Pacemaker-implantation complication rates: An analysis of some contributing factors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An examination of 632 consecutive pacemaker implantations performed at a single institution by 29 implanting physicians over a 5 year period was made to determine which factors affected the 37 perioperative complications experienced. The introducer method of vein access contributed significantly to the complication rate, which was also related to the number of physician implanters on the staff and the makeup of the implantation teams. Of greatest interest was the substantially large incidence of complications experienced by implanters who performed fewer than 12 implantations per year, and particularly the incidence of lead-related complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernstein, A. D., Camm, A. J., Fletcher, R. D., Gold, R. D., Rickards, A. F., Smyth, N. P. D., Spielman, S. R., & Sutton, R. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb06035.x · Cited by 157
Self-citation
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
“Literature highlights that complications of PM implantation are largely determined by patient(23) and operatorependent characteristics.(4,23,26) In contrast, long-term complications are mostly evoked by the device and leads.”
BackgroundClinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & REISER, C. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.t01-1-00804.x · Cited by 308
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0392-0 · Cited by 266
Complications Related to Permanent Pacemaker Therapy
KIVINIEMI, M. S., PIRNES, M. A., ERÄNEN, H. J. K., KETTUNEN, R. V. J., & HARTIKAINEN, J. E. K. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00534.x · Cited by 261
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Pocket Hematoma After Pacemaker or Implantable Cardioverter Defibrillator Surgery
Wiegand, U. K. H., LeJeune, D., Boguschewski, F., Bonnemeier, H., Eberhardt, F., Schunkert, H., & Bode, F. (2004) · Chest · doi:10.1378/chest.126.4.1177 · Cited by 223
Complications arising after implantation of DDD pacemakers: the MOST experience
Ellenbogen, K. A., Hellkamp, A. S., Wilkoff, B. L., Camunãs, J. L., Love, J. C., Hadjis, T. A., Lee, K. L., & Lamas, G. A. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00844-0 · Cited by 210
Al-Khatib, S. M., Lucas, F. L., Jollis, J. G., Malenka, D. J., & Wennberg, D. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.04.063 · Cited by 194
“Examining 632 consecutive pacemaker implantations at a single institution, Parsonnet et al. ( 21 ) showed an appreciably higher incidence of complications for implanters who performed fewer than 12 pacemaker implantations per year.”
BackgroundLate complications following permanent pacemaker implantation or elective unit replacement
Harcombe, A. A., Newell, S. A., Ludman, P. F., Wistow, T. E., Sharples, L. D., Schofield, P. M., Stone, D. L., Shapiro, L. M., Cole, T., & Petch, M. C. (1998) · Heart · doi:10.1136/hrt.80.3.240 · Cited by 163
Metadata
- Authors
- Parsonnet, V., Bernstein, A. D., & Lindsay, B.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1989-03
- Volume
- 13
- Issue
- 4
- Pages
- 917-921
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2042151918
- Cited by
- 176
- References
- 1
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.