Engineered skeletal muscle tissue networks with controllable architecture
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The engineering of functional skeletal muscle tissue substitutes holds promise for the treatment of various muscular diseases and injuries. However, no tissue fabrication technology currently exists for the generation of a relatively large and thick bioartificial muscle made of densely packed, uniformly aligned, and differentiated myofibers. In this study, we describe a versatile cell/hydrogel micromolding approach where polydimethylsiloxane (PDMS) molds containing an array of elongated posts were used to fabricate relatively large neonatal rat skeletal muscle tissue networks with reproducible and controllable architecture. By combining cell-mediated fibrin gel compaction and precise microfabrication of mold dimensions including the length and height of the PDMS posts, we were able to simultaneously support high cell viability, guide cell alignment along the microfabricated tissue pores, and reproducibly control the overall tissue porosity, size, and thickness. The interconnected muscle bundles within the porous tissue networks were composed of densely packed, aligned, and highly differentiated myofibers. The formed myofibers expressed myogenin, developed abundant cross-striations, and generated spontaneous tissue contractions at the macroscopic spatial scale. The proliferation of non-muscle cells was significantly reduced compared to monolayer cultures. The more complex muscle tissue architectures were fabricated by controlling the spatial distribution and direction of the PDMS posts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Directed assembly of cell-laden microgels for fabrication of 3D tissue constructs
Du, Y., Lo, E., Ali, S., & Khademhosseini, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801866105 · Cited by 591
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Mechanical stimulation improves tissue-engineered human skeletal muscle
Powell, C. A., Smiley, B. L., Mills, J., & Vandenburgh, H. H. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00595.2001 · Cited by 498
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467 · cited 1×
“These rapid prototyping techniques enable reproducible design of scaffold geometry [17], systematic control of porosity and pore interconnectivity [18], precise positioning of one or more cell types in the desired 3D configuration [15], and layered assembly of 3D objects [14], all of which may facilitate the reproduci…”
Fabrication of 3D hepatic tissues by additive photopatterning of cellular hydrogels
Tsang, V. L., Chen, A. A., Cho, L. M., Jadin, K. D., Sah, R. L., DeLong, S., West, J. L., & Bhatia, S. N. (2007) · The FASEB Journal · doi:10.1096/fj.06-7117com · Cited by 462
Rapid formation of functional muscle in vitro using fibrin gels
Huang, Y.-C., Dennis, R. G., Larkin, L., & Baar, K. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00273.2004 · Cited by 316
Cummings, C. L., Gawlitta, D., Nerem, R. M., & Stegemann, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.073 · Cited by 311
Skeletal muscle tissue engineering
Bach, A. D., Beier, J. P., Stern‐Staeter, J., & Horch, R. E. (2004) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2004.tb00466.x · Cited by 303
Optimizing Engineered Heart Tissue for Therapeutic Applications as Surrogate Heart Muscle
Naito, H., Melnychenko, I., Didié, M., Schneiderbanger, K., Schubert, P., Rosenkranz, S., Eschenhagen, T., & Zimmermann, W.-H. (2006) · Circulation · doi:10.1161/circulationaha.105.001560 · Cited by 301
The elasticity of an individual fibrin fiber in a clot
Collet, J., Shuman, H., Ledger, R. E., Lee, S., & Weisel, J. W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504120102 · Cited by 294
Elastic fiber production in cardiovascular tissue-equivalents
Long, J. L., & Tranquillo, R. T. (2003) · Matrix Biology · doi:10.1016/s0945-053x(03)00052-0 · Cited by 283
Photo-patterning of porous hydrogels for tissue engineering
Bryant, S. J., Cuy, J. L., Hauch, K. D., & Ratner, B. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.033 · Cited by 263
Cell Mechanics Studied by a Reconstituted Model Tissue
Wakatsuki, T., Kolodney, M. S., Zahalak, G. I., & Elson, E. L. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76481-2 · Cited by 236
Long-Term Cyclic Distention Enhances the Mechanical Properties of Collagen-Based Media-Equivalents
Isenberg, B. C., & Tranquillo, R. T. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1590662 · Cited by 204
Collagen matrices attenuate the collagen-synthetic response of cultured fibroblasts to TGF-β
Clark, R. A. F., Nielsen, L. D., Welch, M. P., & McPherson, J. M. (1995) · Journal of Cell Science · doi:10.1242/jcs.108.3.1251 · Cited by 204
Laser‐layered microfabrication of spatially patterned functionalized tissue‐engineering scaffolds
Mapili, G., Lu, Y., Chen, S., & Roy, K. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30325 · Cited by 202
EASTWOOD, M., MCGROUTHER, D., & BROWN, R. (1994) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(94)90040-x · Cited by 197
