Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 301–400 of 1,000
Design trade-offs for an active magnetic regenerator device
Fortkamp, F. P., Lang, G. B., Lozano, J. A., & Barbosa, J. R., Jr. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114467 · Cited by 26
Magnetic pressure and shape of ferrofluid seals in cylindrical structures
Ravaud, R., Lemarquand, G., & Lemarquand, V. (2009) · Journal of Applied Physics · doi:10.1063/1.3187560 · Cited by 26
Magnetomechanics of internal-dipole, Halbach-array motor/generators
Hull, J. R., & Turner, L. (2000) · IEEE Transactions on Magnetics · doi:10.1109/20.875294 · Cited by 26
“The analysis of a 2-D Halbach array can be performed by considering the magnetic field as a complex quantity with the -component as the real part and the -component as the imaginary part [ 3 ].”
BackgroundMethodInfluentialOptimal Design of a Hybrid Composite Flywheel with a Permanent Magnet Rotor
Ha, S. K., Yang, H.-I., & Kim, D.-J. (1999) · Journal of Composite Materials · doi:10.1177/002199839903301605 · Cited by 27
New structures for linear displacement sensor with high magnetic field gradient
Blache, C., & Lamarquand, G. (1992) · IEEE Transactions on Magnetics · doi:10.1109/20.179441 · Cited by 26
Halbach array motor/generators: A novel generalized electric machine
Lab., C. (. S. L. B., Merritt, B., Post, R. F., Dreifuerst, G., & Bender, D. (1995) · doi:10.2172/88777 · Cited by 26
You, Y., Guo, Y., Xiao, S., Yu, S., Ji, H., & Luo, X. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.12.077 · Cited by 25
Design of the ELIMAIA ion collection system
Schillaci, F., Cirrone, G. A. P., Cuttone, G., Maggiore, M., Andò, L., Amato, A., Costa, M., Gallo, G., Korn, G., Larosa, G., et al. (2015) · Journal of Instrumentation · doi:10.1088/1748-0221/10/12/t12001 · Cited by 25
“55 T, the Halbach formula [20] for a similar ideal quadrupole, gives a Bmax = 2 T, and, considering the differences between the present design and the ideal one, the agreement can be considered satisfactory.”
BackgroundSimpler optimized stellarators using permanent magnets
Qian, T., ZARNSTORFF, M. C., Bishop, D. N., Chambliss, A., Dominguez, A., Pagano, C., Patch, D., & Zhu, C. (2022) · Nuclear Fusion · doi:10.1088/1741-4326/ac6c99 · Cited by 25
An ultra-low cost NMR device with arbitrary pulse programming
Chen, H., Kim, Y., Nath, P., & Hilty, C. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.02.011 · Cited by 30
“Halbach cylinders [28]), the 'shim-a-ring' design reduces the need for manually aligning multiple magnets, and thereby significantly reduces the cost of a suitable magnet for NMR application.”
