Force and velocity measured for single kinesin molecules
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We measured the force-velocity curves of single kinesin molecules attached to silica beads moving in an in vitro motility assay. Optical trapping interferometry was used to track movement with subnanometer precision and to apply calibrated, pN-sized forces to the beads. Velocity decreased linearly with increasing force, and kinesin molecules moved against applied loads of up to 5-6 pN. Comparison of force-velocity curves at limiting and saturating ATP concentrations suggests that the load-dependent diminution in kinesin velocity may be due to a decrease in the net displacement per molecule of ATP hydrolyzed, not simply to a slowing of the ATP turnover rate; kinesin would therefore appear to be a loosely coupled motor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Deviations from that cycle, such as those resulting in backsteps towards the microtubule minus end, occur only rarely, or in response to external loads that approach or exceed the stall force9.”
From A universal pathway for kinesin stepping (2011) · cites this paper as [9]
In the citing paper
“Individual WT motors were motile in the absence of load, stalled on the microtubule when approaching the detachment force, and detached from the microtubule at an average force of 4.6 ± 0.8 pN (Figure 3B,C), consistent with previous studies (Khalil et al., 2008; Svoboda and Block, 1994).”
From Neck linker docking is critical for Kinesin-1 force generation in cells but at a cost to motor speed and processivity (2019) · cites this paper as Svoboda and Block, 1994
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
Muscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 2,318 · cited 2×
“The crossbridge model proposed by A. F. Huxley was among the first to explain existing data and made quantitative predictions for muscle (Huxley, 1957).”
BackgroundMethodIdentification of a novel force-generating protein, kinesin, involved in microtubule-based motility
VALE, R., REESE, T., & SHEETZ, M. (1985) · Cell · doi:10.1016/s0092-8674(85)80099-4 · Cited by 1,993
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915 · cited 1×
“Recently, stepwise displacements and corresponding forces for the actomyosin system were reported, using both optical trapping (Finer et al., 1994) and flexible glass microneedle technologies (Ishijima et al., 1994).”
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910 · cited 17×
“The required nonlinear voltage sequence for this movement was determined separately by nanometer-level video tracking of single beads bound to a coverglass and calibrated against a diamond-ruled grid with 10 urn spacing (Gelles et al., 1988; Svoboda et al., 1993).”
BackgroundMethodResultInfluentialSelf-citationBiological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792 · cited 8×
“Large distance from the coverglass affects trapping force, mainly owing to the increasing spherical aberration in light (Svoboda and Block, 1994), and it is unclear whether calibration experiments were carried out at the same distance from the coverglass surface as the actual assays, or adjusted for any possible diffe…”
BackgroundMethodInfluentialSelf-citationForces of a single-beam gradient laser trap on a dielectric sphere in the ray optics regime
Ashkin, A. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81860-x · Cited by 1,681
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038 · cited 2×
“We conclude that single kinesin molecules suffice to move beads, confirming earlier work (Howard et al., 1989; Block et al., 1990).”
BackgroundResultSelf-citationFluid Mechanics of Propulsion by Cilia and Flagella
Brennen, C., & Winet, H. (1977) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.09.010177.002011 · Cited by 959
Cited by
Items 101–200 of 907
Computer simulations reveal motor properties generating stable antiparallel microtubule interactions
Nédélec, F. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200202051 · Cited by 194
“The model for the motors is inspired from the measured behavior of kinesin, which is a processive motor whose speed varies almost linearly with the load (Hunt et al., 1994; Svoboda and Block, 1994).”
