackgroundNovel Magnetic Sensing Approach with Improved Linearity
Fontana, M., Salsedo, F., & Bergamasco, M. (2013) · Sensors · doi:10.3390/s130607618 · Cited by 35
Solving Large-Scale Inverse Magnetostatic Problems using the Adjoint Method
Bruckner, F., Abert, C., Wautischer, G., Huber, C., Vogler, C., Hinze, M., & Suess, D. (2017) · Scientific Reports · doi:10.1038/srep40816 · Cited by 42
“The analytic solution for a cylindical Halbach array [15] can be expressed in cylindrical coordinates as”
2D hall sensor array for measuring the position of a magnet matrix
Ahn, H. J., & Kim, K. R. (2014) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-014-0017-0 · Cited by 34
“Halbach magnet array can significantly reduce harmonic components of magnetic flux density.(14,16) In addition, periodic (harmonic) signals can be separated using multi-sensors (or sensor array).”
BackgroundMuscular MEMS—the engineering of liquid crystal elastomer actuators
Petsch, S., Khatri, B., Schuhladen, S., Köbele, L., Rix, R., Zentel, R., & Zappe, H. P. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/8/085010 · Cited by 34
Bashyam, A., Li, M., & Cima, M. J. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.05.004 · Cited by 34
Tewari, S., O’Reilly, T., & WEBB, A. G. (2021) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2021.106923 · Cited by 34
Time-domain NMR in polyolefin research
Litvinov, V. M., & Men, Y. (2022) · Polymer · doi:10.1016/j.polymer.2022.125205 · Cited by 36
Determining the minimum mass and cost of a magnetic refrigerator
Bjørk, R., Smith, A., Bahl, C. R. H., & Pryds, N. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.05.021 · Cited by 34
“However, we will also consider the Halbach cylinder [Mallinson, 1973; Halbach, 1980] which is a magnet design that has previously been used extensively in magnetic refrigeration devices [Lu et al., 2005; Tura and Rowe, 2007; Engelbrecht et al., 2009; Kim and Jeong, 2009].”
MethodA high figure of merit vibrational energy harvester for low frequency applications
Nico, V., Boco, E., Frizzell, R., & Punch, J. M. (2016) · Applied Physics Letters · doi:10.1063/1.4939545 · Cited by 34
Four-level N -scheme crossover resonances in Rb saturation spectroscopy in magnetic fields
Scotto, S., Ciampini, D., Rizzo, C., & Arimondo, E. (2015) · Physical Review A · doi:10.1103/physreva.92.063810 · Cited by 37
“A 8-pole Halbach-like [27] magnetic field configuration, similar to those described in [28–30], provides a uniform field within the laser-atom interaction region.”
MethodGlobally Optimal Segmentation of Permanent-Magnet Systems
Insinga, A. R., Bjørk, R., Smith, A., & Bahl, C. R. H. (2016) · Physical Review Applied · doi:10.1103/physrevapplied.5.064014 · Cited by 33
“This implies that segmenting the Halbach magnet into N pieces will result in a reduction of the value of S according to the familiar formula [21]:”
BackgroundHuang, H., Jing, L., Qu, R., & Li, D. (2017) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2017.2785399 · Cited by 33
“S INCE Halbach PM array been proposed by Halbach [1], it gets a lot of attentions due to many attractive features it offers: sinusoidal flux distribution, self-shielding effect, higher fundamental field, low cogging torque and so on [2]–[5].”
BackgroundA Mobile DNP Polarizer for Clinical Applications
Münnemann, K., Bauer, C., Schmiedeskamp, J., Spiess, H. W., Schreiber, W., & Hinderberger, D. (2008) · Applied Magnetic Resonance · doi:10.1007/s00723-008-0130-8 · Cited by 33
Conceptual design of a permanent quadrupole magnet with adjustable strength
Halbach, K. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)90368-x · Cited by 33
Self-citationRudolf, A., & Walther, T. (2012) · Optics Letters · doi:10.1364/ol.37.004477 · Cited by 32
Permanent Magnet-Based Quadrupoles for Plasma Acceleration Sources
Ghaith, A., Espinós, D. O., Kitégi, C., Valléau, M., Marteau, F., & Couprie, M.-E. (2019) · Instruments · doi:10.3390/instruments3020027 · Cited by 37
“Concerning the quadrupole, and considering a long magnetic length (L) the gradient can be expressed as follows [37]: { G = 2BrK( 1 Ri − 1 Ro ) K = M 2π cos 2( π M )sin( 2π M ) (4)”
BackgroundCompact 14.5 GHz all-permanent magnet ECRIS for experiments with slow multicharged ions
Galutschek, E., Trassl, R., Salzborn, E., Aumayr, F., & Winter, H. P. (2007) · Journal of Physics Conference Series · doi:10.1088/1742-6596/58/1/090 · Cited by 32
Characteristics of an Electrodynamic Wheel Using a 2-D Steady-State Model
Bird, J. Z., & Lipo, T. A. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.900572 · Cited by 32
“analysis will focus on the use of rare-earth magnets with a Halbach array [36]–[38].”
