The DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Detection principles of biological and chemical FET sensors
Open accessAbstract
The seminal importance of detecting ions and molecules for point-of-care tests has driven the search for more sensitive, specific, and robust sensors. Electronic detection holds promise for future miniaturized in-situ applications and can be integrated into existing electronic manufacturing processes and technology. The resulting small devices will be inherently well suited for multiplexed and parallel detection. In this review, different field-effect transistor (FET) structures and detection principles are discussed, including label-free and indirect detection mechanisms. The fundamental detection principle governing every potentiometric sensor is introduced, and different state-of-the-art FET sensor structures are reviewed. This is followed by an analysis of electrolyte interfaces and their influence on sensor operation. Finally, the fundamentals of different detection mechanisms are reviewed and some detection schemes are discussed. In the conclusion, current commercial efforts are briefly considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Intermolecular and Surface Forces
(2011) · Elsevier eBooks · doi:10.1016/c2011-0-05119-0 · Cited by 8,968
Functional Nanoscale Electronic Devices Assembled Using Silicon Nanowire Building Blocks
Cui, Y., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5505.851 · Cited by 3,258
An integrated semiconductor device enabling non-optical genome sequencing
Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M., et al. (2011) · Nature · doi:10.1038/nature10242 · Cited by 2,172
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Solid state electronic devices
Streetman, B. G. (1972) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,475
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
The use of electrochemical impedance spectroscopy for biosensing
Lisdat, F., & Schäfer, D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1970-7 · Cited by 858
Steric effects in the dynamics of electrolytes at large applied voltages. I. Double-layer charging
Kilic, M. S., Bazant, M. Z., & Ajdari, A. (2007) · Physical Review E · doi:10.1103/physreve.75.021502 · Cited by 815
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Recent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
A general model to describe the electrostatic potential at electrolyte oxide interfaces
van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1996) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(96)00307-7 · Cited by 402
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
The extended gate chemically sensitive field effect transistor as multi-species microprobe
van der spiegel, J., Lauks, I., Chan, P., & Babic, D. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85035-5 · Cited by 370
Simultaneous DNA amplification and detection using a pH-sensing semiconductor system
Toumazou, C., Shepherd, L. M., Reed, S. C., Chen, G. I., Patel, A., Garner, D. M., Wang, C.-J. A., Ou, C.-P., Amin-Desai, K., Athanasiou, P., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2520 · Cited by 356
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Privett, B. J., Shin, J. H., & Schoenfisch, M. H. (2010) · Analytical Chemistry · doi:10.1021/ac101075n · Cited by 334
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333
Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology
Bausells, J., Carrabina, J., Errachid, A., & Merlos, A. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00135-5 · Cited by 327
van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)85043-0 · Cited by 311
Accurate Simulations of Electric Double Layer Capacitance of Ultramicroelectrodes
Wang, H., & Pilon, L. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp204498e · Cited by 307
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