BackgroundThe efficiency and the demagnetization field of a general Halbach cylinder
Bjørk, R., Smith, A., & Bahl, C. R. H. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.02.034 · Cited by 25
Topology optimization for design of segmented permanent magnet arrays with ferromagnetic materials
Lee, J., Yoon, M., Nomura, T., & Dede, E. M. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.10.109 · Cited by 27
Influence of Different Halbach Arrays on Performance of Permanent Magnet Synchronous Motors
Duan, L., Lu, H., Zhao, C., & Shen, H. (2020) · IEEE International Conference on Artificial Intelligence and Computer Applications (ICAICA) · doi:10.1109/icaica50127.2020.9182625 · Cited by 25
Contactless Nanoparticle-Based Guiding of Cells by Controllable Magnetic Fields
Blümler, P., Friedrich, R. P., Pereira, J., Baun, O., Alexiou, C., & Mailänder, V. (2021) · Nanotechnology Science and Applications · doi:10.2147/nsa.s298003 · Cited by 25
“The most simple realization of this idea is illustrated in Figure 1A–C by a coaxial arrangement of two Halbach cylinders.(23) The direction of the force is simply adjusted by varying the angle between quadrupole and dipole (Figure 1C) and additionally the strength of the force can be scaled by adding another quadrupol…”
MethodA compact vibrating-sample magnetometer with variable permanent magnet flux source
Cugat, O., Byrne, R., McCaulay, J., & Coey, J. M. D. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144538 · Cited by 25
Generation of various polarization states from insertion devices: A review
Elleaume, P. (1989) · Review of Scientific Instruments · doi:10.1063/1.1140915 · Cited by 25
High flow capacity devices for anti-scale magnetic treatment of water
Gilart, F., Yero, D. R. D., Ferrer, D. I., López, P., Kindelán, G. R., & Castillo, J. (2013) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2013.04.001 · Cited by 24
Ultrasound-Induced Magnetic Imaging of Tumors Targeted by Biofunctional Magnetic Nanoparticles
Huang, K., Chieh, J.-J., Yeh, C., Liao, S.-H., Lee, Y.-Y., Hsiao, P.-Y., Wei, W.-C., Yang, H.-C., & Horng, H. E. (2017) · ACS Nano · doi:10.1021/acsnano.6b08730 · Cited by 24
Variable magnet arrays to passively shim compact permanent-yoke magnets
Überrück, T., & Blümich, B. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.11.011 · Cited by 24
Design of a stabilised flywheel unit for efficient energy storage
Šonský, J., & Tesař, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2019.100765 · Cited by 24
Operating nanoliter scale NMR microcoils in a 1tesla field
McDowell, A. F., & Adolphi, N. L. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.06.008 · Cited by 26
Design and optimization strategies for muscle-like direct-drive linear permanent-magnet motors
Ruddy, B. P., & Hunter, I. W. (2011) · The International Journal of Robotics Research · doi:10.1177/0278364911404260 · Cited by 24
Super Strong Permanent Dipole Magnet
Kumada, М., Antokhin, E., Iwashita, Y., Aoki, M., & Sugiyama, E. (2004) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2004.830555 · Cited by 24
Polarizing undulator with crossed and retarded magnetic fields
Onuki, H., Saitô, N., Saito, T., & Habu, M. (1989) · Review of Scientific Instruments · doi:10.1063/1.1140917 · Cited by 24
A Short and Light, Sparse Dipolar Halbach Magnet for MRI
Purchase, A. R., Vidarsson, L., Wachowicz, K., Liszkowski, P., Sun, H., Sarty, G. E., Sharp, J. C., & Tomanek, B. (2021) · IEEE Access · doi:10.1109/access.2021.3093530 · Cited by 24
“Each block pair magnetization was rotated by φi = 2700 + 2θi to generate a dipolar internal magnetic flux density (black arrow in Figure 1A) [43].”
MethodNguyen, V. H., & Kim, W.-J. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2170173 · Cited by 23
“The superimposed concentrated-field Halbach magnet matrix [3] was introduced in [4] and [5] and used in [6]–[8], and the study presented in this paper.”
MethodFreedman, R., Anand, V., Grant, B., Ganesan, K., Tabrizi, P., Torres, R., Catina, D., Ryan, D., Borman, C., & Krueckl, C. (2014) · Review of Scientific Instruments · doi:10.1063/1.4863857 · Cited by 23
Development of rare earth free permanent magnet generator using Halbach cylinder rotor design
Khazdozian, H., Hadimani, R. L., & Jiles, D. C. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.05.034 · Cited by 23
Halbach Effect at the Nanoscale from Chiral Spin Textures
Marioni, M. A., Penedo, M., Baćani, M., Schwenk, J., & Hug, H. J. (2018) · Nano Letters · doi:10.1021/acs.nanolett.7b04802 · Cited by 23
“This high-resolution characterization of multilayers with strong interfacial Dzyaloshinskii-Moriya interaction at scales of few 10 nm, and of predominantly one-sided localized sources of magnetic field shows a way to implement Halbach magnet arrays at the nanometer scale.”
