Engineered skeletal muscle tissue networks with controllable architecture
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The engineering of functional skeletal muscle tissue substitutes holds promise for the treatment of various muscular diseases and injuries. However, no tissue fabrication technology currently exists for the generation of a relatively large and thick bioartificial muscle made of densely packed, uniformly aligned, and differentiated myofibers. In this study, we describe a versatile cell/hydrogel micromolding approach where polydimethylsiloxane (PDMS) molds containing an array of elongated posts were used to fabricate relatively large neonatal rat skeletal muscle tissue networks with reproducible and controllable architecture. By combining cell-mediated fibrin gel compaction and precise microfabrication of mold dimensions including the length and height of the PDMS posts, we were able to simultaneously support high cell viability, guide cell alignment along the microfabricated tissue pores, and reproducibly control the overall tissue porosity, size, and thickness. The interconnected muscle bundles within the porous tissue networks were composed of densely packed, aligned, and highly differentiated myofibers. The formed myofibers expressed myogenin, developed abundant cross-striations, and generated spontaneous tissue contractions at the macroscopic spatial scale. The proliferation of non-muscle cells was significantly reduced compared to monolayer cultures. The more complex muscle tissue architectures were fabricated by controlling the spatial distribution and direction of the PDMS posts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Directed assembly of cell-laden microgels for fabrication of 3D tissue constructs
Du, Y., Lo, E., Ali, S., & Khademhosseini, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801866105 · Cited by 591
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Mechanical stimulation improves tissue-engineered human skeletal muscle
Powell, C. A., Smiley, B. L., Mills, J., & Vandenburgh, H. H. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00595.2001 · Cited by 498
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467 · cited 1×
“These rapid prototyping techniques enable reproducible design of scaffold geometry [17], systematic control of porosity and pore interconnectivity [18], precise positioning of one or more cell types in the desired 3D configuration [15], and layered assembly of 3D objects [14], all of which may facilitate the reproduci…”
Fabrication of 3D hepatic tissues by additive photopatterning of cellular hydrogels
Tsang, V. L., Chen, A. A., Cho, L. M., Jadin, K. D., Sah, R. L., DeLong, S., West, J. L., & Bhatia, S. N. (2007) · The FASEB Journal · doi:10.1096/fj.06-7117com · Cited by 462
Rapid formation of functional muscle in vitro using fibrin gels
Huang, Y.-C., Dennis, R. G., Larkin, L., & Baar, K. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00273.2004 · Cited by 316
Cummings, C. L., Gawlitta, D., Nerem, R. M., & Stegemann, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.073 · Cited by 311
Skeletal muscle tissue engineering
Bach, A. D., Beier, J. P., Stern‐Staeter, J., & Horch, R. E. (2004) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2004.tb00466.x · Cited by 303
Cited by
A review of trends and limitations in hydrogel-rapid prototyping for tissue engineering
Billiet, T., Vandenhaute, M., Schelfhout, J., Van Vlierberghe, S., & Dubruel, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.050 · Cited by 1,284
Stephens, N., Di Silvio, L., Dunsford, I., Ellis, M., Glencross, A., & Sexton, A. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2018.04.010 · Cited by 768
Zhang, B., Montgomery, M., Chamberlain, M. D., Ogawa, S., Korolj, A., Pahnke, A., Wells, L. A., Massé, S., Kim, J., Reis, L., et al. (2016) · Nature Materials · doi:10.1038/nmat4570 · Cited by 593
Biopolymer-based microgels/nanogels for drug delivery applications
Oh, J. K., Lee, D. I., & Park, J. M. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.08.001 · Cited by 542
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Qazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
Microfabricated Biomaterials for Engineering 3D Tissues
Zorlutuna, P., Annabi, N., Camci‐Unal, G., Nikkhah, M., Cha, J. M., Nichol, J. W., Manbachi, A., Bae, H., Chen, S., & Khademhosseini, A. (2012) · Advanced Materials · doi:10.1002/adma.201104631 · Cited by 394
Yeong, W. Y., Sudarmadji, N., Yu, H. Y., Chua, C. K., Leong, K. F., Venkatraman, S. S., Boey, Y. C. F., & Tan, L. P. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.033 · Cited by 355
