The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
In vitro corrosion and biocompatibility of binary magnesium alloys
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How useful is SBF in predicting in vivo bone bioactivity?
Kokubo, T., & Takadama, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.017 · Cited by 9,576
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Corrosion Mechanisms of Magnesium Alloys
Song, G. L., & Atrens, A. (1999) · Advanced Engineering Materials · doi:10.1002/(sici)1527-2648(199909)1:1<11::aid-adem11>3.0.co;2-n · Cited by 2,365
Understanding Magnesium Corrosion—A Framework for Improved Alloy Performance
Song, G., & Atrens, A. (2003) · Advanced Engineering Materials · doi:10.1002/adem.200310405 · Cited by 2,056
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Self-citationControl of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Reffitt, D. M., Ogston, N., Jugdaohsingh, R., Cheung, H. F. J., Evans, B. A. J., Thompson, R. P. H., Powell, J. J., & Hampson, G. N. (2003) · Bone · doi:10.1016/s8756-3282(02)00950-x · Cited by 876
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Biodegradable magnesium–hydroxyapatite metal matrix composites
Witte, F., Feyerabend, F., Maier, P., Fischer, J., Störmer, M., Blawert, C., Dietzel, W., & Hort, N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.027 · Cited by 642
Handbook on toxicity of inorganic compounds
Seiler, H. G., Sigel, H., Sigel, A., & Townshend, A. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83960-4 · Cited by 595
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells
Yamamoto, A., Honma, R., & Sumita, M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199802)39:2<331::aid-jbm22>3.0.co;2-e · Cited by 569
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Kannan, M. B., & Raman, R. K. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.02.003 · Cited by 545
Exposure, metabolism, and toxicity of rare earths and related compounds.
Hirano, S., & Suzuki, K. T. (1996) · Environmental Health Perspectives · doi:10.1289/ehp.96104s185 · Cited by 540
Metal ion release from metal implants
Hanawa, T. (2004) · Materials Science and Engineering: C · doi:10.1016/j.msec.2004.08.018 · Cited by 528
In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application
Xu, L., Yu, G., Zhang, E., Pan, F., & Yang, K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31273 · Cited by 520
Nutrition in Bone Health Revisited: A Story Beyond Calcium
Ilich, J. Z., & Kerstetter, J. E. (2000) · Journal of the American College of Nutrition · doi:10.1080/07315724.2000.10718070 · Cited by 509
A Possible Biodegradable Magnesium Implant Material
Song, G., & Song, S. (2007) · Advanced Engineering Materials · doi:10.1002/adem.200600252 · Cited by 487
Review of studies on corrosion of magnesium alloys
ZENG, R.-C., ZHANG, J., HUANG, W.-J., DIETZEL, W., KAINER, K. U., BLAWERT, C., & KE, W. (2006) · Transactions of Nonferrous Metals Society of China · doi:10.1016/s1003-6326(06)60297-5 · Cited by 449
Li, L., Gao, J., & Wang, Y. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.01.004 · Cited by 441
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Zartner, P., Cesnjevar, R., Singer, H., & Weyand, M. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20520 · Cited by 347
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Neuropathology of aluminum toxicity in rats (glutamate and GABA impairment)
El-Rahman, S. (2003) · Pharmacological Research · doi:10.1016/s1043-6618(02)00336-5 · Cited by 321
Handbook on toxicity of inorganic compounds.
Scozzafava, A. (1989) · Inorganica Chimica Acta · doi:10.1016/s0020-1693(00)83413-1 · Cited by 316
Platelet interactions with titanium: modulation of platelet activity by surface topography
Park, J. Y., Gemmell, C. H., & Davies, J. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00009-6 · Cited by 297
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10106 · Cited by 280
Keeting, P. E., Oursler, M. J., Wiegand, K. E., Bonde, S. K., Spelsberg, T. C., & Riggs, B. L. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650071107 · Cited by 249
Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries
WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O. (2008) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2007.00319.x · Cited by 244
Nakamura, Y. (1997) · Fundamental and Applied Toxicology · doi:10.1006/faat.1997.2322 · Cited by 234
B iocompatibility of D ental C asting A lloys
Geurtsen, W. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300108 · Cited by 221
Schedle, A., Samorapoompichit, P., Rausch-Fan, X. H., Franz, A., Füreder, W., Sperr, W. R., Sperr, W., Ellinger, A., Slavicek, R., Boltz-Nitulescu, G., et al. (1995) · Journal of Dental Research · doi:10.1177/00220345950740081301 · Cited by 210
Liu, C., Xin, Y., Tang, G., & Chu, P. K. (2007) · Materials Science and Engineering: A · doi:10.1016/j.msea.2006.12.020 · Cited by 176
Relationship between the hemolytic action of heavy metals and lipid peroxidation
Ribarov, S. R., & Benov, L. C. (1981) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(81)90102-4 · Cited by 160
Control of smooth muscle cell proliferation by ferrous iron
Mueller, P. P., May, T., Perz, A., Häuser, H., & Peuster, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.042 · Cited by 148
Rettig, R., & Virtanen, S. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31550 · Cited by 148
Bone-like matrix formation on magnesium and magnesium alloys
Pietak, A. M., Mahoney, P., Dias, G. J., & Staiger, M. P. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3172-9 · Cited by 137
Müller, W. D., Nascimento, M. L., Zeddies, M., Córsico, M., Gassa, L. M., & de Mele, M. F. L. (2007) · Materials Research · doi:10.1590/s1516-14392007000100003 · Cited by 137
Nielsen, F. H. (2000) · The Journal of Trace Elements in Experimental Medicine · Cited by 90
Cytotoxicity of Dental Alloy Extracts and Corresponding Metal Salt Solutions
Schmalz, G., Langer, H., & Schweikl, H. (1998) · Journal of Dental Research · doi:10.1177/00220345980770100401 · Cited by 81
Wataha, J. C., Hanks, C. T., & Craig, R. G. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261004 · Cited by 66
Intravesical chemotherapy: Studies on the relationship between ph and cytotoxicity
Groos, E., Walker, L., & Masters, J. R. (1986) · Cancer · doi:10.1002/1097-0142(19860915)58:6<1199::aid-cncr2820580604>3.0.co;2-z · Cited by 55
Jha, A. M., & Singh, A. C. (1995) · Mutation Research/Genetic Toxicology · doi:10.1016/0165-1218(95)90009-8 · Cited by 51
Concepts on metal ion toxicity
Sigel, H. (1986) · Metal ions in biological systems · Cited by 35
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Self-citationChen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Kirkland, N. T., Birbilis, N., & Staiger, M. P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.014 · Cited by 856
Metadata
- Authors
- Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 30
- Issue
- 4
- Pages
- 484-498
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2080109744
- Cited by
- 1,343
- References
- 46
- FWCI
- 18.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.