Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 701–800 of 1,000
Low cost undulator magnets for industrial free electron masers
Wright, C., Stuart, R. A., Lucas, J. M., & Al-Shamma’a, A. A. (2000) · Optics Communications · doi:10.1016/s0030-4018(00)01015-4 · Cited by 8
Storage of an electron plasma in a sextupole radial antihydrogen trap
Amoretti, M., Canali, C., Carraro, C., Doser, M., Lagomarsino, V., Manuzio, G., Testera, G., & Zavatarelli, S. (2006) · Physics Letters A · doi:10.1016/j.physleta.2006.07.078 · Cited by 8
Coil and Magnet Design for Nuclear Magnetic Resonance in Inhomogeneous Field
Bec, G. L., Yonnet, J.-P., & Raoof, K. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.884385 · Cited by 8
“This solution based on the Amperian currents model and on the easy-axis rotation theorem [8], [9] is for two-dimensional (2-D) systems.”
MethodStrong Permanent Magnet Dipole With Reduced Demagnetizing Effect
Li, C., & Devine, M. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2024541 · Cited by 8
“The most common and efficient design is the Halbach cylinder [1].”
BackgroundCOMPARISON OF SMCO AND NDFEB IN PM MULTIPOLES
Baltay, M., Hamann, P., Sattler, W., & Spencer, J. E. (1986) · University of North Texas Digital Library (University of North Texas) · Cited by 8
Studies on the magnetic field of a permanent magnet undulator for a free electron laser
Luccio, A. U., Mortazavi, P., & Yu, L.-H. (1984) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(84)90157-1 · Cited by 8
Ultra-low-field MRI: a David versus Goliath challenge in modern imaging
Gagliardo, C., Feraco, P., Contrino, E., D’Angelo, C., Geraci, L., Salvaggio, G., Gagliardo, A., Grutta, L. L., Midiri, M., & Marrale, M. (2025) · La radiologia medica · doi:10.1007/s11547-025-02091-y · Cited by 8
“Modern permanent magnet assemblies, particularly those employing Halbach array configurations [65], are capable of producing homogenous magnetic fields in the 0.05–0.2 Tesla range [54].”
InfluentialTomioka, K., Uchida, K., Iguchi, R., & Nagano, H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021930 · Cited by 7
Design and Optimal Control of a Multistable, Cooperative Microactuator
Olbrich, M., Schütz, A., Bechtold, T., & Ament, C. (2021) · Actuators · doi:10.3390/act10080183 · Cited by 7
“, by replacing the small ring magnet by a larger one with internally alternating magnetizations, comparable to Halbach arrays [35], or an axis-symmetric distribution of smaller magnets.”
The implementation of an easy-to-apply NMR cryoporometric instrument for porous materials
Webber, J. B. W., & Liu, H. (2023) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2023.03.006 · Cited by 7
Giesbrecht, M., Ferreira, G. T. D. C., da Silva, R. R., & Milfont, L. D. (2023) · IEEE Workshop on Power Electronics for Aerospace Applications (PEASA) · doi:10.1109/peasa58318.2023.10235384 · Cited by 8
“The magnets orientation may also differ, from the traditional north and south poles to discrete or continuous Halbach arrays [13], [16], introduced in [17].”
BackgroundSuppressing Leakage Magnetic Field in Wireless Power Transfer Using Halbach Array-Based Resonators
Honjo, Y., Caremel, C., Kawahara, Y., & Sasatani, T. (2023) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2023.3318244 · Cited by 8
“…via magnetic field can seamlessly empower various electronics, but the leakage magnetic fields generated by these systems can cause negative effects, such as tissue heating and electromagnetic interference, which pose critical limitations on the transferable power level and application scenarios [1].”