BackgroundDistinguishing Inchworm and Hand-Over-Hand Processive Kinesin Movement by Neck Rotation Measurements
Hua, W., Chung, J., & Gelles, J. (2002) · Science · doi:10.1126/science.1063089 · Cited by 194
Moving into the cell: single-molecule studies of molecular motors in complex environments
Veigel, C., & Schmidt, C. F. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3062 · Cited by 176
Rosenfeld, S. S., Fordyce, P. M., Jefferson, G. M., King, P. H., & Block, S. M. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m300849200 · Cited by 188
Self-citationBidirectional cooperative motion of molecular motors
Badoual, M., Jülicher, F., & Prost, J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.102692399 · Cited by 190
Force measurements on cargoes in living cells reveal collective dynamics of microtubule motors
Hendricks, A. G., Holzbaur, E. L. F., & Goldman, Y. E. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215462109 · Cited by 185
“Previous studies suggest that bidirectional cargoes are often driven by few kinesin motors with unitary stall forces of ∼5 to 6 pN (27, 28) andmany dynein motors with unitary stall forces of∼1 pN, nearly balancing the net forces in the plus andminus end directions (12, 19).”
BackgroundResultThe mammalian dynein–dynactin complex is a strong opponent to kinesin in a tug-of-war competition
Belyy, V., Schlager, M. A., Foster, H., Reimer, A. E., Carter, A. P., & Yildiz, A. (2016) · Nature Cell Biology · doi:10.1038/ncb3393 · Cited by 182
“Finally, to ensure that trapped beads are driven by a single motor, we quantified the fraction of motile beads as a function of dynein concentration 30 (Fig.”
Leite, I. T., Turtaev, S., Jiang, X., Šiler, M., Cuschieri, A., Russell, P. S. J., & Čižmár, T. (2018) · Nature Photonics · doi:10.1038/s41566-017-0053-8 · Cited by 184
Single cytoplasmic dynein molecule movements: characterization and comparison with kinesin
Wang, Z., Khan, S., & Sheetz, M. P. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80071-8 · Cited by 184
Alternate fast and slow stepping of a heterodimeric kinesin molecule
Kaseda, K., Higuchi, H., & Hirose, K. (2003) · Nature Cell Biology · doi:10.1038/ncb1067 · Cited by 179
A mutant of the motor protein kinesin that moves in both directions on microtubules
Endow, S. A., & Higuchi, H. (2000) · Nature · doi:10.1038/35022617 · Cited by 179
“02 or less that more than one motor could simultaneously interact with a microtubul”
BackgroundModels of Motor-Assisted Transport of Intracellular Particles
Smith, D. A., & Simmons, R. M. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75994-2 · Cited by 172
“…speeds on an isolated filament are expected to be load-independent for micron-sized particles and normal cytoplasm; the tension/velocity coefficient for viscous drag is two orders of magnitude smaller than the slope of the load-velocity line, namely 5 pNz s/mm for kinesin (Svoboda and Block, 1994).”
BackgroundInner-arm dynein c of Chlamydomonas flagella is a single-headed processive motor
Sakakibara, H., Kojima, H., Sakai, Y., Katayama, E., & Oiwa, K. (1999) · Nature · doi:10.1038/23066 · Cited by 178
Temperature Control Methods in a Laser Tweezers System
Mao, H., Ricardo Arias-Gonzalez, J., Smith, S. B., Tinoco, I., & Bustamante, C. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.054536 · Cited by 165
Kinesin and Dynein-Dynactin at Intersecting Microtubules: Motor Density Affects Dynein Function
Ross, J. L., Shuman, H., Holzbaur, E. L. F., & Goldman, Y. E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120014 · Cited by 159
A cytoplasmic dynein tail mutation impairs motor processivity
Ori-McKenney, K. M., Xu, J., Gross, S. P., & Vallee, R. B. (2010) · Nature Cell Biology · doi:10.1038/ncb2127 · Cited by 165
“The fraction of beads bound to microtubules was used to assess the average number of available motors per bead: 50–100% binding fractions correspond to the few motor condition, whereas ≤ 30% binding fractions correspond to the single-motor rang”
BackgroundThermal noise limitations on micromechanical experiments
Gittes, F., & Schmidt, C. F. (1998) · European Biophysics Journal · doi:10.1007/s002490050113 · Cited by 162
Counting of six pRNAs of phi29 DNA‐packaging motor with customized single‐molecule dual‐view system
Shu, D., Zhang, H., Jin, J., & Guo, P. (2007) · The EMBO Journal · doi:10.1038/sj.emboj.7601506 · Cited by 160
“…by single-molecule approaches, specifically for RNA ribozyme (Zhuang et al, 2000), helicase (Ha et al, 2002), RNA poly- merase (Wang et al, 1998), and other molecular motors such as myosin (Finer et al, 1994), kinesin (Svoboda and Block, 1994; Hess et al, 2002), and F1-ATPase (Adachi et al, 2000).”
