Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621
“…19 to reduce external interferences and signal losses, development of new magnetic nanoparticles with higher R 2 relaxivity 20 , and design and construction of new permanent magnet assemblies 21 , 22 to increase the strength of the polarizing magnetic field ( B 0 ) for enhanced NMR signal level.”
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Coey, J. M. D. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00335-9 · Cited by 442
Physical and optical properties of rare earth cobalt magnets
Halbach, K. (1981) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0029-554x(81)90477-8 · Cited by 374
Self-citationCBETA: First Multipass Superconducting Linear Accelerator with Energy Recovery
Bartnik, A., Banerjee, N., Burke, D., Crittenden, J., Deitrick, K., Dobbins, J., Gulliford, C., Hoffstaetter, G., Li, Y., Lou, W., et al. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.044803 · Cited by 345
Polarized positrons and electrons at the linear collider
Moortgat-Pick, G., Abe, T., Alexander, G., Ananthanarayan, B., Babich, A. A., Bharadwaj, V., Barber, D., Bartl, A., Brachmann, A., Chen, S., et al. (2008) · Physics Reports · doi:10.1016/j.physrep.2007.12.003 · Cited by 294
High-precision magnetic levitation stage for photolithography
Kim, W.-J., & Trumper, D. L. (1998) · Precision Engineering · doi:10.1016/s0141-6359(98)00009-9 · Cited by 300
Raich, H., & Blümler, P. (2004) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20018 · Cited by 296
“[3–8].”
Wald, L. L., McDaniel, P. C., Witzel, T., Stockmann, J. P., & Cooley, C. Z. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26942 · Cited by 272
“24 Assembling the magnetized blocks into arrays leads to a wealth of interesting con fi gurations, many of which have recently been reviewed.”
A portable scanner for magnetic resonance imaging of the brain
Cooley, C. Z., McDaniel, P. C., Stockmann, J. P., Srinivas, S. A., Cauley, S. F., Śliwiak, M., Sappo, C. R., Vaughn, C. F., Guerin, B., Rosen, M. S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00641-5 · Cited by 251
A review of free-electron lasers
Roberson, C. W., & Sprangle, P. A. (1989) · Physics of Fluids B Plasma Physics · doi:10.1063/1.859102 · Cited by 262
Zalesskiy, S. S., Danieli, E., Blümich, B., & Ananikov, V. P. (2014) · Chemical Reviews · doi:10.1021/cr400063g · Cited by 232
Design and analysis framework for linear permanent-magnet machines
Trumper, D. L., Kim, W., & Williams, M. E. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.491486 · Cited by 224
Application of permanent magnets in accelerators and electron storage rings (invited)
Halbach, K. (1985) · Journal of Applied Physics · doi:10.1063/1.335021 · Cited by 222
Self-citationSmall Magnets for Portable NMR Spectrometers
Danieli, E., Perlo, J., Blümich, B., & Casanova, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000221 · Cited by 223
Analytical Magnetic Field Analysis of Halbach Magnetized Permanent-Magnet Machines
Xia, Z. P., Zhu, Z. Q., & Howe, D. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.828933 · Cited by 203
“The concept of Halbach magnetization was originally proposed by Halbach [ 2 ], although initially electrical machines employed segmented magnets which only approximated the Halbach magnetization [3], [4].”
BackgroundAnalytical Calculation of the Magnetic Field Created by Permanent-Magnet Rings
Ravaud, R., Lemarquand, G., Lemarquand, V., & Dépollier, C. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.923096 · Cited by 191
Surveying the plant’s world by magnetic resonance imaging
Borisjuk, L., Rolletschek, H., & Neuberger, T. (2012) · The Plant Journal · doi:10.1111/j.1365-313x.2012.04927.x · Cited by 181
Review and comparison of magnet designs for magnetic refrigeration
Bjørk, R., Bahl, C. R. H., Smith, A., & Pryds, N. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.12.012 · Cited by 177
“The magnetic structures presented in this subsection are all based on the Halbach cylinder design [Halbach, 1980; Mallinson, 1973].”
MethodTwo‐dimensional imaging in a lightweight portable MRI scanner without gradient coils
Cooley, C. Z., Stockmann, J., Armstrong, B. D., Sarracanie, M., Lev, M. H., Rosen, M. S., & Wald, L. L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25147 · Cited by 175
“This arrangement of permanent magnets produces an approximately uniform field directed transverse to the axis of the cylinder (22).”
