Design of permanent multipole magnets with oriented rare earth cobalt material
Open accessThe DOI matches its Crossref record; 5 of the 6 references it cites were found in a registry or an index.
Abstract
By taking advantage of both the magnetic strength and the astounding simplicity of the magnetic properties of oriented Rare Earth Cobalt material, new designs have been developed for a number of devices.In this article on multipole magnets, special emphasis is put on quadrupoles because of their frequent use and because the achievable aperture fields (1.2-1.4T) are rather large.This paper also lays the foundation for future papers on a) linear arraysfor use as "plasma buckets" or undulators for the production of synchrotron radiation; b) structures for the production of solenoidal fields, and c) three-dimensional structures such as helical undulators or multipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The permanent magnet arranged in a Halbach fashion increases the magnetic field on one side of the array while eliminating it on the other side, which produces a high magnetic flux density gradient.32”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permanent magnets in theory and practice
McCaig, M., & Clegg, A. G. (1977) · Medical Entomology and Zoology · Cited by 131
Permanent Magnets in Theory and Practice
Carey, R. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/052 · Cited by 124
Fields and First Order Perturbation Effects in Two-Dimensional Conductor Dominated \nMagnets
Halbach, K. (1969) · eScholarship (California Digital Library) · Cited by 53
Self-citationThe effect of intrinsic magnetic properties on permanent magnet repulsion
Tsui, J., Iden, D. J., Strnat, K. J., & Evers, A. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067280 · Cited by 29
Valstyn, E. (1966) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1966.1065892 · Cited by 8
Fields and first order perturbation effects in two-dimensional conductor dominated magnets
Halbach, K. (1970) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(70)90052-2
Self-citation
Research works printed but not linked: 4
- K. J. Strnat, G. I. Hoffer: Techn. Report, AFML-TR-65-446, Wright Paterson Air Force Base, (1966); see also J. B. Y. Tsui, D. J. Iden, K. J. Strnat, A. J. Evers; IEEE Transactions on Magnetics No. 2, p 188, (1972).
- J. P. Blewett: BNL Internal Report, AADD-89, (1965).
- K. Halbach: Proc. 1979 Particle Accelerator Conference; IEEE Transactions on Nuclear Science; Vol. NS-26; p 3882, (1979).
- R. F. Holsinger, K. Halbach: Proc. 4 Intern. Workshop on Rare Earth Cobalt Permanent Magnets, p 37, (1979).
Cited by
Items 601–700 of 1,000
Adjustable Strength REC Ouadrupoles
Gluckstern, R. L., & Holsinger, R. F. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4336646 · Cited by 11
Multisegmented Magnet Array on Voice Coil Motor in Rotating Data Storage Devices
Jeong, J., Lee, M. G., Lee, J., Yoon, H.-K., & Gweon, D. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.1398 · Cited by 11
Zhou, Z., Sheng, K., Zou, J., Chen, T., & Huang, J. (2023) · Review of Scientific Instruments · doi:10.1063/5.0113662 · Cited by 10
Reduction in Leakage Magnetic Flux of Wireless Power Transfer Systems with Halbach Coils
Kusaka, K., Yamagata, K., Katsuya, J., & Sato, T. (2023) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.l23000437 · Cited by 10
Shi, H., Yang, W., Fu, S., Liu, H., Yang, J., Li, K., & Deng, Z. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3406838 · Cited by 10
“In practical applications, the greatly enhanced magnetic field tends to be generated by the Halbach arrays with obliquely magnetized PMs, such as the eight-module array with a 45 magnetization angle [19], [20], [21].”
BackgroundClosed-loop surface stress compensation with an electromagnetically actuated microcantilever
Kopiec, D., Pałetko, P., Nieradka, K., Majstrzyk, W., Kunicki, P., Sierakowski, A., Jóźwiak, G., & Gotszalk, T. P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.001 · Cited by 10
Metamaterial anisotropic flux concentrators and magnetic arrays
Bjørk, R., Smith, A., & Bahl, C. R. H. (2013) · Journal of Applied Physics · doi:10.1063/1.4816096 · Cited by 10
Current Density Reconstructions for Lorentz Force Evaluation
Mengelkamp, J., Carlstedt, M., Weise, K., Ziółkowski, M., Brauer, H., & Haueisen, J. (2016) · Research in Nondestructive Evaluation · doi:10.1080/09349847.2015.1111483 · Cited by 10
“, a Halbach array [39], is recommended.”