Specific detection of biomolecules in physiological solutions using graphene transistor biosensors
Gao, N., Gao, T., Yang, X., Dai, X., Zhou, W., Zhang, A., & Lieber, C. M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1625010114 · Cited by 274
Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
Pejcic, B., & De Marco, R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.04.025 · Cited by 270
Gao, N., Zhou, W., Jiang, X., Hong, G., Fu, T.-M., & Lieber, C. M. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00133 · Cited by 268
Poghossian, A., Cherstvy, A., Ingebrandt, S., Offenhäusser, A., & Schöning, M. J. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.03.083 · Cited by 261
Labelfree fully electronic nucleic acid detection system based on a field-effect transistor device
Uslu, F., Ingebrandt, S., Mayer, D., Böcker-Meffert, S., Odenthal, M., & Offenhäusser, A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.019 · Cited by 255
Recent advances in lab-on-a-chip for biosensing applications
Lafleur, J. P., Jönsson, A., Senkbeil, S., & Kutter, J. P. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.003 · Cited by 241
A physical model for drift in pH ISFETs
Jamasb, S., Collins, S., & Smith, R. L. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00040-9 · Cited by 239
Development of electrochemical immunosensors towards point of care diagnostics
Wan, Y., Su, Y., Zhu, X., Liu, G., & Fan, C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.045 · Cited by 232
A charge-modulated FET for detection of biomolecular processes: conception, modeling, and simulation
Barbaro, M., Bonfiglio, A., & Raffo, L. (2006) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2005.860659 · Cited by 196
Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: A review
Ahmad, F., & Hashsham, S. A. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.04.031 · Cited by 178
van der Schoot, B. H., & Bergveld, P. (1987) · Biosensors · doi:10.1016/0265-928x(87)80025-1 · Cited by 177
Dual‐Gate Thin‐Film Transistors, Integrated Circuits and Sensors
Spijkman, M., Myny, K., Smits, E. C. P., Heremans, P., Blom, P. W. M., & de Leeuw, D. M. (2011) · Advanced Materials · doi:10.1002/adma.201101493 · Cited by 176
A behavioral macromodel of the ISFET in SPICE
Martinoia, S., & Massobrio, G. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00377-9 · Cited by 173
Real-time imaging of microparticles and living cells with CMOS nanocapacitor arrays
Laborde, C., Pittino, F., Verhoeven, H. A., Lemay, S. G., Selmi, L., Jongsma, M. A., & Widdershoven, F. P. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.163 · Cited by 164
On the origin of enhanced sensitivity in nanoscale FET-based biosensors
Shoorideh, K., & Chui, C. O. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315485111 · Cited by 162
DNA Diagnostics: Nanotechnology-Enhanced Electrochemical Detection of Nucleic Acids
Wei, F., Lillehoj, P. B., & Ho, C. (2010) · Pediatric Research · doi:10.1203/pdr.0b013e3181d361c3 · Cited by 144
Label‐Free Sensing of Biomolecules with Field‐Effect Devices for Clinical Applications
Poghossian, A., & Schöning, M. J. (2014) · Electroanalysis · doi:10.1002/elan.201400073 · Cited by 142
Biologically sensitive field-effect transistors: from ISFETs to NanoFETs
Pachauri, V., & Ingebrandt, S. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150009 · Cited by 140
Enzyme biosensors based on ion-selective field-effect transistors
Dzyadevych, S. V., Soldatkin, A. P., El'skaya, A. V., Martelet, C., & Jaffrezic-Renault, N. J. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.057 · Cited by 137
Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors
Spijkman, M., Smits, E. C. P., Cillessen, J. F. M., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2011) · Applied Physics Letters · doi:10.1063/1.3546169 · Cited by 135
Highly specific SNP detection using 2D graphene electronics and DNA strand displacement