Design and analysis framework for linear permanent magnet machines
Trumper, D. L., Kim, W., & Williams, M. E. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1994.377471 · Cited by 168
Furlani, E. P. (2001) · Elsevier eBooks · doi:10.1016/b978-012269951-1/50005-x · Cited by 164
A portable Halbach magnet that can be opened and closed without force: The NMR-CUFF
Windt, C. W., Soltner, H., van Dusschoten, D., & Blümler, P. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.09.020 · Cited by 161
“A second homogeneous, enclosing type of permanent magnet that is frequently used in portable NMR is the Halbach magnet [9–11].”
BackgroundDesign of a Halbach Magnet Array Based on Optimization Techniques
Choi, J.-S., & Yoo, J. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2001482 · Cited by 159
“This magnet pattern is commonly called a Halbach array [3] although Mallinson first discovered the array with the so-called one-sided flux [4].”
The PVLAS experiment: A 25 year effort to measure vacuum magnetic birefringence
Ejlli, A., Della Valle, F., Gastaldi, U., Messineo, G., Pengo, R., Ruoso, G., & Zavattini, G. (2020) · Physics Reports · doi:10.1016/j.physrep.2020.06.001 · Cited by 161
“The set-up comprised the construction and installation of two identical dipole magnets of the Halbach type [160], with B = 2.”
MethodThe Extremely Brilliant Source storage ring of the European Synchrotron Radiation Facility
Raimondi, P., Benabderrahmane, C., Berkvens, P., Biasci, J. C., Borowiec, P., Bouteille, J.-F., Brochard, T., Brookes, N. B., Carmignani, N., Carver, L., et al. (2023) · Communications Physics · doi:10.1038/s42005-023-01195-z · Cited by 174
An antimatter spectrometer in space
Ahlen, S. P., Balebanov, V. M., Battiston, R., Becker, U., Burger, J. D., Capell, M., Chen, H. F., Chen, H. S., Chen, M., Chernoplekov, N. A., et al. (1994) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(94)91184-3 · Cited by 157
Experimental results for a novel rotary active magnetic regenerator
Engelbrecht, K. L., Eriksen, D., Bahl, C. R. H., Bjørk, R., Geyti, J., Lozano, J. A., Nielsen, K. K., Saxild, F., Smith, A., & Pryds, N. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.05.003 · Cited by 155
Time-Domain NMR Applied to Food Products
van Duynhoven, J., Voda, A., Witek, M., & As, H. V. (2010) · Annual reports on NMR spectroscopy · doi:10.1016/s0066-4103(10)69003-5 · Cited by 189
Compter, J. C. (2003) · Precision Engineering · doi:10.1016/j.precisioneng.2003.08.002 · Cited by 154
“Halbach[11] produced the first publication concerning the principle of Halbach magnet-arrays and Trumper et al.”
BackgroundInjeyan, H., & Goodno, G. D. (2011) · Cited by 190
Brain imaging with portable low-field MRI
Kimberly, W. T., Sorby-Adams, A. J., WEBB, A. G., Wu, E. X., Beekman, R. B., Bowry, R., Schiff, S. J., de Havenon, A., Shen, F. X., Sze, G. K., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00086-w · Cited by 190
Blümich, B., Casanova, F., & Appelt, S. (2009) · Chemical Physics Letters · doi:10.1016/j.cplett.2009.06.096 · Cited by 176
Focused Magnetic Stem Cell Targeting to the Retina Using Superparamagnetic Iron Oxide Nanoparticles
Yanai, A., Häfeli, U. O., Metcalfe, A. L., Soema, P., Addo, L., Gregory-Evans, C. Y., Po, K., Shan, X., Moritz, O. L., & Gregory-Evans, K. (2012) · Cell Transplantation · doi:10.3727/096368911x627435 · Cited by 148
Chemical analysis by ultrahigh-resolution nuclear magnetic resonance in the Earth’s magnetic field
Appelt, S., Kühn, H., Häsing, F. W., & Blümich, B. (2006) · Nature Physics · doi:10.1038/nphys211 · Cited by 160
“are successful premagnetization techniques, but the most simple mobile and robust tool is a cylindrical Halbach magne”
MethodBlümich, B. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.07.030 · Cited by 179
Modeling and vector control of planar magnetic levitator
Kim, W., Trumper, D. L., & Lang, J. H. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.738999 · Cited by 142
Design of Sparse Halbach Magnet Arrays for Portable MRI Using a Genetic Algorithm
Cooley, C. Z., Haskell, M. W., Cauley, S., Sappo, C. R., LaPierre, C., Ha, C. G., Stockmann, J., & Wald, L. L. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2751001 · Cited by 138