Mehrali, M., Thakur, A., Pennisi, C. P., Talebian, S., Arpanaei, A., Nikkhah, M., & Dolatshahi‐Pirouz, A. (2017) · Advanced Materials · doi:10.1002/adma.201603612 · Cited by 345
Biohybrid robot powered by an antagonistic pair of skeletal muscle tissues
Morimoto, Y., Onoe, H., & Takeuchi, S. (2018) · Science Robotics · doi:10.1126/scirobotics.aat4440 · Cited by 302
Tailoring Gelation Mechanisms for Advanced Hydrogel Applications
Nele, V., Wojciechowski, J. P., Armstrong, J. P. K., & Stevens, M. M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202002759 · Cited by 300
Chal, J., Al Tanoury, Z., Hestin, M., Gobert, B., Aivio, S., Hick, A., Cherrier, T., Nesmith, A. P., Parker, K. K., & Pourquié, O. (2016) · Nature Protocols · doi:10.1038/nprot.2016.110 · Cited by 299
Formation and optogenetic control of engineered 3D skeletal muscle bioactuators
Sakar, M. S., Neal, D., Boudou, T., Borochin, M. A., Li, Y., Weiss, R., Kamm, R. D., Chen, C. S., & Asada, H. H. (2012) · Lab on a Chip · doi:10.1039/c2lc40338b · Cited by 288
Hinds, S., Bian, W., Dennis, R. G., & Bursac, N. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.062 · Cited by 287
Self-citationBio‐Origami Hydrogel Scaffolds Composed of Photocrosslinked PEG Bilayers
Jamal, M., Kadam, S. S., Xiao, R., Jivan, F., Onn, T., Fernandes, R., Nguyen, T. D., & Gracias, D. H. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201200458 · Cited by 270
Constructions and Properties of Physically Cross-Linked Hydrogels Based on Natural Polymers
Yang, J., Chen, Y., Zhao, L., Zhang, J., & Luo, H. (2023) · Polymer Reviews · doi:10.1080/15583724.2022.2137525 · Cited by 261
Nanocomposite hydrogels for tissue engineering applications
Zhao, H., Liu, M., Zhang, Y., Yin, J., & Pei, R. (2020) · Nanoscale · doi:10.1039/d0nr03785k · Cited by 258
Aligned electrospun polymer fibres for skeletal muscle regeneration
School of Materials, B. G., Aviss, K., Gough, J., & Downes, S. (2010) · European Cells and Materials · doi:10.22203/ecm.v019a19 · Cited by 253
Juhas, M., Engelmayr, G. C., Fontanella, A. N., Palmer, G. M., & Bursac, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402723111 · Cited by 246
Self-citationBiomimetic scaffolds for regeneration of volumetric muscle loss in skeletal muscle injuries
Grasman, J. M., Zayas, M. J., Page, R. L., & Pins, G. D. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.038 · Cited by 244
Naturally derived and synthetic scaffolds for skeletal muscle reconstruction
Wolf, M. T., Dearth, C. L., Sonnenberg, S. B., Loboa, E. G., & Badylak, S. F. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.08.011 · Cited by 230
“More complex patterns can be introduced in hydrogels to create myotube networks in vitro that yield improved viability and differentiation [42].”
BackgroundMesoscopic hydrogel molding to control the 3D geometry of bioartificial muscle tissues
Bian, W., Liau, B., Badie, N., & Bursac, N. (2009) · Nature Protocols · doi:10.1038/nprot.2009.155 · Cited by 225
“Mesoscopic hydrogel molding for engineering of bioartificial muscle Here we present details of a hydrogel molding method developed in our laborator”
MethodSelf-citationScaffolds for the manufacture of cultured meat
Seah, J. S. H., Singh, S., Tan, L. P., & Choudhury, D. (2022) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2021.1931803 · Cited by 209
Heher, P., Maleiner, B., Prüller, J., Teuschl, A. H., Kollmitzer, J., Monforte, X., Wolbank, S., Redl, H., Rünzler, D., & Fuchs, C. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.06.033 · Cited by 195
“extensively used as scaffold materials for skeletal muscle engineering due to their biocompatibility and – degradability [8-14].”
BackgroundThree-dimensional neuron–muscle constructs with neuromuscular junctions
Morimoto, Y., Kato-Negishi, M., Onoe, H., & Takeuchi, S. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.062 · Cited by 195
Rapid Prototyping for Biomedical Engineering: Current Capabilities and Challenges
Lantada, A. D., & Morgado, P. L. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150112 · Cited by 171
Technological, Regulatory, and Ethical Aspects of In Vitro Meat: A Future Slaughter‐Free Harvest
Bhat, Z. F., Morton, J. D., Mason, S. L., Bekhit, A. E. A., & Bhat, H. F. (2019) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12473 · Cited by 161
Das, S., Kim, S.-W., Choi, Y.-J., Lee, S., Lee, S.-H., Kong, J.-S., Park, H.-J., Cho, D.-W., & Jang, J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.026 · Cited by 150
Metadata
- Authors
- Bian, W., & Bursac, N.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 30
- Issue
- 7
- Pages
- 1401-1412
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2096415654
- Cited by
- 287
- References
- 40
- FWCI
- 13.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.