The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration
Open accessAbstract
Here we present two types of all-printable, highly stretchable, and inexpensive devices based on platinum (Pt)-decorated graphite for glucose determination in physiological fluids. Said devices are: a non-enzymatic sensor and an enzymatic biosensor, the latter showing promising results. Glucose has been quantified by measuring hydrogen peroxide (H 2 O 2) reduction by chronoamperometry at -0.35V (vs pseudo-Ag/AgCl) using glucose oxidase immobilized on Pt-decorated graphite. The sensor performs well for the quantification of glucose in phosphate buffer solution (0.25M PBS, pH 7.0), with a linear range between 0 mM and 0.9mM, high sensitivity and selectivity, and a low limit of detection (LOD). Thus, it provides an alternative non-invasive and on-body quantification of glucose levels in human perspiration. This biosensor has been successfully applied on real human perspiration samples and results also show a significant correlation between glucose concentration in perspiration and glucose concentration in blood measured by a commercial glucose meter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This device was applied on human perspiration samples and demonstrated a strong correlation between glucose concentration in perspiration and glucose concentration in blood, as measured via a commercial glucose meter.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [64]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics and Chemometrics for Analytical Chemistry
Ziegel, E. R. (2004) · Technometrics · doi:10.1198/tech.2004.s248 · Cited by 4,433
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,779
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,352
Bankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,304
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,164
Peng, Z., & Yang, H. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.010 · Cited by 1,085
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · cited 1×
“As a result, Wang and co-workers focused on the development of wearable electrochemical devices able to monitor several target analytes in physiological fluids, like saliva, tears or perspiration (Bandodkar et al., 2016, 2015; Jia et al., 2013; Kim et al., 2015).”
BackgroundSelf-citationTattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationWearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Self-citationCorrelation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Glucose: Detection and analysis
Galant, A., Kaufman, R. C., & Wilson, J. D. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.04.071 · Cited by 350
Recent developments in blood glucose sensors
Wang, H.-C., & Lee, A. (2015) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2014.12.001 · Cited by 320
Flexible glucose sensor using CVD-grown graphene-based field effect transistor
Kwak, Y. H., Choi, D. S., Kim, Y. N., Kim, H., Yoon, D. H., Ahn, S., Yang, J., Yang, W. S., & Seo, S. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.04.042 · Cited by 285
Formulation and stability of a novel artificial human sweat under conditions of storage and use
Harvey, C. J., LeBouf, R. F., & Stefaniak, A. B. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.06.016 · Cited by 275
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Highly Selective Membrane-Free, Mediator-Free Glucose Biosensor
Wang, J., Liu, J., Chen, L., & Lü, F. (1994) · Analytical Chemistry · doi:10.1021/ac00093a011 · Cited by 174
Self-citationAnalysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153
A glucose oxidase-coupled DNAzyme sensor for glucose detection in tears and saliva
Liu, C., Sheng, Y., Sun, Y., Feng, J., Wang, S., Zhang, J., Xu, J., & Jiang, D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.070 · Cited by 108
Flexible graphene bio-nanosensor for lactate
Labroo, P., & Cui, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.024 · Cited by 102
Electrochemical studies of hydrogen peroxide at a platinum disc electrode
Prabhu, V. G., Zarapkar, L. R., & Dhaneshwar, R. G. (1981) · Electrochimica Acta · doi:10.1016/0013-4686(81)90029-3 · Cited by 94
Zhu, J., Zhu, Z., Lai, Z., Wang, R., Guo, X., Wu, X., Zhang, G., Zhang, Z., Wang, Y., & Chen, Z. (2002) · Sensors · doi:10.3390/s20400127 · Cited by 88
Pu, Z., Wang, R., Wu, J., Yu, H., Xu, K., & Li, D. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.115 · Cited by 85
Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
Cui, G. (2001) · Talanta · doi:10.1016/s0039-9140(01)00377-0 · Cited by 60
Rabti, A., Argoubi, W., & Raouafi, N. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1753-3 · Cited by 52
Ladgotra, A. (2016) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2016/19135.7995 · Cited by 51
Sakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Hamaguchi, T., Matsuo, T., Miyagawa, J.-I., Namba, M., Sato, T., Okada, S., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700313 · Cited by 50
Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood
Harborn, U., Xie, B., VENKATESH, R., & Danielsson, B. R. G. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(97)00151-4 · Cited by 49
Zhang, H., Bo, X., & Guo, L. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.03.102 · Cited by 45
Vagin, M. Y., Jeerapan, I., Wannapob, R., Thavarungkul, P., Kanatharana, P., Anwar, N., McCormac∥, T., Eriksson, M., Turner, A. P. F., Jager, E. W. H., et al. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.12.183 · Cited by 21
Self-citationMicro/Nanostructured Films and Adhesives for Biomedical Applications
Lee, J. K., Kang, S. M., Yang, S. H., & Cho, W. K. (2015) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2015.2097 · Cited by 14
Flagged first, then by citations
Research works printed but not linked: 2
- Ancel Keys, 1934, J. Biol. Chem., 27, 839
- Lodgotra, 2016, J. Clin. Diagn. Res., 10, ZC56
Cited by
Sorted by citations
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationAdvanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,312
Maduraiveeran, G., Sasidharan, M., & Ganesan, V. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.12.031 · Cited by 919
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 796
Metadata
- Authors
- Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E.
- Affiliations
- University of Alicante (ES)
- University of California San Diego (US)
- Corresponding author
- Morallón, E.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 91
- Pages
- 885-891
- ISSN
- 0956-5663 (ISSN-L)
- PMC
- PMC5328638
- OpenAlex
- W2580319474
- Cited by
- 348
- References
- 32
- Citations by year
- 2026: 17 · 2025: 31 · 2024: 34 · 2023: 38 · 2022: 46 · 2021: 43 · 2020: 42 · 2019: 54 · 2018: 32 · 2017: 11
- FWCI
- 15.79
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion)
- Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante) (submittedVersion)
- Funders
- Universidad de Alicante
- University of San Diego
- National Institutes of Health (R21EB019698)
- Ministerio de Economía y Competitividad (MAT2016-76595-R)
- Generalitat Valenciana (Prometeo2013/038)
- National Institute of Biomedical Imaging and Bioengineering
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- glucose biosensor, sweating, stretchable sensors, screen-printed electrodes, glucose oxidase, non-enzymatic glucose sensing, hydrogen peroxide reduction, chronoamperometry, non-invasive glucose monitoring, on-body sensing
- MeSH terms
- Adult, Elasticity, Electrodes, Enzymes, Immobilized, Equipment Design, Female, Glucose, Glucose Oxidase, Graphite, Humans, Hydrogen Peroxide, Male, Platinum, Sweat, Biosensing Techniques, Electrochemical Techniques, Young Adult, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review