Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
The large-scale diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is important for traceability and treatment during pandemic outbreaks. We developed a fast (2–3 min), easy-to-use, low-cost, and quantitative electrochemical biosensor based on carbon nanotube field-effect transistor (CNT-FET) that allows digital detection of the SARS-CoV-2 S1 in fortifited saliva samples for quick and accurate detection of SARS-CoV-2 S1 antigens. The biosensor was developed on a Si/SiO2 surface by CNT printing with the immobilization of a anti-SARS-CoV-2 S1. SARS-CoV-2 S1 antibody was immobilized on the CNT surface between the S-D channel area using a linker 1-pyrenebutanoic acid succinimidyl ester (PBASE) through non-covalent interaction. A commercial SARS-CoV-2 S1 antigen was used to characterize the electrical output of the CNT-FET biosensor. The SARS-CoV-2 S1 antigen in the 10 mM AA buffer pH 6.0 was effectively detected by the CNT-FET biosensor at concentrations from 0.1 fg/mL to 5.0 pg/mL. The limit of detection (LOD) of the developed CNT-FET biosensor was 4.12 fg/mL. The selectivity test was performed by using target SARS-CoV-2 S1 and non-target SARS-CoV-1 S1 and MERS-CoV S1 antigens in the 10 mM AA buffer pH 6.0. The biosensor showed high selectivity (no response to SARS-CoV-1 S1 or MERS-CoV S1 antigen) with SARS-CoV-2 S1 antigen detection in the 10 mM AA buffer pH 6.0. The biosensor is highly sensitive, saves time, and could be a helpful platform for rapid detection of SARS-CoV-2 S1 antigen from the patients saliva.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel coronavirus from patients with pneumonia in China, 2019
Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001017 · Cited by 28,244
Structure, function and antigenicity of the SARS-CoV-2 spike glycoprotein
Walls, A. C., Park, Y.-J., Tortorici, M. A., Wall, A., McGuire, A. T., & Veesler, D. (2020) · doi:10.1101/2020.02.19.956581 · Cited by 8,586
ExPASy: the proteomics server for in-depth protein knowledge and analysis
Gasteiger, E. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg563 · Cited by 5,595
Origin and evolution of pathogenic coronaviruses
Cui, J., Li, F., & Shi, Z.-L. (2019) · Nature Reviews Microbiology · doi:10.1038/s41579-018-0118-9 · Cited by 5,515 · cited 1×
“It is well known that there have been three human pathogenic coronavirus outbreaks in the 21st century that triggered transmission and posed immense challenges to global public health and economic growth [2].”
Ou, X., Liu, Y., Lei, X., Li, P., Mi, D., Ren, L., Guo, L., Guo, R., Chen, T., Hu, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15562-9 · Cited by 3,097
Extreme Oxygen Sensitivity of Electronic Properties of Carbon Nanotubes
Collins, P. G., Bradley, K., Ishigami, M., & Zettl, A. (2000) · Science · doi:10.1126/science.287.5459.1801 · Cited by 2,974 · cited 1×
“Oxygen and water molecules adsorbed on the CNT surface withdraw electrons from the CNT, which results in the p-type operation [30].”
Huang, Y., Yang, C., Xu, X.-F., Xu, W., & Liu, S.-W. (2020) · Acta Pharmacologica Sinica · doi:10.1038/s41401-020-0485-4 · Cited by 2,224 · cited 3×
“Abbreviations: AA, Ammonium acetate; ACE2, Angiotensin-converting enzyme 2; AuNPs, gold nanoparticles; BSA, Bovine serum albumin; CNT, Carbon nanotube; COVID-19, coronavirus disease 2019; EDC, 1-(3-dimethylaminopropyl)-3-ethylcar bodiimide hydrochloride; FET, field-effect transistor; IDS, source-drain current; MERS-Co…”
InfluentialSeo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837 · cited 2×
“1 fg/mL 1 fg/mL to 10 pg/mL 5–8 min [39]”
Tai, W., He, L., Zhang, X., Pu, J., Voronin, D., Jiang, S., Zhou, Y., & Du, L. (2020) · Cellular & Molecular Immunology · doi:10.1038/s41423-020-0400-4 · Cited by 1,654 · cited 1×
“fabricated a graphene-based FET biosensor for instant detection of SARS-CoV-2 spike S1 protein using monoclonal antibody immobilized, which had a LOD of 1 fg/mL [37].”