“The Halbach cylinder [4]–[6] is an alternative, yoke-less permanent magnet design that offers a good balance between field strength and bore size with a small fringe field footprint,”
Helium-3 spin-echo: Principles and application to dynamics at surfaces
Jardine, A. P., Hedgeland, H., Alexandrowicz, G., Allison, W., & Ellis, J. (2009) · Progress in Surface Science · doi:10.1016/j.progsurf.2009.07.001 · Cited by 143
Magpylib: A free Python package for magnetic field computation
Ortner, M., & Bandeira, L. G. C. (2020) · SoftwareX · doi:10.1016/j.softx.2020.100466 · Cited by 158
Dipolar Halbach magnet stacks made from identically shaped permanent magnets for magnetic resonance
Soltner, H., & Blümler, P. (2010) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20165 · Cited by 133
“2 odd: 8>>>>< >>>: [3]”
Atomic nanofabrication: atomic deposition and lithography by laser and magnetic forces
Meschede, D., & Metcalf, H. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/3/202 · Cited by 154
Mobile sensor for high resolution NMR spectroscopy and imaging
Danieli, E., Jörg, M., Perlo, J., Blümich, B., & Casanova, F. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.01.022 · Cited by 125
“Among the different magnet geometries available, the cylindrical Halbach array [3] is particularly convenient because it generates a comparatively strong magnetic field at a relatively large bore size for positioning the sample.”
BackgroundA magnetic tunnel to shelter hyperpolarized fluids
Milani, J., Vuichoud, B., Bornet, A., Miéville, P., Mottier, R., Jannin, S., & Bodenhausen, G. (2015) · Review of Scientific Instruments · doi:10.1063/1.4908196 · Cited by 143
Thermomagnetically patterned micromagnets
Dumas-Bouchiat, F., Zanini, L.-F., Kustov, M., Dempsey, N. M., Гречишкин, Р. М., Hasselbach, K., Orlianges, J.-C., Champeaux, C., Catherinot, A., & Givord, D. (2010) · Applied Physics Letters · doi:10.1063/1.3341190 · Cited by 120
Halbach Permanent Magnet Shape Selection for Slotless Tubular Actuators
Meessen, K. J., Gysen, B. L. J., Paulides, J. J. H., & Lomonova, E. A. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2001536 · Cited by 115
Modeling and vector control of a planar magnetic levitator
Kim, W., Trumper, D. L., & Lang, J. H. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643048 · Cited by 113
“The linear motor uses a Halbach magnet array for its power efficiency and low field distortion [6], [7].”
BackgroundAdjustable, short focal length permanent-magnet quadrupole based electron beam final focus system
Lim, J., Frigola, P., Travish, G., Rosenzweig, J. B., Anderson, S. G., Brown, W. J., Jacob, J. S., Robbins, C. L., & Tremaine, A. M. (2005) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.8.072401 · Cited by 112
Miniature permanent magnet for table‐top NMR
Moresi, G., & Magin, R. L. (2003) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.10082 · Cited by 129
“For example, the B0 static field in the air gap for a dipole cylinder of infinite length is given by Abele (3) as By Jrln routrin [1] Bx 0 Bz 0, where rout is the external radius, rin is the internal radius and Jr the magnetic remanence of the material.”
MethodSingle-Shot MeV Transmission Electron Microscopy with Picosecond Temporal Resolution
Li, R., & Musumeci, P. (2014) · Physical Review Applied · doi:10.1103/physrevapplied.2.024003 · Cited by 121
COMPARISON OF MAGNETIC-GEARED PERMANENT-MAGNET MACHINES
Li, X., Chau, K. T., Cheng, M., & Hua, W. (2013) · Electromagnetic waves · doi:10.2528/pier12080808 · Cited by 104
“Different from radially magnetized arrangement, Halbach PM arrays hold some attractive features, namely, near-sinusoidal airgap flux density distribution, strong field intensity, and good self-shielding magnetization [35, 36].”
Li, Z., Yan, Z., Luo, J., & Yang, Z. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.060 · Cited by 101
Fawole, O., & Tabib‐Azar, M. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2761555 · Cited by 97
Design and Optimization of Neodymium-Free SPOKE-Type Motor With Segmented Wing-Shaped PM
Rahman, M. M., Kim, K., & Hur, J. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2282151 · Cited by 95
“INTRODUCTION PERMANENT magnet brushless direct current (BLDC) motors have been widely used due to their many advantages such as high torque and high efficiency [1].”