BackgroundInfluentialPark, I., Kim, Y., & Jeong, S. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.03.012 · Cited by 23
Broetz, F., Trassl, R., McCullough, R. W., Arnold, W. R., & Salzborn, E. (2001) · Physica Scripta · doi:10.1238/physica.topical.092a00278 · Cited by 23
Mobile NMR for geophysical analysis and materials testing
Blümich, B., Jörg, M., Haber, A., Perlo, J., Danieli, E., & Casanova, F. (2009) · Petroleum Science · doi:10.1007/s12182-009-0001-4 · Cited by 24
Development of ECR ion sources in China (invited)
Zhao, H. W., Wei, B. W., Liu, Z. W., Wang, Y. F., & Zhao, W. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150337 · Cited by 23
Innovations in Crude-Oil Characterization: A Comprehensive Review of LF-NMR Applications
Khelil, I., Al-Muntaser, A. A., Varfolomeev, M. A., Hakimi, M. H., Suwaid, M. A., Saeed, S. A., Nurgaliev, D. K., Al-Fatesh, A. S., & Osman, A. I. (2024) · Energies · doi:10.3390/en17143416 · Cited by 22
Optical widefield nuclear magnetic resonance microscopy
Briegel, K. D., von Grafenstein, N. R., Draeger, J. C., Blümler, P., Allert, R. D., & Bucher, D. (2025) · Nature Communications · doi:10.1038/s41467-024-55003-5 · Cited by 22
“16) used to produce the ~84 mT bias fi eld has the layout of a Halbach dipole 39,40 .”
Analytical Optimization of Electrodynamic Suspension for Ultrahigh-Speed Ground Transportation
Hu, Y., Long, Z., Zeng, J., & Wang, Z. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3082686 · Cited by 22
Civelekoglu, O., Frazier, A. B., & Sarioglu, A. F. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010010 · Cited by 24
“[54] with magnetic elements stacked in a Halbach array format, a spatially rotating arrangement of permanent magnets that creates a strong and near-zero weak magnetic field side on two opposing faces of the arrangement [55].”
BackgroundSpatial Manipulation of Particles and Cells at Micro- and Nanoscale via Magnetic Forces
Panina, L. V., Gurevich, A., Beklemisheva, A. V., Omelyanchik, A. S., Levada, K. V., & Rodionova, V. V. (2022) · Cells · doi:10.3390/cells11060950 · Cited by 22
“A so-called Halbach magnetic system was proposed for this concept [42].”
BackgroundVatani, M., Chulaee, Y., Mohammadi, A., Stewart, D. R., Eastham, J. F., & Ionel, D. M. (2024) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec60657.2024.10598856 · Cited by 22
“3, in terms of PM dimensions and magnet-to-magnet distance can be expressed as [20]: where B r is the remanence of the PMs, ϵ = 1 , L pm is the PM length, g M 2 M is the magnet-to-magnet gap distance, n = 1 + mi , m is the number of PMs per wavelength, and τ p is the pole pitch given by: It can be…”
BackgroundJin, P., Yuan, Y. F., Lin, H., Fang, S., & Ho, S. L. (2013) · Journal of Magnetics · doi:10.4283/jmag.2013.18.2.095 · Cited by 22
Optimal design method for magnetization directions of a permanent magnet array
Choi, J. S., & Yoo, J. (2010) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2010.01.047 · Cited by 22
Comparison of Three Magnet Array-type Rotors in Surface Permanent Magnet-type Vernier Motor
Kataoka, Y., Takayama, M., Matsushima, Y., & Anazawa, Y. (2013) · Journal of international Conference on Electrical Machines and Systems · doi:10.11142/jicems.2013.2.1.1 · Cited by 22
“Generally, a repulsion-type and a Halbach-type magnet array are used to increase the magnetic flux generating at the surface of magnet [3], [4].”