Hwang, M. T., Landon, P. B., Lee, J., Choi, D. Y., Mo, A. H., Glinsky, G. V., & Lal, R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1603753113 · Cited by 134
Electrophoretic and field-effect graphene for all-electrical DNA array technology
Xu, G., Abbott, J., Qin, L., Yeung, K. Y. M., Song, Y., Yoon, H., Kong, J., & Ham, D. (2014) · Nature Communications · doi:10.1038/ncomms5866 · Cited by 126
Schasfoort, R. B. M., Bergveld, P., Kooyman, R. P. H., & Greve, J. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80554-1 · Cited by 123
Ingebrandt, S., Han, Y., Nakamura, F., Poghossian, A., Schöning, M. J., & Offenhäusser, A. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.11.019 · Cited by 122
A potentiometric biosensor for rapid on-site disease diagnostics
Tarasov, A., Gray, D. W., Tsai, M.-Y., Shields, N., Montrose, A., Creedon, N., Lovera, P., O'Riordan, A. J., Mooney, M. H., & Vogel, E. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.086 · Cited by 109
Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution
Song, K.-S., Zhang, G.-J., Nakamura, Y., Furukawa, K., Hiraki, T., Yang, J.-H., Funatsu, T., Ohdomari, I., & Kawarada, H. (2006) · Physical Review E · doi:10.1103/physreve.74.041919 · Cited by 104
Jang, H.-J., & Cho, W.-J. (2014) · Scientific Reports · doi:10.1038/srep05284 · Cited by 103
Electrochemical processes and mechanistic aspects of field-effect sensors for biomolecules
Huang, W., Diallo, A. K., Dailey, J., Besar, K., & Katz, H. E. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00755k · Cited by 102
Aptamer-based Field-Effect Biosensor for Tenofovir Detection
Aliakbarinodehi, N., Jolly, P., Bhalla, N., Miodek, A., Micheli, G. D., Estrela, P., & Carrara, S. (2017) · Scientific Reports · doi:10.1038/srep44409 · Cited by 90
ISFET pH Sensitivity: Counter-Ions Play a Key Role
Parizi, K. B., Xu, X., Pal, A., Hu, X., & Wong, H. ‐. P. (2017) · Scientific Reports · doi:10.1038/srep41305 · Cited by 86
Scaling issues in chemical and biological sensors
Madou, M. J., & Cubicciotti, R. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813577 · Cited by 83
A Highly Responsive Silicon Nanowire/Amplifier MOSFET Hybrid Biosensor
Lee, J., Jang, J., Choi, B., Yoon, J., Kim, J.-Y., Choi, Y., Kim, D. M., Kim, D. H., & Choi, S. (2015) · Scientific Reports · doi:10.1038/srep12286 · Cited by 80
Label-Free DNA Sensing Platform with Low-Voltage Electrolyte-Gated Transistors
White, S. P., Dorfman, K. D., & Frisbie, C. D. (2015) · Analytical Chemistry · doi:10.1021/ac503914x · Cited by 79
An Integrated ISFET Sensor Array
Nakazato, K. (2009) · Sensors · doi:10.3390/s91108831 · Cited by 77
Liu, Y., Georgiou, P., Prodromakis, T., Constandinou, T. G., & Toumazou, C. (2011) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2011.2168821 · Cited by 75
CMOS Amperometric Instrumentation and Packaging for Biosensor Array Applications
Li, L., Liu, X., Qureshi, W. A., & Mason, A. J. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2171339 · Cited by 72
Electrofluidic Gating of a Chemically Reactive Surface
Jiang, Z., & Stein, D. (2010) · Langmuir · doi:10.1021/la9044682 · Cited by 70
Diffuse Double Layer at Nanoelectrodes
Dickinson, E. J. F., & Compton, R. G. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp906404h · Cited by 69
Hybrid Integrated Label-Free Chemical and Biological Sensors
Mehrabani, S., Maker, A. J., & Armani, A. M. (2014) · Sensors · doi:10.3390/s140405890 · Cited by 67
Device characteristics of polymer dual-gate field-effect transistors
Maddalena, F., Spijkman, M.-J., Brondijk, J. J., Fonteijn, P., Brouwer, F., Hummelen, J. C., de Leeuw, D. M., Blom, P. W. M., & de Boer, B. (2008) · Organic Electronics · doi:10.1016/j.orgel.2008.06.004 · Cited by 67
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
Low frequency noise and drift in Ion Sensitive Field Effect Transistors
Jakobson, C. G., Feinsod, M., & Nemirovsky, Y. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00473-1 · Cited by 65
