The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Electrocardiographic indexes of dispersion of ventricular repolarization: An isolated heart validation study
Open accessAbstract
OBJECTIVES: This study tested the correlation of QT and JT dispersion and other potentially useful electrocardiographic (ECG) indexes with dispersion of repolarization and recovery time. BACKGROUND: Dispersion of ventricular repolarization is currently being assessed noninvasively from the surface ECG by means of QT and JT dispersion, although their correlation with dispersion of repolarization as measured directly from the myocardium is not well established. METHODS: Multiple monophasic action potentials were recorded simultaneously with a 12-lead ECG from isolated Langendorff-perfused rabbit hearts. The QT and JT dispersion was compared with the dispersion of monophasic action potential duration at 90% repolarization (APD90) and with dispersion of recovery time. As new ECG indexes, total T wave area, T wave area after the peak (late T wave area) and T peak to T end interval were also tested. RESULTS: The QT and JT dispersion showed a significant correlation with the dispersion of APD90 and the dispersion of recovery time (r values between 0.58 and 0.64, respectively, p < 0.001). However, total T wave area showed better correlation, respectively, with dispersion of APD90 and recovery time (r = 0.79 and r = 0.82, p < 0.0001), as did late T wave area (r = 0.81 and r = 0.81, p < 0.0001) and T peak to T end interval (r = 0.81 and r = 0.82, p < 0.0001). CONCLUSIONS: The JT and QT dispersion correlate significantly with dispersion of APD90 and recovery time. The ECG assessment of dispersion of repolarization can be improved by three new ECG dispersion indexes: T peak to T end interval, total T wave area and late T wave area. These new indexes should be tested clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QT dispersion: an indication of arrhythmia risk in patients with long QT intervals.
Day, C. P., McComb, J. M., & Campbell, R. W. (1990) · Heart · doi:10.1136/hrt.63.6.342 · Cited by 1,189
Nonuniform Recovery of Excitability in Ventricular Muscle
HAN, J., & MOE, G. K. (1964) · Circulation Research · doi:10.1161/01.res.14.1.44 · Cited by 942
Kuo, C. S., Munakata, K., Reddy, C. P., & Surawicz, B. (1983) · Circulation · doi:10.1161/01.cir.67.6.1356 · Cited by 747
Wilson, F. N., Macleod, A. G., Barker, P. S., & Johnston, F. D. (1934) · American Heart Journal · doi:10.1016/s0002-8703(34)90303-3 · Cited by 413
Franz, M. R., Cima, R., Wang, D., Profitt, D., & Kurz, R. (1992) · Circulation · doi:10.1161/01.cir.86.3.968 · Cited by 411
Self-citationDispersion of the QT interval. A marker of therapeutic efficacy in the idiopathic long QT syndrome.
Priori, S. G., Napolitano, C., Diehl, L., & Schwartz, P. J. (1994) · Circulation · doi:10.1161/01.cir.89.4.1681 · Cited by 395
Hii, J. T., Wyse, D. G., Gillis, A. M., Duff, H. J., Solylo, M. A., & Mitchell, L. B. (1992) · Circulation · doi:10.1161/01.cir.86.5.1376 · Cited by 385
Franz, M. R., Bargheer, K., Rafflenbeul, W., Haverich, A., & Lichtlen, P. R. (1987) · Circulation · doi:10.1161/01.cir.75.2.379 · Cited by 352
Self-citationSpatial variation of QT intervals in normal persons and patients with acute myocardial infarction
Mirvis, D. M. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80387-9 · Cited by 238
Reduction in QT dispersion by sotalol following myocardial infarction
DAY, C. P., McCOMB, J. M., MATTHEWS, J., & CAMPBELL, R. W. F. (1991) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059911 · Cited by 203
Cited by
Sudden Death Due to Cardiac Arrhythmias
Huikuri, H. V., Castellanos, A., & Myerburg, R. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmra000650 · Cited by 1,466
Measurement, interpretation and clinical potential of QT dispersion
Malik, M., & Batchvarov, V. N. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00962-1 · Cited by 631
The M Cell: Its Contribution to the ECG and to Normal and Abnormal Electrical Function of the Heart
ANTZELEVITCH, C., SHIMIZU, W., YAN, G., SICOURI, S., WEISSENBURGER, J., NESTERENKO, V. V., BURASHNIKOV, A., DI DIEGO, J., SAFFITZ, J., & THOMAS, G. P. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00287.x · Cited by 611
Okin, P. M., Devereux, R. B., Howard, B. V., Fabsitz, R. R., Lee, E. T., & Welty, T. K. (2000) · Circulation · doi:10.1161/01.cir.101.1.61 · Cited by 381
Drici, M. D., Burklow, T. R., Haridasse, V., Glazer, R. I., & Woosley, R. L. (1996) · Circulation · doi:10.1161/01.cir.94.6.1471 · Cited by 372
Metadata
- Authors
- Zabel, M., Portnoy, S., & Franz, M. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1995-03
- Volume
- 25
- Issue
- 3
- Pages
- 746-752
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2054469718
- Cited by
- 418
- References
- 20
- FWCI
- 27.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrocardiographic indexes of dispersion of ventricular repolarization: An isolated heart validation study. https://app.cochat.ai/papers/10.1016/0735-1097(94)00446-w
- The paper
- Zabel, M., Portnoy, S., & Franz, M. R. (1995). Electrocardiographic indexes of dispersion of ventricular repolarization: An isolated heart validation study. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(94)00446-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.