Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 801–900 of 1,000
An Analytical Subdomain Model of Torque Dense Halbach Array Motors
Mallek, M., Tang, Y., Lee, J.-C., Wassar, T., Franchek, M. A., & Pickett, J. (2018) · Energies · doi:10.3390/en11123254 · Cited by 6
“Halbach Array configurations exhibit several attractive features including a sinusoidal field distribution in air gap that results in a minimal cogging torque and a more sinusoidal back EMF waveform [12].”
BackgroundComparison of Halbach magnetized brushless motors equipped with air-cored and iron-cored rotors
Xia, Z. P., Zhu, Z. Q., Jewell, G. W., & Howe, D. (2003) · Journal of Applied Physics · doi:10.1063/1.1537706 · Cited by 6
An adjustable permanent magnet focussing system for heavy ion beams
Zeller, A., Nolen, J. A., Tanaka, S., Swanson, R., & Hay, R. D. (1988) · IEEE Transactions on Magnetics · doi:10.1109/20.11394 · Cited by 6
Rui, H., & Jian, F. X. (2012) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2012.6359136 · Cited by 6
“At present, many permanent magnet arrays have been designed to obtain the desired magnetic field distribution in the patents and papers in [2-5].”
BackgroundSinha, G. (2018) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.21.022401 · Cited by 6
“In this way, the resultant field produced by several identical magnets having different directions of magnetization can be calculated [9,20].”
BackgroundJensen, J. H., & Abele, M. G. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.799067 · Cited by 6
Mobile Nuclear Magnetic Resonance
Danieli, E., Blümich, B., & Casanova, F. (2012) · Wiley eBooks · doi:10.1002/9780470034590.emrstm1287 · Cited by 8
Wakuta, Y., Hasuyama, H., Ikenaga, S., & Yamada, K. (1987) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(87)90129-x · Cited by 6
Generation of cylindrically symmetric magnetic fields with permanent magnets and µ-metal
Ricci, L., Zimmermann, C., Vuletić, V., & Hänsch, T. W. (1994) · Applied Physics B · doi:10.1007/bf01081170 · Cited by 6
Variable-period magnetostatic undulator designs based on iron-free current configurations
Tatchyn, R. O., & Cremer, T. (1990) · IEEE Transactions on Magnetics · doi:10.1109/20.102899 · Cited by 6
Nanomaterials‐Based Magnetic Relaxation Switch Biosensors
Lowery, T. (2009) · Wiley eBooks · doi:10.1002/9783527610419.ntls0163 · Cited by 7
Field Quality and Stability of Permanent Magnet Quadrupoles
Herb, S. W. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334432 · Cited by 6
Planar permanent magnet multipoles: measurements and configurations
Cremer, T., & Tatchyn, R. O. (2002) · Particle Accelerator Conference (PAC) · doi:10.1109/pac.1995.505228 · Cited by 6
Introduction: Advances in the laser spectroscopy of solids
Yen, W. M. (1989) · Topics in applied physics · doi:10.1007/3540501541_1 · Cited by 6
Seo, S.-W., Choi, J.-Y., Hong, K., & Kim, K. (2015) · Journal of the Korean Magnetics Society · doi:10.4283/jkms.2015.25.2.058 · Cited by 5
Yuan, W., Nguyen, V. H., & Kim, W.-J. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.172318 · Cited by 5
Zhu, Z., Xiao, Y., Li, Y., Zhou, M., & Yu, D. S. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3464112 · Cited by 5
“Halbach[16]wasthefirsttoproposethe conceptofHalbachmagnetizationwhichcanproduceastronger distributionofmagneticfieldsthanconventionalunidirectional (radialandaxialintubularVCMs)magnetization.”
