The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions
Open accessAbstract
Diabetes is a pathological condition that requires the continuous monitoring of glucose level in the blood. Its control has been tremendously improved by the application of point-of-care devices. Conventional enzyme-based sensors with electrochemical and optical transduction systems can successfully measure the glucose concentration in human blood, but they suffer from the low stability of the enzyme. Non-enzymatic wearable electrochemical and optical sensors, with low-cost, high stability, point-of-care testing and online monitoring of glucose levels in biological fluids, have recently been developed and can help to manage and control diabetes worldwide. Advances in nanoscience and nanotechnology have enabled the development of novel nanomaterials that can be implemented for the use in enzyme-free systems to detect glucose. This review summarizes recent developments of enzyme-free electrochemical and optical glucose sensors, as well as their respective wearable and commercially available devices, capable of detecting glucose at physiological pH conditions without the need to pretreat the biological fluids. Additionally, the evolution of electrochemical glucose sensor technology and a couple of widely used optical detection systems along with the glucose detection mechanism is also discussed. Finally, this review addresses limitations and challenges of current non-enzymatic electrochemical, optical, and wearable glucose sensor technologies and highlights opportunities for future research directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2012) · Diabetes Care · doi:10.2337/dc12-s064 · Cited by 1,491
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Damborský, P., Švitel, J., & Katrlík, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150010 · Cited by 907
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Self-citationShen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Metal oxide nanoparticles in electrochemical sensing and biosensing: a review
George, J. M., Antony, A., & Mathew, B. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2894-3 · Cited by 580
Metal-organic frameworks for direct electrochemical applications
Xu, Y., Li, Q., Xue, H., & Pang, H. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.08.010 · Cited by 557
A review of recent advances in nonenzymatic glucose sensors
Tian, K., Prestgard, M., & Tiwari, A. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.04.013 · Cited by 546
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
Skin-Attachable, Stretchable Electrochemical Sweat Sensor for Glucose and pH Detection
Oh, S. Y., Hong, S. Y., Jeong, Y. R., Yun, J., Park, H., Jin, S. W., Lee, G., Oh, J. H., Lee, H., Lee, S.-S., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03342 · Cited by 440
Gao, H., Xiao, F., Ching, C. B., & Duan, H. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200563f · Cited by 383
Zhang, L., Zhang, Z.-Y., Liang, R.-P., Li, Y.-H., & Qiu, J.-D. (2014) · Analytical Chemistry · doi:10.1021/ac500289c · Cited by 382
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Nanosensors and nanomaterials for monitoring glucose in diabetes
Cash, K. J., & Clark, H. A. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.08.002 · Cited by 369
Murea, M., Ma, L., & Freedman, B. I. (2012) · The Review of Diabetic Studies · doi:10.1900/rds.2012.9.6 · Cited by 366
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Li, Y., Xie, M., Zhang, X., Liu, Q., Lin, D., Xu, C., Xie, F., & Sun, X. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.076 · Cited by 354
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
Xiao, F., Zhao, F., Mei, D., Mo, Z., & Zeng, B. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.045 · Cited by 344
Recent progress in multienzymes co-immobilization and multienzyme system applications
Ren, S., Li, C., Jiao, X., Jia, S., Jiang, Y., Bilal, M., & Cui, J. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.05.141 · Cited by 342
Electrochemical biosensors - principles and applications
