Protein interactions with subcutaneously implanted biosensors
Abstract
Biofouling of in vivo glucose sensors has been indicated as the primary reason for sensitivity losses observed during the first 24 h after implant [Wisniewski N, Moussy F, Reichert WM. Characterization of implantable biosensor membrane biofouling. Fresen J Anal Chem 2000; 366(6-7): 611-621]. Identification of the biomolecules that contribute to these sensitivity perturbations is the primary objective of the research presented. Active needle-type glucose sensors were implanted in Sprague-Dawley rats for 24h, and then a proteomics approach was used to identify the substances absorbed to the sensors. MALDI-TOF mass spectrometry was the primary tool utilized to identify the biomolecules in sensor leachate samples and species absorbed directly on sensor membranes excised from explanted in vivo sensors. Not surprisingly serum albumin was identified as the primary biomolecule present, however, predominantly as endogenous fragments of the protein. In addition, several other biomolecule fragments, mainly less than 15 kD, were identified. Based on these findings, it is concluded that fragments of larger biomolecules infiltrate the sensor membranes causing diminished glucose diffusivity, thus decreasing in vivo sensitivity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A layer of inflammatory tissue forms around each CSII cannula that contains plasma proteins, platelets, red blood cells, white blood cells, and cellular debris.”
From Detailed Analysis of Insulin Absorption Variability and the Tissue Response to Continuous Subcutaneous Insulin Infusion Catheter Implantation in Swine (2017) · cites this paper as [15]
In the citing paper
“the majority of the biofouling proteins on the sensor membrane were fragments <15 kDa.102–103”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [102]
Citations
Cites
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M. S., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,996
ExPASy: the proteomics server for in-depth protein knowledge and analysis
Gasteiger, E. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg563 · Cited by 5,602
Rosenfeld, J., Capdevielle, J., Guillemot, J. C., & Ferrara, P. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90061-b · Cited by 1,239
Surveying for Surfaces that Resist the Adsorption of Proteins
Chapman, R., Ostuni, E., Takayama, S., Holmlin, R. E., Yan, L., & Whitesides, G. M. (2000) · Journal of the American Chemical Society · doi:10.1021/ja000774f · Cited by 600
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Self-citationIdentification of rapid changes at plasma–solid interfaces
Vroman, L., & Adams, A. L. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030106 · Cited by 422
Polyurethanes in Biomedical Applications
Lamba, N. M. K., Woodhouse, K. A., & Cooper, S. L. (2017) · Routledge eBooks · doi:10.1201/9780203742785-9 · Cited by 413
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351
Research works printed but not linked: 3
- Dudley, 1993, Coatings for the prevention of fouling of microfiltration membranes, Chem Eng Res Des, 71, 327
- Ishihara, 1997, Prevention of protein adsorption by the phospholipid polymers, Polym Mater Sci Eng, 77, 574
- Zhang, 1993, Application of biosensors to in-vivo measurements, Proc. Electrochem. Soc., 93–97, 781
Cited by
Sorted by citations
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 383
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 302
Combinatorial Polyacrylamide Hydrogels for Preventing Biofouling on Implantable Biosensors
Chan, D. C., Chien, J., Axpe, E., Blankemeier, L., Baker, S. W., Swaminathan, S., Piunova, V. A., Zubarev, D. Y., Maikawa, C. L., Grosskopf, A. K., et al. (2022) · Advanced Materials · doi:10.1002/adma.202109764 · Cited by 222