An open-source, low-cost NMR spectrometer operating in the mT field regime
Bryden, N. J., Antonacci, M., Kelley, M., & Branca, R. T. (2021) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2021.107076 · Cited by 10
Evaluation of single-sided nuclear magnetic resonance technology for usage in geosciences
Costabel, S., Hiller, T., Dlugosch, R., Kruschwitz, S., & Müller‐Petke, M. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac9800 · Cited by 10
“The conventional NMR measurements used a rock core analyzer based on a Halbach-array setup, which realizes an almost perfect homogeneous static magnetic field inside the sample opening (Halbach 1980, Anferova et al 2007).”
MethodSpeed-Range-Based Novel Guideway Configuration With Variable Material and Thickness for PMECB
Shi, H., Wu, S., Ke, Z., Deng, Z., & Zhang, W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3381251 · Cited by 10
Experiments with Highly-Ionized Atoms in Unitary Penning Traps
Hoogerheide, S. F., Naing, A., Dreiling, J., Brewer, S. M., Guise, N. D., & Tan, J. N. (2015) · Atoms · doi:10.3390/atoms3030367 · Cited by 12
Multi-objective design optimization of a surface-mounted modular permanent-magnet pole machine
Kasha, A. E., & Sudhoff, S. D. (2016) · IEEE Power and Energy Conference at Illinois (PECI) · doi:10.1109/peci.2016.7459229 · Cited by 10
Optimal linear generator with Halbach array for harvesting of vibration energy during human walking
Jun, J., Shin, Y., Cho, S.-J., Cho, Y.-W., Lee, S. H., & Kim, J. H. (2016) · Advances in Mechanical Engineering · doi:10.1177/1687814016649880 · Cited by 10
“The Halbach array generator consists of PMs following axial- and radial-direction PMs. One-sided magnetic flux was introduced by Mallinson,7 and the Halbach array was developed by Halbach.8 In case of the Halbach array shown in Figure 3, if the axial and radial PMs were magnetized alternatively, magnetic flux is conce…”
MethodDesign and implementation of electron diverters for lobster eye space-based X-ray optics
Aslanyan, V., Keresztes, K., Feldman, C., Pearson, J. F., Willingale, R., Martindale, A., Sembay, S. F., Osborne, J. P., Sachdev, S. S., Bicknell, C. D., et al. (2019) · Review of Scientific Instruments · doi:10.1063/1.5120410 · Cited by 10
Hart, S., Hart, K., & Selvaggi, J. P. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2020.2992191 · Cited by 10
“There are other more elaborate methods employed for concentrating the magnetic flux, such as those used in various Halbach [2]–[8] permanent magnet designs.”
MethodSronsri, C., Sittipol, W., & U-yen, K. (2022) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2022.104460 · Cited by 12
Effects of magnetic field on the viscosity of molten Cu–Sn alloys
Mao, T., Bian, X., Morioka, S., Wu, Y., Li, X., & Lv, X. (2007) · Physics Letters A · doi:10.1016/j.physleta.2007.02.018 · Cited by 10
Torque in nested Halbach cylinders
Mhı́ocháin, T. R. N., Coey, J. M. D., Weaire, D. L., & McMurry, S. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.800724 · Cited by 10
Concepts and designs of life support systems
Leßmann, M., Finocchiaro, T., Steinseifer, U., Schmitz‐Rode, T., & Hameyer, K. (2008) · IET Science Measurement & Technology · doi:10.1049/iet-smt:20080083 · Cited by 10
Putting Therapeutic Nanoparticles Where They Need to Go by Magnet Systems Design and Control
Komaee, A., Lee, R., Nacev, A., Probst, R., Sarwar, A., Depireux, D. A., Dormer, K. J., Rutel, I. B., & Shapiro, B. (2012) · CRC Press eBooks · doi:10.1201/b11760-22 · Cited by 10
Octagonal Halbach Magnet Array Design for a Magnetic Refrigerator
Celik, S., & Kural, M. H. (2017) · Heat Transfer Engineering · doi:10.1080/01457632.2017.1305846 · Cited by 10
Spin-hall-active platinum thin films grown via atomic layer deposition
Schlitz, R., Amusan, A. A., Lammel, M., Schlicht, S., Tynell, T., Bachmann, J., Woltersdorf, G., Nielsch, K., Goennenwein, S. T. B., & Thomas, A. (2018) · Applied Physics Letters · doi:10.1063/1.5025472 · Cited by 11
Prando, L. T., Melchiors, M. D. S., Torres, T. M. S., de Oliveira, V. A., Veneral, J. G., Castiani, M. A., de Olíveira, D., de Oliveira, J. V., & Luccio, M. D. (2018) · Catalysis Communications · doi:10.1016/j.catcom.2018.08.006 · Cited by 10
Elastic Magnetic Membrane for Improved Mixing in Microwells
Chong, Z. Z., Sim, W. J., Yeo, Z. T., Li, K. H. H., Ng, S. H., Xia, H., Wong, T. N., Loh, N. H., Tor, S. B., Tan, S. H., et al. (2014) · Micro and Nanosystems · doi:10.2174/1876402907666150211232432 · Cited by 10
“Since the ferrite particles were magnetized using a rotating magnetic field during the manufacturing process, the particles are arranged in a Halbach array [20, 21].”