Pohanka, M., & Skládal, P. (2008) · Journal of Applied Biomedicine · doi:10.32725/jab.2008.008 · Cited by 341
Combinatorial Discovery of Alloy Electrocatalysts for Amperometric Glucose Sensors
Sun, Y., Buck, H., & Mallouk, T. E. (2001) · Analytical Chemistry · doi:10.1021/ac0015117 · Cited by 306
Xiao, J., Liu, Y., Su, L., Zhao, D., Zhao, L., & Zhang, X. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03110 · Cited by 288
Niu, X., Li, X., Pan, J., He, Y., Qiu, F., & Yan, Y. (2016) · RSC Advances · doi:10.1039/c6ra12506a · Cited by 275
Cui, H.-F., Ye, J.-S., Zhang, W.-D., Li, C.-M., Luong, J. H. T., & Sheu, F.-S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.05.047 · Cited by 254
Glucose-Sensitive Inverse Opal Hydrogels: Analysis of Optical Diffraction Response
Lee, Y.-J., Pruzinsky, S. A., & Braun, P. V. (2004) · Langmuir · doi:10.1021/la035555x · Cited by 252
Nanogold-plasmon-resonance-based glucose sensing
Aslan, K., Lakowicz, J. R., & Geddes, C. D. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.03.032 · Cited by 244
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Bae, C. W., Toi, P. T., Kim, B. Y., Lee, W. I., Lee, H. B., Hanif, A., Lee, E. H., & Lee, N.-E. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b00848 · Cited by 215
Glucose Sensing with Phenylboronic Acid Functionalized Hydrogel-Based Optical Diffusers
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.7b07082 · Cited by 210
Cordes, D. B., Gamsey, S., & Singaram, B. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504390 · Cited by 204
Wu, G.-H., Song, X.-H., Wu, Y.-F., Chen, X.-M., Luo, F., & Chen, X. (2013) · Talanta · doi:10.1016/j.talanta.2012.10.066 · Cited by 194
Fu, S., Fan, G., Yang, L., & Li, F. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2014.11.115 · Cited by 181
Kabilan, S., Marshall, A. J., Sartain, F. K., Lee, M.-C., Hussain, A., Yang, X., Blyth, J., Karangu, N., James, K., Zeng, J., et al. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.005 · Cited by 168
Toi, P. T., Trung, T. Q., Dang, T. M. L., Bae, C. W., & Lee, N. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b20583 · Cited by 159
Xiao, F., Li, Y., Gao, H., Ge, S., & Duan, H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.062 · Cited by 158
(110)-Exposed Gold Nanocoral Electrode as Low Onset Potential Selective Glucose Sensor
Cheng, T.-M., Huang, T.-K., Lin, H.-K., Tung, S.-P., Chen, Y.-L., Lee, C. Y., & Chiu, H. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100432a · Cited by 155
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154
Microfluidic Surface Plasmon Resonance Sensors: From Principles to Point-of-Care Applications
Wang, D.-S., & Fan, S. (2016) · Sensors · doi:10.3390/s16081175 · Cited by 153
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Analytical Chemistry · doi:10.1021/ac0303721 · Cited by 152
Larin, K. V., Motamedi, M., Ashitkov, T. V., & Esenaliev, R. O. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/310 · Cited by 147
Yuan, H., Ji, W., Chu, S., Qian, S., Wang, F., Masson, J., Han, X., & Peng, W. B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.042 · Cited by 146
Huang, J., Zhu, Y., Yang, X., Chen, W., Zhou, Y., & Li, C. (2014) · Nanoscale · doi:10.1039/c4nr05620e · Cited by 144
Ryu, J. E., Kim, K.-H., Kim, H., Hahn, H. T., & Lashmore, D. S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.021 · Cited by 143
kumar, G. G., Amala, G., & Gowtham, S. M. (2017) · RSC Advances · doi:10.1039/c7ra02845h · Cited by 142
Overview of Fluorescence Glucose Sensing: A Technology with a Bright Future
Klonoff, D. C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600602 · Cited by 138
Wang, H., Yi, J., Velado, D., Yu, Y., & Zhou, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04744 · Cited by 137
A review of optical methods for continuous glucose monitoring
Jernelv, I. L., Mileńko, K., Fuglerud, S. S., Hjelme, D. R., Ellingsen, R., & Aksnes, A. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1486324 · Cited by 137
Chang, G., Shu, H., Huang, Q., Oyama, M., Ji, K., Liu, X., & He, Y. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.01.085 · Cited by 135
A non-enzymatic glucose sensor enabled by bioelectronic pH control
