Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 401–500 of 1,000
Kurahashi, M., Entani, S., & Yamauchi, Y. (2008) · Review of Scientific Instruments · doi:10.1063/1.2949385 · Cited by 19
Attainment of submillimeter periods and a 0.3-T peak field in a novel micropole undulator device
Tatchyn, R. O., & Csonka, P. L. (1987) · Applied Physics Letters · doi:10.1063/1.98204 · Cited by 19
Permanent magnet quadrupole for final focus for linear collider
lwashita, Y., Mihara, T., Antokhin, E., Kumada, М., & Aoki, M. (2004) · IEEE Bipolar/BiCMOS Circuits and Technology Meeting (BCTM) · doi:10.1109/pac.2003.1289064 · Cited by 19
ECR ion sources today Physics, performance and technology
Girard, A., & Melin, G. (1996) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(96)00405-6 · Cited by 19
Lee, S. J., & Jiles, D. C. (2000) · IEEE Transactions on Magnetics · doi:10.1109/20.908699 · Cited by 19
“The basis for the design of hollow cylindrical permanent magnet array (HCPMA) was given by the rotation theorem of Halbach [ 3 ].”
MethodOptimization of a permanent magnet undulator for free electron laser studies on the ACO storage ring
Ortéga, J. M., Bazin, C., & Deacon, D. A. G. (1983) · Journal of Applied Physics · doi:10.1063/1.332811 · Cited by 19
NMR Sensor for Onboard Ship Detection of Catalytic Fines in Marine Fuel Oils
Sørensen, M. K., Vinding, M. S., Bakharev, O. N., Nesgaard, T., Jensen, O., & Nielsen, N. C. (2014) · Analytical Chemistry · doi:10.1021/ac5014496 · Cited by 19
Yao, L. Z., Li, X., Zhang, H.-N., Chen, L., & Li, F. (2022) · Annals of Nuclear Energy · doi:10.1016/j.anucene.2022.109641 · Cited by 18
Deng, Z., Shi, H., Ke, Z., Liu, J., Li, Z., Zhang, B., Jiang, Z., Zhou, J. D., & Liu, Y. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3278946 · Cited by 18
“The onboard magnets arranged in the Halbach array, exhibiting the effect of converging the magnetic field on the one side with a concealing magnetic field on the other side [29], are attached to the suspension frame.”
BackgroundMethodJang, B., Amirshaghaghi, A., Choi, J. J., Miller, J. M., Issadore, D., Busch, T. M., Cheng, Z., & Tsourkas, A. (2025) · ACS Nano · doi:10.1021/acsnano.4c16600 · Cited by 22
Magnetic Gearing Research at NASA
Asnani, V. M., Scheidler, J. J., & Tallerico, T. (2018) · Vertical Flight Society Forum · doi:10.4050/f-0074-2018-12867 · Cited by 18
Contemporary approaches to high-field magnetic resonance imaging with large field inhomogeneity
Mullen, M., & Garwood, M. (2020) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2020.07.003 · Cited by 19
“Among the most popular designs for permanent magnet arrays is the Halbach array [16], which Blümler and others began popularizing as early as 2004 [17–19].”
BackgroundHigh homogeneity permanent magnet for diamond magnetometry
Wickenbrock, A., Zheng, H., Chatzidrosos, G., Rebeirro, J. S., Schneemann, T., & Blümler, P. (2021) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2020.106867 · Cited by 18
“Theoretically the flux inside ideal Halbach cylinders with k > 1, an inner radius Ri and an outer radius Ro is given by [1]:”
BackgroundA magnetically levitated magnetoelectric vibration generator using a Halbach array
He, W., & Qu, C. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.112301 · Cited by 18
A magnetoelectric energy harvester for low-frequency vibrations and human walking
He, W., & Liu, S. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168609 · Cited by 21
Designing a Halbach Rotor Magnetic Gear for a Marine Hydrokinetic Generator
Baninajar, H., Modaresahmadi, S., Wong, H. Y., Bird, J. Z., Williams, W. B., & Dechant, B. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3180705 · Cited by 18
“In contrast, the Halbach rotor can be designed to create a highly sinusoidal field [16], [17].”