BackgroundInfluentialThermodynamic Properties of the Kinesin Neck-Region Docking to the Catalytic Core
Rice, S., Cui, Y., Sindelar, C., Naber, N., Matuska, M., Vale, R., & Cooke, R. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74992-3 · Cited by 168
“, 1997; Schnitzer and Block 1997) and moves under loads of up to 6 pN (Svoboda and Block, 1994; Visscher et al., 1999).”
BackgroundTrapping of low-index microparticles in an optical vortex
Gahagan, K. T., & Swartzlander, G. A. (1998) · Journal of the Optical Society of America B · doi:10.1364/josab.15.000524 · Cited by 160
“Q gz 5 ~c/n0P!( ~m! Fgz ~m! . ( 11 ) B. Optical Vortex Trap Stable three-dimensional trapping requires a balance between the optical gradient and scattering forces to form a potential well sufficiently deep to overcome mechanical forces owing to buoyancy, viscous drag, or Brownian motion.”
BackgroundInfluentialMicroplates: a new tool for manipulation and mechanical perturbation of individual cells
Thoumine, O. R., Ott, A., Cardoso, O., & Meister, J.-J. (1999) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(98)00052-9 · Cited by 157
Harada, R., & Kitao, A. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4813023 · Cited by 168
Shimamoto, Y., Forth, S. T., & Kapoor, T. M. (2015) · Developmental Cell · doi:10.1016/j.devcel.2015.08.017 · Cited by 162
“This value is four to five times smaller than that reported for a truncated human kinesin-5 dimeric construct (Valentine et al., 2006) or vesicle-transporting kinesin-1 (Svoboda and Block, 1994).”
Background[38] Versatile optical traps with feedback control
Visscher, K. M., & Block, S. M. (1998) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(98)98040-5 · Cited by 169
Self-citationDirectional loading of the kinesin motor molecule as it buckles a microtubule
Gittes, F., Meyhöfer, E., Baek, S., & Howard, J. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79585-1 · Cited by 167
“These previous results from this laboratory, as well as results obtained by other laboratories (Svoboda and Block, 1994), show a motor speed, plotted versus the parallel component of load, that decreases roughly along a line from a maximum unloaded speed to stalling at a maximum force near 5 pN.”
