Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays
The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
A consistent feature of the foreign body response (FBR), irrespective of the type of implant, is persistent inflammation at the biotic-abiotic interface signaled by biomarkers of macrophage/microglial activation. Since macrophage-secreted factors shape the foreign body reaction, implant designs that reduce macrophage activation should improve biocompatibility and, with regard to recording devices, should improve reliability and longevity. At present, it is unclear whether the goal of seamless integration is possible or whether electrode developers can modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. To explore this area, we studied the chronic brain FBR to planar solid silicon microelectrode arrays and planar lattice arrays with identical penetrating profiles but with reduced surface area in rats after an 8-week indwelling period. Using quantitative immunohistochemistry, we found that presenting less surface area after equivalent iatrogenic injury is accompanied by significantly less persistent macrophage activation, decreased blood brain barrier leakiness, and reduced neuronal cell loss. Our findings show that it is possible for implant developers to modulate specific aspects of the FBR by intentionally manipulating the constitutive properties of the implant. Our results also support the theory that the FBR to implanted electrode arrays, and likely other implants, can be explained by the presence of macrophages at…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The microscale geometries presented in (A-C) are each associated with an improved tissue response to the implant.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [70]
In the citing paper
“Skousen et al. found that neuronal loss was mitigated surrounding a lattice silicon neural probe featuring reduced surface area in comparison to a conventional, single shank silicon electrode implanted in the rat cerebral cortex (Fig. 3B).70”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [70]
Citations
Cites
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676 · cited 1×
“proinflammatory and cytoxic cytokines such as IL-1B, IL-6, and TNF-a (Block et al., 2007; Cammer, 2000; Chao et al., 1995; Hanisch and Kettenmann, 2007; Quagliarello et al., 1991).”
BackgroundNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Numerous studies have shown that using implanted microelectrode arrays, consciously modulated neural signals can be recorded in both animal subjects as well as human patients for periods of time ranging from months to multiple years, and that these recorded signals can be used to control a number of external devices (…”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 6×
“A key feature of the FBR is persistent inflammation at the biotic–abiotic interface signaled by biomarkers for activated microglia and macrophages (Biran et al., 2005; Stensaas and Stensaas 1976; Winslow and Tresco, 2010; Winslow et al., 2010).”
BackgroundMethodResultSelf-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796 · cited 4×
“The relative intensity and spatial distribution of GFAP immunoreactivity were similar to that seen with other types of devices implanted in the CNS (Biran et al., 2005, 2007; Collias and Manuelidis, 1957; Edell et al., 1992; Schmidt et al., 1993; Schultz and Willey, 1976; Stensaas and Stensaas, 1976, 1978; Szarowski e…”
BackgroundInfluentialChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 1×
“In this study, we observed a similar pattern of inflammation 8 weeks after implantation, a time point when recording inconsistency has been reported (Liu et al., 1999, 2006; Ludwig et al., 2006; Rennaker et al., 2005, 2007).”
MethodFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479 · cited 5×
“The relative intensity and spatial distribution of GFAP immunoreactivity were similar to that seen with other types of devices implanted in the CNS (Biran et al., 2005, 2007; Collias and Manuelidis, 1957; Edell et al., 1992; Schmidt et al., 1993; Schultz and Willey, 1976; Stensaas and Stensaas, 1976, 1978; Szarowski e…”
BackgroundResultInfluentialNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · cited 6×
“Seymour and Kipke found significant differences in the neuronal and nonneuronal cell response between a parylene-based electrode’s larger shank and an adjoining thin lateral platform connected to the main shaft (Seymour and Kipke, 2007), while both Stice et al.”
BackgroundResultInfluential
Cited by
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“In addition to enhanced flexibility, reducing device dimensions may diminish gliosis 48,179,180 by presenting an adhesive surface that is too small to allow cellular attachment 181–185 .”
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(78, 117) These findings suggest that an altered local ionic milieu could influence recording instability.”
BackgroundInfluentialSelf-citationPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
“In addition, Skousen et al have suggested that macrophage-secreted soluble factors may be critical in both propagating as well as shaping the response to traditional microelectrode designs [31].”