BackgroundOptimal Halbach permanent magnet designs for maximally pulling and pushing nanoparticles
Sarwar, A., Nemirovski, A. S., & Shapiro, B. (2011) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.09.008 · Cited by 100
“This is a standard assumption in the design of Halbach arrays [31], and it is true as long as the magnetic field arising from the combination of sub-magnets does not cause partial or complete demagnetization or magnetization reversals [68].”
MethodDirect Hyperpolarization of Nitrogen-15 in Aqueous Media with Parahydrogen in Reversible Exchange
Colell, J. F. P., Emondts, M., Logan, A. W. J., Shen, K., Bae, J., Shchepin, R. V., Ortiz, G. X. J., Spannring, P., Wang, Q., Malcolmson, S. J., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b00569 · Cited by 93
Magnetic particle targeting for diagnosis and therapy of lung cancers
Saadat, M., Manshadi, M. K. D., Mohammadi, M., Zare, M. J., Zarei, M., Kamali, R., & Sanati‐Nezhad, A. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.09.017 · Cited by 93
Malaria pigment crystals as magnetic micro-rotors: key for high-sensitivity diagnosis
Butykai, Á., Orbán, Á., Kocsis, V., Szaller, D., Bordács, S., Tátrai-Szekeres, E., Kiss, L. F., Bóta, A., Vértessy, B. G., Zelles, T., et al. (2013) · Scientific Reports · doi:10.1038/srep01431 · Cited by 90
Why is Inline NMR Rarely Used as Industrial Sensor? Challenges and Opportunities
Colnago, L. A., de Andrade, F. D., de Souza, A. A., Azeredo, R. B. D. V., Lima, A. A., Cerioni, L. M. C., Osán, T. M., & Pusiol, D. J. (2014) · Chemical Engineering & Technology · doi:10.1002/ceat.201300380 · Cited by 99
Thompson, M. T. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030231 · Cited by 88
“This array was first described by Mallinson in 1973 [10], [42] as a one-sided flux Bmagnetic curiosity[ and soon after discovered independently by Halbach [11], [12] for use in particle accelerators at Lawrence Livermore National Laboratory.”
MethodA Review of Magnetic Gear Technologies Used in Mechanical Power Transmission
Ruiz-Ponce, G., Arjona, M. A., Hernández, C., & Escarela-Pérez, R. (2023) · Energies · doi:10.3390/en16041721 · Cited by 85
“Halbach [88] and Choi [89] showed that this arrangement allows a strong field intensity and flux density in the air gap to be quite acceptable.”
BackgroundMagnetoelastic coupling and magnetocaloric effect in hexagonal Mn–Fe–P–Si compounds
Dung, N. H., Zhang, L., Ou, Z. Q., & Brück, E. (2012) · Scripta Materialia · doi:10.1016/j.scriptamat.2012.08.036 · Cited by 85
Shen, Y., Liu, G. Y., Xia, Z. P., & Zhu, Z. Q. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2254101 · Cited by 84
“Hence, a quasi-sinusoidal magnetization which employs segmented magnets with equal pole-arc to create a single magnet pole is proposed in [1] and analytically studied [29]–[31].”
BackgroundFast field-cycling magnetic resonance imaging
Lurie, D. J., Aime, S., Baroni, S., Booth, N. A., Broche, L., Choi, C., Davies, G. R., Ismail, S. R., Hógáin, D. Ó., & Pine, K. (2010) · Comptes Rendus Physique · doi:10.1016/j.crhy.2010.06.012 · Cited by 83
“, MA, USA) is of the Halbach design [25], being constructed of a closed “ring” of magnetised ferrite blocks, configured in such a way as to give a homogeneous, vertically-oriented magnetic field within the magnet‟s bore.”