BackgroundSchillaci, F., Pommarel, L. D., ROMANO, F., Cuttone, G., Costa, M., Giove, D. A., Maggiore, M., Russo, A. D., Scuderi, V., Malka, V. A., et al. (2016) · Journal of Instrumentation · doi:10.1088/1748-0221/11/07/t07005 · Cited by 22
“The PMQ system is made of four Permanent Magnet Quadrupoles, based on a hybrid Halbach design [4, 17], with a 20 mm net bore diameter.”
MethodPrzybylski, M., Sun, S., & Li, W. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/10/105015 · Cited by 22
A proposed NMR solution for multi-phase flow fluid detection
Shi, J., Deng, F., Xiao, L.-Z., Liu, H., Ma, F.-Q., Wang, M., Zhao, R., Chen, S., Zhang, J.-J., & Xiong, C. (2019) · Petroleum Science · doi:10.1007/s12182-019-00367-3 · Cited by 22
“The probe magnet had a Halbach structure (Halbach 1980; Blümler 2016), as shown in Fig.”
MethodLee, H., Han, H., & Jeon, S. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01334 · Cited by 22
Improving Magnet Designs With High and Low Field Regions
Bjørk, R., Bahl, C. R. H., Smith, A., & Pryds, N. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2114360 · Cited by 22
“where is the magnitude of the remanent flux density and is an integer [13], [14].”
BackgroundLeast Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design
Paulsen, J. L., Franck, J. M., Demas, V., & Bouchard, L. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2001697 · Cited by 22
“We first verify the present technique in the context of designing ring magnet configurations, the solution of which is the well-known Halbach dipole [27].”
BackgroundMethodInfluentialDesign of permanent-magnet field source for rotary-magnetic refrigeration systems
Lee, S. J., Kenkel, J., & Jiles, D. C. (2002) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2002.803193 · Cited by 22
Liang, T.-O., Koh, Y. H., Qiu, T., Li, E., Yu, W., & Huang, S. Y. (2022) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2022.107309 · Cited by 21
“sub-gradient rings, ∆x, was chosen within [5, 15] mm, limited by the physical confinement of the base array.”
BackgroundProposed neutron lifetime measurement using a hybrid magnetic trap for ultra-cold neutrons
Leung, K. K. H., & Zimmer, O. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.07.087 · Cited by 32
Magnetic debris mitigation system for extreme ultraviolet sources
Elg, D. T., Sporre, J. R., Curreli, D., Shchelkanov, I., Ruzic, D. N., & Umstadter, K. R. (2015) · Journal of Micro/Nanopatterning Materials and Metrology · doi:10.1117/1.jmm.14.1.013506 · Cited by 21
“a large value in a certain region and cancel each other in other regions.(13) For this application, a cylindrical Halbach array was used.”
Dipolar openable Halbach magnet design for High-Gradient Magnetic Filtration
Menzel, K., Windt, C. W., Lindner, J. A., Michel, A., & Nirschl, H. (2012) · Separation and Purification Technology · doi:10.1016/j.seppur.2012.12.019 · Cited by 21
Magnetohydrodynamic flow excited by rotating permanent magnets in an orthogonal container
Ben‐David, O., Levy, A., Mikhailovich, B., & Azulay, A. (2014) · Physics of Fluids · doi:10.1063/1.4895901 · Cited by 21
Penning traps with unitary architecture for storage of highly charged ions
Tan, J. N., Brewer, S. M., & Guise, N. D. (2012) · Review of Scientific Instruments · doi:10.1063/1.3685246 · Cited by 21
Permanent magnet spheres: Design, construction, and application (invited)
Leupold, H. A., Tilak, A. S., & Potenziani, E., II (2000) · Journal of Applied Physics · doi:10.1063/1.373141 · Cited by 21
Analysis for Ring Arranged Axial Field Halbach Permanent Magnets
Wang, H., Ye, Y., Wang, Q., Dai, Y., Yu, Y., & Weng, P. (2006) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2005.869628 · Cited by 21
“HALBACH permanent magnets (PMs) offer many attractive particular properties [1].”