Middle East respiratory syndrome
Zumla, A., Hui, D. S., & Perlman, S. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60454-8 · Cited by 1,263
Molecular Architecture of the SARS-CoV-2 Virus
Yao, H., Song, Y., Chen, Y., Wu, N., Xu, J., Sun, C., Zhang, J., Weng, T., Zhang, Z., Wu, Z., et al. (2020) · Cell · doi:10.1016/j.cell.2020.09.018 · Cited by 1,060
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902 · cited 1×
“Electrochemical biosensors are advantageous for sensing biomolecules because of their ability to detect biomarkers with accuracy, specificity and high sensitivity [20].”
Transmission of SARS-CoV-2: A Review of Viral, Host, and Environmental Factors
Meyerowitz, E. A., Richterman, A., Gandhi, R. T., & Sax, P. E. (2021) · Annals of Internal Medicine · doi:10.7326/m20-5008 · Cited by 747
SARS — beginning to understand a new virus
Stadler, K., Masignani, V., Eickmann, M., Becker, S., Abrignani, S., Klenk, H.-D., & Rappuoli, R. (2003) · Nature Reviews Microbiology · doi:10.1038/nrmicro775 · Cited by 557 · cited 1×
“The three virus outbreaks were SARS-CoV in 2003 [3], MERS-CoV in 2012 [4], and the new SARS-CoV-2 in December 2019 [5].”
Middle East Respiratory Syndrome
Arabi, Y. M., Balkhy, H. H., Hayden, F. G., Bouchama, A., Luke, T., Baillie, J. K., Al-Omari, A., Hajeer, A. H., Senga, M., Denison, M. R., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmsr1408795 · Cited by 518
The genetic sequence, origin, and diagnosis of SARS-CoV-2
Wang, H., Li, X., Li, T., Zhang, S., Wang, L., Wu, X., & Liu, J. (2020) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-020-03899-4 · Cited by 491
Identifying the Mechanism of Biosensing with Carbon Nanotube Transistors
Heller, I., Janssens, A. M., Männik, J., Minot, E. D., Lemay, S. G., & Dekker, C. (2008) · Nano Letters · doi:10.1021/nl072996i · Cited by 490 · cited 1×
“The mechanism of source-drain current (IDS) decrease in carbon nanotube transistors may arise from the electrostatic gating effect and the Schottky barrier effect [36].”
Middle East respiratory syndrome
Memish, Z. A., Perlman, S., Van Kerkhove, M. D., & Zumla, A. (2020) · The Lancet · doi:10.1016/s0140-6736(19)33221-0 · Cited by 479 · cited 1×
“The three virus outbreaks were SARS-CoV in 2003 [3], MERS-CoV in 2012 [4], and the new SARS-CoV-2 in December 2019 [5].”
Virus-Receptor Interactions of Glycosylated SARS-CoV-2 Spike and Human ACE2 Receptor
Zhao, P., Praissman, J. L., Grant, O. C., Cai, Y., Xiao, T., Rosenbalm, K. E., Aoki, K., Kellman, B. P., Bridger, R., Barouch, D. H., et al. (2020) · Cell Host & Microbe · doi:10.1016/j.chom.2020.08.004 · Cited by 439
Carbon nanotube transistors for biosensing applications
Gruner, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3400-4 · Cited by 408 · cited 1×
“In each of these steps, the mobility of the CNT-FET device generally decreases by a small amount, as there are additional sources of dispersion of the charge carrier [33].”
Layqah, L. A., & Eissa, S. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3345-5 · Cited by 380 · cited 1×
“Previously electrochemical biosensors have been successfully used in medical diagnostics for the detection of viruses such as MERS-CoV [21], hepatitis C virus (HCV) [22], human influenza A virus H9N2 [23] and avian influenza virus (AIV) H5N1 [24].”
Immune-mediated approaches against COVID-19
Florindo, H. F., Kleiner, R., Vaskovich-Koubi, D., Acúrcio, R. C., Carreira, B., Yeini, E., Tiram, G., Liubomirski, Y., & Satchi-Fainaro, R. (2020) · Nature Nanotechnology · doi:10.1038/s41565-020-0732-3 · Cited by 338 · cited 1×
“SARS-CoV-2 inhaled through aerosol droplets binds to host cellular receptor ACE2 and targets activating proteases (for example, TMPRSS2, furin, and cathepsin L) for membrane fusion and reaches the host respiratory cells [15,16].”