Zhuo, Y., Yuan, P.-X., Yuan, R., Chai, Y.-Q., & Hong, C.-L. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.002 · Cited by 216
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Self-citationProtein Resistant Polymeric Biomaterials
Ngo, B. K. D., & Grunlan, M. A. (2017) · ACS Macro Letters · doi:10.1021/acsmacrolett.7b00448 · Cited by 169
A Microfabricated PDMS Microbial Fuel Cell
Siu, C.-P.-B., & Chiao, M. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2006816 · Cited by 136
Structural Determinants for Protein adsorption/non-adsorption to Silica Surface
Mathé, C., Devineau, S., Aude, J.-C., Lagniel, G., Chédin, S., Legros, V., Mathon, M., Renault, J., Pin, S., Boulard, Y., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081346 · Cited by 142
Foreign Body Reaction to Subcutaneous Implants
Kastellorizios, M., Tipnis, N. P., & Burgess, D. J. (2015) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-18603-0_6 · Cited by 118
Microfabricated, amperometric, enzyme-based biosensors for in vivo applications
Weltin, A., Kieninger, J., & Urban, G. A. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9420-4 · Cited by 109
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99
Continuous Glucose Monitoring: 40 Years, What We′ve Learned and What’s Next
Gifford, R. (2013) · ChemPhysChem · doi:10.1002/cphc.201300172 · Cited by 98
Self-citationElshaarani, T., Yu, H., Wang, L., Zain‐ul‐Abdin, Z., Ullah, R. S., Haroon, M., Khan, R. U., Fahad, S., Khan, A., Nazir, A., et al. (2018) · Journal of Materials Chemistry B · doi:10.1039/c7tb03332j · Cited by 96
Hu, Y., Liang, B., Lü, F., Ma, G., Yang, G. Y., Zhu, Q. Y., Chen, S., & Ye, X. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b03016 · Cited by 95
Lin, G., Chang, S., Hao, H., Tathireddy, P., Orthner, M. P., Magda, J. J., & Solzbacher, F. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.07.054 · Cited by 91
Gui, A. L., Luais, E., Peterson, J. R., & Gooding, J. J. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am400519m · Cited by 91
In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility
Soto, R. J., Hall, J. R., Brown, M. D., Taylor, J. B., & Schoenfisch, M. H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04251 · Cited by 87
Borgmann, S., Schulte, A., Neugebauer, S., & Schuhmann, W. W. (2011) · Advances in electrochemical science and engineering · doi:10.1002/9783527644117.ch1 · Cited by 93
A review on B-type natriuretic peptide monitoring: assays and biosensors
Maalouf, R., & Bailey, S. R. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9544-9 · Cited by 82
Tiny Medicine: Nanomaterial-Based Biosensors
Yun, Y., Eteshola, E., Bhattacharya, A., Dong, Z., Shim, J. S., Conforti, L., Kim, D., Schulz, M. J., Ahn, C. H., & Watts, N. B. (2009) · Sensors · doi:10.3390/s91109275 · Cited by 86
Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings
Shen, J., & Burgess, D. J. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.10.020 · Cited by 79
Hatakeyama, E. S., Ju, H., Gabriel, C. J., Lohr, J. L., Bara, J. E., Noble, R. D., Freeman, B. D., & Gin, D. L. (2009) · Journal of Membrane Science · doi:10.1016/j.memsci.2008.12.049 · Cited by 76
Kondepati, V. R., & Heise, H. M. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1229-8 · Cited by 75
Meyers, S. R., Khoo, X., Huang, X. H., Walsh, E. B., Grinstaff, M. W., & Kenan, D. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.042 · Cited by 68
Implantable application of polymer‐based biosensors
Mei, X., Ye, D., Zhang, F., & Di, C. (2021) · Journal of Polymer Science · doi:10.1002/pol.20210543 · Cited by 64
Nanomaterials for Biosensors and Implantable Biodevices
Luz, R. A. S., Iost, R. M., & Crespilho, F. N. (2012) · Springer eBooks · doi:10.1007/978-3-642-29250-7_2 · Cited by 65
Metabolic Biofouling of Glucose Sensors in Vivo : Role of Tissue Microhemorrhages
