Glucose monitoring: state of the art and future possibilities
The DOI matches its Crossref record; 121 of the 121 references it cites were found in a registry or an index.
Abstract
This article reviews the development of glucose monitoring techniques and approaches during the last decade. The predominance of the electrochemical measuring principles reported in the literature makes them a focus of this work. Biosensors are still in the main stream of the research interest of most teams due to their high selectivity for glucose determination. Systematization and classification of the glucose monitoring principles and types of glucose sensors is shown. The review gives a brief description of the basic operational principles of the most popular types of glucose biosensors, providing an enhanced bibliography of the original works of the main groups in establishing or significantly contributing to the development of the particular type of glucose biosensor. Different design approaches are overviewed including needle-type sensors, sensors for chronical implantation and the combination of the glucose biosensors with microdialysis sampling technique. The authors approach for replacing of the spent enzyme and thus recharging the sensor in situ while implanted is widely discussed. This approach provides a way to increase the lifespan of the system and ultimately, it could lead to rare transcutaneous interventions for refilling of the implanted sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,646
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
Diabetes Control and Complications Trial
Yue, D., Colagiuri, S., McElduff, A., & Silink, M. (1993) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1993.tb141357.x · Cited by 575
An enzyme electrode for the amperometric determination of glucose
Guilbault, G. G., & Lubrano, G. J. (1973) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82476-4 · Cited by 571
Weibel, M. K., & Bright, H. J. (1971) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)62246-x · Cited by 349
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Glucose oxidase: natural occurrence, function, properties and industrial applications
Wong, C. M., Wong, K. H., & Chen, X. D. (2008) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-008-1407-4 · Cited by 553
Functional copolymers of N-isopropylacrylamide for bioengineering applications
Rzaev, Z. M. O., Dinçer, S., & Pişkin, E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.01.006 · Cited by 528
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Shoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 343
Current research activity in biosensors
Nakamura, H., & Karube, I. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1947-5 · Cited by 299
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Amperometric glucose biosensor based on single-walled carbon nanohorns
Liu, X., Shi, L., Niu, W., Li, H., & Xu, G. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.016 · Cited by 206
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181
Armistead, P. M., & Thorp, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac000051e · Cited by 180
Marvin, J. S., & Hellinga, H. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972993f · Cited by 179
Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.2005927 · Cited by 179
“5(b), the current flows from WE to CE [6].”
BackgroundInfluentialDudde, R., Vering, T., Piechotta, G., & Hintsche, R. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.864477 · Cited by 47
Metadata
- Authors
- Wilkins, E., & Atanasov, P.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1996-06-01
- Volume
- 18
- Issue
- 4
- Pages
- 273-288
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2022860082
- Cited by
- 180
- References
- 121
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.