BackgroundSelf-citationPotter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 239
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216
Self-citationKozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
“Furthermore, ultra-small microelectrodes with sub-cellular feature sizes have shown reduced reactive tissue response [26,27,116,117].”
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Spencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 181
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
“Besides the obvious benefit of reduced invasiveness, one proposed mechanism for size being an important factor is that smaller surface area leads to reduced inflammatory cell and molecule accumulation [14,24].”
BackgroundTakmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Biomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Nolta, N. F., Christensen, M. B., Crane, P. D., Skousen, J. L., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.081 · Cited by 175
Self-citationPatel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 161
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
“…electrodes discovered that reducing the diameter of microwires or the width of silicon microelectrodes from 50 – 75 μm to 15 μm induced a significant reduction (p<0.05) in neuronal cell death and glial scarring in rodents (Karumbaiah et al., 2013; Schouenborg et al., 2011; Seymour and Kipke, 2007).”
BackgroundInfluentialIn Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating
Alba, N., Du, Z., Catt, K., Kozai, T., & Cui, X. (2015) · Biosensors · doi:10.3390/bios5040618 · Cited by 137
“improving electrical characteristics [28], reducing tissue reactivity through changes to electrode geometry [23,29–31], flexibility [23,31–38], and surface properties [39], employing biomaterial strategies to promote tissue stability [23,40–43], and incorporating drug release systems to introduce”
BackgroundKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
“Experimental evidence has shown improved recording quality and histology when probe volume and surface area is drastically reduced [68,125,126].”
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Self-citationClinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Potter, K. A., Buck, A. C., Self, W. K., Callanan, M. E., Sunil, S., & Capadona, J. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.035 · Cited by 129
Potter, K. A., Jorfi, M., Householder, K. T., Foster, E. J., Weder, C., & Capadona, J. R. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.01.018 · Cited by 137
“Many factors can contribute to the perpetual disruption of the BBB, including (i) reactive microglia released pro-inflammatory molecules and reactive oxygen species in response to implanted microelectrodes [6,10,14,15] and (ii) the mechanical contrast between ‘‘stiff’’ microelectrodes and ‘‘soft’’ brain tissue, result…”
BackgroundNanoNeuroRFID: A Wireless Implantable Device Based on Magnetoelectric Antennas
Zaeimbashi, M., Lin, H., Dong, C., Liang, X., Nasrollahpour, M., Chen, H., Sun, N., Matyushov, A. D., He, Y., Wang, X., et al. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2903930 · Cited by 125
“related to bio-compatibility and insulation of high density conductive wires [1], [2].”
BackgroundThe future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
“In the first study, lattice probes were compared to solid probes of the same dimension and materials [34].”
Ravikumar, M., Sunil, S., Black, J., Barkauskas, D. S., Haung, A. Y., Miller, R. H., Selkirk, S. M., & Capadona, J. R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.05.084 · Cited by 95
“sults in a persistent inflammatory stimulus and continued BBB disruption [61].”
BackgroundBianchi, M., Salvo, A. D., Asplund, M., Carli, S., Lauro, M. D., Schulze‐Bonhage, A., Stieglitz, T., Fadiga, L., & Biscarini, F. (2022) · Advanced Science · doi:10.1002/advs.202104701 · Cited by 100
Neuroprosthetic technology for individuals with spinal cord injury
Collinger, J. L., Foldes, S. T., Bruns, T. M., Wodlinger, B., Gaunt, R. A., & Weber, D. J. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000128 · Cited by 101
Drug Delivery Interfaces in the 21st Century: From Science Fiction Ideas to Viable Technologies
Chertok, B., Webber, M. J., Succi, M. D., & Langer, R. (2013) · Molecular Pharmaceutics · doi:10.1021/mp4003283 · Cited by 100
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Martin, D. C. (2015) · MRS Communications · doi:10.1557/mrc.2015.17 · Cited by 83
The “sewing machine” for minimally invasive neural recording
Hanson, T. L., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 66
“Improvements in areas 1-3 serve to collectively reduce the foreign body response (FBR); numerous studies have demonstrated that an electrode elicits a strong FBR when implanted in the brain [1],[2],[3],[4].”