Determination of the Redox Ratio of Iron in a Diamagnetic Matrix Using Low-Field NMR Relaxometry
Yu, Z., Douvalis, A. P., Silva, R. D. O., Wang, Y., Pontikes, Y., & Sakellariou, D. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c02681 · Cited by 6
Analysis of Quadrupole Focusing Lattices for Electron Beam Transport in Traveling-Wave Tubes
Nichols, K. E., Carlsten, B. E., & Schamiloglu, E. (2014) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2014.2299432 · Cited by 5
The influence of grid positioning on the beam optics in the neutral beam injectors for ITER
Veltri, P., Agostinetti, P., Marcuzzi, D., Sartori, E., & Serianni, G. (2016) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2016.04.011 · Cited by 5
Ghazaly, M. M., Yahya, T. A., Amran, A. C., Abdullah, Z., Ali, M. A. M., Jamaludin, A. H., & Ali, N. M. (2016) · Jurnal Teknologi · doi:10.11113/jt.v78.9901 · Cited by 5
“The advantages of the tubular type are it can minimised the elimination of stray magnetic field and the force density delivered by the tubular type are is greater than the flat type [12-14].”
BackgroundCramer, J., Cramer, M., Demeester, E., & Kellens, K. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168637 · Cited by 5
Injection molded permanent magnets
Schliesch, T. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-88658-1.00009-1 · Cited by 5
Contributions towards variable temperature shielding for compact NMR instruments
Bornemann‐Pfeiffer, M., Meyer, K., Lademann, J., Kraume, M., & Maiwald, M. (2023) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.5379 · Cited by 5
How to overcome the demagnetization of superconducting Halbach arrays?
Houbart, M., Fagnard, J.-F., Dular, J., Dennis, A. R., Namburi, D. K., Durrell, J. H., Geuzaine, C., Vanderheyden, B., & Vanderbemden, P. (2023) · Superconductor Science and Technology · doi:10.1088/1361-6668/acf904 · Cited by 5
Optimal design of nanomagnets for on-chip field gradients
Legrand, W., Lopes, S., Schaeverbeke, Q., Montaigne, F., & Desjardins, M. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.044062 · Cited by 5
“(7)– (9) explain why the optimal distributions for maximizing a component and a gradient of the stray fields see mj rotating respectively two and three times when looping around the origin at ri [22].”
BackgroundResultInfluentialThe influence mechanism of Halbach array magnetic field control on discharge channels in EDM
Qiu, Z., Tang, J., Li, Z., Yin, M., & Peng, W. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad37af · Cited by 5
Modeling and comparison of the Halbach array with different segments per pole
Zhou, Y., Liu, G., Zhou, R., Huo, L. G., & Ming, W. (2015) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-130113 · Cited by 5
“The principle of Halbach arrays was first proposed by Halbach [1].”
BackgroundOptimal commutation laws by real-time optimization for multiple motor driven systems
Ruben, S. D., & Tsao, T. (2010) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2010.5531546 · Cited by 5
“Independently, Klaus Halbach invented the Halbach array in 1980 for use in particle acceleration [6].”
MethodTang, J., Zhang, Y., Ge, S. S., & Zhao, L. (2013) · Journal of Reinforced Plastics and Composites · doi:10.1177/0731684413480009 · Cited by 5
TetraMag: A compact magnetizing device based on eight rotating permanent magnets
Gilbert, M., Mertins, H.-C., Tesch, M. F., Berges, O., Feilbach, H., & Schneider, C. M. (2012) · Review of Scientific Instruments · doi:10.1063/1.3684877 · Cited by 5
Note: Manipulation of supersonic atomic beams with static magnetic fields
Gardner, J. R., Castillo-Garza, R., & Raizen, M. G. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4819897 · Cited by 5
Designing magnets with prescribed magnetic fields
Liu, L. (2011) · New Journal of Physics · doi:10.1088/1367-2630/13/3/033013 · Cited by 5
“Contents”
Optimal Distribution of Magnetic Material for Catheter and Guidewire Cardiology Therapies
Creighton, F. M. (2006) · IEEE International Magnetics Conference · doi:10.1109/intmag.2006.375611 · Cited by 5
Single-sided AC magnetic fields for induction heating
Avestruz, A.-T., Chang, A. H., Khushrushahi, S., Banerjee, A., & Leeb, S. B. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699954 · Cited by 5
“In doing so, cost, weight, and size are reduced, along with an improvement in mechanical robustness by not using ferrites.”