BackgroundResultMotor proteins and molecular motors: how to operate machines at the nanoscale
Kolomeisky, A. B. (2013) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/25/46/463101 · Cited by 173
Structure and Mechanics of Dynein Motors
Canty, J. T., Tan, R., Kusakci, E., Fernandes, J., & Yildiz, A. (2021) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-111020-101511 · Cited by 128
Kinesin–microtubule binding depends on both nucleotide state and loading direction
Uemura, S., Kawaguchi, K., Yajima, J., Edamatsu, M., Toyoshima, Y. Y., & Ishiwata, S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.092546199 · Cited by 143
Stabilization of an optical microscope to 01 nm in three dimensions
Carter, A. R., King, G. M., Ulrich, T. A., Halsey, W. A., Alchenberger, D., & Perkins, T. T. (2007) · Applied Optics · doi:10.1364/ao.46.000421 · Cited by 142
Stretching type II collagen with optical tweezers
Sun, Y.-L., Luo, Z.-P., Fertala, A., & An, K. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.028 · Cited by 141
Kinetochore kinesin CENP-E is a processive bi-directional tracker of dynamic microtubule tips
Gudimchuk, N., Vitre, B., Kim, Y., Kiyatkin, A., Cleveland, D. W., Ataullakhanov, F. I., & Grishchuk, E. L. (2013) · Nature Cell Biology · doi:10.1038/ncb2831 · Cited by 137
Molecular shuttles: directed motion of microtubules along nanoscale kinesin tracks
Dennis, J. R., Howard, J., & Viola Vogel, B. (1999) · Nanotechnology · doi:10.1088/0957-4484/10/3/302 · Cited by 153
Interrogating Biology with Force: Single Molecule High-Resolution Measurements with Optical Tweezers
Capitanio, M., & Pavone, F. S. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.08.007 · Cited by 152
“Stall forces of kinesin (18), RNA polymerase (19), and many other motors have been measured using the single bead geometry.”
MethodSubsteps within the 8-nm step of the ATPase cycle of single kinesin molecules
Nishiyama, M., Muto, E., Inoue, Y., Yanagida, T., & Higuchi, H. (2001) · Nature Cell Biology · doi:10.1038/35070116 · Cited by 164
Kerssemakers, J., Howard, J., Hess, H., & Diez, S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0510400103 · Cited by 137
Myosin V and Kinesin act as tethers to enhance each others' processivity
Ali, M. Y., Lu, H., Bookwalter, C. S., Warshaw, D. M., & Trybus, K. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711531105 · Cited by 138
“Based on the force:velocity relationship for myoV and for kinesin (14, 15), the electrostatic interaction between the tethering motor and its heterologous track must be relatively weak and does not create an effective drag force 1 pN, which would be required to slow the movement of the active motor.”
BackgroundA Simple, Mechanistic Model for Directional Instability during Mitotic Chromosome Movements
Joglekar, A. P., & Hunt, A. J. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75148-5 · Cited by 147
“This is in striking contrast to the behavior of ATP-dependent motor proteins, which are slowed by increased loads (Schnitzer et al., 2000; Meyhofer and Howard, 1995; Hunt et al., 1994; Svoboda and Block, 1994; Oiwa and Takahashi, 1988; Hill, 1938).”
BackgroundResultRegulatory ATPase Sites of Cytoplasmic Dynein Affect Processivity and Force Generation
Cho, C., Reck-Peterson, S. L., & Vale, R. D. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m802951200 · Cited by 137
Forward and Reverse Motion of Single RecBCD Molecules on DNA
Perkins, T. T., Li, H., Dalal, R. V., Gelles, J., & Block, S. M. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74232-0 · Cited by 145
“Measuring how velocity varies with external force can provide insight into the mechanochemistry of motor enzymes (Finer et al., 1994; Leibler and Huse, 1993; Svoboda and Block, 1994b; Wang et al., 1998).”
BackgroundSelf-citationGanguly, S., Williams, L. S., Palacios, I. M., & Goldstein, R. E. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1203575109 · Cited by 148
“5 pN (35) and an average speed in the cytoplasm of 115 nm∕s (in vivo measurement, n 1⁄4 50), then φm ≃ 630 × 10−21W .”
Coordination of molecular motors: from in vitro assays to intracellular dynamics
Holzbaur, E. L., & Goldman, Y. E. (2010) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2009.12.014 · Cited by 130
Nucleotide-Dependent Single- to Double-Headed Binding of Kinesin
Kawaguchi, K., & Ishiwata, S. (2001) · Science · doi:10.1126/science.291.5504.667 · Cited by 132
Backsteps induced by nucleotide analogs suggest the front head of kinesin is gated by strain
Guydosh, N. R., & Block, S. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600931103 · Cited by 132
Self-citationControlling Kinesin by Reversible Disulfide Cross-Linking
Tomishige, M., & Vale, R. D. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.151.5.1081 · Cited by 132
“98% of the observed bead movements are expected to be generated by a single kinesin molecule (Svoboda and Block, 1994).”
