Cited by 103Hydrogels: synthesis, properties, applicationsMolecular Sensors and Ion DetectionAnalytical Chemistry and Sensors

Towards the real-time monitoring of glucose in tear fluid: Holographic glucose sensors with reduced interference from lactate and pH

Yang, Xiaoping, Pan, Xiaohan, Blyth, Jeff, Lowe, Christopher R.·2008·Biosensors and Bioelectronics

Abstract

Glucose-selective holographic sensors were fabricated from unique tetrahedral 2-acrylamidophenylboronic acid (2-APB) incorporated with co-monomers poly(ethylene glycol) acrylate (PEG), (3-acrylamidopropyl)trimethylammonium chloride (ATMA) and [2-(acryloyloxy)ethyl]-trimethylammonium chloride (AETA) into thin hydrogel films which were transformed into volume holograms using a diffusion method coupled with holographic recording using a frequency-doubled Nd:YAG laser (532 nm). The results showed that the 2-APB-based holographic sensors contracted upon addition of glucose due to the formation of a 2:1 complex between the tetrahedral 2-APB and glucose. More significantly, the 2-APB-based holographic sensors had greatly reduced lactate dependence and a hugely reduced pH effect over the physiological range of pH. These features are vital for development of contact lens-based glucose sensor, where the pH variability is greater (pH 5.8-7.8) and the lactate concentration is substantially higher than in blood. Furthermore, the 2-APB-based holographic sensors also displayed fast response to glucose. The successful union of holograms and the tetrahedral 2-APB receptor for glucose detection in artificial tear fluid is also demonstrated. This new type of holographic sensors responding to glucose with features of minor pH effect and negligible interference from lactate is applicable to the detection of glucose concentrations in tear fluid for the management of diabetes.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2007.09.016

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Continuous glucose monitoring systems use minimally invasive subcutaneous electrochemical sensors to measure glucose concentration in interstitial fluid.

    “Continuous glucose monitoring systems utilize minimally invasive subcutaneous sensors to measure glucose concentration in interstitial fluid via electrochemistry.83”

    From Wearables in Medicine (2018) · cites this paper as [83]

Cited by

Sorted by citations

Authors
Yang, X., Pan, X., Blyth, J., & Lowe, C. R.
Affiliations
University of Cambridge (GB)
Corresponding author
Lowe, Christopher R.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2008-01
Volume
23
Issue
6
Pages
899-905
ISSN
0956-5663 (ISSN-L)
OpenAlex
W1999061909
Cited by
103
References
0
Citations by year
2026: 2 · 2025: 5 · 2024: 5 · 2023: 2 · 2022: 4 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 3 · 2017: 8 · 2016: 7 · 2015: 6 · 2014: 13 · 2013: 15 · 2012: 5
FWCI
2.26
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
Gates Cambridge Trust
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pH effect, volume holograms, hydrogel films, diabetes management
MeSH terms
Quaternary Ammonium Compounds, Boron Compounds, Glucose, Holography, Hydrogen-Ion Concentration, Magnetic Resonance Spectroscopy, Ophthalmic Solutions, Biosensing Techniques, Lactic Acid, Hydrogels

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review