BackgroundWang, J., Lin, H., & Fang, S. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2529587 · Cited by 32
“Quasi-Halbach structures can be exploited to achieve an even higher power density with an increased amount of PM material [11], to attain an essentially sinusoidal air-gap field distribution, and to arrive at a state of self-shielding [12].”
BackgroundPrinciples and Design of a Zeeman–Sisyphus Decelerator for Molecular Beams
Fitch, N. J., & Tarbutt, M. R. (2016) · ChemPhysChem · doi:10.1002/cphc.201600656 · Cited by 32
Topology optimization of Halbach magnet arrays using isoparametric projection
Lee, J., Nomura, T., & Dede, E. M. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.01.092 · Cited by 32
Kumar, R., Hosseinzadehtaher, M., Hein, N. T., Shadmand, M. B., Jagadish, S. V. K., & Ghanbarian, B. (2022) · Frontiers in Plant Science · doi:10.3389/fpls.2022.1036078 · Cited by 35
“This is due to a uniform flux that is generated based on the orientation of segmented Frontiers in Plant Science 10 magnets in the Halbach arrays (Halbach, 1980).”
MethodPermanent-magnet Faraday isolator with the field intensity of more than 3 tesla
Mironov, É. A., Voitovich, A. V., & Palashov, O. V. (2019) · Laser Physics Letters · doi:10.1088/1612-202x/ab4fe3 · Cited by 31
Small electromagnetic acoustic transducer with an enhanced unique magnet configuration
Sun, H., Urayama, R., Uchimoto, T., Takagi, T., & Hashimoto, M. (2019) · NDT & E International · doi:10.1016/j.ndteint.2019.102205 · Cited by 31
Inverse Design of Magnetic Fields Using Deep Learning
Pollok, S., Bjørk, R., & Jørgensen, P. S. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3082431 · Cited by 32
“Such optimized magnet structures can in the simplest cases be analytically found, such as the Halbach cylinder [1], or through numerical methods [2], [3].”
Shi, H., Ke, Z., Zheng, J., Xiang, Y., Ren, K., Lin, P., Li, K., Zhu, H., Liang, L., & Deng, Z. (2023) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2023.3245620 · Cited by 31
Tang, J., Fang, J., & Wen, W. (2012) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2012.2218245 · Cited by 31
“4 shown in the stator and five Halbach-type-arranged [24] NdFeB PM rings in the rotor.”
BackgroundHugon, C., Aguiar, P. M., Aubert, G., & Sakellariou, D. (2010) · Comptes Rendus Chimie · doi:10.1016/j.crci.2009.09.009 · Cited by 31
New Linear Motor Concepts for Artificial Hearts
Finocchiaro, T., Butschen, T., Kwant, P. B., Steinseifer, U., Schmitz‐Rode, T., Hameyer, K., & Leßmann, M. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.916110 · Cited by 31
Integrated multidimensional positioner for precision manufacturing
Kim, W., Bhat, N., & Hu, T. (2004) · Proceedings of the Institution of Mechanical Engineers Part B Journal of Engineering Manufacture · doi:10.1243/095440504323055542 · Cited by 31
Commissioning of the PRIOR proton microscope
Varentsov, D., Antonov, O., Bakhmutova, A. V., Barnes, C. W., Bogdanov, A. V., Danly, C. R., Efimov, S. Y., Endres, M., Fertman, A., Golubev, A. A., et al. (2016) · Review of Scientific Instruments · doi:10.1063/1.4941685 · Cited by 31
Topology optimization of permanent magnets for stellarators
Zhu, C., Hammond, K. C., Brown, T., Gates, D., ZARNSTORFF, M. C., Corrigan, K., Sibilia, M., & Feibush, E. A. (2020) · Nuclear Fusion · doi:10.1088/1741-4326/aba453 · Cited by 31
“he magnets present only at the places ˆ>0:9. 4.2Permanent magnets with arbitrary orientations We can now relax the restriction of orientation to improve the magnetic efficiency. The “Halbach” array [26] can improve the magnetic efficiency by a factor of two in simple 1D and 2D cases. Thus, we can try to reduce the th…”
BackgroundGeneration of a static magnetic field-free line using two Maxwell coil pairs
Knopp, T., Erbe, M., Sattel, T. F., Biederer, S., & Buzug, T. M. (2010) · Applied Physics Letters · doi:10.1063/1.3486118 · Cited by 30
Optimization study on the magnetic field of superconducting Halbach Array magnet
Shen, B., Geng, J., Li, C., Zhang, X., Fu, L. Z., Zhang, H., Ma, J., & Coombs, T. A. (2017) · Physica C Superconductivity · doi:10.1016/j.physc.2017.05.009 · Cited by 30
“to the low cost and easy maintenance [4].”