A System-on-Chip Digital pH Meter for Use in a Wireless Diagnostic Capsule
Hammond, P. A., Ali, D., & Cumming, D. R. S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844041 · Cited by 63
1/f noise in ion sensitive field effect transistors from subthreshold to saturation
Jakobson, C. G., & Nemirovsky, Y. (1999) · IEEE Transactions on Electron Devices · doi:10.1109/16.737468 · Cited by 62
A large transistor-based sensor array chip for direct extracellular imaging
Milgrew, M. J., Riehle, M. O., & Cumming, D. R. S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.01.020 · Cited by 60
Extended-gate FET-based enzyme sensor with ferrocenyl-alkanethiol modified gold sensing electrode
Ishige, Y., Shimoda, M., & Kamahori, M. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.012 · Cited by 59
Jang, H., Ahn, J., Kim, M., Shin, Y., Jeun, M., Cho, W.-J., & Lee, K. H. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.020 · Cited by 59
An Ion-Sensitive Floating Gate FET Model: Operating Principles and Electrofluidic Gating
Kaisti, M., Zhang, Q., Prabhu, A., Lehmusvuori, A., Rahman, A., & Levón, K. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2441878 · Cited by 58
Self-citationTime-dependent observation of individual cellular binding events to field-effect transistors
Schäfer, S., Eick, S., Hofmann, B., Dufaux, T., Stockmann, R., Wrobel, G., Offenhäusser, A., & Ingebrandt, S. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.003 · Cited by 56
CMOS biosensors for in vitro diagnosis – transducing mechanisms and applications
Lei, K., Mak, P., Law, M. K., & Martins, R. P. (2016) · Lab on a Chip · doi:10.1039/c6lc01002d · Cited by 55
Kim, J.-Y., Choi, K., Moon, D., Ahn, J., Park, T. J., Lee, S. Y., & Choi, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.036 · Cited by 54
Dimension and Shape Effects on the ISFET Performance
Sohbati, M., & Toumazou, C. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2365291 · Cited by 52
Zhang, Q., Majumdar, H. S., Kaisti, M., Prabhu, A., Ivaska, A. U., Österbacka, R., Rahman, A., & Levón, K. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2396996 · Cited by 51
Self-citationLiu, Y., & Dutton, R. W. (2009) · Journal of Applied Physics · doi:10.1063/1.3156657 · Cited by 51
Label-Free Potentiometry for Detecting DNA Hybridization Using Peptide Nucleic Acid and DNA Probes
Goda, T., Singi, A., Maeda, Y., Matsumoto, A., Torimura, M., Aoki, H., & Miyahara, Y. (2013) · Sensors · doi:10.3390/s130202267 · Cited by 49
Rapid Detection of E. coli Bacteria Using Potassium-Sensitive FETs in CMOS
Nikkhoo, N., Gulak, P. G., & Maxwell, K. L. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2276013 · Cited by 46
Shen, N. Y.-M., Liu, Z., Lee, C., Minch, B. A., & Kan, E. C.-C. (2003) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2003.816905 · Cited by 45
Enhanced Biosensing Resolution with Foundry Fabricated Individually Addressable Dual-Gated ISFETs
Duarte-Guevara, C., Lai, F.-L., Cheng, C.-W., Reddy, B., Salm, E. M., Swaminathan, V. V., Tsui, Y.-K., Tuan, H. C., Kalnitsky, A., Liu, Y.-S., et al. (2014) · Analytical Chemistry · doi:10.1021/ac501912x · Cited by 45
Screening model for nanowire surface-charge sensors in liquid
Sørensen, M. H., Mortensen, N. A., & Brandbyge, M. (2007) · Applied Physics Letters · doi:10.1063/1.2779930 · Cited by 43
Hand-Held Transistor Based Electrical and Multiplexed Chemical Sensing System
Kaisti, M., Boeva, Z. A., Koskinen, J., Nieminen, S., Bobacka, J., & Levón, K. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00520 · Cited by 43
Self-citationSusloparova, A., Koppenhöfer, D., Law, J. K. Y., Vu, X. T., & Ingebrandt, S. (2014) · Lab on a Chip · doi:10.1039/c4lc00593g · Cited by 42
Jain, A., Nair, P. R., & Alam, M. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1203749109 · Cited by 40
A Low Power Sub- $\mu$ W Chemical Gilbert Cell for ISFET Differential Reaction Monitoring
Kalofonou, M., & Toumazou, C. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282894 · Cited by 38