BackgroundMethodSynchrotron Radiation, Polarization, Devices and New Sources
Couprie, M.-E., & Valléau, M. (2013) · Springer proceedings in physics · doi:10.1007/978-3-319-03032-6_2 · Cited by 5
Compact MRI for Astronaut Physiological Research and Medical Diagnosis
Sarty, G. E., Kontulainen, S. A., Baxter-Jones, A. D. G., Pierson, R. A., Turek, K., Obenaus, A., Tomanek, B., Sharp, J. C., Scott, A., & Piche, L. (2012) · AIAA SPACE Conference & Exposition · doi:10.2514/6.2012-5240 · Cited by 9
Schillaci, F., Maggiore, M., Cirrone, G. A. P., Cuttone, G., Pisciotta, P., Costa, M., Rifuggiato, D., ROMANO, F., & Scuderi, V. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.08.067 · Cited by 5
Kalra, M., & Meribout, M. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2627526 · Cited by 5
“The instantaneous magnetization behavior of SPIONs M(t) of diameter D and concentration c, exposed to an external magnetic field HD(t), can be approximated by the Langevin function [9]”
BackgroundHalbach array design targeting nuclear magnetic resonance
Sonawane, S. T., & Meribout, M. (2016) · International Conference on Electronic Devices, Systems and Applications · doi:10.1109/icedsa.2016.7818513 · Cited by 5
“By using finite element method for magnetics flux density measurement, the effect of Halbach array on continuous process control NMR application’s performance of a magnetic was investigated for NMR apparatus.”
MethodTunable system for production of mirror and cusp configurations using chassis of permanent magnets
Hyde, A. R., Bushmelov, M., & Batishchev, O. V. (2017) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2017.09.011 · Cited by 5
Geometrically-differential NMR in a stripline front-end
Silva, P. F., Jouda, M., & Korvink, J. G. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106659 · Cited by 5
A stand-alone magnetic guide for producing tuneable radical beams
Miossec, C., Wu, L. Y., Bertier, P., Hejduk, M., Toscano, J., & Heazlewood, B. R. (2020) · The Journal of Chemical Physics · doi:10.1063/5.0020628 · Cited by 5
Li, Y., Hu, Y., Guo, Y. G., Song, B., & Mao, Z. (2021) · Journal of Marine Science and Engineering · doi:10.3390/jmse9030290 · Cited by 5
Optical Polarimetry for Fundamental Physics
Zavattini, G., & Valle, F. D. (2021) · Universe · doi:10.3390/universe7070252 · Cited by 5
“Although the permanent magnets were designed following the Halbach configuration [85], which in principle cancels stray fields, a small stray field of about 10 mT was present near their surface, rapidly decaying with distance.”
MethodField-Free Line Magnetic Particle Imaging Magnet Design Using Nested Halbach Cylinders
Ergor, M., & Bingolbali, А. (2022) · IEEE Magnetics Letters · doi:10.1109/lmag.2022.3159446 · Cited by 6
Physical methods and techniques: NMR spectroscopy
Edgar, M. A. (2011) · Annual Reports Section B (Organic Chemistry) · doi:10.1039/c1oc90006d · Cited by 5
Design considerations for a cycloidal mass analyzer using a focal plane array detector
Horvath, K. L., Piacentino, E. L., Serpa, R. B., Aloui, T., Vyas, R., Zhilichev, Y., von Windheim, J. A., Sartorelli, M. L., Parker, C. B., Denton, M. B., et al. (2022) · Journal of Mass Spectrometry · doi:10.1002/jms.4874 · Cited by 5
Ventilation Study of the Human Lungs by 19F MRI at 0.5 Tesla
Pavlova, O. S., Anisimov, N. V., Gulyaev, M. V., Gervits, L. L., & Pirogov, Y. A. (2022) · Applied Magnetic Resonance · doi:10.1007/s00723-022-01488-6 · Cited by 5
Sakuma, H. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.170315 · Cited by 5
Transverse Gradient Undulators and FEL operating with large energy spread
Ciocci, F., Dattoli, G., & Sabia, E. (2015) · Optics Communications · doi:10.1016/j.optcom.2015.08.053 · Cited by 5
Quasi-sheet quadrupole triplets
Skachkov, V. S., Ermakov, A. N., & Shvedunov, V. I. (2004) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2004.01.051 · Cited by 5
Lorentz-force hydrophone characterization
Grasland-Mongrain, P., Mari, J. M., Gilles, B., Poizat, A., Chapelon, J., & Lafon, C. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6722619 · Cited by 5
Pompili, R., Anania, M. P., Bellaveglia, M., Biagioni, A., Bini, S., Bisesto, F. G., Chiadroni, E., Cianchi, A., Costa, G., Giovenale, D. D., et al. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.01.071 · Cited by 7
Designing High-Accuracy Permanent Magnets for Low-Power Magnetic Resonance Imaging
Florio, F., Sinha, G., & Sundararaman, R. (2018) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2018.2795592 · Cited by 5
“rods placed symmetrically around a cylindrical bore [34],”
BackgroundDesign of an Optimally Stiff Axial Magnetic Coupling for Compliant Actuators
Gasparoto, H. F., Chocron, O., Benbouzid, M., & Meirelles, P. S. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927645 · Cited by 5
“2) Magnets magnetisation angles follow Halbach-arrays [20], [21] to direct the magnetic flux toward the air-gap using only permanent magnets for this purpose, without the need for iron yokes.”