BackgroundAbhyankar, N., Agrawal, A. K., Campbell, J. P., Maly, T., Shrestha, P. R., & Szalai, V. A. (2022) · Review of Scientific Instruments · doi:10.1063/5.0097853 · Cited by 36
Halbach array linear alternator for thermo-acoustic engine
Saha, C., Riley, P. H., Paul, J., Yu, Z., Jaworski, A. J., & Johnson, C. M. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.01.042 · Cited by 30
Demas, V., & Lowery, T. J. (2011) · New Journal of Physics · doi:10.1088/1367-2630/13/2/025005 · Cited by 43
Analysis of 3-D Effects in Segmented Cylindrical Quasi-Halbach Magnet Arrays
Meessen, K. J., Paulides, J. J. H., & Lomonova, E. A. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2101079 · Cited by 30
“For example, Halbach structures are used to enhance the power density [1]–[3].”
MethodThree-Dimensional Magnetic Field Modeling of a Cylindrical Halbach Array
Meessen, K. J., Gysen, B. L. J., Paulides, J. J. H., & Lomonova, E. A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2042038 · Cited by 30
“For example, Halbach structures are exploited to achieve an even higher power density with an increased amount of PM material [1].”
BackgroundA High Torque Density Halbach Rotor Coaxial Magnetic Gear
Wong, H. Y., Bird, J. Z., Barnett, D., & Williams, W. B. (2019) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2019.8785188 · Cited by 30
“Halbach rotor structures are well-known for creating highly sinusoidal field distributions [8] and therefore offer the potential for both increasing torque density and lowering harmonic related losses.”
BackgroundLee, M. G., & Gweon, D. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2004.03.052 · Cited by 30
A novel transverse flux machine for vehicle traction aplications
Wan, Z., Ahmed, A., Husain, I., & Muljadi, E. (2015) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2015.7286494 · Cited by 29
“Such a magnet arrangement when combined with rotor cores creates a flux pattern similar to that of a Halbach array [11].”
BackgroundAdvances in Reconfigurable Vectorial Thrusters for Adaptive Underwater Robots
Gasparoto, H. F., Chocron, O., Benbouzid, M., & Meirelles, P. S. (2021) · Journal of Marine Science and Engineering · doi:10.3390/jmse9020170 · Cited by 29
“However, the best idea until now, comes with a “magnetic curiosity” discovered in [88] and after in [89], which nowadays is known as Halbach arrays.”
BackgroundJiang, Y., Deng, Y., Zhu, P., Yang, M., & Zhou, F. (2021) · IEEE Access · doi:10.1109/access.2021.3058124 · Cited by 29
“This magnet pattern is commonly called a Halbach Array [4], although Mallinson first discovered the array with the so-called one-sided flux [5], moreover, it is a promising magnet pattern due to its self-shielding property and sinusoidally distributed magnetic field in air space [6].”
BackgroundRobot Crawler for Surveying Pipelines and Metal Structures of Complex Spatial Configuration
Пшенин, В. В., Liagova, A., Razin, A., Skorobogatov, A. A., & Komarovsky, M. (2022) · Infrastructures · doi:10.3390/infrastructures7060075 · Cited by 29
The ideal dimensions of a Halbach cylinder of finite length
Bjørk, R. (2011) · Journal of Applied Physics · doi:10.1063/1.3525646 · Cited by 29
Analysis of Trajectories for Targeting of Magnetic Nanoparticles in Blood Vessels
Heidsieck, A., Vosen, S., Zimmermann, K., Wenzel, D., & Gleich, B. (2012) · Molecular Pharmaceutics · doi:10.1021/mp3001155 · Cited by 29
Designing stellarators using perpendicular permanent magnets
Zhu, C., ZARNSTORFF, M. C., Gates, D., & Brooks, A. (2020) · Nuclear Fusion · doi:10.1088/1741-4326/ab9006 · Cited by 29
“Although this is rather modest compared to electromagnets especially considering that the strongest field outside the magnet is normally half of the residual field, special arrangements of permanent magnets, which are normally called Halbach arrays [13], can generate a much higher field.”
