The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Additive-manufactured (3D-printed) electrochemical sensors: A critical review
Abstract
Additive manufacturing or three-dimensional (3D)-printing is an emerging technology that has been applied in the development of novel materials and devices for a wide range of applications, including Electrochemistry and Analytical Chemistry areas. This review article focuses on the contributions of 3D-printing technology to the development of electrochemical sensors and complete electrochemical sensing devices. Due to the recent contributions of 3D-printing within this scenario, the aim of this review is to present a guide for new users of 3D-printing technology considering the required features for improved electrochemical sensing using 3D-printed sensors. At the same time, this is a comprehensive review that includes most 3D-printed electrochemical sensors and devices already reported using selective laser melting (SLM) and fused deposition modeling (FDM) 3D-printers. The latter is the most affordable 3D-printing technique and for this reason has been more often applied for the fabrication of electrochemical sensors, also due to commercially-available conductive and non-conductive filaments. Special attention is given to critically discuss the need for the surface treatment of FDM 3D-printed platforms to improve their electrochemical performance. The insertion of biochemical and chemical catalysts on the 3D-printed surfaces are highlighted as well as novel strategies to fabricate filaments containing chemical modifiers within the polymeric matrix. Some examples of complete electrochemical sensing systems obtained by 3D-printing have successfully demonstrated the enormous potential to develop portable devices for on-site applications. The freedom of design enabled by 3D-printing opens many possibilities of forthcoming investigations in the area of analytical electrochemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helical microtubules of graphitic carbon
Iijima, S. (1991) · Nature · doi:10.1038/354056a0 · Cited by 43,098
3D printing of polymer matrix composites: A review and prospective
Wang, X., Jiang, M., Zhou, Z., Gou, J., & Hui, D. (2017) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2016.11.034 · Cited by 3,325
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Highly compressible 3D periodic graphene aerogel microlattices
Zhu, C., Han, T. Y.-J., Duoss, E. B., Golobic, A. M., Kuntz, J. D., Spadaccini, C. M., & Worsley, M. A. (2015) · Nature Communications · doi:10.1038/ncomms7962 · Cited by 1,148
Nanomaterials for biosensing applications: a review
Holzinger, M., Le Goff, A., & Cosnier, S. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00063 · Cited by 1,066
3D-printing technologies for electrochemical applications
Ambrosi, A., & Pumera, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00714c · Cited by 1,040
Chemically modified electrodes
Murray, R. W. (1980) · Accounts of Chemical Research · doi:10.1021/ar50149a002 · Cited by 942
Gnanasekaran, K., Heijmans, T., van Bennekom, S., Woldhuis, H., Wijnia, S., de With, G., & Friedrich, H. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.04.003 · Cited by 594
Fused deposition modelling with ABS–graphene nanocomposites
Dul, S., Fambri, L., & Pegoretti, A. (2016) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2016.03.013 · Cited by 491
3D Printable Graphene Composite
Wei, X., Li, D., Jiang, W., Gu, Z., Wang, X., Zhang, Z., & Sun, Z. (2015) · Scientific Reports · doi:10.1038/srep11181 · Cited by 481
Rodríguez-Panes, A., Claver, J., & Camacho, A. M. (2018) · Materials · doi:10.3390/ma11081333 · Cited by 477
3D Printed Graphene Based Energy Storage Devices
Foster, C. W., Down, M. P., Zhang, Y., Ji, X., Rowley-Neale, S. J., Smith, G. C., Kelly, P. J., & Banks, C. E. (2017) · Scientific Reports · doi:10.1038/srep42233 · Cited by 471
Emerging 3D‐Printed Electrochemical Energy Storage Devices: A Critical Review
Tian, X., Jin, J., Yuan, S., Chua, C. K., Tor, S. B., & Zhou, K. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201700127 · Cited by 407
Complete Additively Manufactured (3D-Printed) Electrochemical Sensing Platform
Richter, E. M., Rocha, D. P., Cardoso, R. M., Keefe, E. M., Foster, C. W., Munoz, R. A. A., & Banks, C. E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02573 · Cited by 338
Self-citationElectrically conductive filament for 3D-printed circuits and sensors
Kwok, S. W., Goh, K. H. H., Tan, Z. D., Tan, S. T. M., Tjiu, W. W., Soh, J. Y., Ng, Z. J. G., Chan, Y. Z., Hui, H. K., & Goh, K. E. J. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.07.001 · Cited by 332