BackgroundA portable cryostat for the cold transfer of polarized solid HD targets: HDice-I
Bass, C. D., Bade, C. M., Blecher, M., Caracappa, A., D'Angelo, A., DEUR, A., Dezern, G., Glueckler, H., Hanretty, C., Ho, D., et al. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.10.056 · Cited by 18
Design Considerations for Coreless Linear Actuators
Kremers, M. F. J., Paulides, J. J. H., Janssen, J. L. G., & Lomonova, E. A. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2246784 · Cited by 18
“The influence of the design parameters on the performance of the actuator is investigated for two magnet arrays: a vertically magnetized magnet array and a magnet array with quasi-Halbach magnetization [8].”
BackgroundGeneration of strong inhomogeneous stray fields by high-anisotropy permanent magnets
Samofalov, V. N., Ravlik, A. G., Belozorov, D. P., & Avramenko, B. A. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2004.04.122 · Cited by 18
Numerical calibration of a Lorentz force flowmeter
Wang, X., Kolesnikov, Y. B., & Thess, A. D. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/4/045005 · Cited by 18
“The flowmeter consists of a Halbach array [21] which is assembled using eight segments of NdFeB PM with special orientation of magnetization and a nozzle as shown in figure 1(a).”
MethodDevelopment of a Compact Mouse MRI Using a Yokeless Permanent Magnet
SHIRAI, T., Haishi, T., Utsuzawa, S., Matsuda, Y., & Kose, K. (2005) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.4.137 · Cited by 18
Inverted Linear Halbach Array for Separation of Magnetic Nanoparticles
Ijiri, Y., Poudel, C., Williams, P. S., Moore, L. R., Orita, T., & Zborowski, M. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2244577 · Cited by 18
Bundesmann, C., Eichhorn, C., Scholze, F., Spemann, D., Neumann, H., Pagano, D., Scaranzin, S., Scortecci, F., Leiter, H. J., Gauter, S., et al. (2016) · The European Physical Journal D · doi:10.1140/epjd/e2016-70236-0 · Cited by 19
Halbach Magnetic Circuit for Voice Coil Motor in Hard Disk Drives
Choi, Y., Ahn, D., Gweon, D., & Jeong, J. (2010) · Journal of Magnetics · doi:10.4283/jmag.2010.15.3.143 · Cited by 18
Variable strength focussing with permanent magnet quadrupoles
Gluckstern, R. L., & Holsinger, R. F. (1981) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0029-554x(81)90478-x · Cited by 18
Successful modeling, design, and test of electron cyclotron resonance ion sources
Heinen, A., Rüther, M., Ducrée, J., Leuker, J., Mrogenda, J., Ortjohann, H.-W., Reckels, E., Vitt, C., & Andrä, H. J. (1998) · Review of Scientific Instruments · doi:10.1063/1.1148667 · Cited by 18
Selected applications of planar permanent magnet multipoles in FEL insertion device design
Tatchyn, R. O. (1994) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(94)90402-2 · Cited by 18
Trapped-flux internal-dipole superconducting motor/generator
Hull, J. R., Sengupta, S., & Gaines, J. R. (1999) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.783522 · Cited by 18
“For a PM array, the magnetic field B is [8]”
BackgroundYagi, K., Onuki, H., Sugiyama, S., & Yamazaki, T. (1992) · Review of Scientific Instruments · doi:10.1063/1.1142767 · Cited by 18
Low-field NMR for polymer science
Chen, X., Li, C., Wu, L., Yan, S., Qi, L., Chen, J., & Chen, W. (2025) · Giant · doi:10.1016/j.giant.2025.100364 · Cited by 20
Automatic alignment of multiple magnets into Halbach cylinders
Chandrana, C. K., Neal, J. A., Platts, D., Morgan, B., & Nath, P. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.01.011 · Cited by 17
Seeney, C. E., Ojwang, J. O., Weiss, R. D., & Klostergaard, J. (2012) · Nanomedicine · doi:10.2217/nnm.11.183 · Cited by 17
Cogging Torque Reduction in U-Core TFPM Generator Using Different Halbach-Array Structures
Nasiri‐Zarandi, R., Ghaheri, A., & Abbaszadeh, K. (2018) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445328 · Cited by 17
“The Halbach-array was started from a magnetic curiosity of Mallinson [11] and introduced to the scientific world by Klaus Halbach in 1980 [12].”
