The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
A wearable electrochemical glucose sensor based on simple and low-cost fabrication supported micro-patterned reduced graphene oxide nanocomposite electrode on flexible substrate
Abstract
In this study, a reduced graphene oxide (rGO)-based nanostructured composite working electrode of high quality was successfully microfabricated and micro-patterned on a flexible polyimide substrate using simple low-cost fabrication processes. Gold and platinum alloy nanoparticles were electrochemically deposited onto the microfabricated rGO surface and chitosan-glucose oxidase composites were integrated onto the modified surface of the working electrode to develop a human sweat-based wearable glucose sensor application. The fabricated biosensor exhibited excellent amperometric response to glucose at a detection range of 0-2.4 mM (covers the glucose range in sweat), with a sensitivity of 48 μA/mMcm2, a short response time (20 s), and high linearity (0.99). The detection limit for glucose was calculated as 5 µm. The human sweat/mixing glucose samples initially used for testing indicated acceptable detection performance and stability for low glucose concentrations. These results confirm that the proposed nanostructured composite flexible working electrode and fabrication process are highly promising for application as human sweat-based electrochemical glucose sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Yang, D., Velamakanni, A., Bozoklu, G., Park, S., Stoller, M., Piner, R. D., Stankovich, S., Jung, I., Field, D. A., Ventrice, C. A., et al. (2009) · Carbon · doi:10.1016/j.carbon.2008.09.045 · Cited by 3,260
Kovtyukhova, N. I., Ollivier, P. J., Martin, B. R., Mallouk, T. E., Chizhik, S. A., Buzaneva, E. V., & Gorchinskiy, A. D. (1999) · Chemistry of Materials · doi:10.1021/cm981085u · Cited by 3,240
New insights into the structure and reduction of graphite oxide
Gao, W., Alemany, L. B., Ci, L., & Ajayan, P. M. (2009) · Nature Chemistry · doi:10.1038/nchem.281 · Cited by 2,583
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Fan, X., Peng, W., Li, Y., Li, X., Wang, S., Zhang, G., & Zhang, F. (2008) · Advanced Materials · doi:10.1002/adma.200801306 · Cited by 1,772
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Renteria, J. D., Ramirez, S., Malekpour, H., Alonso, B., Centeno, A., Zurutuza, A., Cocemasov, A. I., Nika, D. L., & Balandin, A. A. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501429 · Cited by 579
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Metadata
- Authors
- Xuan, X., Yoon, H. S., & Park, J. Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 109
- Pages
- 75-82
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2789539283
- Cited by
- 410
- References
- 28
- FWCI
- 15.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wearable electrochemical glucose sensor based on simple and low-cost fabrication supported micro-patterned reduced graphene oxide nanocomposite electrode on flexible substrate. https://app.cochat.ai/papers/10.1016/j.bios.2018.02.054
- The paper
- Xuan, X., Yoon, H. S., & Park, J. Y. (2018). A wearable electrochemical glucose sensor based on simple and low-cost fabrication supported micro-patterned reduced graphene oxide nanocomposite electrode on flexible substrate. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.02.054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.