Zhou, Z., Sheng, K., Zhang, Z., Xiong, M., Li, H., & Huang, J. (2023) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.26.092402 · Cited by 7
Design, scalable construction, and test of optimal linear Halbach arrays for mobile applications
Hofmann, T., Huepfel, M., de Haas, O., & Jocher, A. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.171967 · Cited by 7
Target-field design of surface permanent magnets
Hobson, P. J., Morley, C. K., Davis, A., Smith, T. X., & Fromhold, T. M. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.034015 · Cited by 7
Kang, H., Zhou, L., Wang, J., Peng, X., & Ling, Z. (2015) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22174 · Cited by 7
Self-modification of the remanence distribution of a hollow cylindrical permanent magnet array
Xu, X. N., Lu, D., Yuan, G., Zang, W., & Jin, X. (2006) · Journal of Applied Physics · doi:10.1063/1.2234808 · Cited by 7
A non-invasive electric current sensor employing a modified shear-mode cymbal transducer
He, W., Lu, Y., Qu, C., & Peng, J. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.02.015 · Cited by 7
Soltner, H., Büscher, M., Burgmer, P., Engin, I., Nauschütt, B., Maier, S., & Glückler, H. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2535293 · Cited by 7
“Their magnetization direction pattern in the horizontal plane follows that of Halbach dipole [5] or a Mandhala [6] ring, i.”
BackgroundErgor, M., Olamat, A., Doğan, N., & Bingolbali, А. (2021) · IEEE Magnetics Letters · doi:10.1109/lmag.2021.3065643 · Cited by 8
“A magnet system generally comprises a pair of magnets or magnet blocks called Halbach magnets/rings [Halbach 1980, Raich 2004, Soltner 2010, Baun 2017].”
BackgroundInfluentialTaghavi, M., Taqavi, O., & Mirimani, S. M. (2022) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc53976.2022.9767439 · Cited by 7
Active shim coils design for Halbach magnet based on inverse boundary element method
Xu, Y., Wang, F., Wang, Y., Yu, P., Zhang, J., & Yang, X. (2022) · Magnetic Resonance Letters · doi:10.1016/j.mrl.2022.06.001 · Cited by 7
Design of a new magnetic refrigeration field source running with rotating bar-shaped magnets
Bouchekara, H. R. E. H., Kedous‐Lebouc, A., & Yonnet, J.-P. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.08.006 · Cited by 7
A Miniature Electron Spin Resonance Probehead for Transcutaneous Oxygen Monitoring
Wolfson, H., Ahmad, R., Twig, Y., Kuppusamy, P., & Blank, A. (2014) · Applied Magnetic Resonance · doi:10.1007/s00723-014-0593-8 · Cited by 7
A hand-held EPR scanner for transcutaneous oximetry
Wolfson, H., Ahmad, R., Twig, Y., Blank, A., & Kuppusamy, P. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2083864 · Cited by 7
Raptis, T. E., & Minotti, F. O. (2013) · Classical and Quantum Gravity · doi:10.1088/0264-9381/30/23/235004 · Cited by 7
Transport line for a multi-staged laser-plasma acceleration: DACTOMUS
Chancé, A., Delferrière, O., Schwindling, J., Bruni, C., Delerue, N., Specka, A., Cros, B., Maynard, G., Paradkar, B. S., & Mora, P. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.10.036 · Cited by 12
Optimization design of linear Halbach array for EDS Maglev
Jiangbo, W., Li, C., Wei, X., & Yang, B. (2008) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2008.4677556 · Cited by 7
Optimization of Permanent Magnet Assemblies Using Genetic Algorithms
Cheng, S., & Arnold, D. P. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2150203 · Cited by 7
“[9] K. Halbach, “Design of permanent multipole magnets with oriented rare earth cobalt material,” Nucl.”
BackgroundPhysical methods and techniques NMR spectroscopy
Edgar, M. A. (2012) · Annual Reports Section B (Organic Chemistry) · doi:10.1039/c2oc90013k · Cited by 9
Innovative permanent-magnet starter motors for automotive micro-hybrid applications
Labbé, N., Andreux, R., Yonnet, J.-P., Vauquelin, A., & Vilain, J.-P. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960528 · Cited by 7
“Halbach [15] invented an original way of arranging permanent magnets, claiming that their specific orientation with each other results in a greater density of magnetic energy (from a one-sided concentration effect), and shows a sine field pattern outside the array of magnets.”
BackgroundJeong, J.-H., Ryu, J., & Gweon, D. (2017) · International Conference on Mechanical and Aerospace Engineering · doi:10.1109/icmae.2017.8038620 · Cited by 7
“The stator of the magnetic levitation planar motor [3] is composed of 2-dimensional Halbach magnet array [4].”