MethodA polarized hydrogen/deuterium atomic beam source for internal target experiments
Szczerba, D., van Buuren, L. D., van den Brand, J. F. J., Bulten, H. J., Ferro-Luzzi, M., Klous, S., Kolster, H., Lang, J., Mul, F., Poolman, H. R., et al. (2000) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(00)00548-9 · Cited by 10
Design and control of a 6-DOF high-precision integrated positioner
Kim, W.-J., Hu, T., & Bhat, N. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383839 · Cited by 10
Periodic magnets for undulators and free electron lasers--A review of performance features
Poole, M. W., & Walker, R. P. (1981) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1981.1061281 · Cited by 10
Pimazzoni, A., Sartori, E., & Serianni, G. (2021) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2021.112693 · Cited by 9
Forbes, M., Robertson, W. S. P., Zander, A. C., & Paulides, J. J. H. (2024) · Advanced Physics Research · doi:10.1002/apxr.202300136 · Cited by 9
Analytic approach to creating homogeneous fields with finite-size magnets
Rehberg, I., & Blümler, P. (2025) · Physical Review Applied · doi:10.1103/9nnk-jytn · Cited by 9
“Applying the concept of one-sided fluxes [8], Klaus Hal-bach [9] has presented a perfect solution to this challenge which is illustrated in Fig.”
3-D Analytical Model of Axial-Flux Permanent Magnet Machine With Segmented Multipole-Halbach Array
Okita, T., & Harada, H. (2023) · IEEE Access · doi:10.1109/access.2022.3233922 · Cited by 9
“In order to generate high torque in electric machines, a Halbach PM array has so far been suggested and studied in various areas by many researchers [18], [19], [20], [21], [22], [23], [24].”
BackgroundIntense continuous cold-atom source
Huntington, W., Glick, J., Borysow, M., & Heinzen, D. J. (2023) · Physical Review A · doi:10.1103/physreva.107.013302 · Cited by 12
“Our atom lens contains a cylindrical Hallbach array of neodymium (NdFeB) permanent magnets [28, 48].”
BackgroundA do-it-yourself approach for developing a magnetic field mapping setup using a 3D printer
Omelyanchik, A. S., Marqués, J. L., Rivas, M., Rodionova, V. V., Canepa, F., & Peddis, D. (2023) · Measurement Science and Technology · doi:10.1088/1361-6501/acde9b · Cited by 10
Polynomial inclusions: Definitions, applications, and open problems
Yuan, T., & Liu, L. (2023) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2023.105440 · Cited by 9
Zhou, F., Yang, J., & Jia, L. (2023) · IEEE Access · doi:10.1109/access.2023.3323596 · Cited by 9
“In 1979, the introduction of the Halbach [5], [6] array has further advanced the development of the permanent magnetic levitation technology, making it widely used in the field of magnetic levitation transportation [7].”