BackgroundZhu, Z. Q., Xia, Z. P., & Howe, D. (2002) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2002.803190 · Cited by 83
Optimization and improvement of Halbach cylinder design
Bjørk, R., Bahl, C. R. H., Smith, A., & Pryds, N. (2008) · Journal of Applied Physics · doi:10.1063/1.2952537 · Cited by 81
Specular reflection of cold caesium atoms from a magnetostatic mirror
Sidorov, A. I., McLean, R., Rowlands, W. J., Lau, D., Murphy, J. E., Walkiewicz, M. R., Opat, G. I., & Hannaford, P. (1996) · Quantum and Semiclassical Optics Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/3/030 · Cited by 81
Letter of Intent for FASER: ForwArd Search ExpeRiment at the LHCPreprint
FASER Collaboration, Ariga, A., Ariga, T., Boyd, J., Casper, D. W., Feng, J. L., Galon, I., Hsu, S.-C., Kling, F., Otono, H., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.10243 · Cited by 81
“An attractive solution is to use magnets based on a Halbach array [31] constructed from permanent magnet blocks with different magnetization directions as illustrated in Fig.”
MethodMagnetostatics and micromagnetics with physics informed neural networks
Kovacs, A., Exl, L., Kornell, A., Fischbacher, J., Hovorka, M., Gusenbauer, M., Breth, L., Oezelt, H., Praetorius, D., Suess, D., et al. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168951 · Cited by 83
“The analytic solution is well-known [24].”
BackgroundMethodInfluentialMagnet arrays for synchronous machines
Trumper, D. L., Williams, M. E., & Nguyen, T. H. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1993.298897 · Cited by 79
CORDIS—an improved high-current ion source for gases
Keller, R., Nöhmayer, F., Spädtke, P., & Schönenberg, M.-H. (1984) · Vacuum · doi:10.1016/0042-207x(84)90102-7 · Cited by 78
Experimental and Theoretical Aspects of the Free-Electron Laser
Dattoli, G., & Renieri, A. (1985) · Elsevier eBooks · doi:10.1016/b978-0-444-86927-2.50005-x · Cited by 78
Tutorial: Simulating modern magnetic material systems in mumax3
Joos, J., Bassirian, P., Gypens, P., Mulkers, J., Litzius, K., Waeyenberge, B. V., & Leliaert, J. (2023) · Journal of Applied Physics · doi:10.1063/5.0160988 · Cited by 84
Scuiller, F. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2287855 · Cited by 73
“With this solution, the pole consists of several magnets of the same span that are magnetized non-radially [10], [11].”
BackgroundLi, Z., Jiang, X., Yin, P., Tang, L., Wu, H., Peng, Y., Luo, J. T., Xie, S., Pu, H., & Wang, D. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.117569 · Cited by 71
Boughrara, K., Chikouche, B. L., Ibtiouen, R., Žarko, D., & Touhami, O. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2008751 · Cited by 71
“In our analysis, the Halbach array is a particular case when the magnet arc is equal to the pole pitch.”
InfluentialRen, Z. H., Mu, W. C., & Huang, S. Y. (2018) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2018.2876679 · Cited by 71
“Compared with a Halbach magnet array, besides its compatibility to the existing RF coils, the proposed ring-pair design is easier to be fabricated and assembled to achieve a performance close to that of its counterpart with ideal magnetic polarization.”
BackgroundInfluentialAnalysis of Halbach magnet array and its application to linear motor
Lee, M. G., Lee, S. Q., & Gweon, D. (2003) · Mechatronics · doi:10.1016/s0957-4158(03)00015-1 · Cited by 70
“Halbach magnet array was proposed by Halbach in 1980 for undulator or electron wiggler [1].”
MethodA broadband single-chip transceiver for multi-nuclear NMR probes
Grisi, M., Gualco, G., & Boero, G. (2015) · Review of Scientific Instruments · doi:10.1063/1.4916206 · Cited by 80
Shen, Y., & Zhu, Z. Q. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2227147 · Cited by 70
“However, the need of torque ripple reduction by adopting Halbach magnetization [2], [3], magnet segmentation [4]–[8], pole shaping [9]–[17], and stepped magnet pole [18], [19] inevitably suffers from higher NdFeB usage or lower output torque, which in turn results in a low .”
BackgroundRavaud, R., Lemarquand, G., Lemarquand, V., & Dépollier, C. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2010623 · Cited by 70
Comparison of adjustable permanent magnetic field sources
Bjørk, R., Bahl, C. R. H., Smith, A., & Pryds, N. (2010) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2010.07.022 · Cited by 69
Vibrations powered LoRa sensor: An electromechanical energy harvester working on a real bridge
Orfei, F., Mezzetti, C. B., & Cottone, F. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808752 · Cited by 67
“We decided to use the Halbach array of permanent magnets, a special arrangement that augments the magnetic field on one side of the array while decreasing the field to near zero on the other side [3].”