Yelbuz, T. M., Choma, M. A., Thrane, L., Kirby, M. L., & Izatt, J. A. (2002) · Circulation · doi:10.1161/01.cir.0000042672.51054.7b · Cited by 173
Kroehne, V., Heschel, I., Schügner, F., Lasrich, D., Bartsch, J. W., & Jockusch, H. (2008) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2008.00238.x · Cited by 171
KONDOH, H., SAWA, Y., MIYAGAWA, S., SAKAKIDAKITAGAWA, S., MEMON, I., KAWAGUCHI, N., MATSUURA, N., SHIMIZU, T., OKANO, T., & MATSUDA, H. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.005 · Cited by 169
Micromechanical bending of single collagen fibrils using atomic force microscopy
Yang, L., van der Werf, K. O., Koopman, H. F. J. M., Subramaniam, V., Bennink, M. L., Dijkstra, P. J., & Feijén, J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31127 · Cited by 161
Costa, K. D., Lee, E. J., & Holmes, J. W. (2003) · Tissue Engineering · doi:10.1089/107632703768247278 · Cited by 158
Automated measurement of myofiber disarray in transgenic mice with ventricular expression ofras
Karlon, W. J., Covell, J. W., McCulloch, A. D., Hunter, J. J., & Omens, J. H. (1998) · The Anatomical Record · Cited by 153
Novel anisotropic engineered cardiac tissues: Studies of electrical propagation
Bursac, N., Loo, Y., Leong, K. W., & Tung, L. (2007) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2007.07.138 · Cited by 144
Self-citationStructure and Functional Evaluation of Tendon–Skeletal Muscle Constructs Engineered in Vitro
Larkin, L. M., Calve, S., Kostrominova, T. Y., & Arruda, E. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3149 · Cited by 137
Robinson, P. S., Johnson, S. L., Evans, M. C., Barocas, V. H., & Tranquillo, R. T. (2008) · Tissue Engineering Part A · doi:10.1089/ten.a.2007.0148 · Cited by 125
Deyne, P. G. D. (2000) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2000.279.6.c1801 · Cited by 118
A rapid prototyping technique for the fabrication of solvent-resistant structures
Harrison, C. K., Cabral, J. T., Stafford, C. M., Karim, A., & Amis, E. J. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/021 · Cited by 115
Bursac, N., Papadaki, M., White, J. A., Eisenberg, S. R., Vunjak‐Novakovic, G., & Freed, L. E. (2003) · Tissue Engineering · doi:10.1089/10763270360728152 · Cited by 109
Self-citationTissue Engineering of Skeletal Muscle
Yan, W., George, S., Fotadar, U., Tyhovych, N., Kamer, A. R., Yost, M. J., Price, R. L., Haggart, C. R., Holmes, J. W., & Terracio, L. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0408 · Cited by 80
Rhim, C., Lowell, D. A., Reedy, M. C., Slentz, D. H., Zhang, S. J., Kraus, W. E., & Truskey, G. A. (2007) · Muscle & Nerve · doi:10.1002/mus.20788 · Cited by 75
Fabrication of Mitral Valve Chordae by Directed Collagen Gel Shrinkage
Shi, Y., & Veselý, I. (2003) · Tissue Engineering · doi:10.1089/10763270360728143 · Cited by 69
Norman, J. J., & Desai, T. A. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.378 · Cited by 59
Three-dimensional simulation of anisotropic cell-driven collagen gel compaction
Ohsumi, T. K., Flaherty, J. E., Evans, M. C., & Barocas, V. H. (2007) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-007-0075-0 · Cited by 36
Siegal, G. P., Wang, M., Rinehart, C. A., Kennedy, J. W., Goodly, L. J., Miller, Y., Kaufman, D. G., & Singh, R. K. (1993) · Cancer Letters · doi:10.1016/0304-3835(93)90164-5 · Cited by 36
Novel Geometries for Tissue-Engineered Tendonous Collagen Constructs
Shi, Y., Rittman, L., & Veselý, I. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2601 · Cited by 35
An In Vitro System to Evaluate the Effects of Ischemia on Survival of Cells Used for Cell Therapy
Davis, B. H., Schroeder, T., Yarmolenko, P., Guilak, F., Dewhirst, M. W., & Taylor, D. A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9301-2 · Cited by 31
Three-dimensional engineered heart tissue from neonatal rat cardiac myocytes
Zimmermann, W. H., Fink, C., Kralisch, D., Remmers, U., Weil, J., & Eschenhagen, T. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000405)68:1<106::aid-bit13>3.0.co;2-3
Cited by
A review of trends and limitations in hydrogel-rapid prototyping for tissue engineering
Billiet, T., Vandenhaute, M., Schelfhout, J., Van Vlierberghe, S., & Dubruel, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.050 · Cited by 1,284
Stephens, N., Di Silvio, L., Dunsford, I., Ellis, M., Glencross, A., & Sexton, A. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2018.04.010 · Cited by 768
Zhang, B., Montgomery, M., Chamberlain, M. D., Ogawa, S., Korolj, A., Pahnke, A., Wells, L. A., Massé, S., Kim, J., Reis, L., et al. (2016) · Nature Materials · doi:10.1038/nmat4570 · Cited by 593
Biopolymer-based microgels/nanogels for drug delivery applications
Oh, J. K., Lee, D. I., & Park, J. M. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.08.001 · Cited by 542
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Metadata
- Authors
- Bian, W., & Bursac, N.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 30
- Issue
- 7
- Pages
- 1401-1412
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2096415654
- Cited by
- 287
- References
- 40
- FWCI
- 13.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.