BackgroundSchmidt, K., & Winsløw, C. (2021) · International Journal of Research in Undergraduate Mathematics Education · doi:10.1007/s40753-021-00133-0 · Cited by 17
“Case 1: Analytical Modeling of 2D Halbach Permanent Magnets The abstract APE behind this assignment is to compute and control the magnetic field induced by a so-called Halbach magnet, consisting of one or more tube shaped permanent magnets (cf. Halbach 1980 and R. Bjørk et al. 2014).”
MethodCharacteristic and Thermal Analysis of Permanent Magnet Eddy Current Brake
Li, J., Yang, G., & Sun, Q. (2021) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2021.013982 · Cited by 17
Nie, S., Ratzsch, K., Grage, S. L., Keller, J., Ulrich, A. S., Lacayo‐Pineda, J., & Wilhelm, M. (2021) · Macromolecules · doi:10.1021/acs.macromol.1c00354 · Cited by 17
Magnet array for a portable magnetic resonance imaging system
Ren, Z. H., Maréchal, L., Wan, L., Su, J., & Huang, S. Y. (2015) · IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications · doi:10.1109/imws-bio.2015.7303793 · Cited by 17
“The field homogeneity determines the bandwidth of a radiofrequency (RF) excitation.”
BackgroundA permanent magnet tubular linear generator for wave energy conversion
Yu, H., Liu, C., Yuan, B., Hu, M., Huang, L., & Zhou, S. (2012) · Journal of Applied Physics · doi:10.1063/1.3680255 · Cited by 17
Kleine Magnete für NMR‐Spektroskopie vor Ort
Danieli, E., Perlo, J., Blümich, B., & Casanova, F. (2010) · Angewandte Chemie · doi:10.1002/ange.201000221 · Cited by 18
Wang, J., Liu, S., Ban, C., Jia, Z., He, X., Ma, J., Pu, X., Li, W., & Zhi, L. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab240e · Cited by 17
Braking force characteristics of permanent magnet eddy current brake with high acceleration
Li, J., Yang, G., & Fan, Y. (2020) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-190141 · Cited by 17
“The Halbach array can enhance the air gap magnetic flux density on the working side and weaken the air gap magnetic flux density on the other side [14].”
Novel permanent magnet machines using Halbach cylinders
Zhu, Z. Q., Xia, Z. P., Atallah, K., Jewell, G. W., & Howe, D. (2002) · International Power Electronics and Motion Control Conference (IPEMC) · doi:10.1109/ipemc.2000.884630 · Cited by 17
Double helix dipole design applied to magnetic resonance: A novel NMR coil
Alonso, J., Soleilhavoup, A., Wong, A., Guiga, A., & Sakellariou, D. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.07.004 · Cited by 17
Optimization of Magnetization Directions in a 3-D Magnetic Structure
Choi, J. S., Yoo, J., Nishiwaki, S., & Izui, K. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2040251 · Cited by 17
“Thus, in the obtained optimized magnet, we observe one Halbach pattern in the plane and another Halbach pattern in the plane.”
MethodInfluentialHigh efficiency laser-assisted H− charge exchange for microsecond duration beams
Cousineau, S. M., Rakhman, A., Kay, M. J., Aleksandrov, A., Danilov, V., Gorlov, T., Liu, Y., Long, C. D., Menshov, A., Plum, M., et al. (2017) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.20.120402 · Cited by 17
“The Halbach cylindrical array configuration is chosen for the magnets [13], which does not require a heavy and bulky iron yoke for the return field.”