BackgroundLeidel, C., Longoria, R. A., Gutierrez, F. M., & Shubeita, G. T. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.06.038 · Cited by 148
“For stall force measurements, the stiffness (k) of the trap needs to be calibrated and the cargo stall force is then calculated using Hooke’s law by measuring the stall distance (13,22).”
MethodOptical trapping in vivo : theory, practice, and applications
Favre‐Bulle, I. A., Stilgoe, A. B., Scott, E. K., & Rubinsztein-Dunlop, H. H. (2018) · Nanophotonics · doi:10.1515/nanoph-2019-0055 · Cited by 145
Canty, J. T., Hensley, A., Aslan, M., Jack, A., & Yildiz, A. (2023) · Nature Communications · doi:10.1038/s41467-023-36945-8 · Cited by 131
Conformational changes during kinesin motility
Schief, W. R., & Howard, J. (2001) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(00)00169-1 · Cited by 131
Towards the application of cytoskeletal motor proteins in molecular detection and diagnostic devices
Korten, T., Månsson, A., & Diez, S. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.05.001 · Cited by 141
Translation at the Single-Molecule Level
Marshall, R. A., Aitken, C. E., Dorywalska, M., & Puglisi, J. D. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.070606.101431 · Cited by 125
Light forces the pace: optical manipulation for biophotonics
Stevenson, D. J., Gunn‐Moore, F. J., & Dholakia, K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3475958 · Cited by 147
Force spectroscopy on single passive biomolecules and single biomolecular bonds
Merkel, R. (2001) · Physics Reports · doi:10.1016/s0370-1573(00)00103-4 · Cited by 130
Moore, S. W., Keller, R. E., & Koehl, M. A. R. (1995) · Development · doi:10.1242/dev.121.10.3131 · Cited by 142
Single Molecule Detection in Life Sciences
Ishii, Y., & Yanagida, T. (2000) · Single Molecules · doi:10.1002/(sici)1438-5171(200004)1:1<5::aid-simo5>3.0.co;2-a · Cited by 153
Optical traps for single molecule biophysics: a primer
Perkins, T. T. (2008) · Laser & Photonics Review · doi:10.1002/lpor.200810014 · Cited by 130
“Calibrated measurements allow detailed study of kinetics [8,9] and energetics [10–13] of biological systems.”
BackgroundMechanical design of DNA nanostructures
Castro, C. E., Su, H.-J., Marras, A. E., Zhou, L., & Johnson, J. (2015) · Nanoscale · doi:10.1039/c4nr07153k · Cited by 125
Civelekoglu‐Scholey, G., Sharp, D. J., Mogilner, A., & Scholey, J. M. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.078691 · Cited by 134
“We assume that all motor proteins considered in this work obey a linear force velocity relationship similar to conventional kinesin (39), and as recently proposed in a theoretical framework for cytoplasmic dynein (41).”
BackgroundAutoinhibition regulates the motility of the C. elegans intraflagellar transport motor OSM-3
Imanishi, M., Endres, N. F., Gennerich, A., & Vale, R. D. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200605179 · Cited by 120
“The solid line represents the fi t to the Poisson distribution 1 − exp(−λC) for one or more motor molecules (reduced x2 = 0.31; Svoboda and Block, 1994).”