BackgroundMagnetostatics of magnetic skyrmion crystals
Qin, R., & Wang, Y. (2018) · New Journal of Physics · doi:10.1088/1367-2630/aac9b1 · Cited by 7
Numerical calibration of a Lorentz force particle analyzer
Wang, B., & Wang, X. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aae126 · Cited by 7
Optimizing a Halbach cylinder for field homogeneity by remanence variation
Nielsen, K. K., Insinga, A. R., Bahl, C. R. H., & Bjørk, R. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.167175 · Cited by 7
Modeling and analyzing of magnetic field in unequal segmented Halbach array permanent magnet machine
Guo, L., Wang, H., Gu, X., Shi, T., & Xia, C. (2020) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-200009 · Cited by 7
Kurahashi, M. (2021) · Review of Scientific Instruments · doi:10.1063/5.0031903 · Cited by 7
Spatial Manipulation of Particles and Cells at Micro- and Nanoscale via Magnetic Forces
Panina, L. V., Gurevich, A., Beklemisheva, A. V., Omelyanchik, A. S., Levada, K. V., & Rodionova, V. V. (2022) · Vide Leaf, Hyderabad eBooks · doi:10.37247/pamolb2ed.2.22.11 · Cited by 7
Trassl, R. (2003) · Springer eBooks · doi:10.1007/978-94-017-0542-4_1 · Cited by 7
Íñiguez, J., & Raposo, V. (2009) · European Journal of Physics · doi:10.1088/0143-0807/30/2/016 · Cited by 7
Monte Carlo simulation of single-plane magnetically focused narrow proton beams
McAuley, G. A., Barnes, S. R., Slater, J. M., & Wroe, A. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/3/535 · Cited by 7
“The parameters of the magnet were chosen to mimic k = 3 (quadrapole) Halbach cylinders that are available commercially as assemblies of rare earth permanent magnetic materials (Halbach 1980) (figure 1(a)).”
BackgroundMethodDesign of Permanent Magnet Systems Using Finite Element Analysis
Jin-fang, L. I. U., Choi, H., & Walmer, M. H. (2006) · Journal of Iron and Steel Research International · doi:10.1016/s1006-706x(08)60214-9 · Cited by 7
Velocity-selected magnetic guiding of Zeeman-decelerated hydrogen atoms
Dulitz, K., & Softley, T. P. (2016) · The European Physical Journal D · doi:10.1140/epjd/e2015-60454-3 · Cited by 7
Chen, J., Zhang, B., & Ding, H. (2016) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-150113 · Cited by 7
“On the other hand, more efficient utilization can also be obtained by better arrangement of the PMs. √ The Halbach PM array, proposed in 1980 [16], can produce 2 times stronger field on one side than that of a conventional PM array with the same volume.”
A project of advanced solid-state neutron polarizer for PF1B instrument at Institut Laue-Langevin
Petukhov, A. K., Несвижевский, В. В., Bigault, T., Courtois, P., Jullien, D., & Söldner, T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5114796 · Cited by 7
A Method for Reducing Cogging Torque of Integrated Propulsion Motor
Ou, H., Hu, Y., Mao, Z., & Li, Y. (2019) · Journal of Marine Science and Engineering · doi:10.3390/jmse7070236 · Cited by 7
Verification of Loss Reduction based on New Loss Analysis for Slotless PM Motor
Shikayama, T., Takaki, M., Ohto, M., Tsuji, T., Kosaka, T., & Matsui, N. (2003) · IEEJ Transactions on Industry Applications · doi:10.1541/ieejias.123.809 · Cited by 7
Combined static potentials for confinement of neutral species
Ricci, L., Bassi, D., & Bertoldi, A. D. (2007) · Physical Review A · doi:10.1103/physreva.76.023428 · Cited by 7
Realization of a permanent magnet undulator for the CLIO infrared free electron laser at Orsay
Bourgeois, P., Carlos, P., Couprie, M.-E., Fallou, J. L., Garganne, P., Lepretre, A., Martin, J., Ortéga, J. M., & ̈re, C. C. (1991) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90749-g · Cited by 7
Magnetic fields in magnetron sputtering systems
Murphy, M. J., Cameron, D., Karim, M., & Hashmi, M. S. J. (1993) · Surface and Coatings Technology · doi:10.1016/0257-8972(93)90329-m · Cited by 7
Transmission of ultra-cold neutrons through a weakly absorbing foil
Zimmer, O. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.06.085 · Cited by 7
Abe, D. K., Kishek, R. A., Petillo, J. J., Chernin, D., & Levush, B. (2009) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2009.2015629 · Cited by 7
“On the one hand, PMQs can be used to significantly reduce magnet system weight resulting in a more than fivefold decrease compared with a PPM stack design for a comparable beam.”