Additive Manufacturing of Batteries
Pang, Y., Cao, Y., Chu, Y., Liu, M., Snyder, K., MacKenzie, D., & Cao, C. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906244 · Cited by 298
3D printing for electroanalysis: From multiuse electrochemical cells to sensors
Cardoso, R. M., Mendonça, D. M. H., Silva, W. P., Silva, M. N. T., Nossol, E., da Silva, R. A. B., Richter, E. M., & Muñoz, R. A. A. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.021 · Cited by 294
Self-citation3D-Printed Graphene/Polylactic Acid Electrodes Promise High Sensitivity in Electroanalysis
Manzanares Palenzuela, C. L., Novotný, F., Krupička, P., Sofer, Z., & Pumera, M. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00083 · Cited by 275
Cardoso, R. M., Silva, P. R. L., Lima, A. P., Rocha, D. P., Oliveira, T. C., do Prado, T. M., Fava, E. L., Fatibello-Filho, O., Richter, E. M., & Muñoz, R. A. A. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127621 · Cited by 231
Self-citationRavi, A. K., Deshpande, A., & Hsu, K. H. (2016) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2016.08.007 · Cited by 217
Helical 3D‐Printed Metal Electrodes as Custom‐Shaped 3D Platform for Electrochemical Devices
Ambrosi, A., Moo, J. G. S., & Pumera, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201503902 · Cited by 214
Three-Dimensional Printed Electrode and Its Novel Applications in Electronic Devices
Foo, C. Y., Lim, H. N., Mahdi, M. A., Wahid, M. H., & Huang, N. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-25861-3 · Cited by 213
Rymansaib, Z., Iravani, P., Emslie, E., Medvidović‐Kosanović, M., Sak‐Bosnar, M., Verdejo, R., & Marken, F. (2016) · Electroanalysis · doi:10.1002/elan.201600017 · Cited by 176
Electrochemical Biosensors Based on Nanostructured Carbon Black: A Review
Silva, T. A., Moraes, F. C., Janegitz, B. C., & Fatibello-Filho, O. (2017) · Journal of Nanomaterials · doi:10.1155/2017/4571614 · Cited by 176
Self-citationRocha, D. P., Squissato, A. L., da Silva, S. M., Richter, E. M., & Munoz, R. A. A. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.135688 · Cited by 174
Self-citationdos Santos, P. L., Katic, V., Loureiro, H. C., dos Santos, M. F., dos Santos, D. P., Formiga, A. L. B., & Bonacin, J. A. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.013 · Cited by 163
Self-citationA review of 3D-printed sensors
Ni, Y., Ji, R., Long, K., Bu, T., Chen, K., & Zhuang, S. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2017.1287082 · Cited by 158
Rapid prototyping of electrically conductive components using 3D printing technology
Czyżewski, J., Burzyński, P., Gaweł, K., & Meisner, J. (2009) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2009.03.015 · Cited by 151
3D-printed flexible device combining sampling and detection of explosives
Cardoso, R. M., Castro, S. V. F., Silva, M. N. T., Lima, A. P. B. M., Santana, M. H. P., Nossol, E., da Silva, R. A. B., Richter, E. M., Paixão, T. R. L. C., & Muñoz, R. A. A. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.04.126 · Cited by 145
Self-citationKatic, V., dos Santos, P. L., dos Santos, M. F., Pires, B. M., Loureiro, H. C., Lima, A. P. B. M., Queiroz, J. C. M., Landers, R., Muñoz, R. A. A., & Bonacin, J. A. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09305 · Cited by 145
Self-citationWirth, D. M., Sheaff, M. J., Waldman, J. V., Symcox, M. P., Whitehead, H. D., Sharp, J. D., Doerfler, J. R., Lamar, A. A., & LeBlanc, G. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01331 · Cited by 142
Self‐Contained Polymer/Metal 3D Printed Electrochemical Platform for Tailored Water Splitting
Ambrosi, A., & Pumera, M. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700655 · Cited by 141
Single-step fabrication of electrochemical flow cells utilizing multi-material 3D printing
O’Neil, G. D., Ahmed, S. S., Halloran, K., Janusz, J. N., Rodríguez, A., & Rodríguez, I. M. T. (2018) · Electrochemistry Communications · doi:10.1016/j.elecom.2018.12.006 · Cited by 141
Biosensors based on gold nanostructures
Vidotti, M., Carvalhal, R. F., Mendes, R. K., Ferreira, D., & Kubota, L. T. (2011) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50532011000100002 · Cited by 140
Manzanares‐Palenzuela, C. L., Hermanová, S., Sofer, Z., & Pumera, M. (2019) · Nanoscale · doi:10.1039/c9nr02754h · Cited by 127
3D Printed Electrodes for Detection of Nitroaromatic Explosives and Nerve Agents
Tan, C., Nasir, M. Z. M., Ambrosi, A., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01614 · Cited by 103
Sang, L., Han, S., Peng, X., Jian, X., & Wang, J. (2019) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2019.105518 · Cited by 102