BackgroundThalmayer, A. S., Götz, K., & Fischer, G. (2024) · Symmetry · doi:10.3390/sym16020148 · Cited by 12
Gogo, T., & Zhu, D. (2024) · IET Microwaves Antennas & Propagation · doi:10.1049/mia2.12460 · Cited by 9
Development of a field free line magnet for projection MPI
Konkle, J., Goodwill, P. W., & Conolly, S. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.878435 · Cited by 11
Use of Permanent Magnets in multiple projects at CERN
Thonet, P. A. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2532361 · Cited by 9
“magnet quadrupole) based on a Halbach array [4], [5].”
MethodSchlitz, R., Helm, T., Lammel, M., Nielsch, K., Erbe, A., & Goennenwein, S. T. B. (2019) · Applied Physics Letters · doi:10.1063/1.5090209 · Cited by 9
Modeling of Magnetorheological Elastomers Using the Elastic–Plastic Model with Kinematic Hardening
Lewandowski, D. (2019) · Materials · doi:10.3390/ma12060892 · Cited by 9
“The magnetic field was generated using the so-called Halbach matrix constructed using a system of permanent magnets [21].”
MethodDesign, development and characterization of tunable Permanent Magnet Quadrupole for Drift Tube Linac
Teotia, V., Malhotra, S., Mishra, E., & Kumar, P. (2020) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2020.164528 · Cited by 9
A 3-D Printed Halbach-Cylinder Motor With Self-Position Sensing for Precision Motions
Yuan, W., Nguyen, V. H., & Kim, W.-J. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3087523 · Cited by 9
Holsaeter, A. M., Ambrus, A., Cayeux, E., Mihai, R. G., & Moi, S. (2023) · SPE/IADC Drilling Conference · doi:10.2118/212521-ms · Cited by 9
Mathew, J. V., Rao, S. V. L. S., Krishnagopal, S., & Singh, P. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.05.142 · Cited by 9
Dubois, M. R., & Mailloux, G. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.918920 · Cited by 9
Phase combination for self-cancellation of magnetic force in undulators
Kinjo, R., & Tanaka, T. (2014) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.17.122401 · Cited by 9
A novel NMR instrument for real time drilling fluid analysis
Li, S., Xiao, L., Li, X., & Wang, Z. (2017) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2017.08.038 · Cited by 9
Landry, D. M. W., Kim, W., Amsden, J. J., Dona, S. T. D., Choi, H., Haley, L., Russell, Z. E., Parker, C. B., Glass, J. T., & Gehm, M. E. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1827-4 · Cited by 9
Halbach undulators using right triangular magnets
Majernik, N., & Rosenzweig, J. B. (2019) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.22.092401 · Cited by 9
Nanomechanical Infrared Spectroscopy with Vibrating Filters for Pharmaceutical Analysis
Kurek, M., Carnoy, M., Larsen, P. E., Nielsen, L. H., Hansen, O., Rades, T., Schmid, S., & Boisen, A. (2017) · Angewandte Chemie · doi:10.1002/ange.201700052 · Cited by 9
MAGNETIC SYSTEM FOR CLEANING THE GAMMA BEAM AT THE LUE-40 ELECTRON LINAC OUTPUT
Mytrochenko, V., Perezhogin, S. O., Selivanov, L. I., Zhyglo, V. P., Водин, А. Н., Deiev, O. S., Olejnik, S. M., Timchenko, I. S., & Kushnir, V. A. (2022) · doi:10.46813/2022-139-062 · Cited by 9
Optimization design of linear Halbach array
Wang, J., Li, C., Li, Y., & Yan, L. (2008) · International Conference on Electrical Machines and Systems (ICEMS) · Cited by 9
Design of a “two-ion source” Charge Breeder using ECR ion source in two frequency mode
Naik, D., Naik, V., Chakrabarti, A., Dechoudhury, S., Nayak, S., Pandey, H. K., & Nakagawa, T. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.03.139 · Cited by 9
Tests of planar permanent magnet multipole focusing elements
Cobb, J. K., & Tatchyn, R. O. (1994) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(94)91948-8 · Cited by 9
A Flexible Planar/Helical Undulator Design for Synchrotron Sources
