The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Implantable arterial grafts from human fibroblasts and fibrin using a multi-graft pulsed flow-stretch bioreactor with noninvasive strength monitoring
Open accessAbstract
Tissue-engineered arteries based on entrapment of human dermal fibroblasts in fibrin gel yield completely biological vascular grafts that possess circumferential alignment characteristic of native arteries and essential to their mechanical properties. A bioreactor was developed to condition six grafts in the same culture medium while being subjected to similar cyclic distension and transmural flow resulting from pulsed flow distributed among the graft lumens via a manifold. The lumenal pressure and circumferential stretch were noninvasively monitored and used to calculate stiffness in the range of 80-120 mmHg and then to successfully predict graft burst strength. The length of the graft was incrementally shortened during bioreactor culture to maintain circumferential alignment and achieve mechanical anisotropy comparable to native arteries. After 7-9 weeks of bioreactor culture, the fibrin-based grafts were extensively remodeled by the fibroblasts into circumferentially-aligned tubes of collagen and other extracellular matrix with burst pressures in the range of 1400-1600 mmHg and compliance comparable to native arteries. The tissue suture retention force was also suitable for implantation in the rat model and, with poly(lactic acid) sewing rings entrapped at both ends of the graft, also in the ovine model. The strength achieved with a biological scaffold in such a short duration is unprecedented for an engineered artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191259 · Cited by 3,908
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191261 · Cited by 3,140
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Determination of hydroxyproline
Stegemann, H., & Stalder, K. (1967) · Clinica Chimica Acta · doi:10.1016/0009-8981(67)90167-2 · Cited by 1,570
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Fluorometric assay of DNA in cartilage explants using Hoechst 33258
Kim, Y.-J., Sah, R. L. Y., Doong, J.-Y. H., & Grodzinsky, A. J. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90532-5 · Cited by 1,357
Human tissue-engineered blood vessels for adult arterial revascularization
L'Heureux, N., Dusserre, N., Konig, G., Victor, B., Keire, P., Wight, T. N., Chronos, N. A. F., Kyles, A. E., Gregory, C. R., Hoyt, G., et al. (2006) · Nature Medicine · doi:10.1038/nm1364 · Cited by 1,083
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804 · cited 1×
“Arterial grafts developed from synthetic polymers have been shown to achieve sufficient strength [7], but acidification resulting from the polymer hydrolysis and the resulting host responses are potential limitations [8].”
BackgroundKonig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.011 · Cited by 582
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Current status of prosthetic bypass grafts: A review
Kannan, R. Y., Salacinski, H. J., Butler, P. E., Hamilton, G., & Seifalian, A. M. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30247 · Cited by 527
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Self-citationFibrin gel as a three dimensional matrix in cardiovascular tissue engineering
Ye, Q., Zünd, G., Benedikt, P., Jockenhoevel, S., Hoerstrup, S. P., Sakyama, S., Hubbell, J. A., & Turina, M. (2000) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(00)00373-0 · Cited by 419
Barocas, V. H., & Tranquillo, R. T. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2796072 · Cited by 355
Self-citationTissue engineering of small caliber vascular grafts
Hoerstrup, S. (2001) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(01)00706-0 · Cited by 281
Engineering of fibrin-based functional and implantable small-diameter blood vessels
Swartz, D. D., Russell, J. A., & Andreadis, S. T. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00479.2004 · Cited by 277
The ideal small arterial substitute: a search for the Holy Grail?
Conte, M. S. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.43 · Cited by 245
Long-Term Cyclic Distention Enhances the Mechanical Properties of Collagen-Based Media-Equivalents
Isenberg, B. C., & Tranquillo, R. T. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1590662 · Cited by 204
Self-citationA fibrin‐based arterial media equivalent
Grassl, E. D., Oegema, T. R., & Tranquillo, R. T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10589 · Cited by 196
Self-citationPurification and comparison of elastins from different animal species
Starcher, B. C., & Galione, M. J. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90224-4 · Cited by 187
Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs
Seliktar, D., Nerem, R. M., & Galis, Z. S. (2003) · Tissue Engineering · doi:10.1089/107632703768247359 · Cited by 179
Syedain, Z. H., Weinberg, J. S., & Tranquillo, R. T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711217105 · Cited by 179
Self-citationEngineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction
Barocas, V. H., Girton, T. S., & Tranquillo, R. T. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834759 · Cited by 164
Self-citationMechanical Properties and Compositions of Tissue Engineered and Native Arteries
Dahl, S. L. M., Rhim, C., Song, Y. C., & Niklason, L. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9226-1 · Cited by 145
Tschoeke, B., Flanagan, T. C., Koch, S., Harwoko, M. S., Deichmann, T., Ellä, V., Sachweh, J. S., Kellomäki, M., Gries, T., Schmitz‐Rode, T., et al. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0499 · Cited by 113
Endothelialization and Flow Conditioning of Fibrin-Based Media-Equivalents
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9101-0 · Cited by 100
Self-citationEffect of Pulse Rate on Collagen Deposition in the Tissue-Engineered Blood Vessel
Solan, A. K., Mitchell, S., Moses, M. A., & Niklason, L. E. (2003) · Tissue Engineering · doi:10.1089/107632703768247287 · Cited by 80
Diffusion of Insulin-Like Growth Factor-I and Ribonuclease through Fibrin Gels
Nauman, J. V., Campbell, P. G., Lanni, F., & Anderson, J. L. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.102699 · Cited by 66
Transmural flow bioreactor for vascular tissue engineering
Bjork, J. W., & Tranquillo, R. T. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22475 · Cited by 32
Self-citation
Cited by
Extracellular matrix-based materials for regenerative medicine
Hussey, G. S., Dziki, J. L., & Badylak, S. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0023-x · Cited by 844
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Gao, G., Lee, J. H., Jang, J., Lee, D. H., Kong, J., Kim, B. S., Choi, Y., Jang, W. B., Hong, Y. J., Kwon, S., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700798 · Cited by 336
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Bioengineering human tissues and the future of vascular replacement
Naegeli, K. M., Kural, M. H., Li, Y., Wang, J., Hugentobler, E. A., & Niklason, L. E. (2022) · Circulation Research · doi:10.1161/circresaha.121.319984 · Cited by 112
Metadata
- Authors
- Syedain, Z. H., Meier, L. A., Bjork, J. W., Lee, A., & Tranquillo, R. T.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 32
- Issue
- 3
- Pages
- 714-722
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1996481646
- Cited by
- 254
- References
- 29
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.