Cruz, M. A., Ye, S., Kim, M. J., Reyes, C., Yang, F., Flowers, P. F., & Wiley, B. J. (2018) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.201700385 · Cited by 100
3D-printed Ag/AgCl pseudo-reference electrodes
Rohaizad, N., Mayorga‐Martinez, C. C., Novotný, F., Webster, R. D., & Pumera, M. (2019) · Electrochemistry Communications · doi:10.1016/j.elecom.2019.05.010 · Cited by 96
DNA biosensing with 3D printing technology
Loo, A. H., Chua, C. K., & Pumera, M. (2016) · The Analyst · doi:10.1039/c6an02038k · Cited by 94
Honeychurch, K. C., Rymansaib, Z., & Iravani, P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.054 · Cited by 91
Walters, J. G., Ahmed, S. S., Rodríguez, I. M. T., & O’Neil, G. D. (2020) · Electroanalysis · doi:10.1002/elan.201900658 · Cited by 91
Cocovi-Solberg, D. J., Worsfold, P. J., & Miró, M. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.007 · Cited by 90
3D printed polylactic acid/carbon black electrodes with nearly ideal electrochemical behaviour
Vaněčková, E., Bouša, M., Lachmanová, Š. N., Rathouský, J., Gál, M., Sebechlebská, T., & Kolivoška, V. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113745 · Cited by 88
Hughes, J. P., dos Santos, P. L., Down, M. P., Foster, C. W., Bonacin, J. A., Keefe, E. M., Rowley‐Neale, S. J., & Banks, C. E. (2019) · Sustainable Energy & Fuels · doi:10.1039/c9se00679f · Cited by 84
Self-citationCopper electroplating of 3D printed composite electrodes
Vaněčková, E., Bouša, M., Sokolová, R., Moreno‐García, P., Broekmann, P., Shestivská, V., Rathouský, J., Gál, M., Sebechlebská, T., & Kolivoška, V. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113763 · Cited by 63
3D‐printed Electrodes for Sensing of Biologically Active Molecules
Liyarita, B. R., Ambrosi, A., & Pumera, M. (2018) · Electroanalysis · doi:10.1002/elan.201700828 · Cited by 62
João, A. F., Squissato, A. L., Richter, E. M., & Muñoz, R. A. A. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02513-y · Cited by 59
Self-citationUV/VIS spectroelectrochemistry with 3D printed electrodes
Vaněčková, E., Bouša, M., Vivaldi, F. M., Gál, M., Rathouský, J., Kolivoška, V., & Sebechlebská, T. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113760 · Cited by 46
3D-Printed Low-Cost Spectroelectrochemical Cell for In Situ Raman Measurements
dos Santos, M. F., Katic, V., dos Santos, P. L., Pires, B. M., Formiga, A. L. B., & Bonacin, J. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01518 · Cited by 45
Self-citation3D and 4D printing of polymer/CNTs-based conductive composites
Agarwala, S., Goh, G. L., Goh, G. D., Dikshit, V., & Yeong, W. Y. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816805-9.00010-7 · Cited by 44
Additive manufacturing of electrochemical interfaces: Simultaneous detection of biomarkers
Ho, E. H. Z., Ambrosi, A., & Pumera, M. (2018) · Applied Materials Today · doi:10.1016/j.apmt.2018.03.008 · Cited by 40
Jain, S., & Tadesse, Y. T. (2018) · International Journal of Nanoscience · doi:10.1142/s0219581x18500266 · Cited by 33
Mendonça, D. M. H., Rocha, D. P., Dutra, G. S. V., Cardoso, R. M., Batista, A. D., Richter, E. M., & Muñoz, R. A. A. (2019) · Electroanalysis · doi:10.1002/elan.201800834 · Cited by 32
Self-citationSatterthwaite, K. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-35824-8.00012-8 · Cited by 27
Aggarwal, S., Johnson, S., Saloni, D. E., & Hakovirta, M. (2019) · Composites Part B Engineering · doi:10.1016/j.compositesb.2019.107310 · Cited by 27
Guima, K., Souza, V. H. R., & Martins, C. A. (2019) · RSC Advances · doi:10.1039/c9ra01436e · Cited by 22
Cited by
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Additive Manufacturing of Polymer Materials: Progress, Promise and Challenges
Saleh Alghamdi, S., John, S., Roy Choudhury, N., & Dutta, N. K. (2021) · Polymers · doi:10.3390/polym13050753 · Cited by 469
3D printed electronics: Processes, materials and future trends
Tan, H. W., Choong, Y. Y. C., Kuo, C. N., Low, H. Y., & Chua, C. K. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.100945 · Cited by 327
Inkjet Printing and 3D Printing Strategies for Biosensing, Analytical, and Diagnostic Applications
Zub, K., Hoeppener, S., & Schubert, U. S. (2022) · Advanced Materials · doi:10.1002/adma.202105015 · Cited by 287
Metadata
- Authors
- Cardoso, R. M., Kalinke, C., Rocha, R. G., dos Santos, P. L., Rocha, D. P., Oliveira, P. R., Janegitz, B. C., Bonacin, J. A., Richter, E. M., & Munoz, R. A. A.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 1118
- Pages
- 73-91
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W3011515634
- Cited by
- 460
- References
- 57
- FWCI
- 21.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.