Protein interactions with subcutaneously implanted biosensors
Abstract
Biofouling of in vivo glucose sensors has been indicated as the primary reason for sensitivity losses observed during the first 24 h after implant [Wisniewski N, Moussy F, Reichert WM. Characterization of implantable biosensor membrane biofouling. Fresen J Anal Chem 2000; 366(6-7): 611-621]. Identification of the biomolecules that contribute to these sensitivity perturbations is the primary objective of the research presented. Active needle-type glucose sensors were implanted in Sprague-Dawley rats for 24h, and then a proteomics approach was used to identify the substances absorbed to the sensors. MALDI-TOF mass spectrometry was the primary tool utilized to identify the biomolecules in sensor leachate samples and species absorbed directly on sensor membranes excised from explanted in vivo sensors. Not surprisingly serum albumin was identified as the primary biomolecule present, however, predominantly as endogenous fragments of the protein. In addition, several other biomolecule fragments, mainly less than 15 kD, were identified. Based on these findings, it is concluded that fragments of larger biomolecules infiltrate the sensor membranes causing diminished glucose diffusivity, thus decreasing in vivo sensitivity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A layer of inflammatory tissue forms around each CSII cannula that contains plasma proteins, platelets, red blood cells, white blood cells, and cellular debris.”
From Detailed Analysis of Insulin Absorption Variability and the Tissue Response to Continuous Subcutaneous Insulin Infusion Catheter Implantation in Swine (2017) · cites this paper as [15]
In the citing paper
“the majority of the biofouling proteins on the sensor membrane were fragments <15 kDa.102–103”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [102]
Citations
Cites
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M. S., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,996
ExPASy: the proteomics server for in-depth protein knowledge and analysis
Gasteiger, E. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg563 · Cited by 5,602
Rosenfeld, J., Capdevielle, J., Guillemot, J. C., & Ferrara, P. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90061-b · Cited by 1,239
Surveying for Surfaces that Resist the Adsorption of Proteins
Chapman, R., Ostuni, E., Takayama, S., Holmlin, R. E., Yan, L., & Whitesides, G. M. (2000) · Journal of the American Chemical Society · doi:10.1021/ja000774f · Cited by 600
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Self-citationIdentification of rapid changes at plasma–solid interfaces
Vroman, L., & Adams, A. L. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030106 · Cited by 422
Polyurethanes in Biomedical Applications
Lamba, N. M. K., Woodhouse, K. A., & Cooper, S. L. (2017) · Routledge eBooks · doi:10.1201/9780203742785-9 · Cited by 413
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186
Self-citationHallab, N. J., Bundy, K. J., O’Connor, K. C., Clark, R., & Moses, R. L. (1995) · PubMed · Cited by 144
Moatti-Sirat, D., Capron, F., Poitout, V., Reach, G., Bindra, D. S., Zhang, Y., Wilson, G. S., & Th�venot, D. R. (1992) · Diabetologia · doi:10.1007/bf00400921 · Cited by 123
Self-citationPerformance of subcutaneously implanted glucose sensors for continuous monitoring
Gerritsen, M. (1999) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(99)00006-6 · Cited by 122
Scopes, R. K., & Smith, J. A. (2006) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb1000s76 · Cited by 121
Thomé-Duret, V., Reach, G., Gangnerau, M. N., Lemonnier, F., Jc, K., Zhang, Y., Hu, Y., & Wilson, G. S. (1996) · Analytical Chemistry · doi:10.1021/ac960069i · Cited by 118
Self-citationJulliard, J. H., Shibasaki, T., LING, N. C., & Guillemin, R. (1980) · Science · doi:10.1126/science.6244620 · Cited by 116
Proteomic identification of age-dependent protein nitration in rat skeletal muscle
Kański, J., Alterman, M. A., & Schöneich, C. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(03)00500-8 · Cited by 108
Self-citationKoenig, A. L., Gambillara, V., & Grainger, D. W. (2002) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10316 · Cited by 106
Opioid peptides derived from hemoglobin: Hemorphins
Zhao, Q., Garreau-Balandier, I., Sannier, F., & Piot, J. (1997) · Biopolymers · doi:10.1002/(sici)1097-0282(1997)43:2 · Cited by 104
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89
Kerner, W., Kiwit, M., Linke, B., Keck, F. S., Zier, H., & Pfeiffer, E. F. (1993) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(93)80032-k · Cited by 75
Characterization of plasma proteins adsorbed onto biomaterials by MALDI-TOFMS
Oleschuk, R. D., McComb, M. E., Chow, A., Ens, W., Standing, K. G., Perreault, H., Marois, Y., & King, M. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00054-5 · Cited by 73
The Proteome Revisited Theory and Practice of all Relevant Electrophoretic Steps
(2001) · Journal of chromatography library · doi:10.1016/s0301-4770(01)x8031-7 · Cited by 68
Wildgruber, R., Reil, G., Drews, O., Parlar, H., & Görg, A. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200206)2:6 · Cited by 63
Self-citationGrainger, D. W., Pavon‐Djavid, G., Migonney, V., & Josefowicz, M. (2003) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856203322381456 · Cited by 53
A novel system of peptidergic regulation
Karelin, A. A., Blishchenko, E. Y., & Ivanov, V. T. (1998) · FEBS Letters · doi:10.1016/s0014-5793(98)00486-4 · Cited by 50
Glucose sensor with improved haemocompatibilty
Yang, Y. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00082-8 · Cited by 49
Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue.