Klueh, U., Liu, Z., Feldman, B., Henning, T. P., Cho, B., Ouyang, T., & Kreutzer, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500313 · Cited by 63
López-Méndez, T. B., Santos‐Vizcaíno, E., Pedraz, J. L., Orive, G., & Hernández, R. M. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.06.006 · Cited by 61
Justin, G. A., Finley, S. H., Rahman, A. R. A., & Guiseppi‐Elie, A. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9214-3 · Cited by 60
Justin, G. A., & Guiseppi‐Elie, A. (2009) · Biomacromolecules · doi:10.1021/bm900486d · Cited by 58
Wahono, N., Qin, S., Oomen, P. E., Cremers, T. I. F. H., de Vries, M. G., & Westerink, B. H. C. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.01.019 · Cited by 52
Ammam, M., & Fransaer, J. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.11.001 · Cited by 48
Integrated zwitterionic conjugated poly(carboxybetaine thiophene) as a new biomaterial platform
Cao, B., Tang, Q., Li, L., Lee, C.-J., Wang, H., Zhang, Y., Castaneda, H., & Cheng, G. (2014) · Chemical Science · doi:10.1039/c4sc02200a · Cited by 48
A tris(2,2′-bipyridyl)cobalt(III)-bovine serum albumin composite membrane for biosensors
Zhuo, Y., Yuan, R., Chai, Y., Sun, A., Zhang, Y. Q., & Yang, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.012 · Cited by 46
Hossain, M. F., & Park, J. Y. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173553 · Cited by 44
In Vivo Analytical Performance of Nitric Oxide-Releasing Glucose Biosensors
Soto, R. J., Privett, B. J., & Schoenfisch, M. H. (2014) · Analytical Chemistry · doi:10.1021/ac5017425 · Cited by 42
A Review of Safety and Hazards Associated With the Artificial Pancreas
Ramkissoon, C. M., Aufderheide, B., Bequette, B. W., & Vehı́, J. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2749038 · Cited by 41
Application of responsive polymers in implantable medical devices and biosensors
Li, J., Stachowski, M., & Zhang, Z. (2015) · Elsevier eBooks · doi:10.1016/b978-0-85709-713-2.00011-0 · Cited by 41
Ammam, M., & Easton, E. B. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.04.016 · Cited by 41
Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200611 · Cited by 41
Hauzenberger, J. R., Hipszer, B. R., Loeum, C., McCue, P. A., DeStefano, M., Torjman, M. C., Kaner, M. T., Dinesen, A. R., Chervoneva, I., Pieber, T. R., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0175 · Cited by 39
Electrochemical methods for neural interface electrodes
Weltin, A., & Kieninger, J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac28d5 · Cited by 39
A miniaturized transcutaneous system for continuous glucose monitoring
Croce, R. A., Vaddiraju, S., Kondo, J., Wang, Y., Zuo, L., Zhu, K., ISLAM, S. K., Burgess, D. J., Papadimitrakopoulos, F., & Jain, F. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9708-x · Cited by 38
Surface characterization techniques for polyurethane biomaterials
Zhang, H. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100614-6.00002-0 · Cited by 41
Wilson, G. S., & Ammam, M. (2007) · FEBS Journal · doi:10.1111/j.1742-4658.2007.06077.x · Cited by 35
Self-citationInfluence of diabetes on the foreign body response to nitric oxide-releasing implants
Soto, R. J., Merricks, E. P., Bellinger, D. A., Nichols, T. C., & Schoenfisch, M. H. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.044 · Cited by 35
Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats
Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.016 · Cited by 33
A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve
Yi, Y., Zaher, A., Yassine, O., Kosel, J., & Foulds, I. G. (2015) · Biomicrofluidics · doi:10.1063/1.4927436 · Cited by 33
Microelectrode Biosensors for in vivo Analysis of Brain Interstitial Fluid
Chatard, C., Meiller, A., & Marinesco, S. (2018) · Electroanalysis · doi:10.1002/elan.201700836 · Cited by 34
Mixing in colliding, ultrasonically levitated drops.
