CoChat

CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat

Open access
Bhide, Ashlesha, Muthukumar, Sriram, Prasad, Shalini · 2018 · Biosensors and Bioelectronics
Cited by 64

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Wearable- IOT based low- cost platforms can enable dynamic lifestyle monitoring through enabling promising and exciting opportunities for wellness and chronic- disease management in personalized environments. Diabetic and pre- diabetic populations can modulate their alcohol intake by tracking their glycemic content continuously to prevent health risks through these platforms. We demonstrate the first technological proof of a combinatorial biosensor for continuous, dynamic monitoring of alcohol and glucose in ultra- low volumes (1– 5μL) of passive perspired sweat towards developing a wearable- IOT based platform. Non-invasive biosensing in sweat is achieved by a unique gold- zinc oxide (ZnO) thin film electrode stack fabricated on a flexible substrate suitable for wearable applications. The active ZnO sensing region is immobilized with enzyme complexes specific for the detection of alcohol and glucose through non- faradaic electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). Biomolecular interactions occurring at the electrode- sweat interface are represented by the impedance and capacitive current changes in response to charge modulations arising in the double layer. We also report the detection of alcohol concentrations of 0.01– 100 mg/dl and glucose concentrations of 0.01– 50 mg/dl present in synthetic sweat and perspired human sweat. The limit of detection obtained for alcohol and glucose was found to be 0.1 mg/dl in perspired human sweat. Cross- reactivity studies revealed that glucose and alcohol did not show any signal response to cross- reactive molecules. Furthermore, the stable temporal response of the combinatorial biosensor on continuous exposure to passive perspired human sweat spiked with alcohol and glucose over a 120-minute duration was demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2018.06.065

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 64

Metadata

Authors
Bhide, A., Muthukumar, S., & Prasad, S.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2018-10
Volume
117
Pages
537-545
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2810182320
Cited by
64
References
9
FWCI
2.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat. https://app.cochat.ai/papers/10.1016/j.bios.2018.06.065
The paper
Bhide, A., Muthukumar, S., & Prasad, S. (2018). CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.06.065

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.