BackgroundDu, Z. J., Luo, X., Weaver, C. L., & Cui, X. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00145e · Cited by 76
Potter, K. A., Simon, J. S., Velagapudi, B., & Capadona, J. R. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.024 · Cited by 75
“Due to the immune-privileged nature of the brain, the presence of blood-derived immunoglobulins, such as IgG, have only been reported to appear diffusely in tissue as a result of BBB leakiness at the device–tissue interface, and was thus an ideal marker for protocol validation (Aihara et al., 1994; Abbott et al., 2006…”
BackgroundRegenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
“70 Next-generation devices fabricated from parylene-insulated carbon fibers with anti-biofouling poly(ethylene glycol) methacrylate coatings have demonstrated robust recording quality and a minimal accompanying tissue response (Fig.”
Subcellular Neural Probes from Single-Crystal Gold Nanowires
Kang, M., Jung, S., Zhang, H., Kang, T., Kang, H., Yoo, Y., Hong, J.-P., Ahn, J.-P., Kwak, J., Jeon, D., et al. (2014) · ACS Nano · doi:10.1021/nn5024522 · Cited by 65
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 72
“Astrocytes can be identified by increased expression of glial fibrillary acidic protein (GFAP) and vimentin [93,94].”
BackgroundInfluence of resveratrol release on the tissue response to mechanically adaptive cortical implants
Nguyen, J. K., Jorfi, M., Buchanan, K. L., Park, D. J., Foster, E. J., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.001 · Cited by 69
“Specifically, examination of the tissue response surrounding implanted microwire and Michigan-style microelectrodes revealed that the BBB integrity immediately surrounding the implantation site was compromised [52,53].”
Cassar, I. R., Yu, C., Sambangi, J., Lee, C. D., Whalen, J. J., Petrossians, A., & Grill, W. M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.017 · Cited by 66
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Self-citationPharmacological Mitigation of Tissue Damage during Brain Microdialysis
Nesbitt, K. M., Jaquins‐Gerstl, A., Skoda, E. M., Wipf, P., & Michael, A. C. (2013) · Analytical Chemistry · doi:10.1021/ac401201x · Cited by 61
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
“is that the FBR is due to the persistence of activated macrophages and subsequent release of neurotoxic biomolecules; the larger surface area causes concentration elevations proximal to the biotic–abiotic interface (45).”
Host response to microgel coatings on neural electrodes implanted in the brain
Gutowski, S. M., Templeman, K. L., South, A. B., Gaulding, J. C., Shoemaker, J. T., LaPlaca, M. C., Bellamkonda, R. V., Lyon, L. A., & García, A. J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34799 · Cited by 57
“Long-term inflammation and microglial activation contribute to the foreign body response and failure of electrodes implanted for chronic time points.(39) Reduction of the inflammatory response can be achieved by releasing anti-inflammatory agents at the most beneficial time point, where specific drugs are targeted to…”
Chatard, C., Sabac, A., Velasquez, L. M., Meiller, A., & Marinesco, S. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00797 · Cited by 58
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Potter-Baker, K. A., Nguyen, J. K., Kovach, K. M., Gitomer, M. M., Srail, T. W., Stewart, W. G., Skousen, J. L., & Capadona, J. R. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00125g · Cited by 54
Self-citationWark, H. A. C., Mathews, K. S., Normann, R. A., & Fernandez, E. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046027 · Cited by 54
Autotaxin and lysophospholipids in rheumatoid arthritis.
Bourgoin, S. G., & Zhao, C. (2010) · PubMed · Cited by 59
Christensen, M. B., Wark, H. A. C., & Hutchinson, D. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.012 · Cited by 49
Sommakia, S., Lee, H. C., Gaire, J., & Otto, K. J. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.005 · Cited by 47
“acute phase of the reactive tissue response, including the neuronal kill zone [10,155,146,158].”