MethodResultInfluentialOptimization method for permanent-magnet structures
Jensen, J. H. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.809139 · Cited by 7
“As usually an infinite number of possible arrangements of magnetic material can generate a field with a given set of properties, the determination of an optimal arrangement is often a critical design problem, which has been the subject of several studies [ 7 ]‐[12].”
ResultHigh-performance moving-coil actuators with double-sided PM arrays: A design comparison
Janssen, J. L. G., Paulides, J. J. H., Encica, L., & Lomonova, E. A. (2010) · TU/e Research Portal · Cited by 7
Kimel, I., & Elias, L. R. (1990) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(90)91276-h · Cited by 7
Scott, D. J., Appleton, S., Clarke, J. A., Malyshev, O. B., Shepherd, B. J. A., Todd, B., Baynham, D. E., Bradshaw, T. W., Brummitt, A., Carr, S., et al. (2007) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.10.032401 · Cited by 7
ADVANCED RESIDUAL GAS PROFILE MONITOR FOR HIGH CURRENT SYNCHROTRONS AND COOLER RINGS
Forck, P., Giacomini, T., Golubev, A. A., Liakin, D., Skachkov, V. S., & Vetrov, A. A. (2003) · Cited by 7
Abramovich, A., Pinhasi, Y., Yakover, Y. M., Sokolowski, J. S., & Gover, A. (1998) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)01373-9 · Cited by 7
High magnetic field gradients in flux confining permanent magnet structures
Blache, C., & Lemarquand, G. (1992) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(92)90510-u · Cited by 7
Status of the free electron laser experiment at the ENEA Frascati center
Bizzarri, U., Ciocci, F., Dattoli, G., Angelis, A. D., Fiorentino, E., Gallerano, G. P., Letardi, T., Marino, A., Messina, G., Renieri, A., et al. (1985) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(85)90351-1 · Cited by 7
Relative paleointensity estimates from magnetic anisotropy: Proof of concept
Gilder, S. A., He, K., Wack, M., & Jeẑek, J. (2019) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2019.05.003 · Cited by 6
Auler, J., Engler, M., Franz, K., Kahlenberg, J., Karch, J., Pfeifer, N., Ross, K. U., Strid, C. F., Yazdandoost, N., Adamek, E. R., et al. (2024) · Journal of Physics G Nuclear and Particle Physics · doi:10.1088/1361-6471/ad727b · Cited by 6
Stiffness characteristic of HTS pinning maglev system with electromagnetic compensation device
Lv, C., Deng, Z., Ke, Z., Li, H., Lu, Y., Zhang, P., & Ding, Z. (2025) · Journal of Applied Physics · doi:10.1063/5.0254559 · Cited by 6
Simulation and Optimization of an Octagonal Halbach Permanent Magnet Array for Small-Size NMR
Chen, Q. Y., Zhang, G. C., Xu, Y. J., Chang, Y., Wang, H., & Yang, X. D. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.543-547.509 · Cited by 6
“In 1979, Halbach proposed a novel type of permanent magnet [1-2] constructed entirely by rare earth permanent magnet material and the magnetic blocks are magnetized in different directions which are arranged in certain rules to make magnetic field lines converge on one side and weaken on the other side to obtain ideal…”
BackgroundA Method on Decreasing Magnetic Moment of Halbach Cylinder Magnets
Wang, Z., Song, T., Dong, Z., Wang, Q., & Wang, H. S. (2008) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2008.922241 · Cited by 6
“THE Halbach cylinder magnet system is a magnet ring composed of a series of oriented sub-magnets with the same shape [1], [2].”
BackgroundFiducialization of the small-aperture quadrupoles based on the vibrating wire method
Wang, B., Zheng, S., Wu, L., Du, C., Xing, Q., Wang, Z., Qiu, M., & Wang, X. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.12.025 · Cited by 6
Novel electromagnetic acoustic transducer for measuring the thickness of small specimen areas
Sun, H., Urayama, R., Hashimoto, M., Kojima, F., Uchimoto, T., & Takagi, T. (2018) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-171106 · Cited by 6
“Amplitude distribution across the lower surface of the specimen using transmitter 2. array [12,13], was used to increase the wave intensity.”