Chainani, E., Choi, W., Ngo, K. T., & Scheeline, A. (2014) · Analytical Chemistry · doi:10.1021/ac403968d · Cited by 33
A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring
Chu, M. K., Kudo, H., Shirai, T., Miyajima, K., Saito, H., Morimoto, N., Yano, K., Iwasaki, Y., Akiyoshi, K., & Mitsubayashi, K. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9300-1 · Cited by 31
Surface modifications of silicon nitride for cellular biosensor applications
Gustavsson, J. S., Altankov, G., Errachid, A., Samitier, J., Planell, J. A., & Engel, E. (2008) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-008-3384-7 · Cited by 30
Proteins at Interfaces III: Introductory Overview
Norde, W., Horbett, T. A., & Brash, J. L. (2012) · ACS symposium series · doi:10.1021/bk-2012-1120.ch001 · Cited by 30
The development of a novel urea sensor using polypyrrole
Hamilton, A., & Breslin, C. B. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.08.052 · Cited by 29
The Impact of Implantable Sensors in Biomedical Technology on the Future of Healthcare Systems
Darwish, A., Sayed, G. I., & Hassanien, A. E. (2019) · doi:10.1002/9781119439004.ch3 · Cited by 29
Secretory and continuous expression of Aspergillus niger glucose oxidase gene in Pichia pastoris
Yamaguchi, M., Tahara, Y., Nakano, A., & Taniyama, T. (2007) · Protein Expression and Purification · doi:10.1016/j.pep.2007.05.006 · Cited by 29
Comparison of the Effects of Biofouling on Voltammetric and Potentiometric Measurements
Kuhlmann, J., Dzugan, L. C., & Heineman, W. R. (2012) · Electroanalysis · doi:10.1002/elan.201200194 · Cited by 27
Hasanzadeh, M., Shadjou, N., & de la Guárdia, M. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.02.011 · Cited by 27
Ortiz, R., Olsen, S. M., & Thormann, E. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b00030 · Cited by 27
Increased In Vivo Glucose Recovery via Nitric Oxide Release
Nichols, S. P., Le, N. N., Klitzman, B., & Schoenfisch, M. H. (2011) · Analytical Chemistry · doi:10.1021/ac103070t · Cited by 26
Local release of masitinib alters in vivo implantable continuous glucose sensor performance
Avula, M., Jones, D., Rao, A. N., McClain, D. A., McGill, L. D., Grainger, D. W., & Solzbacher, F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.059 · Cited by 26
Low-Fouling Characteristics of Ultrathin Zwitterionic Cysteine SAMs
Lin, P., Chuang, T., Chen, P., Lin, C., & Gu, F. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b01525 · Cited by 28
Ammam, M., & Fransaer, J. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.11.015 · Cited by 25
Mugweru, A. M., Clark, B. L., & Pishko, M. V. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100308 · Cited by 25
Tujunen, N., Kaivosoja, E., Protopopova, V. S., Valle‐Delgado, J. J., Österberg, M., Koskinen, J., & Laurila, T. T. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.05.060 · Cited by 25
Hossain, M. F., & Park, J. Y. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0951507jes · Cited by 21
Adsorbed Proteins on Biomaterials
Horbett, T. A. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00036-x · Cited by 19
Stach, M., Kroneková, Z., Kasák, P., Kollár, J., Pentrak, M. P., Mičušík, M., Chorvat, D., Jr., Nunney, T. S., & Lacı́k, I. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.07.102 · Cited by 18
Ahmad, L., Salmon, L., & Korri‐Youssoufi, H. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126933 · Cited by 17
Dexamethasone Release from Uniform Sized Nanoengineered Alginate Microspheres
Jayant, R. D., & Srivastava, R. (2007) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2007.039 · Cited by 17
Sharifi, A., Varsavsky, A., Ulloa, J., Horsburgh, J. C., McAuley, S. A., Krishnamurthy, B., Jenkins, A. J., Colman, P. G., Ward, G. M., MacIsaac, R. J., et al. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815612096 · Cited by 16
Goel, A., Tathireddy, H., Wang, S., Vu, H. H., Puy, C., Hinds, M. T., Zonies, D. H., McCarty, O. J. T., & Shatzel, J. J. (2023) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0043-57011 · Cited by 16
Klueh, U., Liu, Z., Ouyang, T., Cho, B., Feldman, B., Henning, T. P., & Kreutzer, D. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100607 · Cited by 14
Introduction to the Glucose Sensing Problem
Wilson, G. S., & Zhang, Y. (2009) · doi:10.1002/9780470567319.ch1 · Cited by 13
Self-citationMolinnus, D., Janus, K. A., Fang, A. C., Drinic, A., Achtsnicht, S., Köpf, M., Keusgen, M., & Schöning, M. J. (2022) · physica status solidi (a) · doi:10.1002/pssa.202200100 · Cited by 12
Finnerty, N. J., & Bolger, F. B. (2017) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2017.09.010 · Cited by 12
Adsorbed Proteins on Biomaterials
Horbett, T. A., & Latour, R. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00042-8 · Cited by 12
