CoChat

The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.

Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays

Abstract

A consistent feature of the foreign body response (FBR), irrespective of the type of implant, is persistent inflammation at the biotic-abiotic interface signaled by biomarkers of macrophage/microglial activation. Since macrophage-secreted factors shape the foreign body reaction, implant designs that reduce macrophage activation should improve biocompatibility and, with regard to recording devices, should improve reliability and longevity. At present, it is unclear whether the goal of seamless integration is possible or whether electrode developers can modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. To explore this area, we studied the chronic brain FBR to planar solid silicon microelectrode arrays and planar lattice arrays with identical penetrating profiles but with reduced surface area in rats after an 8-week indwelling period. Using quantitative immunohistochemistry, we found that presenting less surface area after equivalent iatrogenic injury is accompanied by significantly less persistent macrophage activation, decreased blood brain barrier leakiness, and reduced neuronal cell loss. Our findings show that it is possible for implant developers to modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. Our results also support the theory that the FBR to implanted electrode arrays, and likely other implants, can be explained by the presence of macrophages at…

Overview

Integrity signals

Registry

Crossref · 10.1016/b978-0-444-53815-4.00009-1

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 51 references

Cited by

See all 115

Metadata

Authors
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A.
Affiliations
  • University of Utah (US)
  • University of Michigan (US)
Corresponding author
Tresco, Patrick A.
Venue
Progress in Brain Research
Publisher
Elsevier
Published
2011
Volume
194
Pages
167-180
ISSN
0079-6123 (ISSN-L)
OpenAlex
W1562315735
Cited by
111
References
52
Citations by year
2025: 3 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 6 · 2019: 6 · 2018: 11 · 2017: 11 · 2016: 6 · 2015: 12 · 2014: 16 · 2013: 9 · 2012: 7
FWCI
10.28
Type
book chapter
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Progress in brain research (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke (R01 NS0467700)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
foreign body reaction, silicon microelectrodes, macrophage activation, microglial activation, biocompatibility, neuronal loss, chronic implantation, electrode design, neuroinflammation
MeSH terms
Animals, Biocompatible Materials, Blood-Brain Barrier, Brain, Electrodes, Implanted, Foreign-Body Reaction, Humans, Microelectrodes, Neurons, Surface Properties, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. https://app.cochat.ai/papers/10.1016/b978-0-444-53815-4.00009-1
The paper
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011). Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. Progress in Brain Research. https://doi.org/10.1016/b978-0-444-53815-4.00009-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.