Collisional activation and collision-activated dissociation of large multiply charged polypeptides and proteins produced by electrospray ionization
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Collisional activation (CA) and collision-activated dissociation (CAD) of multiply protonated molecular ions produced by electrospray ionization using an atmospheric pressure source are described. A TAGA 6000E triple-quadrupole mass spectrometer, in both unmodified and differentially pumped inlet arrangements, was used to investigate CA and CAD during transfer through the atmosphere-vacuum interface and subsequent CAD in the tandem instrument. Melittin, which has a molecular weight (M r ) of 2846, is efficiently dissociated in the interface at higher nozzle-skimmer voltages, yielding fragmentation that can be assigned to the various charge states. Selection of such product ions formed in the interface for subsequent tandem mass spectrometry allows confirmation of earlier sequence assignments and extends the utility of these methods. Various charge states of larger polypeptides, such as human parathyroid hormone (1-44) (M r 5064), can be efficiently collisionally dissociated in the second (rf-only) quadrupole. However, for molecular ions of this size, the low-energy collisions used for CAD yield only partial sequence information. For large molecules such as horse heart myoglobin (M r 16,951), the effects of nozzle-skimmer bias are explored, and it is shown that higher charge states (at ≤ m/z 1400) can be effectively dissociated in the interface. Initial results for both metastable (unimolecular) and CAD for myoglobin are reported. The potential and limitations of CAD for large biomolecular ions are discussed. The feasibility of fingerprinting for proteins is illustrated by the CAD spectra of cytochrome c from nine species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Protein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180
Contributions of mass spectrometry to peptide and protein structure
Biemann, K. (1988) · Biological Mass Spectrometry · doi:10.1002/bms.1200160119 · Cited by 1,015
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Self-citationCovey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Collision-induced fragmentation of (M + H)+ ions of peptides. Side chain specific sequence ions
Johnson, R. S., Martin, S. A., & BIEMANN, K. (1988) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(88)80060-0 · Cited by 535
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
Self-citationMultiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nguyen, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393
Self-citationLoo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
Self-citation
Cited by
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Self-citationBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
The interpretation of collision‐induced dissociation tandem mass spectra of peptides
Papayannopoulos, I. A. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140104 · Cited by 657
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Self-citation[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Self-citationCollision‐Induced Dissociation (CID) of Peptides and Proteins
(2005) · Methods in Enzymology · doi:10.1016/s0076-6879(05)02005-7 · Cited by 482
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Huddleston, M. J., Bean, M. F., & Carr, S. A. (1993) · Analytical Chemistry · doi:10.1021/ac00055a009 · Cited by 395
Weighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Self-citation‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.0.co;2-j · Cited by 233
Gas-phase ions of solute species from charged droplets of solutions
Nguyen, S., & Fenn, J. B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609969104 · Cited by 232
Niessen, W. M. A. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01112-6 · Cited by 206
McCormack, A. L., Somogyi, A., Dongre, A. R., & Wysocki, V. H. (1993) · Analytical Chemistry · doi:10.1021/ac00068a024 · Cited by 202
High-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Small volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Self-citationControlling Charge States of Large Ions
Scalf, M., Westphall, M. S., Krause, J., Kaufman, S. L., & Smith, L. M. (1999) · Science · doi:10.1126/science.283.5399.194 · Cited by 168
New reagents for increasing ESI multiple charging of proteins and protein complexes
Lomeli, S. H., Peng, I. X., Yin, S., Ogorzalek Loo, R. R., & Loo, J. A. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.09.014 · Cited by 162
Lane, W. S., Galat, A., Harding, M. W., & Schreiber, S. L. (1991) · Journal of Protein Chemistry · doi:10.1007/bf01024778 · Cited by 159
Fragmentation of Integral Membrane Proteins in the Gas Phase
Skinner, O. S., Catherman, A. D., Early, B. P., Thomas, P. M., Compton, P. D., & Kelleher, N. L. (2014) · Analytical Chemistry · doi:10.1021/ac500864w · Cited by 29
Metadata
- Authors
- Smith, R. D., Loa, J. A., Barinaga, C. J., Edmonds, C. G., & Udseth, H. R.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-02-01
- Volume
- 1
- Issue
- 1
- Pages
- 53-65
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2089726908
- Cited by
- 244
- References
- 15
- FWCI
- 21.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.