BackgroundEreifej, E. S., Smith, C. S., Meade, S. M., Chen, K., Feng, H., & Capadona, J. R. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201704420 · Cited by 52
Ravikumar, M., Hageman, D. J., Tomaszewski, W. H., Chandra, G. M., Skousen, J. L., & Capadona, J. R. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21453b · Cited by 45
Self-citationOakes, R. S., Polei, M. D., Skousen, J. L., & Tresco, P. A. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.001 · Cited by 49
Self-citationBiohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 44
Integration of High-Charge-Injection-Capacity Electrodes onto Polymer Softening Neural Interfaces
Arreaga-Salas, D. E., Avendaño-Bolívar, A., Simon, D., Reit, R., Garcia-Sandoval, A., Rennaker, R. L., & Voit, W. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08139 · Cited by 41
Lee, H. C., Gaire, J., Currlin, S., McDermott, M. D., Park, K., & Otto, K. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00513 · Cited by 45
“Vascular damage is a probable suspect for this variability, as devices that sever large vasculature are reported to cause severe neuro-inflammation (Skousen et al., 2011; Saxena et al., 2013).”
BackgroundMicroelectrode Biosensors for in vivo Analysis of Brain Interstitial Fluid
Chatard, C., Meiller, A., & Marinesco, S. (2018) · Electroanalysis · doi:10.1002/elan.201700836 · Cited by 35
Ghazavi, A., Maeng, J., Black, M., Salvi, S., & Cogan, S. F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab52ab · Cited by 36
“If the expectation that ultra-small shanks (⩽15 μm in two dimensions) induce minimal foreign body response (Seymour and Kipke 2007, Stice et al 2007, Skousen et al 2011) is realized and viable neural cells are in close proximity to the electrode site (Seymour and Kipke 2007), then we might expect…”
BackgroundPerna, A., Angotzi, G. N., Berdondini, L., & Ribeiro, J. F. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1275908 · Cited by 38
Differences Exist in the Left and Right Sciatic Nerves of Naïve Rats and Cats
Christensen, M. B., & Tresco, P. A. (2015) · The Anatomical Record · doi:10.1002/ar.23161 · Cited by 32
“To reduce the number of inflammatory cells, an effort should be made to reduce the surface area of the implanted device (Seymour and Kipke, 2007; Skousen et al., 2011).”
BackgroundSelf-citationUnderstanding the Role of Innate Immunity in the Response to Intracortical Microelectrodes
Hermann, J. K., & Capadona, J. R. (2018) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2018027166 · Cited by 31
Nano functional neural interfaces
Wang, Y., Zhu, H., Yang, H., Argall, A. D., Luan, L., Xie, C., & Guo, L. (2018) · Nano Research · doi:10.1007/s12274-018-2127-4 · Cited by 31
Sharpened and Mechanically Durable Carbon Fiber Electrode Arrays for Neural Recording
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3082056 · Cited by 30
Multiple Implants Do Not Aggravate the Tissue Reaction in Rat Brain
Lind, G., Gällentoft, L., Danielsen, N., Schouenborg, J., & Pettersson, L. M. E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047509 · Cited by 28
“The tissue reactions surrounding different types of neural implants have been extensively studied with regards to size [12,13], shape [10,14,15,16], surface structure and material [17,18,19,20], fixation mode [13,21] and implantation method [14,22].”
BackgroundCurrent Challenges to the Clinical Translation of Brain Machine Interface Technology
Lu, C. W., Patil, P. G., & Chestek, C. A. (2012) · International review of neurobiology · doi:10.1016/b978-0-12-404706-8.00008-5 · Cited by 26
“Microwire designs (Lehew & Nicolelis, 2008) may be important in future clinical systems, as very small microwires (<25 mm) elicit minimal immune response from the brain (Kozai et al., 2010; Seymour & Kipke, 2007; Skousen et al., 2011).”
Placing Sites on the Edge of Planar Silicon Microelectrodes Enhances Chronic Recording Functionality
Lee, H. C., Gaire, J., Roysam, B., & Otto, K. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715811 · Cited by 23
“8(A) and [37], [53]).”