Dagusé, B., & Ayat, S. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9271019 · Cited by 6
Hu, L., Liu, M., Yang, D., Su, R., Ruan, X., Fu, X. H., & Li, Y. (2022) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062221110766 · Cited by 6
“n ×A 1⁄4 0 (37) where n is the boundary normal pointing outward.”
BackgroundJafarzadeh, S., Wulff, A. C., Engelbrecht, K. L., & Bahl, C. R. H. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202201790 · Cited by 6
Scarpa, F., Bocanegra, J. A., Fanghella, P., & Tagliafico, L. A. (2024) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2024.04.022 · Cited by 6
Yao, L. Z., Su, D., Li, X., Zhang, H.-N., & Li, F. (2024) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2024.125692 · Cited by 6
Design Considerations of High-Speed PMSM With Nonuniform Two-Segment Halbach Magnet Array
Xie, X., Liao, C., & Zhang, Z. (2024) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2024.3406872 · Cited by 6
“Among various magnetic pole configurations, The Halbach array composed of multiple discrete permanent magnet blocks with different magnetization directions [4], capable of creating a sinusoidal magnetic field, is becoming increasingly popular.”
BackgroundDevelopment of a self-assembling ferrofluidic ionic liquid mirror
Rowlands, N., Romero-Calvo, Á., Strafford, D., Kamire, R. J., Childers, A., Yates, S. F., Rahislic, E., Smoke, J., Zheng, S.-H., Cameron, P., et al. (2024) · Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation V · doi:10.1117/12.3020718 · Cited by 6
“The concept, sketched in Figure 1, explores the use of Halbach arrays, a particular arrangement of permanent magnets that produces one-sided magnetic fields [21], to manipulate ferrofluids to the desired optical shape.”
Passive Permanent Magnet Bearing for Rotating Shaft : Analytical Calculation
Lemarquand, V., & Lemarquand, G. (2010) · Sciyo eBooks · doi:10.5772/10085 · Cited by 6
Modelling of surface PM machine using soft magnetic composites and a bonded magnet ring
Tang, C., Soong, W. L., Liew, G. S., & Ertuğrul, N. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6349892 · Cited by 6
“They are in fact much closer to the field distribution from a Halbach array [14-17] (see Figures 6 and 7) which is a surprising result.”
BackgroundGuided self-assembly of magnetic beads for biomedical applications
Gusenbauer, M., Nguyen, H., Reichel, F., Exl, L., Bance, S., Fischbacher, J., Oezelt, H., Kovacs, A., Brandl, M., & Schrefl, T. (2013) · Physica B Condensed Matter · doi:10.1016/j.physb.2013.08.050 · Cited by 6
Il’yashenko, E. I., Glebov, V. A., Glebov, A. V., Skjeltorp, A. T., & Johansen, T. H. (2006) · physica status solidi (a) · doi:10.1002/pssa.200563128 · Cited by 6
Augmented Temperature Degrading Effect of Rare Earth Magnets Arranged in Segmented Halbach Arrays
Winter, O., Kral, C., & Schmidt, E. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2199850 · Cited by 6
“Halbach found another practical application for this effect: synchrotron undulators and multipoles [3].”
BackgroundHalbach-Magnet-Array-Based Focusing Actuator for Small-Form-Factor Optical Storage Device
Lee, S.-Q., Park, K.-H., Paek, M. C., & Kang, K. (2006) · Japanese Journal of Applied Physics · doi:10.1143/jjap.45.1131 · Cited by 6
Analytical Description of Two-Dimensional Magnetic Arrays Suitable for Biomedical Applications
Ilić, A. Ž., Cirkovic, S. T., Djordjevic, D. M., Luka, S. R. D., Milovanovich, I. D., Trbovich, A. M., & Ristić‐Djurović, J. L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2277831 · Cited by 6
“Array configurations using alternating magnetic axes of the neighboring elements, or magnetic axes rotated as suggested by Halbach [12], seem to be utilized more often.”
