Structural determination of picomole amounts of phospholipids via electrospray ionization tandem mass spectrometry
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The remarkable sensitivity of electrospray ionization was exploited to achieve great increases in the sensitivity of tandem mass spectrometric analyses of phospholipids derived from both synthetic and biologic sources. Herein, we demonstrate that (1) product-ion spectra after electrospray ionization can be obtained easily by utilizing ≤ 5 pmol of phospholipid with a mass-selected window of less than 2 mass units, (2) the low energy inherent in the electrospray ionization method facilitates analysis of labile molecular ions that are not easily detected with the relatively high energy employed during fast-atom bombardment desorption, and (3) collision-induced dissociation of precursor ions generated from electrospray ionization often resulted in novel product-ion patterns. Collectively, these results underscore the utility of electrospray ionization tandem mass spectroscopy for the structural determination of diminutive amounts of phospholipids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patton, G. M., Fasulo, J. M., & Robins, S. J. (1982) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38188-8 · Cited by 534
Han, X., & Gross, R. W. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.22.10635 · Cited by 435
Self-citationKerwin, J. L., Tuininga, A. R., & Ericsson, L. H. (1994) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)40106-3 · Cited by 323
Gross, R. W. (1984) · Biochemistry · doi:10.1021/bi00296a026 · Cited by 297
Self-citationLiquid Chromatography/Mass Spectrometry of Phospholipids using Electrospray Ionization
Kim, H.-Y., Wang, T.-C. L., & Ma, Y.-C. (1994) · Analytical Chemistry · doi:10.1021/ac00094a020 · Cited by 259
Cole, M. J., & Enke, C. G. (1991) · Analytical Chemistry · doi:10.1021/ac00010a020 · Cited by 141
Murphy, R. C. (1993) · Medical Entomology and Zoology · Cited by 136
Kayganich, K. A., & Murphy, R. C. (1992) · Analytical Chemistry · doi:10.1021/ac00047a015 · Cited by 126
Modulation of canine myocardial sarcolemmal membrane fluidity by amphiphilic compounds.
Fink, K. L., & Gross, R. W. (1984) · Circulation Research · doi:10.1161/01.res.55.5.585 · Cited by 113
Self-citationAyanoĝlu, E., Wegmann, A., Pilet, O., Marbury, G. D., Hass, J. R., & Djerassi, C. (1984) · Journal of the American Chemical Society · doi:10.1021/ja00330a035 · Cited by 81
Cited by
Han, X., & Gross, R. W. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20023 · Cited by 1,106
Self-citationHan, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
“Acyl chain(s) of each individual PE molecular species can be identified either by utilizing product ion ESI tandem MS as previously described ( 36 ) or by employing an efficient two-dimensional fingerprinting technique by ESI tandem mass scanning of all potential acyl carboxylate ions in the precursor ion mode.”
InfluentialSelf-citationBrügger, B., Erben, G., Sandhoff, R., Wieland, F. T., & Lehmann, W. D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.6.2339 · Cited by 881
Han, X., M. Holtzman, D., W. McKeel, D., Kelley, J., & Morris, J. C. (2002) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2002.00997.x · Cited by 626
Self-citationDesorption electrospray ionization mass spectrometry: Imaging drugs and metabolites in tissues
Wiseman, J. M., Ifa, D. R., Zhu, Y., Kissinger, C. B., Manicke, N. E., Kissinger, P. T., & Cooks, R. G. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801066105 · Cited by 460
Koivusalo, M., Haimi, P., Heikinheimo, L., Kostiainen, R., & Somerharju, P. (2001) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)31176-7 · Cited by 417
Yang, K., Cheng, H., Gross, R. W., & Han, X. (2009) · Analytical Chemistry · doi:10.1021/ac900241u · Cited by 415
Self-citationMALDI Imaging of Lipid Biochemistry in Tissues by Mass Spectrometry
Zemski Berry, K. A., Hankin, J. A., Barkley, R. M., Spraggins, J. M., Caprioli, R. M., & Murphy, R. C. (2011) · Chemical Reviews · doi:10.1021/cr200280p · Cited by 386
Advances in Mass Spectrometry for Lipidomics
Blanksby, S. J., & Mitchell, T. W. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073705 · Cited by 366
Han, X., & Gross, R. W. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5178 · Cited by 358
Self-citationHsu, F.-F., & Turk, J. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.02.033 · Cited by 346
Hsu, F.-F., & Turk, J. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00064-3 · Cited by 332
Cutler, R. G., Pedersen, W. A., Camandola, S., Rothstein, J. D., & Mattson, M. P. (2002) · Annals of Neurology · doi:10.1002/ana.10312 · Cited by 323
Wang, M., Wang, C., & Han, X. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21492 · Cited by 301
Self-citationLee, J.-T., Xu, J., Lee, J.-M., Ku, G., Han, X., Yang, D.-I., Chen, S., & Hsu, C. Y. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200307017 · Cited by 280
Self-citationShotgun lipidomics: multidimensional MS analysis of cellular lipidomes
Han, X., & Gross, R. W. (2005) · Expert Review of Proteomics · doi:10.1586/14789450.2.2.253 · Cited by 278
Self-citationThe foundations and development of lipidomics
Han, X., & Gross, R. W. (2022) · Journal of Lipid Research · doi:10.1016/j.jlr.2021.100164 · Cited by 249
“In brief, Gross exploited the power of HPLC and fast atom bombardment-MS and identified plasmalogens as the major phospholipid constituents of sarcolemma (34), sarcoplasmic reticulum, and their presence in mitochondrial membranes (35) of canine ventricular myocardium.”