Elleaume, P. (1990) · Physica Scripta · doi:10.1088/0031-8949/1990/t31/009 · Cited by 9
A modified permanent magnet structure for a stronger multipole magnetic field
Koivisto, H., Suominen, P., Tarvainen, O., & Hitz, D. (2004) · Review of Scientific Instruments · doi:10.1063/1.1690445 · Cited by 9
Planar permanent magnet multipoles for particle accelerator and storage ring applications
Tatchyn, R. O. (1994) · IEEE Transactions on Magnetics · doi:10.1109/20.334295 · Cited by 9
First operation of the Israeli Tandem Electrostatic Accelerator Free-Electron Laser
Abramovich, A., Arensburg, A., Chairman, D., Eichenbaum, A. L., Draznin, M., Gover, A., Kleinman, H., Merhasin, I. M., Pinhasi, Y., Sokolowski, J. S., et al. (1998) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)01358-2 · Cited by 9
Design, construction and NMR testing of a 1 tesla Halbach Permanent Magnet for Magnetic Resonance
Zhang, X., Mahesh, V., Ng, D., Hubbard, R. T., Ailiani, A. C., Benesi, A. J., & WEBB, A. G. (2005) · Cited by 9
Couprie, M.-E., Bazin, C., & Billardon, M. (1989) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(89)91204-7 · Cited by 9
The U.k. Free Electron Laser Project
Poole, M. W., Saxon, G., Walker, R. P., Snith, S. D., Pidgeon, C. R., Firth, W. J., Reid, J. M., Kelliher, M. G., & Gillespie, W. A. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4336579 · Cited by 9
A permanent magnet for whole-body NMR imaging
Battocletti, J. H., & Knox, T. A. (1985) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1985.1063979 · Cited by 9
Lindenfels, J. V., Posch, D., Ihne, T., Franke, J. E., & Kühl, A. (2023) · Procedia CIRP · doi:10.1016/j.procir.2023.09.114 · Cited by 8
Halbach structure parameter optimization by Maxwell tensor method for PML in manned hybrid maglev
Sun, R., Zheng, J., Li, H., Xiang, S., & Jiang, W. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.172566 · Cited by 8
Fighting the climate crisis with caloric heat pumping: Innovations to enable widespread adoption
Czernuszewicz, A., Cui, J., Johnson, D. D., Griffith, L. D., Mudryk, Y., & Slaughter, J. (2024) · MRS Energy & Sustainability · doi:10.1557/s43581-024-00121-2 · Cited by 8
“…power density and reduce cost associated with field-producing components, elimi - nating hefty and expensive drivers, such as hydraulic actuators needed to provide large stresses for elastocaloric and barocaloric materials 53 or bulky, complex magnet configurations 73 for mag-netocaloric materials.”
Baninajar, H., Bird, J. Z., Modaresahmadi, S., & Williams, W. B. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8911901 · Cited by 8
“,ro6-l5-17] Cage bar length, l5 [8,9,10,11,12] outer radius, ro6 [55,60,65,70] Axial length, d 60”
BackgroundFinal focus system for injection into a laser plasma accelerator
Yamin, S., Assmann, R. W., Burkart, F., Pousa, Á. F., Lemery, F., Panofski, E., Hillert, W., & Marchetti, B. (2021) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.24.091602 · Cited by 8
“A promising option for fulfilling these requirements is the use of a Halbach-type permanent magnetic quadrupole (PMQ) triplet [28].”
MethodZhao, X., Du, Y., Zhang, R., Guo, K., & Wang, H. (2022) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems56177.2022.9983269 · Cited by 8
Dual magnet solenoid actuator: Practical applications
Bae, S. J., Lee, S. J., Joo, M. G., & Im, D. J. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114893 · Cited by 8
A parametric and comparative study of a permanent magnet structure
de Souza, A. C., Imamura, W., Kaneko, G. H., Bouchonneau, N., da Costa, J. Â. P., Leite, G. N. P., & Ochoa, Á. A. V. (2024) · Applied Physics A · doi:10.1007/s00339-024-07361-6 · Cited by 8
“The Halbach cylinder [8] is a very common array of permanent magnet used in MRS.”