BackgroundExperimental study of 2-layer regenerators using Mn–Fe–Si–P materials
Christiaanse, T. V., Trevizoli, P. V., Misra, S., Carroll, C., van Asten, D., Zhang, L., Teyber, R., Govindappa, P., Niknia, I., & Rowe, A. M. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aaaba7 · Cited by 17
Nuclear Magnetic Resonance Multiphase Flowmeters: Current Status and Future Prospects
Zargar, M., Johns, M. L., Al-Jindan, J., Noui-Mehidi, M. N., & O’Neill, K. T. (2021) · SPE Production & Operations · doi:10.2118/205351-pa · Cited by 17
DISCUSSION ABOUT THE MAGNETIC FIELD PRODUCED BY CYLINDRICAL HALBACH STRUCTURES
Ravaud, R., & Lemarquand, G. (2009) · Progress In Electromagnetics Research B · doi:10.2528/pierb09012004 · Cited by 17
Double-layer quasi-Halbach guideway with NdFeB and ferrite materials for HTS Maglev
Feng, Y., Zheng, J., Deng, Z., Lei, W., & Wang, Z. (2022) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2022.167342 · Cited by 16
Gao, L., Wang, P., Yaru, G., Mohan, D., Pei, H., Jiaohong, H., Peiyu, J., Cuilan, L., Zhang, Y., Juan, C., et al. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.01.007 · Cited by 16
Identification of Liquids Encountered in Carry-On-Luggage by Mobile Nmr
Mauler, J., Danieli, E., Casanova, F., & Blümich, B. (2009) · NATO science for peace and security series. B, Physics and biophysics · doi:10.1007/978-90-481-3062-7_12 · Cited by 16
Kawato, Y., & Kim, W.-J. (2006) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2363201 · Cited by 16
A pocket sized foldable quadcopter for situational awareness and reconnaissance
Mintchev, S., & Floreano, D. (2016) · IEEE International Symposium on Safety, Security, and Rescue Robotics (SSRR) · doi:10.1109/ssrr.2016.7784333 · Cited by 16
“For stronger magnets, it is always possible to limit interferences by resorting to magnetic configurations that focus the magnetic field in specific regions [11], or to ferromagnetic elements to confine the field.”
BackgroundMagnetism in Solids: Hysteresis
Schmool, D. S., & Markó, D. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.11413-4 · Cited by 16
Zhou, Z., Fang, Y., Chen, H., Wu, Y., Du, Y., Yan, L., Tang, C., & Huang, W. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.034068 · Cited by 16
Brooks, S., Mahler, G., Cintorino, J., Tuozzolo, J., & Michnoff, R. (2020) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.23.112401 · Cited by 16
“The magnets are based on a 16-segment Halbach [4] design (Fig.”
MethodMa, Z., Chen, H., Liu, X., Xing, C., Wu, M., Wang, Y., Liu, P., Ou, Z. Q., Shen, J., Taskaev, S. V., et al. (2021) · Advanced Sustainable Systems · doi:10.1002/adsu.202000234 · Cited by 16
Fortkamp, F. P., Nakashima, A., dos Santos, V. M. A., Lozano, J. A., & Barbosa, J. R., Jr. (2023) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2023.170429 · Cited by 16
A Noncontact Magnetoelectric Generator for Energy Harvesting From Power Lines
He, W., Li, P., Wen, Y., Zhang, J., Yang, A., & Lu, C. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2323082 · Cited by 16
“A Halbach array is a magnetic structure of generating a onesided magnetic field [19], [20].”
BackgroundAnalytic construction of magnetic multipoles from cylindric permanent magnets
Frerichs, V., Kaenders, W. G., & Meschede, D. (1992) · Applied Physics A · doi:10.1007/bf00348392 · Cited by 16
Spontaneous emission of the Super-ACO fel optical klystron domino
Couprie, M.-E., Bazin, C., Billardon, M., & Velghe, M. (1989) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(89)90421-x · Cited by 16
High Temperature Superconducting Halbach Array Topology for Air-cored Electrical Machines
Zhang, H., Li, Q., Ubani, O., & Mueller, M. A. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1559/1/012140 · Cited by 15
A review of the use of simple time-domain NMR/MRI for material-science
Webber, J. B. W. (2021) · SN Applied Sciences · doi:10.1007/s42452-021-04791-2 · Cited by 15
High-dynamic-range quantum sensing of magnons and their dynamics using a superconducting qubit
Rani, S., Cao, X., Baptista, A. E., Hoffmann, A., & Pfaff, W. (2025) · Physical Review Applied · doi:10.1103/6dmm-mnxd · Cited by 17
“These effects could be addressed by a different magnet arrangement, for example in a Halbach geometry [40].”