BackgroundInfluentialCellular chemomechanics at interfaces: sensing, integration and response
Girard, P., Cavalcanti‐Adam, E. A., Kemkemer, R., & Spatz, J. P. (2007) · Soft Matter · doi:10.1039/b614008d · Cited by 133
Germanium nanospheres for ultraresolution picotensiometry of kinesin motors
Sudhakar, S., Abdosamadi, M. K., Jachowski, T. J., Bugiel, M., Jannasch, A., & Schäffer, E. (2021) · Science · doi:10.1126/science.abd9944 · Cited by 121
Temperature Dependence of Force, Velocity, and Processivity of Single Kinesin Molecules
Kawaguchi, K., & Ishiwata, S. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.2856 · Cited by 135
Kinetics of force generation by single kinesin molecules activated by laser photolysis of caged ATP
Higuchi, H., Muto, E., Inoue, Y., & Yanagida, T. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.9.4395 · Cited by 123
Calibration of Optical Tweezers for In Vivo Force Measurements: How do Different Approaches Compare?
Jun, Y., Tripathy, S. K., Narayanareddy, B. R. J., Mattson-Hoss, M. K., & Gross, S. P. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2014.07.033 · Cited by 128
Detection of sub-8-nm movements of kinesin by high-resolution optical-trap microscopy.
Coppin, C. M., Finer, J. T., Spudich, J. A., & Vale, R. D. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.5.1913 · Cited by 120
Force Generation in RNA Polymerase
Wang, H.-Y., Elston, T. C., Mogilner, A. J., & OSTER, G. F. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77834-8 · Cited by 133
“However, laser trap experiments have shown that it can move against a load several times greater than the maximum force developed by kinesin (M. D. Wang, personal communication ; Svoboda and Block, 1994).”
BackgroundMavroidis, C., Dubey, A., & Yarmush, M. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140143 · Cited by 131
Loading direction regulates the affinity of ADP for kinesin
Uemura, S., & Ishiwata, S. (2003) · Nature Structural & Molecular Biology · doi:10.1038/nsb911 · Cited by 119
“Kinesin is a processive motor that 'walks' along a microtubule toward its plus end and is essential for the transport of vesicles and organelle”
BackgroundSynthetic biology of minimal systems
Schwille, P., & Diez, S. (2009) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.1080/10409230903074549 · Cited by 115
Entropy rectifies the Brownian steps of kinesin
Taniguchi, Y., Nishiyama, M., Ishii, Y., & Yanagida, T. (2005) · Nature Chemical Biology · doi:10.1038/nchembio741 · Cited by 116
“Assuming Poisson statistics, >95% of the moving beads were estimated to be driven by a single kinesin molecul”
BackgroundMuscle Fatigue from the Perspective of a Single Crossbridge
DEBOLD, E. P., FITTS, R. H., SUNDBERG, C. W., & NOSEK, T. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001047 · Cited by 106
Intracellular transport driven by cytoskeletal motors: General mechanisms and defects
Appert-Rolland, C., Ebbinghaus, M., & Santen, L. (2015) · Physics Reports · doi:10.1016/j.physrep.2015.07.001 · Cited by 128
“In [356] the following velocity-force relations of single motors have been suggested:”
Thin-foil magnetic force system for high-numerical-aperture microscopy.
Fisher, J., Cribb, J., Desai, K., Vicci, L., Wilde, B., Keller, K., Taylor, R., Haase, J., Bloom, K., O'Brien, E., et al. (2006) · Review of Scientific Instruments · doi:10.1063/1.2166509 · Cited by 112
Dynamic Concentration of Motors in Microtubule Arrays
Nédélec, F., Surrey, T., & Maggs, A. C. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.3192 · Cited by 123
Nonequilibrium Energetics of Molecular Motor Kinesin
Ariga, T., Tomishige, M., & Mizuno, D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.218101 · Cited by 128
Spiral Defects in Motility Assays: A Measure of Motor Protein Force
Bourdieu, L., Duke, T., Elowitz, M. B., Winkelmann, D. A., Leibler, S., & Libchaber, A. J. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.176 · Cited by 125
Interaction Forces between F-Actin and Titin PEVK Domain Measured with Optical Tweezers
Bianco, P., Nagy, A., Kengyel, A. M., Szatmári, D., Mártonfalvi, Z., Huber, T., & Kellermayer, M. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.106153 · Cited by 122
“where P(d) is binding probability at coating density d, and l is a fitting paramenter (22).”