A Novel Two-Stage 3D-Printed Halbach Array-Based Device for Magneto-Mechanical Applications
Makridis, A., Μaniotis, Ν., Papadopoulos, D., Kyriazopoulos, P., & Angelakeris, M. (2024) · Magnetochemistry · doi:10.3390/magnetochemistry10040021 · Cited by 11
Deng, Z., Shi, H., Chen, Y., Ke, Z., Liang, L., Liu, X., Li, K., & Zhang, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115618 · Cited by 8
A new linear voice-coil motor for ironless loudspeakers: Analytical study
Lemarquand, V., Ravaud, R., & Lemarquand, G. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5608178 · Cited by 8
A size-adjustable radiofrequency coil for investigating plants in a Halbach magnet
Oligschläger, D., Rehorn, C., Lehmkuhl, S., Adams, M. L., Adams, A., & Blümich, B. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.03.010 · Cited by 8
Design of a Hyperconducting Synchronous Machine for High-Torque Applications
Filusch, D., Breiteneder, M., & Herzog, H. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506697 · Cited by 8
“[12] K. Halbach, “Design of permanent multipole magnets with oriented rare earth cobalt material,” Nuclear Instruments and Methods, vol. 169, no. 1, pp. 1–10, 1980.”
BackgroundInfluentialDesign and assembling of a magnetic circuit for a thermomagnetic motor apparatus
Kaneko, G. H., Souza, A. C., Moro, F., Colman, F. C., Conceição, W. A. S., Alves, C. S., & Trevizoli, P. V. (2019) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-019-1898-1 · Cited by 8
Table-top nuclear magnetic resonance system for high-pressure studies with in situ laser heating
Meier, T., Dwivedi, A., Khandarkhaeva, S., Fedotenko, T., Dubrovinskaia, N., & Dubrovinsky, L. (2019) · Review of Scientific Instruments · doi:10.1063/1.5128592 · Cited by 8
A synthetic macroscopic magnetic unipole
Markoulakis, E., Chatzakis, J., Konstantaras, A., & Antonidakis, E. (2020) · Physica Scripta · doi:10.1088/1402-4896/abaf8f · Cited by 10
“We did not use any static magnetic shielding on our prototype and it is not to be confused with the well known Halbach magnetic array configurations [17, 18] which suppress the one net pole of the array (i.”
MethodSchlitz, R., Granovsky, S., Pohl, D., Thomas, A., Rellinghaus, B., & Goennenwein, S. T. B. (2021) · Physical review. B./Physical review. B · doi:10.1103/physrevb.103.214434 · Cited by 8
Design and Shimming Method of Low Length-to-Interdiameter Ratio Halbach Magnet
Wang, J., Jiang, X., Hu, Z., Chen, Y., Wu, Y., Bi, K., Ni, Z., Yi, H., & Lu, R. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3199233 · Cited by 8
“Among these permanent magnet structures, the Halbach structure [11], [12], [13], [14] has great potential to be applied in portable NMR instruments because it can produce stronger magnetic field intensity per unit mass than others.”
BackgroundOptimization of Quasi-Halbach Topologies to Maximize the Acceleration of Moving-Magnet Planar Motors
Kleijer, M., Jansen, J. W., & Lomonova, E. A. (2022) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem51905.2022.9910902 · Cited by 8
“Such a magnet array approximates an ideal sinusoidal magnetization pattern, which provides a flux focusing effect [8].”
BackgroundHigh-Accuracy Atomic Force Microscope
Trumper, D. L., Hocken, R. J., Amin-Shahidi, D., Ljubicic, D. M., & Overcash, J. L. (2011) · Lecture notes in control and information sciences · doi:10.1007/978-3-642-22173-6_2 · Cited by 8
“Its moving stage is neutrally-buoyant in fluorosilicone oil, and is controlled in 6 degrees of freedom using 4 levitation linear motors.These linear motors use Halbach magnet arrays ( 12 ; 13) attached to the moving stage.”
BackgroundMiniature magnetic resonance spectrometers
Rim, S. S., Mysoor, N. R., & Carnes, S. R. (2002) · IEEE/AIAA Digital Avionics Systems Conference (DASC) · doi:10.1109/dasc.1997.635034 · Cited by 8
High Resolution NMR Imaging using a High Field Yokeless Permanent Magnet
Kose, K., & Haishi, T. (2011) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.10.159 · Cited by 8
Magnetic Qualification of Permanent Magnet Quadrupoles for CERN's Linac4
Buzio, M., Golluccio, G., Lombardi, A., & Mateo, F. (2012) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2012.2185670 · Cited by 8
“We have also tentatively measured very high order harmonics which should be present according to the number and shape of the magnetized blocks [4].”