BackgroundOptimal Sizing and Comparison of Permanent Magnet Thrust Bearings
Beneden, M. V., Kluyskens, V., & Dehez, B. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2625275 · Cited by 21
“Combinations of these polarizations are also possible, such as to form a perpendicular or a Halbach arrangement [11].”
BackgroundA concept for a magnetic particle imaging scanner with Halbach arrays
Bakenecker, A. C., Schumacher, J., Blümler, P., Gräfe, K., Ahlborg, M., & Buzug, T. M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab7e7e · Cited by 29
Geometric concepts for stellarator permanent magnet arrays
Hammond, K. C., Zhu, C., Brown, T., Corrigan, K., Gates, D. A., & Sibilia, M. (2020) · Nuclear Fusion · doi:10.1088/1741-4326/aba8dc · Cited by 21
“s axis. This geometric concept is, in effect, a three-dimensional generalization of the assemblies of trapezoidal magnets in Halbach cylinders employed in particle accelerators and other applications [28]. In some grid cells in concave regions of the limiting surface, in particular on the inboard side near the “beansh…”
BackgroundA robust, high-flux source of laser-cooled ytterbium atoms
Wodey, E., Rengelink, R. J., Meiners, C., Rasel, E. M., & Schlippert, D. (2021) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/abd2d1 · Cited by 27
Calculation of permanent magnet arrangements for stellarators: a linear least-squares method
Landreman, M., & Zhu, C. (2020) · Plasma Physics and Controlled Fusion · doi:10.1088/1361-6587/abd13d · Cited by 21
“Analytic solution We first derive the analytic solution by a different method than in [21] to highlight the parallels with stellarator magnet optimization.”
MethodInfluentialJanssen, J. L. G., Paulides, J. J. H., & Lomonova, E. A. (2010) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/03321641011044406 · Cited by 21
“They can be reduced by methods such as applying non-sinusoidal currents [14], skewing [15] or using quasi-Halbach topologies [16, 17].”
MethodMagnetic field optimization of permanent magnet undulators for arbitrary polarization
Bahrdt, J., Frentrup, W., Gaupp, A., Scheer, M., & Englisch, U. (2003) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2003.08.155 · Cited by 21
Cylindrical permanent-magnet structures using images in an iron shield
Peng, Q., McMurry, S., & Coey, J. M. D. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.814286 · Cited by 21
“The magnetostatic field in two dimensions is an analytic function of the complex variable [1]”
BackgroundInfluentialKang, J. H., Driscoll, H., Super, M., & Ingber, D. E. (2016) · Applied Physics Letters · doi:10.1063/1.4952612 · Cited by 21
Studies of strong magnetic field produced by permanent magnet array for magnetic refrigeration
Xu, X. N., Lu, D., Yuan, G., Han, Y. S., & Jin, X. (2004) · Journal of Applied Physics · doi:10.1063/1.1713046 · Cited by 21
Analysis of anisotropic bonded NdFeB Halbach cylinders accounting for partial powder alignment
Zhu, Z. Q., Xia, Z. P., Atallah, K., Jewell, G. W., & Howe, D. (2000) · IEEE Transactions on Magnetics · doi:10.1109/20.908903 · Cited by 21
“The amplitude of the flux density which is produced by the powder aligning system is given by [1]:”
BackgroundInternational Journal for Research in Engineering Application & Management (IJREAM)
Ijream, P. (2020) · ADVANCED SCIENCES INDEX · Cited by 21
3D-printed microfluidic manipulation device integrated with magnetic array
Wu, J., Cui, Y., Xuan, S., & Gong, X. (2018) · Microfluidics and Nanofluidics · doi:10.1007/s10404-018-2123-8 · Cited by 20
“In 1980, Klaus Halbach proposed that assembling multipole permanent magnets with different polarization angles would increase the magnetic field on one side of the array while eliminating the magnetic field on the other side (Halbach 1980).”