BackgroundDesign and Analysis of Halbach Array Assisted PM Brushless DC Motor for Ceiling Fan
Shastri, S., Sharma, U., & Singh, B. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070686 · Cited by 5
“First introduced in [5], [6], these help to concentrate flux/magnetic field on one side of the array and reduce the flux on the other side as shown in Fig.”
BackgroundLee, K. C., Go, G., Yoo, A., Kang, B., Choi, E., Park, J., & Kim, C. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060593 · Cited by 5
“The magnetization direction of the concentrated field point can be controlled by appropriately arranging two or more magnets in the Halbach array, as shown in Figure 2, where the magnetic force is increased on one side and decreased to approximately zero on the opposite side [33,34].”
BackgroundResearch in the multilayer sheet guildways of Maglev
Wang, H., & Jin, N. (2003) · International Conference on Electrical Machines and Systems (ICEMS) · Cited by 5
Comparative Study of Magnetic Fields Due to Types of Planar Permanent Magnet Array
Huang, L., Huang, X., Jiang, H., & Zhou, G. (2010) · International Conference on Electrical and Control Engineering · doi:10.1109/icece.2010.844 · Cited by 5
“, it shows itself with large amplitude and more sinusoidally distributed field[1] .”
BackgroundThe Frankfurt ECRIS-RFQ facility for materials research with highly charged ions
Stiebing, K. E., Streitz, H., Schmidt, L. P. H., Schremmer, A., Bethge, Κ., Schmidt‐Böcking, H., Schempp, A., Bessler, U., Béller, P., & Madlung, J. (1996) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(95)01413-6 · Cited by 5
Permanent magnet beam transport
Holsinger, R. F. (2002) · Particle Accelerator Conference (PAC) · doi:10.1109/pac.1995.505205 · Cited by 5
High-Altitude Electromagnetic Launcher Feasibility
Knapman, J. M. (2006) · Journal of Propulsion and Power · doi:10.2514/1.16990 · Cited by 5
Design of a Permanent Magnet Wiggler for a THz Free Electron Laser
Balal, N., Magory, E., & Asher Yahalom, A. (2015) · Acta Physica Polonica A · doi:10.12693/aphyspola.128.259 · Cited by 5
Symplectic tracking through straight three dimensional fields by a method of generating functions
Titze, M., Bahrdt, J., & Wüstefeld, G. (2016) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.19.014001 · Cited by 5
“For this purpose, a pure permanent magnet Halbach-type quadrupole [21] consisting of 256 radial slices per 360 degrees is evaluated with RADIA.”