Thomé-Duret, V., Gangnerau, M.-N., Zhang, Y., Wilson, G. S., & Reach, G. (1996) · PubMed · Cited by 42
Self-citationZav'yalov, V. P., Zaitseva, O., Navolotskaya, E. V., Abramov, V. M., Volodina, E. Y., & Mitin, Y. V. (1996) · Immunology Letters · doi:10.1016/0165-2478(95)02476-x · Cited by 30
Stimulated rat mast cells generate histamine-releasing peptide from albumin
Cochrane, D. E., Carraway, R. E., Feldberg, R. S., Boucher, W. S., & Gelfand, J. M. (1993) · Peptides · doi:10.1016/0196-9781(93)90018-c · Cited by 27
Novel Hyaluronic Acid Coating for Potential Use in Glucose Sensor Design
Praveen, S., Hanumantha, R., Belovich, J., & Davis, B. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503765691893 · Cited by 26
Ultrafiltration of human serum to determine the size of species that poison voltammetric electrodes
Elbicki, J. M., & Weber, S. G. (1989) · Biosensors · doi:10.1016/0265-928x(89)80039-2 · Cited by 24
Morphology and growth of murine cell lines on model biomaterials.
Godek, M. L., Duchsherer, N. L., McElwee, Q., & Grainger, D. W. (2004) · PubMed · Cited by 24
Ständker, L., Sillard, R., Bensch, K. W., Ruf, A., Raida, M., Schulz‐Knappe, P., Schepky, A. G., Patscheke, H., & Forssmann, W. (1995) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1995.2548 · Cited by 20
Cell responses to biomaterials II: Endothelial cell adhesion and growth on perfluorosulfonic acid
McAuslan, B. R., Johnson, G. M., Hannan, G. N., Norris, W. D., & Exner, T. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820221102 · Cited by 17
Ishihara, K., Nakabayashi, N., Nishida, K., Sakakida, M., & Shichiri, M. (1994) · ACS symposium series · doi:10.1021/bk-1994-0556.ch016 · Cited by 13
Jenney (2000) · doi:10.1002/(sici)1097-4636(20000605)50:3
Shen, M., & Horbett, T. A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011205)57:3
Research works printed but not linked: 3
- Dudley, 1993, Coatings for the prevention of fouling of microfiltration membranes, Chem Eng Res Des, 71, 327
- Ishihara, 1997, Prevention of protein adsorption by the phospholipid polymers, Polym Mater Sci Eng, 77, 574
- Zhang, 1993, Application of biosensors to in-vivo measurements, Proc. Electrochem. Soc., 93–97, 781
Cited by
Sorted by citations
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 383
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 302
Combinatorial Polyacrylamide Hydrogels for Preventing Biofouling on Implantable Biosensors
Chan, D. C., Chien, J., Axpe, E., Blankemeier, L., Baker, S. W., Swaminathan, S., Piunova, V. A., Zubarev, D. Y., Maikawa, C. L., Grosskopf, A. K., et al. (2022) · Advanced Materials · doi:10.1002/adma.202109764 · Cited by 222
Metadata
- Authors
- Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S.
- Affiliations
- University of Kansas (US)
- Corresponding author
- Wilson, George S.
- ORCID
- Alterman, Michail A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-04
- Volume
- 27
- Issue
- 12
- Pages
- 2587-2598
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2026455723
- Cited by
- 117
- References
- 40
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 5 · 2018: 7 · 2017: 9 · 2016: 9 · 2015: 9 · 2014: 7 · 2013: 7 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk055297-03)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK55297)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- subcutaneous glucose sensor, implantable biosensors, biofouling, protein adsorption, serum albumin, sensor membranes, proteomics, MALDI-TOF mass spectrometry
- MeSH terms
- Adsorption, Animals, Biocompatible Materials, Glucose, Male, Monitoring, Physiologic, Proteins, Biosensing Techniques, Rats, Sprague-Dawley, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Prostheses and Implants, Proteomics, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review