The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays
Abstract
A consistent feature of the foreign body response (FBR), irrespective of the type of implant, is persistent inflammation at the biotic-abiotic interface signaled by biomarkers of macrophage/microglial activation. Since macrophage-secreted factors shape the foreign body reaction, implant designs that reduce macrophage activation should improve biocompatibility and, with regard to recording devices, should improve reliability and longevity. At present, it is unclear whether the goal of seamless integration is possible or whether electrode developers can modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. To explore this area, we studied the chronic brain FBR to planar solid silicon microelectrode arrays and planar lattice arrays with identical penetrating profiles but with reduced surface area in rats after an 8-week indwelling period. Using quantitative immunohistochemistry, we found that presenting less surface area after equivalent iatrogenic injury is accompanied by significantly less persistent macrophage activation, decreased blood brain barrier leakiness, and reduced neuronal cell loss. Our findings show that it is possible for implant developers to modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. Our results also support the theory that the FBR to implanted electrode arrays, and likely other implants, can be explained by the presence of macrophages at…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The microscale geometries presented in (A-C) are each associated with an improved tissue response to the implant.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [70]
In the citing paper
“Skousen et al. found that neuronal loss was mitigated surrounding a lattice silicon neural probe featuring reduced surface area in comparison to a conventional, single shank silicon electrode implanted in the rat cerebral cortex (Fig. 3B).70”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [70]
Citations
Cites
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676 · cited 1×
“proinflammatory and cytoxic cytokines such as IL-1B, IL-6, and TNF-a (Block et al., 2007; Cammer, 2000; Chao et al., 1995; Hanisch and Kettenmann, 2007; Quagliarello et al., 1991).”
BackgroundNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Numerous studies have shown that using implanted microelectrode arrays, consciously modulated neural signals can be recorded in both animal subjects as well as human patients for periods of time ranging from months to multiple years, and that these recorded signals can be used to control a number of external devices (…”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 6×
“A key feature of the FBR is persistent inflammation at the biotic–abiotic interface signaled by biomarkers for activated microglia and macrophages (Biran et al., 2005; Stensaas and Stensaas 1976; Winslow and Tresco, 2010; Winslow et al., 2010).”
BackgroundMethodResultSelf-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796 · cited 4×
“The relative intensity and spatial distribution of GFAP immunoreactivity were similar to that seen with other types of devices implanted in the CNS (Biran et al., 2005, 2007; Collias and Manuelidis, 1957; Edell et al., 1992; Schmidt et al., 1993; Schultz and Willey, 1976; Stensaas and Stensaas, 1976, 1978; Szarowski e…”
BackgroundInfluentialChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 1×
“In this study, we observed a similar pattern of inflammation 8 weeks after implantation, a time point when recording inconsistency has been reported (Liu et al., 1999, 2006; Ludwig et al., 2006; Rennaker et al., 2005, 2007).”
MethodFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479 · cited 5×
“The relative intensity and spatial distribution of GFAP immunoreactivity were similar to that seen with other types of devices implanted in the CNS (Biran et al., 2005, 2007; Collias and Manuelidis, 1957; Edell et al., 1992; Schmidt et al., 1993; Schultz and Willey, 1976; Stensaas and Stensaas, 1976, 1978; Szarowski e…”
BackgroundResultInfluentialNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · cited 6×
“Seymour and Kipke found significant differences in the neuronal and nonneuronal cell response between a parylene-based electrode’s larger shank and an adjoining thin lateral platform connected to the main shaft (Seymour and Kipke, 2007), while both Stice et al.”
BackgroundResultInfluential
Cited by
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“In addition to enhanced flexibility, reducing device dimensions may diminish gliosis 48,179,180 by presenting an adhesive surface that is too small to allow cellular attachment 181–185 .”
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(78, 117) These findings suggest that an altered local ionic milieu could influence recording instability.”
BackgroundInfluentialSelf-citationPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Metadata
- Authors
- Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A.
- Affiliations
- University of Utah (US)
- University of Michigan (US)
- Corresponding author
- Tresco, Patrick A.
- ORCID
- Skousen, John L.
- Venue
- Progress in Brain Research
- Publisher
- Elsevier
- Published
- 2011
- Volume
- 194
- Pages
- 167-180
- ISSN
- 0079-6123 (ISSN-L)
- OpenAlex
- W1562315735
- Cited by
- 111
- References
- 52
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 6 · 2019: 6 · 2018: 11 · 2017: 11 · 2016: 6 · 2015: 12 · 2014: 16 · 2013: 9 · 2012: 7
- FWCI
- 10.28
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Progress in brain research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R01 NS0467700)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- foreign body reaction, silicon microelectrodes, macrophage activation, microglial activation, biocompatibility, neuronal loss, chronic implantation, electrode design, neuroinflammation
- MeSH terms
- Animals, Biocompatible Materials, Blood-Brain Barrier, Brain, Electrodes, Implanted, Foreign-Body Reaction, Humans, Microelectrodes, Neurons, Surface Properties, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. https://app.cochat.ai/papers/10.1016/b978-0-444-53815-4.00009-1
- The paper
- Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011). Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. Progress in Brain Research. https://doi.org/10.1016/b978-0-444-53815-4.00009-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.