MethodGeneration of highly uniform fields with permanent magnets (invited)
Abele, M. G. (1994) · Journal of Applied Physics · doi:10.1063/1.358295 · Cited by 5
Instrumentation for the Home Builder
Pearson, R. M., & Job, C. (2007) · Encyclopedia of Magnetic Resonance · doi:10.1002/9780470034590.emrstm0242 · Cited by 5
Anisotropy effects in permanent multipole magnets
Marinescu, M., & Marinescu, N. (1984) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1984.1063430 · Cited by 5
Helical wiggler design with an array of uniform, small, permanent magnets
Diament, P. (1985) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(85)90375-4 · Cited by 5
A new proposal for generating multipole fields with permanent magnets
Qing, X. (1987) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(87)90705-4 · Cited by 5
Kimel, I., & Elias, L. R. (2005) · International Free Electron Laser Conference · doi:10.1109/fel.1989.716077 · Cited by 5
Special synchrotron radiation sources
Elleaume, P. (1988) · Synchrotron Radiation News · doi:10.1080/08940888808602518 · Cited by 5
Advanced Magnetocaloric Materials
Moreno-Ramírez, L. M., Law, J. Y., Díaz‐García, Á., & Franco, V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-819728-8.00068-1 · Cited by 8
Tunable, unmountable, permanent-magnet-based accelerator magnet
Barna, D., & Anda, G. (2025) · Physical Review Accelerators and Beams · doi:10.1103/m58n-mjcb · Cited by 4
Magnetically structured draw solutes for high-performance forward osmosis desalination
Han, H., & Jeon, S. (2025) · Desalination · doi:10.1016/j.desal.2025.119170 · Cited by 4
Chen, Z., Zhang, Y., Xiong, Y., & Wang, A. (2025) · Applied Sciences · doi:10.3390/app15095099 · Cited by 4
Encoding Magnetic Anisotropies in Digital Light Processing 3D Printing
Aïdonidis, E., Cosola, A., Bourdon, P., Dammak, H., Sangermano, M., Demoly, F., Faustini, M., Pérot, A., Lairez, D., Mouhoubi, R., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202523995 · Cited by 7
Simulations of remanence and field distributions of permanent magnet array with rectangular cavity
Xu, X. N., Lu, D., Xu, X. B., Zang, W., & Madireddi, S. C. (2008) · Journal of Applied Physics · doi:10.1063/1.2970118 · Cited by 4
Werner, M., Halbedel, B., & Rädlein, E. (2010) · Cited by 4
Müller, K., Sawatzki, S., Gauß, R., & Gutfleisch, O. (2021) · Springer eBooks · doi:10.1007/978-3-030-63101-7_29-1 · Cited by 4
Lamichhane, T. N., Charlton, T. R., Andrews, B., Malaviya, D., Pathak, A. K., Ambaye, H., Doucet, M., Lauter, V., Katsaras, J., Post, B., et al. (2021) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2020.0340 · Cited by 4
Lapchuk, A. S., Gorbov, I. V., Prygun, A. V., Balagura, I. V., & Morozov, Y. M. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00078d · Cited by 5
Acoustic blackbody through instability-induced softening
Yang, M., Qu, S., Fang, N. X., & Chen, S. (2025) · Communications Physics · doi:10.1038/s42005-025-02166-2 · Cited by 4
Investigation of Segmented Halbach Array Design for Passive Magnetorheological Brake System
Shiao, Y., & Bollepelly, M. (2025) · Applied Sciences · doi:10.3390/app15020840 · Cited by 6
Merzel, A., Bismuth, S., & Arica, Z. (2025) · Education Sciences · doi:10.3390/educsci15040397 · Cited by 4
“In one meeting, a teacher demonstrated a lesson about refrigerator magnets and the Halbach Array (Halbach, 1980), which many participants were unfamiliar with, so they learned both the science and a teaching approach.”
A More Homogeneous, Less Massive Halbach Magnet array for Portable NMR
Jizhong, C., Zhang, Y., & Chunyan, X. (2007) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi.2007.4350455 · Cited by 4
“In several years, recent advance in permanent magnetic design [1]-[7] make that the field of mobile or portable MRI / NMR devices has received increasing interest, and several important applications have been suggested and realized [8]-[15].”
BackgroundA magnetizing system for an EMA scanner-flaw detector
Gobov, Y. L., Mikhailov, A. V., & Smorodinskii, Y. G. (2014) · Russian Journal of Nondestructive Testing · doi:10.1134/s1061830914110035 · Cited by 4
“5 T in a local area within the system [6]; b, a modernized magnetizing system that is suitable for the purposes of external nondestructive testing.”
