CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Wearable- IOT based low- cost platforms can enable dynamic lifestyle monitoring through enabling promising and exciting opportunities for wellness and chronic- disease management in personalized environments. Diabetic and pre- diabetic populations can modulate their alcohol intake by tracking their glycemic content continuously to prevent health risks through these platforms. We demonstrate the first technological proof of a combinatorial biosensor for continuous, dynamic monitoring of alcohol and glucose in ultra- low volumes (1– 5μL) of passive perspired sweat towards developing a wearable- IOT based platform. Non-invasive biosensing in sweat is achieved by a unique gold- zinc oxide (ZnO) thin film electrode stack fabricated on a flexible substrate suitable for wearable applications. The active ZnO sensing region is immobilized with enzyme complexes specific for the detection of alcohol and glucose through non- faradaic electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). Biomolecular interactions occurring at the electrode- sweat interface are represented by the impedance and capacitive current changes in response to charge modulations arising in the double layer. We also report the detection of alcohol concentrations of 0.01– 100 mg/dl and glucose concentrations of 0.01– 50 mg/dl present in synthetic sweat and perspired human sweat. The limit of detection obtained for alcohol and glucose was found to be 0.1 mg/dl in perspired human sweat. Cross- reactivity studies revealed that glucose and alcohol did not show any signal response to cross- reactive molecules. Furthermore, the stable temporal response of the combinatorial biosensor on continuous exposure to passive perspired human sweat spiked with alcohol and glucose over a 120-minute duration was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“…bioelectronic devices capable of detecting electrolytes, glucose, and lactate in smallvolumes of sweat using amperometric techniques have been demonstrated previously (Azevedo et al., 2005) (Gao et al., 2016) (Anastasova et al., 2017) (Jia et al., 2013) (Thomas et al., 2012) (Abrar et al., 2016).”
MethodLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · cited 1×
“The typical sweat glucose concentrations corresponding to hypoglycemic, normal, and hyperglycemic lie within the range 0.85– 5.5 mg/dl (Lee et al., 2016).”
BackgroundInfluentialElectrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443 · cited 1×
“…bioelectronic devices capable of detecting electrolytes, glucose, and lactate in smallvolumes of sweat using amperometric techniques have been demonstrated previously (Azevedo et al., 2005) (Gao et al., 2016) (Anastasova et al., 2017) (Jia et al., 2013) (Thomas et al., 2012) (Abrar et al., 2016).”
MethodNon‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Munje, R. D., Muthukumar, S., & Prasad, S. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.07.088 · Cited by 190 · cited 2×
“The details on fabrication of the electrode stack have been outlined in the previous work (Munje et al., 2017).”
MethodSelf-citationGamella, M., Campuzano, S., Manso, J., Rivera, G. G. D., López-Colino, F., Reviejo, A. J., & Pingarrón, J. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.020 · Cited by 140 · cited 2×
“Literature studies show clinical correlations between sweat analyte and blood analyte levels which confirm that there is value in investigating sweat of wellness and disease management (Moyer et al., 2012) (Gamella et al., 2014).”
BackgroundInfluential
Cited by
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
Revisiting the Use of Biological Fluids for Noninvasive Glucose Detection
Zhao, M., & Leung, P. S. (2020) · Future Medicinal Chemistry · doi:10.4155/fmc-2020-0019 · Cited by 16
Metadata
- Authors
- Bhide, A., Muthukumar, S., & Prasad, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 117
- Pages
- 537-545
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2810182320
- Cited by
- 64
- References
- 9
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat. https://app.cochat.ai/papers/10.1016/j.bios.2018.06.065
- The paper
- Bhide, A., Muthukumar, S., & Prasad, S. (2018). CLASP (Continuous lifestyle awareness through sweat platform): A novel sensor for simultaneous detection of alcohol and glucose from passive perspired sweat. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.06.065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.