Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.

Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions

Open access
Adeel, Muhammad, Rahman, Md. Mahbubur, Caligiuri, Isabella, Canzonieri, Vincenzo, Rizzolio, Flavio, Daniele, Salvatore·2020·Biosensors and Bioelectronics

Abstract

Diabetes is a pathological condition that requires the continuous monitoring of glucose level in the blood. Its control has been tremendously improved by the application of point-of-care devices. Conventional enzyme-based sensors with electrochemical and optical transduction systems can successfully measure the glucose concentration in human blood, but they suffer from the low stability of the enzyme. Non-enzymatic wearable electrochemical and optical sensors, with low-cost, high stability, point-of-care testing and online monitoring of glucose levels in biological fluids, have recently been developed and can help to manage and control diabetes worldwide. Advances in nanoscience and nanotechnology have enabled the development of novel nanomaterials that can be implemented for the use in enzyme-free systems to detect glucose. This review summarizes recent developments of enzyme-free electrochemical and optical glucose sensors, as well as their respective wearable and commercially available devices, capable of detecting glucose at physiological pH conditions without the need to pretreat the biological fluids. Additionally, the evolution of electrochemical glucose sensor technology and a couple of widely used optical detection systems along with the glucose detection mechanism is also discussed. Finally, this review addresses limitations and challenges of current non-enzymatic electrochemical, optical, and wearable glucose sensor technologies and highlights opportunities for future research directions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112331

Cites

116 of 116 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 116 references

Research works printed but not linked: 14

  1. Ansari, 2019, Conducting poly(aniline blue)-gold nanoparticles composite modified fluorine-doped tin oxide electrode for sensitive and non-enzymatic electrochemical detection of glucose., J. Electroanal. Chem., 850, 113394, 10.1016/j.jelechem.2019.113394 · doi:10.1016/j.jelechem.2019.113394
  2. Branagan, 2019, Electrochemical detection of glucose at physiological pH using gold nanoparticles deposited on carbon nanotubes, Sensor. Actuator. B Chem., 282, 490, 10.1016/j.snb.2018.11.089 · doi:10.1016/j.snb.2018.11.089
  3. Cordes, 2005, Optical glucose detection across the visible spectrum using anionic fluorescent dyes and a viologen quencher in a two-component saccharide sensing system, Org. Biomol. Chem., 3, 1708, 10.1039/b418953a · doi:10.1039/b418953a
  4. Krishna, 2016, Carbon dot based non enzymatic approach for the detection and estimation of glucose in blood serum, Mater. Res. Express, 3, 10.1088/2053-1591/3/5/055001 · doi:10.1088/2053-1591/3/5/055001
  5. Li, 2014, One-pot ionic liquid-assisted synthesis of highly dispersed PtPd nanoparticles/reduced graphene oxide composites for nonenzymatic glucose detection, Biosens. Bioelectron., 56, 223, 10.1016/j.bios.2014.01.030 · doi:10.1016/j.bios.2014.01.030
  6. Lopa, 2018, A base-stable metal-organic framework for sensitive and non-enzymatic electrochemical detection of hydrogen peroxide, Electrochim. Acta, 274, 49, 10.1016/j.electacta.2018.03.148 · doi:10.1016/j.electacta.2018.03.148
  7. Mai, 2019, Non-enzymatic fluorescent glucose sensor using vertically aligned ZnO nanotubes grown by a one-step, seedless hydrothermal method, Microchim. Acta, 186, 245, 10.1007/s00604-019-3353-5 · doi:10.1007/s00604-019-3353-5
  8. Mitsou, 2017, Oxidation catalysis by enzymes in microemulsions, Catalysts, 7, 52, 10.3390/catal7020052 · doi:10.3390/catal7020052
  9. Rauf, 2016, Nano-engineered biomimetic optical sensors for glucose monitoring in diabetes, Sensors, 10.3390/s16111931 · doi:10.3390/s16111931
  10. Sato, 2001, Electrochemical glucose sensors and their applications in diabetes management, Chem. Rev., 108, 2482
  11. Wang, 2018, An alkaline and surfactant-tolerant lipase from Trichoderma lentiforme ACCC30425 with high application potential in the detergent industry, Amb. Express, 8, 95, 10.1186/s13568-018-0618-z · doi:10.1186/s13568-018-0618-z
  12. Wang, 2012, Optical probe for d-glucose based on cationic polymer quencher/receptor and anionic dye in aqueous solution, Sensor. Actuator. B Chem., 163, 202, 10.1016/j.snb.2012.01.036 · doi:10.1016/j.snb.2012.01.036
  13. Wu, 2018, Facile preparation of PtNPs/BSA-RGO nanostructure for non-enzymatic glucose electrochemical sensing, Int. J. Electrochem. Sci., 13, 9784, 10.20964/2018.10.50 · doi:10.20964/2018.10.50
  14. Zang, 2018, Copper nanowires-MOFs-graphene oxide hybrid nanocomposite targeting glucose electro-oxidation in neutral medium, Electrochim. Acta, 277, 176, 10.1016/j.electacta.2018.05.016 · doi:10.1016/j.electacta.2018.05.016

Cited by

See all 327

Metadata

Authors
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2020-10
Volume
165
Pages
112331
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3032779279
Cited by
327
References
116
FWCI
16.46
Type
journal article
Language
en
Open access
green
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
Università Ca' Foscari di Venezia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions. https://app.cochat.ai/papers/10.1016/j.bios.2020.112331
The paper
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S. (2020). Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.