BackgroundBecerra-Fajardo, L., Schmidbauer, M., & Ivorra, A. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2623483 · Cited by 22
Resorbable elastomers for implantable medical devices: highlights and applications
Turner, B. L., Ramesh, S., Menegatti, S., & Daniele, M. A.-A. (2021) · Polymer International · doi:10.1002/pi.6349 · Cited by 20
Quantitative simulation of extracellular single unit recording from the surface of cortex
Hill, M., Rios, E., Sudhakar, S., Roossien, D. H., Caldwell, C. M., Cai, D., Ahmed, O. J., Lempka, S. F., & Chestek, C. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aacdb8 · Cited by 22
Schouenborg, J. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00017-0 · Cited by 19
Cellular-scale silicon probes for high-density, precisely localized neurophysiology
Egert, D., Pettibone, J. R., Lemke, S. M., Patel, P. R., Caldwell, C. M., Cai, D., Ganguly, K., Chestek, C. A., & Berke, J. D. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00352.2020 · Cited by 18
CMOS-Compatible, Flexible, Intracortical Neural Probes
Barz, F., Trouillet, V., Paul, O., & Ruther, P. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2936740 · Cited by 16
“vice dimensions are critical in view of the biocompatibility of an implant [6], [7], active probes with geometric properties untied from their channel count, gain a considerable advantage over”
BackgroundFailure Modes of Implanted Neural Interfaces
Delbeke, J., Haesler, S., & Prodanov, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_6 · Cited by 17
Effects of geometry and material on the insertion oi very small neural electrode
Marshall, S. P., Lin, W.-C., Patel, P. R., Shih, A. J., & Chestek, C. A. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591308 · Cited by 18
“Recently, multiple groups have demonstrated minimal scar tissue around electrodes that are less than 15 μm in diameter [5, 6, 7].”
BackgroundJeakle, E. N., Abbott, J., Usoro, J. O., Wu, Y., Haghighi, P., Radhakrishna, R., Sturgill, B. S., Nakajima, S., Thai, T. T. D., Pancrazio, J. J., et al. (2023) · Micromachines · doi:10.3390/mi14030680 · Cited by 16
“This may be explained, at least in part, by the small cro s-sectional area of ultra-thin a-SiC MEAs, which can minimize the foreign body response, improving neuronal survivability [29].”
BackgroundMueller, N. N., Ocoko, M. Y. M., Kim, Y., Li, K., Gisser, K., Glusauskas, G., Lugo, I., Dernelle, P., Hermoso, A. C., Wang, J., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00440-5 · Cited by 15
“Additionally, activated microglia and macrophages recruited to the implant site release pro-in fl ammatory and cytotoxic soluble factors, such as reactive oxygen species 31 – 36 .”
Implementing tissue engineering and regenerative medicine solutions in medical implants
Ye, D., & Peramo, A. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt036 · Cited by 15
Distributed Neural Interfaces: Challenges and Trends in Scaling Implantable Technology
Szostak, K. M., Feng, P., Mazza, F., & Constandinou, T. G. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_11-1 · Cited by 15
${\mbi{\mu }}$-Foil Polymer Electrode Array for Intracortical Neural Recordings
Ejserholm, F., Köhler, P., Granmo, M., Schouenborg, J., Bengtsson, M., & Wallman, L. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2326859 · Cited by 14
Jung, W., Heo, C., Kim, J. U., Jeong, C., Ryu, H., Park, B., Suh, M., & Kim, T. (2021) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/abdb78 · Cited by 11
Atkinson, E. W., Kuliasha, C. A., Kasper, M., Furniturewalla, A., Lim, A. S., Jiracek-Sapieha, L., Brake, A., Gormaley, A., Rivera-Llabres, V. G., Singh, I., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8bfe · Cited by 11
Neural Interfaces Based on Amorphous Silicon Carbide Ultramicroelectrode Arrays
Deku, F., Ghazavi, A., & Cogan, S. F. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0006 · Cited by 11
Long-term implantable flexible neural interfaces for electrophysiological monitoring
Chen, B., Lu, J., Chen, Z., Han, X., Sun, Y., Lin, X., Tang, Z., Jia, S., Xie, G., Huo, F., et al. (2025) · Journal of Materials Chemistry C · doi:10.1039/d4tc04289a · Cited by 10
Huang, S.-H., Shmoel, N., Jankowski, M. M., Erez, H., Sharon, A., Abu-Salah, W., Nelken, I., Weiss, A. M., & Spira, M. E. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00926 · Cited by 12
Experience and safety of intraoperative Neuropixels: a case series of 56 patients
Chung, J. E., Xu, D., Greicius, Q., Poddar, T., Leonard, M. K., Sellers, K. K., Andrews, J. P., Welkenhuysen, M., Dutta, B., Cadwell, C. R., et al. (2025) · Journal of neurosurgery · doi:10.3171/2025.4.jns241162 · Cited by 9
Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes
Richie, J. M., Letner, J. G., McLane-Svoboda, A. K., Huan, Y., Ghaffari, D. H., della Valle, E., Patel, P. R., Chiel, H. J., Pelled, G., Weiland, J. D., et al. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3360866 · Cited by 9
“Reducing electrode substrate size to cellular sizes also leads to lower FBR, even when using stiffer materials [26], [27].”
BackgroundSpencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-12312-8 · Cited by 8
Prospects for a Robust Cortical Recording Interface
Shoffstall, A. J., & Capadona, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00028-0 · Cited by 8
Electrical rejuvenation of chronically implanted macroelectrodes in nonhuman primates
O'Sullivan, K. P., Orazem, M. E., Otto, K. J., Butson, C. R., & Baker, J. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5703 · Cited by 6
“…ETI changes that are chronically affected by the FBR, which includes changes to electrode geometry and pliability, the addition of surface coatings, and the local administration of anti-inflammatory medications (Skousen et al 2011, Cody et al 2018, La Oliva et al 2018, Gori et al 2021, 2022).”
BackgroundRecent advancements in Micro-engineered devices for surface and deep brain animal studies: A review
Bhaskara, S., Sakorikar, T., Chatterjee, S., Kv, S. G., & Pandya, H. J. (2022) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2022.100483 · Cited by 9
The Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation
Saldanha, R. L., Urdaneta, M. E., & Otto, K. J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.712578 · Cited by 6
Electrodes for the Neural Interface
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00020-6 · Cited by 9
Kilias, A., Lee, Y., Froriep, U. P., Sielaff, C., Moser, D., Holzhammer, T., Egert, U., Fang, W., Paul, O., & Ruther, P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac39b7 · Cited by 5
“Next to the overall implant geometry, which should be kept as small as possible (Seymour and Kipke 2007, Skousen et al 2011), the selection of materials directly at the probe-tissue-interface seems to be of particular importance with a preference towards soft materials such as polymers that more…”
Spira, M. E., Erez, H., & Sharon, A. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.807797 · Cited by 6
Distributed Neural Interfaces: Challenges and Trends in Scaling Implantable Technology
Szostak, K. M., Feng, P., Mazza, F., & Constandinou, T. G. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_11 · Cited by 3
Sharpened and mechanically durable carbon fiber electrode arrays for neural interfacingPreprint
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.21.427697 · Cited by 5
“This suggests that ultra-small electrodes may be similarly biocompatible with nerves, as has been shown in the brain [30]–[32].”
Background
Metadata
- Authors
- Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A.
- Affiliations
- University of Utah (US)
- University of Michigan (US)
- Corresponding author
- Tresco, Patrick A.
- ORCID
- Skousen, John L.
- Venue
- Progress in Brain Research
- Publisher
- Elsevier
- Published
- 2011
- Volume
- 194
- Pages
- 167-180
- ISSN
- 0079-6123 (ISSN-L)
- OpenAlex
- W1562315735
- Semantic Scholar
- 6b96d0da5f29de02b81ecfbcb35dcae08c6bd9cb
- Cited by
- 111
- References
- 52
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 6 · 2019: 6 · 2018: 11 · 2017: 11 · 2016: 6 · 2015: 12 · 2014: 16 · 2013: 9 · 2012: 7
- FWCI
- 10.28
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Progress in brain research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R01 NS0467700)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- foreign body reaction, silicon microelectrodes, macrophage activation, microglial activation, biocompatibility, neuronal loss, chronic implantation, electrode design, neuroinflammation
- MeSH terms
- Animals, Biocompatible Materials, Blood-Brain Barrier, Brain, Electrodes, Implanted, Foreign-Body Reaction, Humans, Microelectrodes, Neurons, Surface Properties, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.