BackgroundNew magnet array design for downhole NMR azimuthal measurement
Luo, S., Xiao, L., Li, X., Liao, G., Liu, H., Wang, Z., Sun, Z., Liu, W., & Xu, Y. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.09.027 · Cited by 20
Viscous features of single-component melt under horizontal magneticfield
Yang, J., Bian, X., Yang, C., Bai, Y., Li, M., & Zhang, K. (2013) · Physica B Condensed Matter · doi:10.1016/j.physb.2013.01.023 · Cited by 20
Optimization shows Halbach arrays to be non-ideal for induction devices
DAVEY, K. R. (2000) · IEEE Transactions on Magnetics · doi:10.1109/20.877618 · Cited by 20
“ALBACH magnet arrays were used by Klauss Halbach in 1980 [ 1 ] for particle accelerators, but they were first introduced as a magnetic curiosity by Mallinson in 1973 [2].”
MethodVariable single-axis magnetic-field generator using permanent magnets
Tretiak, O., Blümler, P., & Bougas, L. (2019) · AIP Advances · doi:10.1063/1.5130896 · Cited by 22
Hyperpolarised 1H–13C Benchtop NMR Spectroscopy
Robinson, A. D., Richardson, P. M., & Halse, M. E. (2019) · Applied Sciences · doi:10.3390/app9061173 · Cited by 20
Optimizing magnetization orientation of permanent magnets for maximal gradient force
Kruusing, A. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(01)00267-0 · Cited by 21
Kim, M., Kim, H., & Gweon, D. (2012) · Review of Scientific Instruments · doi:10.1063/1.4764002 · Cited by 20
Optimization of systems of permanent magnets
Samofalov, V. N., Belozorov, D. P., & Ravlik, A. G. (2006) · The Physics of Metals and Metallography · doi:10.1134/s0031918x06110068 · Cited by 20
Recent Progress in High Frequency Electron Cyclotron Resonance Ion Sources
Hitz, D. (2006) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(06)44001-5 · Cited by 20
Kim, M., Jeong, J.-H., Kim, H., & Gweon, D. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/10/105022 · Cited by 20
Compact FTICR Mass Spectrometry for Real Time Monitoring of Volatile Organic Compounds
Lemaire, J., Thomas, S., Lopes, A., Louarn, E., Mestdagh, H., Latappy, H., Leprovost, J., & Héninger, M. (2018) · Sensors · doi:10.3390/s18051415 · Cited by 20
“Magnets based on a Halbach structure [21] are a very effective way to obtain a high field in the center of the bore of the magnet cylinder while having a low stray field outside.”
MethodMAGNETIC FIELD PRODUCED BY A TILE PERMANENT MAGNET WHOSE POLARIZATION IS BOTH UNIFORM AND TANGENTIAL
Ravaud, R., Lemarquand, G., Lemarquand, V., & Dépollier, C. (2009) · Progress In Electromagnetics Research B · doi:10.2528/pierb08121901 · Cited by 20
Study of permanent-magnet couplings with progressive magnetization using an analytical formulation
Charpentier, J., & Lemarquand, G. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.799069 · Cited by 20
Multi-Tesla permanent magnet field sources
Leupold, H. A., Tilak, A. S., & Potenziani, E., II (1993) · Journal of Applied Physics · doi:10.1063/1.352463 · Cited by 20
Development of HBVD-EMAT and its application in surface crack defect detection
Liu, Z., Guo, Y., Zhao, X., Cheng, J., Su, M., Zheng, K., Liu, X., & He, C. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116353 · Cited by 19
A simple and low-cost permanent magnet system for NMR
Chonlathep, K., Sakamoto, T., Sugahara, K., & Kondo, Y. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.12.010 · Cited by 22
An ultra-stable 1.5 T permanent magnet assembly for qubit experiments at cryogenic temperatures
Adambukulam, C., Sewani, V. K., Stemp, H. G., Asaad, S., Mądzik, M. T., Morello, A., & Laucht, A. (2021) · Review of Scientific Instruments · doi:10.1063/5.0055318 · Cited by 22
Towards single-cell pulsed EPR using VCO-based EPR-on-a-chip detectors
Hassan, M. A. M., Kern, M., Chu, A., Kalra, G., Shabratova, E., Tsarapkin, A., MacKinnon, N., Lips, K., Teutloff, C., Bittl, R., et al. (2022) · Frequenz · doi:10.1515/freq-2022-0096 · Cited by 19
“In his original papers, Halbach suggests that for a dipole structure eight magnets per layer structure should be suf fi cient to cancel individual magnet non-uniformities [31, 34, 35].”