Fathi-Hafshejani, P., Azam, N., Wang, L., Kuroda, M. A., Hamilton, M. C., Hasim, S., & Mahjouri-Samani, M. (2021) · ACS Nano · doi:10.1021/acsnano.1c01188 · Cited by 241
Rapid SARS-CoV-2 Spike Protein Detection by Carbon Nanotube-Based Near-Infrared Nanosensors
Pinals, R. L., Ledesma, F., Yang, D., Navarro, N., Jeong, S., Pak, J. E., Kuo, L., Chuang, Y.-C., Cheng, Y.-W., Sun, H.-Y., et al. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c00118 · Cited by 236
On the whereabouts of SARS-CoV-2 in the human body: A systematic review
Trypsteen, W., Van Cleemput, J., Snippenberg, W. V., Gerlo, S., & Vandekerckhove, L. (2020) · PLOS Pathogens · doi:10.1371/journal.ppat.1009037 · Cited by 199
Animal and translational models of SARS-CoV-2 infection and COVID-19
Johansen, M. D., Irving, A., Montagutelli, X., Tate, M. D., Rudloff, I., Nold, M. F., Hansbro, N. G., Kim, R. Y., Donovan, C., Liu, G., et al. (2020) · Mucosal Immunology · doi:10.1038/s41385-020-00340-z · Cited by 173 · cited 1×
“SARS-CoV-2 inhaled through aerosol droplets binds to host cellular receptor ACE2 and targets activating proteases (for example, TMPRSS2, furin, and cathepsin L) for membrane fusion and reaches the host respiratory cells [15,16].”
Kim, J. P., Lee, B. Y., Lee, J., Hong, S., & Sim, S. J. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.048 · Cited by 152 · cited 1×
“Based on the same modification and attachment chemistry, changes in IDS versus VGS induced by the functionalization process were consistent with previously reported findings [35].”
Anand, K. B., Karade, S. K., Sen, S., & Gupta, R. M. (2020) · Medical Journal Armed Forces India · doi:10.1016/j.mjafi.2020.04.008 · Cited by 151 · cited 1×
“Phylogenetic data analysis suggests that SARS-CoV-2 is further away from the SARS-CoV (79 %) and MERS-CoV (50 %) strains [6].”
Carbon nanotubes-based chemiresistive biosensors for detection of microorganisms
García‐Aljaro, C., Cella, L. N., Shirale, D. J., Park, M., Muñoz, F. J., Yates, M. V., & Mulchandani, A. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.077 · Cited by 150 · cited 1×
“7 immobilized antibodies on the biosensor [34].”
de Lima, L. F., Ferreira, A. L., Torres, M. D. T., de Araujo, W. R., & de la Fuente‐Núñez, C. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2106724118 · Cited by 134
Neutralizing antibodies targeting SARS-CoV-2 spike protein
Shi, X., Yu, L., Yan, L., Guang, Y., & Qiang, M. (2020) · Stem Cell Research · doi:10.1016/j.scr.2020.102125 · Cited by 123 · cited 1×
“S-protein is cleaved by host proteases into two subunits, S1 and S2; the S1 subunit functions in host cell recognition, cell invasion, and antibody neutralization [12].”
Sayhi, M., Ouerghi, O., Belgacem, K., Arbi, M., Büyüksünetçi, Y. T., Ghram, A., Anık, Ü., Österlund, L., Laouini, D., & Diouani, M. F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.018 · Cited by 99 · cited 1×
“Previously electrochemical biosensors have been successfully used in medical diagnostics for the detection of viruses such as MERS-CoV [21], hepatitis C virus (HCV) [22], human influenza A virus H9N2 [23] and avian influenza virus (AIV) H5N1 [24].”
Dastagir, T., Forzani, E., Zhang, R., Amlani, I., Nagahara, L. A., Tsui, R. K., & Tao, N. J. (2007) · The Analyst · doi:10.1039/b707025j · Cited by 76
Khosravi, F., Loeian, M. S., & Panchapakesan, B. (2017) · Biosensors · doi:10.3390/bios7020017 · Cited by 74
Protein Electrochemistry: Application in Medicine. A Review
Suprun, E. V., Shumyantseva, V. V., & Archakov, A. I. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.03.089 · Cited by 72 · cited 1×
“The sensitivity and time response of the biosensor varies with the number of immobilized detecting antibodies on the semiconducting CNT layer [38].”