Super Strong Permanent Magnet Quadrupole for a Linear Collider
Mihara, T., Iwashita, Y., Kumada, М., Evgeny, A., & Spencer, C. M. (2004) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2004.829698 · Cited by 29
Magnetic Bearing Stage for Photolithography
Williams, M. E., Trumper, D. L., & Hocken, R. J. (1993) · CIRP Annals · doi:10.1016/s0007-8506(07)62520-7 · Cited by 29
DESIGN AND DEVELOPMENT OF HALBACH ELECTROMAGNET FOR ACTIVE MAGNETIC BEARING
Lijesh, K. P., & Hirani, H. (2015) · Progress In Electromagnetics Research C · doi:10.2528/pierc15011411 · Cited by 28
Permanent magnets for production and use of high energy particle beams
Halbach, K. (1985) · University of North Texas Digital Library (University of North Texas) · Cited by 28
Self-citationMagnetic cell delivery for peripheral arterial disease: A theoretical framework
Riegler, J., Lau, K. D., García-Prieto, A., Price, A. N., Richards, T., Pankhurst, Q. A., & Lythgoe, M. F. (2011) · Medical Physics · doi:10.1118/1.3593363 · Cited by 29
The polarized H and D atomic beam source for ANKE at COSY-Jülich
Mikirtychyants, M., Engels, R., Grigoryev, K., Kleines, H., Kravtsov, P. A., Lorenz, S., Nekipelov, M., Nelyubin, V., Rathmann, F., Sarkadi, J., et al. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.03.043 · Cited by 28
The role of coupling strength in the performance of electrodynamic vibrational energy harvesters
Challa, V. R., Cheng, S., & Arnold, D. P. (2012) · Smart Materials and Structures · doi:10.1088/0964-1726/22/2/025005 · Cited by 29
“The design goal is to alter the radial component of the magnetic field, which is equivalent to altering the gradient of the axial magnetic field, as has been studied in numerous works [24–27].”
MethodMironov, V. I., & Beijers, J. P. M. (2009) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.12.073501 · Cited by 31
Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure
Gohean, J. R., Larson, E. R., Hsi, B., Kurusz, M., Smalling, R. W., & Longoria, R. G. (2016) · ASAIO Journal · doi:10.1097/mat.0000000000000460 · Cited by 31
Semi-Analytical Modeling and Analysis of Halbach Array
Sim, M., & Ro, J. (2020) · Energies · doi:10.3390/en13051252 · Cited by 29
“Halbach to maximize the efficiency in a given volume of a permanent magnet (PM) via the combination of PMs, which are magnetized in diverse directions [1].”
BackgroundLow aberration permanent hexapole magnet for atom and molecular beam research
Dworski, S., Alexandrowicz, G., Fouquet, P., Jardine, A. P., Allison, W., & Ellis, J. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753093 · Cited by 28
High-pressure low-field 1H NMR relaxometry in nanoporous materials
Horch, C., Schlayer, S., & Frank Stallmach, A. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.01.002 · Cited by 28
Bauer, C., Raich, H., Jeschke, G., & Blümler, P. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.02.010 · Cited by 28
“These were referred at the time as a ‘‘magnetic curiosity”, and later realized by Klaus Halbach [16,17], who developed this idea further, and constructed arrangements of permanent multipole magnets, nowadays known as Halbach arrays.”
BackgroundHigh field permanent sextupole magnets for Stern Gerlach separation in atomic beam sources
Schiemenz, P., Ross, A., & Graw, G. (1991) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90513-p · Cited by 28
Analytical calculation of ironless loudspeaker motors
Berkouk, M., Lemarquand, V., & Lemarquand, G. (2001) · IEEE Transactions on Magnetics · doi:10.1109/20.917185 · Cited by 28
Compact and tunable focusing device for plasma wakefield acceleration
Pompili, R., Anania, M. P., Chiadroni, E., Cianchi, A., Ferrario, M., Lollo, V., Notargiacomo, A., Picardi, L., Ronsivalle, C., Rosenzweig, J. B., et al. (2018) · Review of Scientific Instruments · doi:10.1063/1.5006134 · Cited by 33
Surface Magnet Gears with a New Magnet Arrangement and Optimal Shape of Stationary Pole Pieces
Fujita, T., Ando, Y., NAGAYA, K., Oka, M., Todaka, T., Enokizono, M., & Sugiura, K. (2013) · Journal of Electromagnetic Analysis and Application · doi:10.4236/jemaa.2013.56039 · Cited by 27
“In the Halbach permanent magnet (HPM) arrangement [11], strong magnetic fields can form over a wide range, and the HPM arrangement generates a powerful sinusoiddal magnetic field on one side surface, but the magnetic field is small on the other side.”
