Cited by 348Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAdvanced biosensing and bioanalysis techniques

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration

Open access

Abstract

Here we present two types of all-printable, highly stretchable, and inexpensive devices based on platinum (Pt)-decorated graphite for glucose determination in physiological fluids. Said devices are: a non-enzymatic sensor and an enzymatic biosensor, the latter showing promising results. Glucose has been quantified by measuring hydrogen peroxide (H 2 O 2) reduction by chronoamperometry at -0.35V (vs pseudo-Ag/AgCl) using glucose oxidase immobilized on Pt-decorated graphite. The sensor performs well for the quantification of glucose in phosphate buffer solution (0.25M PBS, pH 7.0), with a linear range between 0 mM and 0.9mM, high sensitivity and selectivity, and a low limit of detection (LOD). Thus, it provides an alternative non-invasive and on-body quantification of glucose levels in human perspiration. This biosensor has been successfully applied on real human perspiration samples and results also show a significant correlation between glucose concentration in perspiration and glucose concentration in blood measured by a commercial glucose meter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2017.01.058

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. Ancel Keys, 1934, J. Biol. Chem., 27, 839
  2. Lodgotra, 2016, J. Clin. Diagn. Res., 10, ZC56

Cited by

Sorted by citations

See all 348

Metadata

Authors
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E.
Affiliations
  • University of Alicante (ES)
  • University of California San Diego (US)
Corresponding author
Morallón, E.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2017-05
Volume
91
Pages
885-891
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2580319474
Cited by
348
References
32
Citations by year
2026: 17 · 2025: 31 · 2024: 34 · 2023: 38 · 2022: 46 · 2021: 43 · 2020: 42 · 2019: 54 · 2018: 32 · 2017: 11
FWCI
15.79
Type
journal article
Language
en
Open access
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion)
  • Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante) (submittedVersion)
Funders
  • Universidad de Alicante
  • University of San Diego
  • National Institutes of Health (R21EB019698)
  • Ministerio de Economía y Competitividad (MAT2016-76595-R)
  • Generalitat Valenciana (Prometeo2013/038)
  • National Institute of Biomedical Imaging and Bioengineering
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
glucose biosensor, sweating, stretchable sensors, screen-printed electrodes, glucose oxidase, non-enzymatic glucose sensing, hydrogen peroxide reduction, chronoamperometry, non-invasive glucose monitoring, on-body sensing
MeSH terms
Adult, Elasticity, Electrodes, Enzymes, Immobilized, Equipment Design, Female, Glucose, Glucose Oxidase, Graphite, Humans, Hydrogen Peroxide, Male, Platinum, Sweat, Biosensing Techniques, Electrochemical Techniques, Young Adult, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review