Biosensing with surface plasmon resonance — how it all started
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface plasmon resonance for gas detection and biosensing
Liedberg, B., Nylander, C., & Lunström, I. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85036-7 · Cited by 2,539
Self-citationDie Bestimmung optischer Konstanten von Metallen durch Anregung von Oberflächenplasmaschwingungen
Kretschmann, E. (1971) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01395428 · Cited by 1,695
Johnsson, B., Löfås, S., & Lindquist, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90424-r · Cited by 1,262
Karlsson, R., Michaelsson, A., & Mattsson, L. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90331-9 · Cited by 1,077
Jönsson, U., Fägerstam, L. G., Ivarsson, B., Johnsson, B., Karlsson, R., Lundh, K., Löfås, S., Persson, B. S., Roos, H., & Rönnberg, I. (1991) · PubMed · Cited by 902
Löfås, S., & Johnsson, B. (1990) · J. Chem. Soc., Chem. Commun. · doi:10.1039/c39900001526 · Cited by 766
Gas detection by means of surface plasmon resonance
Nylander, C., Liedberg, B., & Lind, T. (1982) · Sensors and Actuators · doi:10.1016/0250-6874(82)80008-5 · Cited by 745
Self-citationSensitivity of grating couplers as integrated-optical chemical sensors
Tiefenthaler, K., & Lukosz, W. (1989) · Journal of the Optical Society of America B · doi:10.1364/josab.6.000209 · Cited by 620
Principles of biosensing with an extended coupling matrix and surface plasmon resonance
Liedberg, B., Lundström, I., & Stenberg, E. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)85239-7 · Cited by 524
Self-citationProtein-Protein Interactions Contributing to the Specificity of Intracellular Vesicular Trafficking
Calakos, N., Bennett, M. K., Peterson, K. E., & Scheller, R. H. (1994) · Science · doi:10.1126/science.8108733 · Cited by 399
Cited by
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
“Therefore, the sensing mechanism of SPR spectroscopy is based on the measurement of small changes in the refractive index in the vicinity of the surface of a conductive thin film [105, 107, 108, 109].”
MethodPlasmonic Surface Lattice Resonances: A Review of Properties and Applications
Kravets, V. G., Kabashin, A. V., Barnes, W. L., & Grigorenko, A. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00243 · Cited by 1,501
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Quantitative Interpretation of the Response of Surface Plasmon Resonance Sensors to Adsorbed Films
Jung, L. S., Campbell, C. T., Chinowsky, T. M., Mar, M. N., & Yee, S. S. (1998) · Langmuir · doi:10.1021/la971228b · Cited by 1,012
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Immunosensors—principles and applications to clinical chemistry
Luppa, P. B., Sokoll, L. J., & Chan, D. W. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00629-5 · Cited by 741
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Understanding Nanocellulose–Water Interactions: Turning a Detriment into an Asset
Solhi, L., Guccini, V., Heise, K., Solala, I., Niinivaara, E., Xu, W., Mihhels, K., Kröger, M., Meng, Z., Wohlert, J., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00611 · Cited by 506
Singular phase nano-optics in plasmonic metamaterials for label-free single-molecule detection
Kravets, V. G., Schedin, F., Jalil, R., Britnell, L., Gorbachev, R. V., Ansell, D., Thackray, B., Novoselov, K. S., Geim, A. K., Kabashin, A. V., et al. (2013) · Nature Materials · doi:10.1038/nmat3537 · Cited by 468
Campbell, C. T., & Kim, G. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.047 · Cited by 410
Biosensing Based on Light Absorption of Nanoscaled Gold and Silver Particles
Frederix, F., Friedt, J.-M., Choi, K.-H., Laureyn, W., Campitelli, A., Mondelaers, D., Maes, G., & Borghs, G. (2003) · Analytical Chemistry · doi:10.1021/ac0346609 · Cited by 381
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Refractometric Sensing Using Propagating versus Localized Surface Plasmons: A Direct Comparison
Svedendahl, M., Chen, S., Dmitriev, A., & Käll, M. (2009) · Nano Letters · doi:10.1021/nl902721z · Cited by 351
Improving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance
Dahlin, A. B., Tegenfeldt, J. O., & Höök, F. (2006) · Analytical Chemistry · doi:10.1021/ac0601967 · Cited by 329
Surface Plasmon Resonance-Based Immunoassays
Mullett, W. M., Lai, E. P. C., & Yeung, J. M. (2000) · Methods · doi:10.1006/meth.2000.1039 · Cited by 322
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Immunosensors: electrochemical sensing and other engineering approaches
Ghindilis, A. L., Atanasov, P., Wilkins, M., & Wilkins, E. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00031-6 · Cited by 287
A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7
Subramanian, A., Irudayaraj, J., & Ryan, T. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.007 · Cited by 281
Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers
Fathil, M. F. M., Md Arshad, M. K., Gopinath, S. C. B., Hashim, U., Adzhri, R., Ayub, R. M., Ruslinda, A. R., Nuzaihan M.N., M., Azman, A. H., Zaki, M., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.037 · Cited by 277
Graphene-protected copper and silver plasmonics
Kravets, V. G., Jalil, R., Kim, Y.-J., Ansell, D., Aznakayeva, D. E., Thackray, B., Britnell, L., Belle, B. D., Withers, F., Radko, I. P., et al. (2014) · Scientific Reports · doi:10.1038/srep05517 · Cited by 257
Xu, X., Peng, B., Li, D., Zhang, J., Wong, L. M., Zhang, Q., Wang, S., & Xiong, Q. (2011) · Nano Letters · doi:10.1021/nl2014982 · Cited by 253
Design guidelines for optical resonator biochemical sensors
Hu, J., Sun, X., Agarwal, A., & Kimerling, L. C. (2009) · Journal of the Optical Society of America B · doi:10.1364/josab.26.001032 · Cited by 193
“We show that resonant peak fitting is a powerful tool to improve the sensor wavelength resolution to well below the resonant peak FWHM, in a way similar to computer algorithms for commercial SPR systems that calculate the exact position of the SPR peak minimum to a fraction of a single diode size [15].”
MethodBunker, A., Magarkar, A., & Viitala, T. (2016) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2016.02.025 · Cited by 190
Nanophotonic biosensors harnessing van der Waals materials
Oh, S.-H., Altug, H., Jin, X., Low, T., Koester, S. J., Ivanov, A. P., Edel, J. B., Avouris, P., & Strano, M. S. (2021) · Nature Communications · doi:10.1038/s41467-021-23564-4 · Cited by 165
Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities
Blair, S., & Chen, Y. (2001) · Applied Optics · doi:10.1364/ao.40.000570 · Cited by 159
Thermal independent Silicon-Nitride slot waveguide biosensor with high sensitivity
Tu, X., Song, J., Liow, T.-Y., Park, M. K., Yiying, J. Q., Kee, J. S., Yu, M., & Lo, G.-Q. (2012) · Optics Express · doi:10.1364/oe.20.002640 · Cited by 121
Metadata
- Authors
- Liedberg, B., Nylander, C., & Lundström, I.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 10
- Issue
- 8
- Pages
- i-ix
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1995687609
- Cited by
- 684
- References
- 17
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.