BackgroundMaximally efficient permanent magnet structures
Jensen, J. H., & Abele, M. G. (1996) · Journal of Applied Physics · doi:10.1063/1.360914 · Cited by 27
Development of a compact MRI system for measuring the trabecular bone microstructure of the finger
Iita, N., Handa, S., Tomiha, S., & Kose, K. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21130 · Cited by 28
Nanomechanical Infrared Spectroscopy with Vibrating Filters for Pharmaceutical Analysis
Kurek, M., Carnoy, M., Larsen, P. E., Nielsen, L. H., Hansen, O., Rades, T., Schmid, S., & Boisen, A. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201700052 · Cited by 27
Analysis and implementation of a tubular motor with Halbach magnet array
Kim, W.-J., Berhan, M. T., Trumper, D. L., & Lang, J. H. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1996.557069 · Cited by 27
Xue, M., Xiang, A., Guo, Y., Wang, L., Wang, R., Wang, W., Ji, G., & Lu, Z. (2019) · RSC Advances · doi:10.1039/c9ra08285a · Cited by 26
Study of Permanent Magnet Electrodynamic Suspension System with a Novel Halbach Array
Luo, C., Zhang, K., Duan, J., & Jing, Y. (2020) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-019-00342-3 · Cited by 26
“Since Halbach array was proposed by American professor Klaus Halbach [1, 2], it has been successfully applied in particle accelerator, synchrotron radiation device and maglev system etc., due to its unique magnetic field feature (canceling the field on one side and enhancing the field on the opposite side) [3].”
MethodA method and device for online magnetic resonance multiphase flow detection
Deng, F., Xiong, C., Chen, S., Chen, G.-H., Wang, M., Liu, H., Zhang, J., Lei, Q., Cao, G., Dongping, X. U., et al. (2020) · Petroleum Exploration and Development · doi:10.1016/s1876-3804(20)60101-x · Cited by 26
Undulator design for a laser-plasma-based free-electron-laser
Ghaith, A., Couprie, M.-E., Espinós, D. O., Andriyash, I. A., Massimo, F., Clarke, J. A., Courthold, M. J. D., Bayliss, V., Bernhard, A., Trunk, M., et al. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.09.001 · Cited by 32
An electrodynamic wheel: an integrated propulsion and levitation machine
Bird, J. Z., & Lipo, T. A. (2003) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2003.1210636 · Cited by 26
Optimal Magnet Design for Lorentz Force Eddy-Current Testing
Weise, K., Schmidt, R., Carlstedt, M., Ziółkowski, M., Brauer, H., & Toepfer, H. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2427773 · Cited by 29
“These structures are typically termed Halbach arrays and find application in particle accelerators [15], high-speed motors/generators and servomotors [16], loudspeakers [17], magnetic bearings [18], [19], and nuclear magnetic resonance spectroscopy [20].”
BackgroundTesting helicity-dependentγγ→γγscattering in the region of MeV
Homma, K., Matsuura, K., & Nakajima, K. (2016) · Progress of Theoretical and Experimental Physics · doi:10.1093/ptep/ptv176 · Cited by 26
Boever, E. D., Foubert, A., Oligschläger, D., Claes, S., Soete, J., Bertier, P., Özkul, M., Virgone, A., & Swennen, R. (2016) · Geochemistry Geophysics Geosystems · doi:10.1002/2016gc006382 · Cited by 26
“Instruments The NMR measurements were conducted on two different low-field NMR sensors at the Institut f€ ur Technische und Makromolekulare Chemie - RWTH Aachen (Germany) that can be distinguished by their general magnet design [Halbach, 1980; Bl€ umich et al., 1998, 2014; Casanova et al., 2011] (Figure 4).”
MethodRichardson, P. M., Jackson, S., Parrott, A. J., Nordon, A., Duckett, S. B., & Halse, M. E. (2018) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.4687 · Cited by 31
Zhang, Y., Cao, J., Liao, W., Zhao, L., & Lin, J. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aad710 · Cited by 26
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.