Torque in permanent magnet couplings: Comparison of uniform and radial magnetization
Ravaud, R., Lemarquand, G., Lemarquand, V., & Dépollier, C. (2009) · Journal of Applied Physics · doi:10.1063/1.3074108 · Cited by 15
Design of a multilayer Halbach permanent magnet for human finger NMR detection
Hu, J., Yi, H., Yin, Q., Zhou, X., Lu, R., & Ni, Z. (2017) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-160101 · Cited by 15
Straka, P., & Žežulka, V. (2019) · Minerals Engineering · doi:10.1016/j.mineng.2019.105900 · Cited by 16
Size fractionation of magnetic nanoparticles by magnetic chromatography
Arlt, C., Tschöpe, A., & Franzreb, M. (2019) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2019.165967 · Cited by 15
Liu, X., Ke, Z., Chen, Y., & Deng, Z. (2022) · Superconductor Science and Technology · doi:10.1088/1361-6668/ac55f5 · Cited by 18
“The Halbach array [29] PMG could concentrate flux lines above the upper surface and achieve better levitation performance [13], which is now widely applied in Maglev transportation.”
A Novel Magnetic Circuit Design Method for a Permanent Magnetic Chuck of a Wall-Climbing Robot
Zhang, Y., Guan, E., Li, P., & Zhao, Y. (2022) · Energies · doi:10.3390/en15186653 · Cited by 15
An optimization study for the RHIC polarized jet target
Wise, T., Chapman, M. A., Haeberli, W., Kolster, H., & Quin, P. A. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.09.042 · Cited by 15
Permanent Multipole Magnets with Adjustable Strength
Halbach, K. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4336645 · Cited by 15
Self-citationNumerical simulation and its verification for an active magnetic regenerator
Kim, Y., & Jeong, S. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2010.07.003 · Cited by 15
Sierakowski, A., Kopiec, D., Majstrzyk, W., Kunicki, P., Janus, P., Dobrowolski, R., Grabiec, P., Rangelow, I. W., & Gotszalk, T. P. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/28/3/034011 · Cited by 15
Fortkamp, F. P., Lozano, J. A., & Barbosa, J. R., Jr. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.07.072 · Cited by 15
Tavares, P. F., Bengtsson, J., & Andersson, Å. (2017) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2017.09.010 · Cited by 15
Topology optimization of reduced rare-earth permanent magnet arrays with finite coercivity
Teyber, R., Trevizoli, P. V., Christiaanse, T. V., Govindappa, P., & Rowe, A. M. (2018) · Journal of Applied Physics · doi:10.1063/1.5026862 · Cited by 15
Gong, J., Huang, S. Y., Ren, Z. H., & Yu, W. (2019) · IEEE Access · doi:10.1109/access.2019.2923118 · Cited by 15
“In the literature, a cylindrical Halbach was proposed for focusing particle accelerator beams [22], [23], whereas magnet rings/ring pairs, such as those proposed by E.”
BackgroundXu, G., Lu, Z., Chen, D., Chen, L., Zhang, X. Y., Wu, X. Q., Ye, M., & Wan, B. (2020) · Nuclear Fusion · doi:10.1088/1741-4326/abcdb6 · Cited by 15
“With this algorithm, the restriction on the magnetic-dipole orientations can be relaxed, so that the so-called ‘Halbach’ arrays [11] are formed and less magnets are used than the linear method.”
MethodMagnetostatic traps for charged and neutral particles
Gomer, V., Harms, O., Haubrich, D., Schadwinkel, H., Strauch, F., Ueberholz, B., der Wiesche, S. A., & Meschede, D. (1997) · Hyperfine Interactions · doi:10.1023/a:1012621904575 · Cited by 15
Thin-Film Inductor Designs and Materials for High-Current Low-Voltage Power
Sullivan, C. R., Prabhakaran, S., Dhagat, P., & Sun, Y. (2003) · Transactions of the Magnetics Society of Japan · doi:10.3379/tmjpn2001.3.126 · Cited by 15
“A Halbach array [23] is used to provide a highly uniform magnetic field in the substrate region.”