BackgroundBao, G. (2002) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(02)00035-2 · Cited by 121
Orientation Dependence of Displacements by a Single One-Headed Myosin Relative to the Actin Filament
Tanaka, H., Ishijima, A., Honda, M., Saito, K., & Yanagida, T. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77629-5 · Cited by 120
“…manipulation of protein molecules by a microneedle (Kishino and Yanagida, 1988; Ishijima et al., 1991) and an optical trap (Svoboda et al., 1993; Svoboda and Block, 1994) have allowed forces and displacements to be measured directly from single myosin molecules bound to the surface of an…”
BackgroundInfluentialToward kinesin-powered microdevices
Limberis, L., & Stewart, R. J. (2000) · Nanotechnology · doi:10.1088/0957-4484/11/2/301 · Cited by 112
Processive movement of single 22S dynein molecules occurs only at low ATP concentrations
Hirakawa, E., Higuchi, H., & Toyoshima, Y. Y. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.050585297 · Cited by 127
Processive kinesins require loose mechanical coupling for efficient collective motility
Bieling, P., Telley, I. A., Piehler, J., & Surrey, T. (2008) · EMBO reports · doi:10.1038/embor.2008.169 · Cited by 111
“It is known that individual kinesins slow down when experiencing a hindering load (Svoboda & Block, 1994; Carter & Cross, 2005).”
BackgroundKulić, I. M., & Schießel, H. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.228101 · Cited by 106
Forces on a colloidal particle in a polymer solution: a study using optical tweezers
Valentine, M. T., Dewalt, L. E., & Ou‐Yang, H. D. (1996) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/8/47/048 · Cited by 106
Spring mechanics of α-helical polypeptide
Idiris, A., Alam, M. T., & Ikai, A. (2000) · Protein Engineering Design and Selection · doi:10.1093/protein/13.11.763 · Cited by 104
Spontaneous oscillations of elastic filaments induced by molecular motors
Canio, G. D., Lauga, E., & Goldstein, R. E. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0491 · Cited by 112
“Typical speeds of molecular motors in animals are fractions of microns/sec, while the forces they exert are on the piconewton scale [25].”
BackgroundForce is a signal that cells cannot ignore
Yusko, E. C., & Asbury, C. L. (2014) · Molecular Biology of the Cell · doi:10.1091/mbc.e13-12-0707 · Cited by 103
Marshall, W. F., Marko, J. F., Agard, D. A., & Sedat, J. W. (2001) · Current Biology · doi:10.1016/s0960-9822(01)00180-4 · Cited by 101
Arpağ, G., Shastry, S., Hancock, W. O., & Tüzel, E. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2014.09.009 · Cited by 101
Drosophila Ensconsin Promotes Productive Recruitment of Kinesin-1 to Microtubules
Sung, H.-H., Telley, I. A., Papadaki, P., Ephrussi, A., Surrey, T., & Rørth, P. (2008) · Developmental Cell · doi:10.1016/j.devcel.2008.10.006 · Cited by 108
Force and Velocity of Mycoplasma mobile Gliding
Miyata, M., Ryu, W. S., & Berg, H. C. (2002) · Journal of Bacteriology · doi:10.1128/jb.184.7.1827-1831.2002 · Cited by 107
“The stall force is five to seven times that of myosin and kinesin (9, 34) and comparable to that generated by RNA polymerase (36) or a force-generating element of the flagellar motor (6).”