High-Frequency Nanocapacitor Arrays: Concept, Recent Developments, and Outlook
Lemay, S. G., Laborde, C., Renault, C., Cossettini, A., Selmi, L., & Widdershoven, F. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00349 · Cited by 38
Ishige, Y., Shimoda, M., & Kamahori, M. (2006) · Japanese Journal of Applied Physics · doi:10.1143/jjap.45.3776 · Cited by 37
Experimental and Simulated Cycling of ISFET Electric Fields for Drift Reset
WELCH, D. F., Shah, S. S., Ozev, S., & Christen, J. B. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2240648 · Cited by 37
Odijk, M., van der Wouden, E. J., Olthuis, W., Ferrari, M. D., Tolner, E. A., van den Maagdenberg, A. M. J. M., & van den Berg, A. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.06.138 · Cited by 34
Kamahori, M., Ishige, Y., & Shimoda, M. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.013 · Cited by 31
Rapid detection of E.Coli bacteria using potassium-sensitive FETs in CMOS
Nikkhoo, N., Gulak, P. G., & Maxwell, K. L. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418470 · Cited by 30
Programmable ion-sensitive transistor interfaces. II. Biomolecular sensing and manipulation
Jayant, K., Auluck, K., Funke, M., Anwar, S., Phelps, J. B., Gordon, P. H., Rajwade, S., & Kan, E. C.-C. (2013) · Physical Review E · doi:10.1103/physreve.88.012802 · Cited by 29
Quantitative probing of surface charges at dielectric–electrolyte interfaces
Guan, W., Rajan, N. K., Duan, X., & Reed, M. A. (2013) · Lab on a Chip · doi:10.1039/c3lc41351a · Cited by 25
De, A., Souchelnytskyi, S., van den Berg, A., & Carlen, E. T. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4011429 · Cited by 25
A Low-Cost Disposable Chemical Sensing Platform Based on Discrete Components
Prodromakis, T., Liu, Y., & Toumazou, C. (2011) · IEEE Electron Device Letters · doi:10.1109/led.2010.2099098 · Cited by 24
Ingebrandt, S. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.199 · Cited by 24
Programmable ion-sensitive transistor interfaces. I. Electrochemical gating
Jayant, K., Auluck, K., Funke, M., Anwar, S., Phelps, J. B., Gordon, P. H., Rajwade, S., & Kan, E. C.-C. (2013) · Physical Review E · doi:10.1103/physreve.88.012801 · Cited by 24
Application of ion-sensitive field effect transistors for ion channel screening
Walsh, K. B., DeRoller, N., Zhu, Y., & Koley, G. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.038 · Cited by 21
Nanowire Field-Effect Transistor Sensors
Zhang, A., Zheng, G., & Lieber, C. M. (2016) · Nanoscience and technology · doi:10.1007/978-3-319-41981-7_10 · Cited by 16
Potentiometric, Amperometric, and Impedimetric CMOS Biosensor Array
Nakazato, K. (2013) · InTech eBooks · doi:10.5772/53319 · Cited by 12
Jayant, K., Singhai, A., Cao, Y., Phelps, J. B., Lindau, M., Holowka, D. A., Baird, B. A., & Kan, E. C.-C. (2015) · Scientific Reports · doi:10.1038/srep18477 · Cited by 8
Controlling Field‐Effect Transistor Biosensor Electrical Characteristics Using Immunosorbent Assay
Vaknin, O., Khamaisi, B., Mizrahi, M., & Ashkenasy, N. (2011) · Electroanalysis · doi:10.1002/elan.201100250 · Cited by 2
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Hajian, R., Balderston, S., Tran, T., deBoer, T., Etienne, J., Sandhu, M., Wauford, N. A., Chung, J.-Y., Nokes, J., Athaiya, M., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0371-x · Cited by 646
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Metal oxide nanostructures for sensor applications
Nunes, D., Pimentel, A., Gonçalves, A., Pereira, S., Branquinho, R., Barquinha, P., Fortunato, E., & Martins, R. (2019) · Semiconductor Science and Technology · doi:10.1088/1361-6641/ab011e · Cited by 354
Metadata
- Authors
- Kaisti, M.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 98
- Pages
- 437-448
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2725266022
- Cited by
- 577
- References
- 111
- FWCI
- 35.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.