Dexamethasone-Enhanced Microdialysis and Penetration Injury
Jaquins‐Gerstl, A., & Michael, A. C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602266 · Cited by 11
Lubricin as a tool for controlling adhesion in vivo and ex vivo
Manasa, C. S., Silva, S. M., Desroches, P. E., Dennaoui, J., Russo, M. J., Han, M., Quigley, A. F., Greene, G. W., Kapsa, R. M. I., & Moulton, S. E. (2021) · Biointerphases · doi:10.1116/6.0000779 · Cited by 11
Crosstalk the Microdialysis in Scientific Research: from Principle to its Applications
Lee, M. K. K. (2013) · Pharmaceutica Analytica Acta · doi:10.4172/2153-2435.1000276 · Cited by 10
Long–term Drifts in Sensitivity Caused by Biofouling of an Amperometric Oxygen Sensor
Patrick, M., Grillot, J. M., Derden, Z. M., & Paul, D. W. (2016) · Electroanalysis · doi:10.1002/elan.201600653 · Cited by 10
Smart hydrogel based microsensing platform for continuous glucose monitoring
Tathireddy, P., Avula, M., Lin, G., Cho, S. H., Guenther, M., Schulz, V., Gerlach, G., Magda, J. J., & Solzbacher, F. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626231 · Cited by 10
Janus, K. A., Achtsnicht, S., Tempel, L., Drinic, A., Kopp, A., Keusgen, M., & Schöning, M. J. (2023) · physica status solidi (a) · doi:10.1002/pssa.202300081 · Cited by 7
Enrico, P., & Diana, M. (2017) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2017.00097 · Cited by 8
Mou, X., & Stenken, J. A. (2006) · Analytical Chemistry · doi:10.1021/ac061124i · Cited by 7
3.34 Biomaterials Challenges in Continuous Glucose Monitors In Vivo
Rao, A. N., Avula, M., & Grainger, D. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09314-0 · Cited by 7
The macrophage–biomaterial interface: a proteomic analysis of the conditioned medium environment
Dinnes, D. L. M., Marçal, H., Raftery, M. J., Labow, R. S., & Mahler, S. M. (2008) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1854 · Cited by 6
Xu, H., Wallace, R., & Hepel, M. (2015) · Chemical Papers · doi:10.1515/chempap-2015-0015 · Cited by 4
Blending polymer outer membrane for continuous glucose monitoring with an extended lifetime
Zuo, Y., Lei, L., Huang, K., Zhang, T., Hao, Q., Zhao, C., & Liu, H. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136142 · Cited by 3
Aravamudhan, S. (2012) · Elsevier eBooks · doi:10.1533/9780857096272.2.79 · Cited by 3
A low power miniaturized CMOS-based continuous glucose monitoring system
Croce, R. A., Vaddiraju, S., Legassey, A., Wang, Y., Burgess, D. J., Papadimitrakopoulos, F., & Jain, F. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575469 · Cited by 3
Saux, G. L., Plawinski, L., Nlate, S., Ripoche, J., Buffeteau, T., & Durrieu, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150706 · Cited by 3
Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial
Tauschmann, M., Allen, J. M., Wilinska, M. E., Ruan, Y., Thabit, H., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816678631 · Cited by 3
Lafleur, L. K., & Yager, P. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00085-1 · Cited by 3
Advanced sensors for implantable devices
Çalışır, M., Özgür, E., & Deni̇zli̇, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00024-7 · Cited by 2
Carbon Nanotube Wire for Use in Precision Medical Devices
Yin, Z., Dong, Z., Cahay, M. M., Pixley, S. K., Haworth, K. J., Rahimi, M., Goh, S. K., Starnes, S. L., Patwardhan, M., Chaudhary, S., et al. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-812667-7.00031-8 · Cited by 2
Victor, S. P., Sharma, C. P., & Sreenivasan, K. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.09.119 · Cited by 2
Baican, M. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813932-5.00004-2 · Cited by 2
Metadata
- Authors
- Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S.
- Affiliations
- University of Kansas (US)
- Corresponding author
- Wilson, George S.
- ORCID
- Alterman, Michail A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-04
- Volume
- 27
- Issue
- 12
- Pages
- 2587-2598
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2026455723
- Cited by
- 117
- References
- 40
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 5 · 2018: 7 · 2017: 9 · 2016: 9 · 2015: 9 · 2014: 7 · 2013: 7 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk055297-03)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK55297)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- subcutaneous glucose sensor, implantable biosensors, biofouling, protein adsorption, serum albumin, sensor membranes, proteomics, MALDI-TOF mass spectrometry
- MeSH terms
- Adsorption, Animals, Biocompatible Materials, Glucose, Male, Monitoring, Physiologic, Proteins, Biosensing Techniques, Rats, Sprague-Dawley, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Prostheses and Implants, Proteomics, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review