BackgroundInfluentialSelf-citationHsu, F.-F., Bohrer, A., & Turk, J. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00012-9 · Cited by 219
Han, X., Yang, J., Cheng, H., Ye, H., & Gross, R. W. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.04.004 · Cited by 219
Self-citationSubbanagounder, G., Leitinger, N., Schwenke, D. C., Wong, J. W., Lee, H., Rizza, C., Watson, A. D., Faull, K. F., Fogelman, A. M., & Berliner, J. A. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.10.2248 · Cited by 216
High-throughput shotgun lipidomics by quadrupole time-of-flight mass spectrometry
Ståhlman, M., Ejsing, C. S., Tarasov, K., Perman, J., Borén, J., & Ekroos, K. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.02.037 · Cited by 216
Lipidomics era: Accomplishments and challenges
Bou Khalil, M., Hou, W., Zhou, H., Elisma, F., Swayne, L. A., Blanchard, A. P., Yao, Z., Bennett, S. A. L., & Figeys, D. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20294 · Cited by 204
Lipidomics at the Interface of Structure and Function in Systems Biology
Gross, R. W., & Han, X. (2011) · Chemistry & Biology · doi:10.1016/j.chembiol.2011.01.014 · Cited by 191
“Moreover, the robust increase in signal to noise during ESI readily led to application of tandem mass spectrometric approaches for lipid analysis (Han and Gross, 1995) allowing discrimination of the multiple isobaric and isomeric molecular species present at each m/z value.”
BackgroundSelf-citationHan, X., Yang, K., & Gross, R. W. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3595 · Cited by 190
Self-citationShotgun lipidomics of cardiolipin molecular species in lipid extracts of biological samples
Han, X., Yang, K., Yang, J., Cheng, H., & Gross, R. W. (2006) · Journal of Lipid Research · doi:10.1194/jlr.d500044-jlr200 · Cited by 184
“These ions were confirmed by product ion analyses (spectra not shown), as described previously (23).”
BackgroundSelf-citationGlycerophospholipid Identification and Quantitation by Electrospray Ionization Mass Spectrometry
Ivanova, P. T., Milne, S. B., Byrne, M. O., Xiang, Y., & Brown, H. A. (2007) · Methods in Enzymology · doi:10.1016/s0076-6879(07)32002-8 · Cited by 174
Lipidomics: An analysis of cellular lipids by ESI-MS
Milne, S., Ivanova, P., Forrester, J., & Alex Brown, H. (2006) · Methods · doi:10.1016/j.ymeth.2006.05.014 · Cited by 172
Han, X., Yang, K., Cheng, H., Fikes, K. N., & Gross, R. W. (2005) · Journal of Lipid Research · doi:10.1194/jlr.d500007-jlr200 · Cited by 164
“Therefore, the isobaric species of the ions and the regiospecificity of each molecular species were determined from the presence of multiple cross-peaks and the analysis of intensity ratios of the related cross-peaks, as described previously (33).”
Self-citationGarrett, T. J., Prieto-Conaway, M. C., Kovtoun, V., Bui, H., Izgarian, N., Stafford, G., & Yost, R. A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.019 · Cited by 160
Host Fatty Acid Utilization by Staphylococcus aureus at the Infection Site
Frank, M. W., Yao, J., Batte, J. L., Gullett, J. M., Subramanian, C., Rosch, J. W., & Rock, C. O. (2020) · mBio · doi:10.1128/mbio.00920-20 · Cited by 57
Metadata
- Authors
- Han, X., & Gross, R. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-12-01
- Volume
- 6
- Issue
- 12
- Pages
- 1202-1210
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2006209403
- Cited by
- 289
- References
- 18
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.