BackgroundResults of the CEA/Saclay H electron cyclotron resonance ion source, ECRIN
Tüske, O., Delferrière, O., Gobin, R., Harrault, F., & Steiner, T. (2006) · Review of Scientific Instruments · doi:10.1063/1.2163277 · Cited by 4
Analytical model of parallel magnetized magnet segments of surface PM slotless machine
Boutora, Y., Ibtiouen, R., & Takorabet, N. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350279 · Cited by 4
Mathematical modeling and design considerations for designing voice coil motor
Kim, M. H., Park, J. H., & Gweon, D. G. (2016) · International Conference on Mechanics, Materials and Structural Engineering (ICMMSE) · doi:10.2991/icmmse-16.2016.39 · Cited by 4
“This arrangement is called Halbach magnet array [4] which is invented for increasing magnet field intensity of intended direction while magnetic field of the opposite direction is weakened.”
BackgroundDevelopment of a transportable FT-ICR MS associated with a glow discharge ionization source
Vot, C. L., Bouaziz, M., Héninger, M., Boissel, P., Mauclaire, G., Mestdagh, H., Costa, F., & Lemaire, J. (2016) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.07.005 · Cited by 4
Asef, P., Perpiñá, R. B., Barzegaran, M. R., & Agarwal, T. (2017) · Electrical Engineering · doi:10.1007/s00202-017-0656-6 · Cited by 4
Advanced filter structures for NIO1 and other negative ion sources
Cavenago, M., Baltador, C., & Veltri, P. (2018) · AIP conference proceedings · doi:10.1063/1.5053332 · Cited by 4
Simulation and optimisation of homogeneous permanent magnet for portable NMR applications
Poulichet, P., Fakri, A., Delabie, C., Phuc, H. D., Cong, T. T., & Fakri‐Bouchet, L. (2014) · International Journal on Smart Sensing and Intelligent Systems · doi:10.21307/ijssis-2019-041 · Cited by 4
“Starting with the proposition of Klaus Halbac h in 1980 [3], the Halbach ring consists of segments of perma nent magnets put together in an array.”
MethodTwo-Phase Fluid Flow Experiments Monitored by NMR
Hiller, T., Hoder, G., Amann‐Hildenbrand, A., Klitzsch, N., & Schleifer, N. (2020) · E3S Web of Conferences · doi:10.1051/e3sconf/202014603005 · Cited by 4
Modeling the fringe field of permanent magnet multipoles using numerical simulations
Thuillier, T., André, T., & Méndez-Giono, J. A. (2020) · Review of Scientific Instruments · doi:10.1063/5.0008335 · Cited by 4
“d multipole, allowing to use the developed model in s imulation programs where the multipole geometry is an input parameter. I. INTRODUCTION Permanent magnets multipoles (PMM), as proposed by Halbach [1], are today widely used to focus particle beams in accelerators and to confine plasmas in ion sources. The PMM conve…”
MethodThree‐dimensional array of strong magnetic field by using cubic permanent magnets
Nishimura, K. (2020) · Electrical Engineering in Japan · doi:10.1002/eej.23294 · Cited by 4
“⃖⃖⃖⃗ dHN = dmN⃖⃖⃗ r ′ N 4πμ0rN = Br⃖⃖⃗ r ′ N 4πμ0rN dx dy (1)”
Magnetic Resonance Multi-Phase Flowmeter & Fluid Analyzer
Deng, F., Chen, G.-H., Wang, M., Xu, D., Chen, S., Zhang, X., Xiong, C., Zhang, J., Lei, Q., Shi, J., et al. (2020) · SPE Asia Pacific Oil and Gas Conference and Exhibition · doi:10.2118/202208-ms · Cited by 4
Novel Concept for Wireless Power Transfer Modules
Stillig, J., & Parspour, N. (2020) · International Conference on Broadband Communications, Wireless Sensors and Powering (BCWSP) · doi:10.1109/bcwsp50066.2020.9249465 · Cited by 4
“Based on the simplifications made before and the presented WPT module an analytical calculation of the Halbach-Array consisting of three modules is performed.”
MethodInfluentialLi, Y., & Rainer, R. (2022) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.25.040702 · Cited by 4
“In this appendix a planar Halbach type wiggler or undulator model [40] is integrated into the SLIM framework.”
Method
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.