BackgroundSynthesis of magnetic systems producing field with maximal scalar characteristics
Klevets, N. I. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2004.08.010 · Cited by 6
Menon, M. C., & Asada, H. H. (2011) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2010.2102019 · Cited by 8
Marks, H. S., Volshonok, M., Dyunin, E., Gover, A., Lasser, Y., Shershevski, R., & Asher Yahalom, A. (2011) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2011.09.004 · Cited by 6
Blümich, B. (2016) · Springer eBooks · doi:10.1007/978-3-319-28275-6_75-1 · Cited by 6
Lumped circuit‐based sizing of quasi‐ Halbach PM excited T‐LSMs: application to free piston engines
Zouaghi, M. W., Abdennadher, I., & Masmoudi, A. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0299 · Cited by 6
Design of single-sided AC magnetic field generating coil for wireless power transfer
Kim, H., Hwang, K., Park, J. H., Kim, D., & Ahn, S. (2017) · IEEE Wireless Power Transfer Conference · doi:10.1109/wpt.2017.7953803 · Cited by 6
Asef, P., Perpiñá, R. B., Barzegaran, M. R., Lapthorn, A., & Mewes, D. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.08.041 · Cited by 6
Connolly, A. J., Williams, S. E., Rhode, K., Rinaldi, C. A., & Bishop, M. J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871863 · Cited by 6
“then later independently by Klaus Halbach in the 1980s [40], Fig.”
Experimental validation of magnetically focused proton beams for radiosurgery
McAuley, G. A., Teran, A. V., McGee, P. Q., Nguyen, T. T., Slater, J. M., Slater, J. D., & Wroe, A. J. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab0db1 · Cited by 6
“These magnets consist of assemblies of radiation-hard permanent magnet material arranged to produce a high quadrupole magnetic field inside a cylindrical cavity but with a low field outside (Halbach 1980).”
BackgroundMethodMagnetic field strength improvement for Lorentz actuation of a μ-Coriolis mass flow sensor
Schut, T., Klein, Y., Wiegerink, R. J., & Lötters, J. C. (2020) · Microelectronic Engineering · doi:10.1016/j.mee.2020.111236 · Cited by 6
A new room temperature LECR5 ion source for the SESRI project
Qian, C., Sun, L. T., Jia, Z. H., Li, L. B., Ma, Y. M., Fang, X., Guo, J., Wang, H., Lu, W., Zhang, X. Z., et al. (2020) · Review of Scientific Instruments · doi:10.1063/1.5128514 · Cited by 6
Bevilacqua, G., Biancalana, V., Consumi, M., Dancheva, Y. V., Rossi, C., Stiaccini, L., & Vigilante, A. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.167220 · Cited by 6
“generated by a permanent-magnet Halbach array [20].”
MRI Coils Optimized for Detection of 1H and 23Na at 0.5 T
Anisimov, N. V., Tarasova, A. A., Pavlova, O. S., Fomina, D. V., Makurenkov, A. M., Pavlovskaya, G. E., & Pirogov, Y. A. (2021) · Applied Magnetic Resonance · doi:10.1007/s00723-020-01306-x · Cited by 7
Cajzl, J., Nekvindová, P., Macková, A., Varga, M., & Kromka, A. (2022) · Physical Chemistry Chemical Physics · doi:10.1039/d2cp01803a · Cited by 6
Fernow, R. C. (2022) · Cambridge University Press eBooks · doi:10.1017/9781009291156 · Cited by 6
Natural abundant 17O NMR in a 1.5‐T Halbach magnet
Sørensen, M. K., Bakharev, O. N., Jensen, O., & Nielsen, N. C. (2015) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.4207 · Cited by 6
Identification of the ECR zone in the SWISSCASE ECR ion source
Bodendorfer, M., Altwegg, K., Wurz, P., & Shea, H. R. (2008) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2008.07.019 · Cited by 6
“for the reliable localization of the ECR process. In SWISSCASE the ring shaped magnets establish the axial connement featuring rotational symmetry with respect to the beam axis. The Halbach hexapole [13] (Figure 2) establishes the radial electron connement. The combination of the ring shaped magnets and the hexapole r…”
BackgroundChen, J., Zhang, B., Ding, Y., & Ding, H. (2016) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-150069 · Cited by 6
“To validate the proposed method, a rectangular PM of 12 mm × 12 mm is chosen as the benchmark model, where it is considered that there exists an analytical solution [11,40].”
Barnsley, L. C., Gray, M. D., Beguin, E., Carugo, D., & Stride, E. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800081 · Cited by 7
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.