BackgroundLaser-Guided Assembly of Heterotypic Three-Dimensional Living Cell Microarrays
Akselrod, G. M., Timp, W., Mirsaidov, U. M., Zhao, Q., Li, C. Y., Timp, R., Timp, K., Matsudaira, P. T., & Timp, G. L. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.084079 · Cited by 98
Optimized back-focal-plane interferometry directly measures forces of optically trapped particles
Farré, A., Marsà, F., & Montes‐Usategui, M. (2012) · Optics Express · doi:10.1364/oe.20.012270 · Cited by 104
Molecular motors and the forces they exert
Fisher, M. E., & Kolomeisky, A. B. (1999) · Physica A Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(99)00389-1 · Cited by 107
An Integrated Laser Trap/Flow Control Video Microscope for the Study of Single Biomolecules
Wuite, G. J. L., Davenport, R. J., Rappaport, A., & Bustamante, C. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76369-7 · Cited by 96
“7; Svoboda and Block, 1994a).”
InfluentialModelling microtubule patterns
Karsenti, E., Nédélec, F., & Surrey, T. (2006) · Nature Cell Biology · doi:10.1038/ncb1498 · Cited by 108
Building Complexity: Insights into Self-Organized Assembly of Microtubule-Based Architectures
Subramanian, R., & Kapoor, T. M. (2012) · Developmental Cell · doi:10.1016/j.devcel.2012.10.011 · Cited by 99
“For example, the velocity of kinesin-5 is not greatly reduced over a wide range of opposing loads, while other kinesins, such as kinesin-1, exhibit steep dependencies in the same range (Svoboda and Block, 1994; Valentine et al., 2006).”
BackgroundForth, S., Hsia, K.-C., Shimamoto, Y., & Kapoor, T. M. (2014) · Cell · doi:10.1016/j.cell.2014.02.018 · Cited by 90
“Single-molecule force spectroscopy studies of motor proteins have shown that their stepping velocity can be decreased when they must work against an applied force and can increase when an assisting load is applied (Gennerich et al., 2007; Svoboda and Block, 1994; Valentine et al., 2006).”
Determinants of molecular motor directionality
Endow, S. A. (1999) · Nature Cell Biology · doi:10.1038/14113 · Cited by 110
Lane, J. D., & Allan, V. J. (1999) · Molecular Biology of the Cell · doi:10.1091/mbc.10.6.1909 · Cited by 93
“…presence of 20 mM van- adate in extracts prepared at the second embryonic interphase from electrically activated eggs (Figure 2A), and directionality assays demonstrated that ER tubule movements in second interphase extracts were exclusively toward the minus ends of microtubules (n 5 16; Table 1).”
BackgroundThe kinesin walk: a dynamic model with elastically coupled heads.
Derényi, I., & Vicsek, T. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.13.6775 · Cited by 95
Metadata
- Authors
- Svoboda, K., & Block, S. M.
- Affiliations
- Harvard University (US)
- Princeton University (US)
- ORCID
- Svoboda, Karel
- Venue
- Cell
- Publisher
- Elsevier BV
- Published
- 1994-06
- Volume
- 77
- Issue
- 5
- Pages
- 773-784
- ISSN
- 0092-8674 (ISSN-L)
- OpenAlex
- W2170640142
- Semantic Scholar
- 695d8b76bd2edf0e513fbcf461fe0c62d7b64af3
- Cited by
- 909
- References
- 43
- Citations by year
- 2026: 19 · 2025: 19 · 2024: 16 · 2023: 22 · 2022: 23 · 2021: 34 · 2020: 21 · 2019: 32 · 2018: 24 · 2017: 34 · 2016: 41 · 2015: 31 · 2014: 39 · 2013: 38 · 2012: 33
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Cell (publishedVersion)
- PubMed (publishedVersion)
- Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) (acceptedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- kinesin, force-velocity relationship, single-molecule force measurement, in vitro motility assay, silica beads, ATP hydrolysis, motor protein mechanics
- MeSH terms
- Adenosine Triphosphate, Animals, Biomechanical Phenomena, Hydrolysis, Interferometry, Kinetics, Silicon Dioxide, Thermodynamics, Kinesins, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.