MethodDesign aspects and status of construction of the mVINIS ion source
Efremov, A., Kutner, V. B., Bogomolov, S. L., Lebedev, A. N., Логинов, В. Н., Yazvitsky, N. Y., Dobrosavljević, A., Draganic, I. N., Dekić, S., & Stalevski, T. (1998) · Review of Scientific Instruments · doi:10.1063/1.1148568 · Cited by 15
The overview and history of permanent magnet devices in accelerator technology
Kraus, R. H. (1994) · IEEE Transactions on Magnetics · doi:10.1109/20.305560 · Cited by 15
Novel race track microtron end magnets
Новиков, Г. А., Chubarov, O. V., Halbach, K., Карев, А. И., Shvedunov, V. I., & Trower, W. P. (1998) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(97)00947-6 · Cited by 15
Self-citationDesign and control of a 6-Degree-of-Freedom levitated positioner with high precision
Hu, T. (2005) · OakTrust (Texas A&M University Libraries) · Cited by 15
Miniature and Tabletop Nuclear Magnetic Resonance Spectrometers
Blümich, B. (2016) · Wiley eBooks · doi:10.1002/9780470027318.a9458 · Cited by 17
Siebert, D. A., Branco, N. B. C., Alberton, M. D., Vitali, L., Parize, A. L., & Micke, G. A. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341566 · Cited by 14
Quantitative reaction monitoring using para hydrogen-enhanced benchtop NMR spectroscopy
Robinson, A. D., Hill-Casey, F., Duckett, S. B., & Halse, M. E. (2024) · Physical Chemistry Chemical Physics · doi:10.1039/d3cp06221j · Cited by 14
Vatani, M., Lewis, D. D., Eastham, J. F., & Ionel, D. M. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3576361 · Cited by 14
“The practical implementation of this concept using PM was later demonstrated by Halbach [146], who aimed to achieve strong, sinusoidal magnetic fields with rare-Earth cobalt PMs. Hal-bach further developed the analytical equations governing the magnetic field in such PM arrangements in [147].”
Nonuniform radiation damage in permanent magnet quadrupoles
Danly, C. R., Merrill, F. E., Barlow, D., & Mariam, F. G. (2014) · Review of Scientific Instruments · doi:10.1063/1.4892803 · Cited by 14
Heat flow control in thermo-magnetic convective systems using engineered magnetic fields
Lee, J., Nomura, T., & Dede, E. M. (2012) · Applied Physics Letters · doi:10.1063/1.4754119 · Cited by 14
Performances and design of ironless loudspeaker motor structures
Merit, B., Lemarquand, G., & Lemarquand, V. (2010) · Applied Acoustics · doi:10.1016/j.apacoust.2009.12.004 · Cited by 14
Vibration Mitigation for a Cryogen-Free Dilution Refrigerator for the AMoRE-Pilot Experiment
Lee, C., Jo, H. S., Kang, C. S., Kim, G. B., Kim, I.-W., Kim, Y. H., Lee, H. J., & So, J. H. (2018) · Journal of Low Temperature Physics · doi:10.1007/s10909-018-1991-3 · Cited by 14
Analysis of Superconducting Synchronous Motors With Halbach Array Field Excitation
Tymosch, T., Fischer, M., Ketchedjian, V., Terao, Y., & Ohsaki, H. (2020) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2020.3041314 · Cited by 14
“A Halbach array is a special arrangement of permanent magnets, which generates uniform magnetic fields and significantly increases the magnetic field on one side of the array while reducing it on the other side [7].”
BackgroundA high performance active noise control system for magnetic fields
Pyragius, T., & Jensen, K. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062650 · Cited by 19
A study on passive magnetic bearing with Halbach magnetized array
Feipeng, X., Li, T., & Liu, Y. (2008) · International Conference on Electrical Machines and Systems (ICEMS) · Cited by 14
Trassl, R., Hathiramani, P., Broetz, F., Greenwood, J. B., McCullough, R. W., Schlapp, M., & Salzborn, E. (1997) · Physica Scripta · doi:10.1088/0031-8949/1997/t73/126 · Cited by 14
Stability considerations of permanent magnet quadrupoles for CESR phase-III upgrade
Lou, W., Hartill, D. L., Rice, D. H., Rubin, D. A., & Welch, J. J. (1998) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.1.022401 · Cited by 14
Sirius—A 3 GeV Electron Storage Ring Based on Permanent Magnets
Citadini, J. F., Sanchez, P. P., Basilio, R., Rocha, M., de Siqueira, E. W., Potye, M., & Tosin, G. (2012) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2012.2185771 · Cited by 14
“Many designs of quadrupoles with PMMs have already been made [11]–[13].”
BackgroundSimulation of a low magnetic field relativistic backward wave oscillator with single mode structure
Li, X., Song, W., Tan, W., Zhang, L., Zhu, X., Hu, X., Shen, Z., Ning, Q., & Xu, L. (2016) · Physics of Plasmas · doi:10.1063/1.4942423 · Cited by 14
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.