BackgroundMethodSingle-Plane Magnetically Focused Elongated Small Field Proton Beams
McAuley, G. A., Slater, J. M., & Wroe, A. J. (2014) · Technology in Cancer Research & Treatment · doi:10.1177/1533034614557409 · Cited by 8
“Such cylinders consist of sections of directionally magnetized material arranged to produce a high magnetic field inside a cylindrical cavity but with negligible field outside.(2) In this article, we present data from proton beams shaped by actual prototype quadrapole Halbach cylinders that were constructed from rare…”
BackgroundA polyvalent harmonic coil testing method for small-aperture magnets
Arpaïa, P., Buzio, M., Golluccio, G., & Walckiers, L. (2012) · Review of Scientific Instruments · doi:10.1063/1.4746281 · Cited by 8
Design study of magnet shapes for axial Halbach arrays using 3D finite element analyses
Winter, O., Kral, C., & Schmidt, E. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350261 · Cited by 8
“Halbach, a physicist and eponym for the so called Halbach effect [13].”
BackgroundIronless in-wheel hub motor design by using multi-domain finite element analyses
Winter, O., Ucsnik, S., Rudolph, M., Kral, C., & Schmidt, E. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264394 · Cited by 8
“Halbach who worked on undulators for the production of synchrotron radiation [8].”
BackgroundBorchardt, N., & Kasper, R. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8001995 · Cited by 8
“A new magnetization pattern, with spatially rotating magnetization was presented by Halbach in [3].”
BackgroundMonte Carlo evaluation of magnetically focused proton beams for radiosurgery
McAuley, G. A., Heczko, S. L., Nguyen, T. T., Slater, J. M., Slater, J. D., & Wroe, A. J. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaaa92 · Cited by 8
“(Continued) Commercial manufacture of focusing magnets consisting of assemblies of rare-earth permanent magnetic material fashioned as Halbach cylinders (Halbach 1980) is currently feasible.”
BackgroundMethodTopology optimization for three-dimensional design of segmented permanent magnet arrays
Lee, J., Lee, J., Jung, T., & Yoo, J. (2020) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-020-02656-7 · Cited by 8
“In Halbach (1980), the magnetic field inside a dipole Halbach cylinder is analytically derived as:”
BackgroundMethodInfluentialAccounting for material imperfections in the design and optimization of low cost Halbach magnets
Bogaychuk, A., & Kuzmin, V. (2020) · Review of Scientific Instruments · doi:10.1063/5.0013274 · Cited by 8
Partitioned stator flux reversal machines having Halbach array PMs
Zheng, M., Wu, Z., & Zhu, Z. Q. (2015) · IEEE International Magnetics Conference · doi:10.1109/intmag.2015.7157402 · Cited by 8
Петковска, Л., Cvetkovski, G. V., & Lefley, P. (2016) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-03-2016-0114 · Cited by 8
Three-Dimensional Field Solutions for Multi-Pole Cylindrical Halbach Arrays in an Axial Orientation
Thompson, W. K. (2013) · NASA Technical Reports Server (NASA) · Cited by 8
Permanent magnet systems for free-electron lasers
Gottschalk, S. C., Dowell, D. H., & Quimby, D. C. (2003) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)00867-2 · Cited by 8
Optimization studies of a 14.4 GHz ECR ion source for the superconductive linac at Legnaro
Cavenago, M., & Bisoffi, G. (1991) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90732-6 · Cited by 8
Metadata
- Authors
- Halbach, K.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Halbach, K.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1980-02
- Volume
- 169
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2217051974
- Semantic Scholar
- 580b6913a8f04beafda2139d01bb63fd797f213e
- Cited by
- 1,532
- References
- 5
- Citations by year
- 2026: 66 · 2025: 63 · 2024: 57 · 2023: 76 · 2022: 74 · 2021: 87 · 2020: 84 · 2019: 56 · 2018: 69 · 2017: 81 · 2016: 74 · 2015: 59 · 2014: 48 · 2013: 63 · 2012: 51
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Nuclear Instruments and Methods (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- quadrupole magnets, magnetic field design, undulator, synchrotron radiation, solenoidal vector fields, helical undulator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.