Local-gated single-walled carbon nanotube field effect transistors assembled by AC dielectrophoresis
Stokes, P., & Khondaker, S. I. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/17/175202 · Cited by 57 · cited 1×
“No gate current leakage was observed, with almost zero IDS, suggesting a superior p-type transistor compared to previous reports [31].”
Spike Glycoprotein-Mediated Entry of SARS Coronaviruses
Wang, L., & Xiang, Y. (2020) · Viruses · doi:10.3390/v12111289 · Cited by 54
Sridharan, G. K., Vegunta, R., Vegunta, R., Mohan, B. P., & Rokkam, V. R. P. (2020) · International Journal of Preventive Medicine · doi:10.4103/ijpvm.ijpvm_255_20 · Cited by 46
Choi, H., Lee, J., Park, M., & Oh, J. (2017) · Journal of Food Quality · doi:10.1155/2017/5239487 · Cited by 40 · cited 1×
“The PBASE was immobilized on the surface of the carbon nanostructure by p-p non-covalent stacking between the six-membered ring of the CNT sidewall and the pyrene group of PBASE [26–28], while the succinimidyl ester group of the PBASE facing upward on the surface of CNT can react with an amine group of the target anti…”
Krebs, F., Scheller, C., Grove‐Heike, K., Pohl, L., & Wätzig, H. (2021) · Electrophoresis · doi:10.1002/elps.202100015 · Cited by 38 · cited 1×
“27) [40], and the SARS-CoV-2 S antigen is negatively charged (pI = 6.”
A carbon nanotube immunosensor for Salmonella
Lerner, M. B., Goldsmith, B. R., McMillon, R., Dailey, J., Pillai, S., Singh, S. R., & Johnson, A. T. C. (2011) · AIP Advances · doi:10.1063/1.3658573 · Cited by 33 · cited 1×
“Antibody immobilization leads to a 10– 50 % decrease in ON-state current because of enhanced electron dispersion from crowded and more complex chemical environments along the CNT-FET source-drain channel area [32].”
Khosravi, F., Trainor, P. J., Rai, S. N., Kloecker, G. H., Wickstrom, E., & Panchapakesan, B. (2016) · Nanotechnology · doi:10.1088/0957-4484/27/13/13lt02 · Cited by 19
Electrical detection of specific versus non-specific binding events in breast cancer cells
King, B. C., Clark, M., Burkhead, T. A., Sethu, P., Rai, S. N., Kloecker, G. H., & Panchapakesan, B. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.929875 · Cited by 6
Cited by
Carbon nanotubes in biomedical applications: current status, promises, and challenges
Murjani, B. O., Kadu, P. S., Bansod, M., Vaidya, S. S., & Yadav, M. D. (2022) · Carbon Letters · doi:10.1007/s42823-022-00364-4 · Cited by 264
Meskher, H., Ragdi, T., Thakur, A. K., Ha, S., Khelfaoui, I., Sathyamurthy, R., Sharshir, S. W., Pandey, A. K., Saidur, R., Singh, P., et al. (2024) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2023.2171277 · Cited by 225
“Contrary to other sensors, the use of a high-purity SWCNT-based semiconductor FET adorned with specialized binding chemistry to detect SARS-CoV-2 antigens in pharyngeal clinical samples exhibited excellent findings (Figure 7) [160].”
Das, A., Rewari, S., Kanaujia, B. K., Deswal, S. S., & Gupta, R. S. (2023) · Physica Scripta · doi:10.1088/1402-4896/acde16 · Cited by 49
Metadata
- Authors
- Zamzami, M. A., Rabbani, G., Ahmad, A., Basalah, A. A., Al-Sabban, W. H., Nate Ahn, S., & Choudhry, H.
- Venue
- Bioelectrochemistry
- Publisher
- Elsevier BV
- Published
- 2022-02
- Volume
- 143
- Pages
- 107982
- ISSN
- 1567-5394 (ISSN-L)
- OpenAlex
- W3207207292
- Cited by
- 211
- References
- 44
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.