BackgroundMethodStrong stray fields in systems of giant magnetic anisotropy magnets
Samofalov, V. N., Belozorov, D. P., & Ravlik, A. G. (2013) · Physics-Uspekhi · doi:10.3367/ufne.0183.201303e.0287 · Cited by 19
Optimal voice coil actuators for needle-free jet injection
Ruddy, B. P., Hunter, I. W., & Taberner, A. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944041 · Cited by 19
“Due to the linear behavior of rare earth permanent magnets [15], we can directly use a Fourier series solution of Maxwell’s equations to determine the motor performance from its dimensions.”
MethodOn the possibility of vacuum QED measurements with gravitational wave detectors
Grote, H. (2015) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.91.022002 · Cited by 19
Numerical Computation Can Save Life: FEM Simulations for the Development of Artificial Hearts
Pohlmann, A., Leßmann, M., Finocchiaro, T., Schmitz‐Rode, T., & Hameyer, K. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2082508 · Cited by 19
“First, a proof of concept is performed for various linear drive concepts, such as a Halbach array for magnetic excitation [ 5 ] or a flux concentrating concept.”
MethodHekmati, A., & Mafi, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2570206 · Cited by 19
Simple and low-cost tabletop NMR system for chemical-shift-resolution spectra measurements
Hibino, Y., Sugahara, K., Muro, Y., Tanaka, H., Sato, T., & Kondo, Y. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.07.003 · Cited by 19
Ren, Z. H., Gong, J., & Huang, S. Y. (2019) · IEEE Access · doi:10.1109/access.2019.2909834 · Cited by 19
“In [1], a sparse dipolar Halbach array [10], [11] (also named ‘‘NMR Mandhala’’ [12]) was used to supply a SEM (the main field plus the gradient field) with a quadrupolar”
MethodDiamagnetically Enhanced Electrolysis and Phase Separation in Low Gravity
Romero-Calvo, Á., Schaub, H., & Cano-Gómez, G. (2021) · Journal of Spacecraft and Rockets · doi:10.2514/1.a35021 · Cited by 19
Design and Experiments of a Novel Halbach-Cylinder-Based Magnetic Skin: A Preliminary Study
Gui, M.-J., Zhou, X.-H., Xie, X., Liu, S.-Q., Li, H., Xiang, T., Wang, J., & Hou, Z. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3147904 · Cited by 19
Development of Halbach magnet for portable NMR device
Doğan, N., Topkaya, R., Subaşi, H., Yerli, Y., & Rameev, B. Z. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/153/1/012047 · Cited by 19
Danieli, E., Berdel, K., Perlo, J., Michaeli, W., Masberg, U., Blümich, B., & Casanova, F. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.08.004 · Cited by 19
Héninger, M., Mestdagh, H., Louarn, E., Mauclaire, G., Boissel, P., Leprovost, J., Bauchard, E., Thomas, S., & Lemaire, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01107 · Cited by 19
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.