MethodHigh-resolution NMR spectroscopy under the fume hood
Küster, S. K., Danieli, E., Blümich, B., & Casanova, F. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c1cp21180c · Cited by 67
Study of EDS & EMS Hybrid Suspension System With Permanent-Magnet Halbach Array
Long, Z., He, G. Y., & Xue, S. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2159237 · Cited by 67
Permanent magnet system to guide superparamagnetic particles
Baun, O., & Blümler, P. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.05.001 · Cited by 67
“p = 2 for a dipole and p = 4 for a quadrupole [27, 28].”
BackgroundMarinescu, M., & Marinescu, N. (1992) · IEEE Transactions on Magnetics · doi:10.1109/20.123952 · Cited by 67
“Abstract - A new mode of permanent magnet excitation [1,2,3, 4 ] consisting of segments magnetized nonradially, with different directions of magnetizations (see Fig.lb and IC), produces quite new solutions to the critical problems of the permanent magnet excited electrical machines.”
BackgroundRecent Development of Halbach Permanent Magnet Machines and Applications
Zhu, Z. Q. (2007) · Power Conversion Conference · doi:10.1109/pccon.2007.372911 · Cited by 66
“When a Halbach magnetised magnet is realised from discrete magnet segments [2][14-16], usually sinterred NdFeB or SmCo, Fig.”
BackgroundEvolution of the spin hall magnetoresistance in Cr2O3/Pt bilayers close to the Néel temperature
Schlitz, R., Kosub, T., Thomas, A., Fabretti, S., Nielsch, K., Makarov, D., & Goennenwein, S. T. B. (2018) · Applied Physics Letters · doi:10.1063/1.5019934 · Cited by 68
Thermal energy He3 spin-echo spectrometer for ultrahigh resolution surface dynamics measurements
Fouquet, P., Jardine, A. P., Dworski, S., Alexandrowicz, G., Allison, W., & Ellis, J. (2005) · Review of Scientific Instruments · doi:10.1063/1.1896945 · Cited by 65
Steffens, E., & Haeberli, W. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/11/r02 · Cited by 64
The ELIMED transport and dosimetry beamline for laser-driven ion beams
ROMANO, F., Schillaci, F., Cirrone, G. A. P., Cuttone, G., Scuderi, V., Allegra, L., Amato, A., Amico, A. G., Candiano, G., Luca, G. D., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.01.064 · Cited by 64
Two-color free-electron laser operation
Jaroszynski, D. A., Prazérès, R., Glotin, F., & Ortéga, J. M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.2387 · Cited by 64
Single-sided mobile NMR with a Halbach magnet
Chang, W.-H., Chen, J., & Hwang, L. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.04.005 · Cited by 63
“Several researchers have recently applied Halbach magnets [16] to build NMR magnets, for use in a tabletop NMR [17], a mobile (but not single-sided) NMR for measuring drilled rock [18,19] and prepolarizing samples in the earth-field NMR experiments [20].”
Hugon, C., D’Amico, F., Aubert, G., & Sakellariou, D. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.04.003 · Cited by 62
“Halbach, sensing the possibilities offered by rare-earth magnets, developed his famous multipole structures around these new materials [4].”
BackgroundUltracompact NMR: 1H Spectroscopy in a Subkilogram Magnet
McDowell, A. F., & Fukushima, E. (2008) · Applied Magnetic Resonance · doi:10.1007/s00723-008-0151-3 · Cited by 62
An optimized magnet for magnetic refrigeration
Bjørk, R., Bahl, C. R. H., Smith, A., Christensen, D. V., & Pryds, N. (2010) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2010.06.017 · Cited by 60
Wu, L., & Zhu, Z. Q. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2304272 · Cited by 60
“In addition to the mixed-material technique, a different pattern of magnetization directions can be utilized to PM machines, which are well-known as the Halbach PM machines [8].”
BackgroundMethodCaloric devices: A review on numerical modeling and optimization strategies
Silva, D. J., Ventura, J. O., & Araújo, J. P. (2021) · International Journal of Energy Research · doi:10.1002/er.7023 · Cited by 59
“Permanent magnets for MC refrigeration and heat pumps are based on Halbach arrays, first proposed by Halbach in 1980.(66) These arrays are special arrangements of several permanent magnets that enlarge the generated magnetic field.”
BackgroundInvestigation of Permanent Magnet Brushless Machines Having Unequal-Magnet Height Pole
Shen, Y., & Zhu, Z. Q. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2202398 · Cited by 59
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.