Strakosas, X., Selberg, J. A., Pansodtee, P., Yonas, N., Manapongpun, P., Teodorescu, M., & Rolandi, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-46302-9 · Cited by 133
Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions
Mohapatra, J., Ananthoju, B., Nair, V., Mitra, A., Bahadur, D., Medhekar, N. V., & Aslam, M. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.02.124 · Cited by 130
Linear and Fast Hydrogel Glucose Sensor Materials Enabled by Volume Resetting Agents
Zhang, C., Cano, G. G., & Braun, P. V. (2014) · Advanced Materials · doi:10.1002/adma.201401710 · Cited by 128
Fundamentals, achievements and challenges in the electrochemical sensing of pathogens
Monzó, J., Insua, I., Fernández‐Trillo, F., & Rodríguez, P. (2015) · The Analyst · doi:10.1039/c5an01330e · Cited by 120
Yang, J., Liang, X., Cui, L., Liu, H., Xie, J., & Liu, W. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.056 · Cited by 120
Rathod, D. G., Dickinson, C., Egan, D. A., & Dempsey, E. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.09.064 · Cited by 118
Wu, W., Shen, J., Li, Y., Zhu, H., Banerjee, P., & Zhou, S. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.031 · Cited by 115
Ismail, N. S., Hoa, L. Q., Yoshikawa, H., Saito, M., & Tamiya, E. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.08.123 · Cited by 113
Hydrogel optical fibers for continuous glucose monitoring
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.05.002 · Cited by 112
Electrochemically roughened nanoporous platinum electrodes for non-enzymatic glucose sensors
Weremfo, A., Fong, S. T. C., Khan, A. L., Hibbert, D. B., & Zhao, C. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.02.018 · Cited by 111
Zhu, X., Yuan, S., Ju, Y., Yang, J. H., Zhao, C., & Liu, H. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02328 · Cited by 105
Three-dimensional porous Cu@Cu2O aerogels for direct voltammetric sensing of glucose
Gao, Y., Yang, F., Yu, Q., Fan, R., Yang, M., Rao, S., Lan, Q., Yang, Z., & Yang, Z. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3263-6 · Cited by 104
Non-enzymatic D-glucose plasmonic optical fiber grating biosensor
Lobry, M., Lahem, D., Loyez, M., Debliquy, M., Chah, K., David, M., & Caucheteur, C. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111506 · Cited by 104
Bollella, P., Gorton, L. G. O., Ludwig, R., & Antiochia, R. (2017) · Sensors · doi:10.3390/s17081912 · Cited by 103
PtAu/C based bimetallic nanocomposites for non-enzymatic electrochemical glucose detection
Singh, B., Laffir, F. R., McCormac∥, T., & Dempsey, E. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.07.039 · Cited by 100
Au decorated core-shell structured Au@Pt for the glucose oxidation reaction
Shim, K., Lee, W.-C., Park, M., Shahabuddin, M., Yamauchi, Y., Hossain, M. S. A., Shim, Y., & Kim, J. H. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.048 · Cited by 99
Zhang, W., Du, Y., & Wang, M. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.04.006 · Cited by 97
Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S., & Allen, M. G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.013 · Cited by 95
du Toit, H., & Lorenzo, M. D. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.06.074 · Cited by 92
Wearable, robust, non-enzymatic continuous glucose monitoring system and its in vivo investigation
Yoon, H., Xuan, X., Jeong, S., & Park, J. Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.008 · Cited by 92
A 2-D photonic crystal hydrogel for selective sensing of glucose
Xue, F., Meng, Z., Wang, F., Wang, Q., Xue, M., & Xu, Z. (2014) · Journal of Materials Chemistry A · doi:10.1039/c4ta01031k · Cited by 87
A Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose
Ruan, J.-L., Chen, C., Shen, J., Zhao, X., Qian, S., & Zhu, Z. (2017) · Polymers · doi:10.3390/polym9040125 · Cited by 86
Niu, X., Shi, L., Zhao, H., & Lan, M. (2016) · Analytical Methods · doi:10.1039/c5ay03181h · Cited by 80
Metal–Organic Frameworks Toward Electrocatalytic Applications
Li, J.-H., Wang, Y.-S., Chen, Y.-C., & Kung, C. (2019) · Applied Sciences · doi:10.3390/app9122427 · Cited by 78
He, W., Sun, Y., Xi, J., Abdurhman, A. A. M., Ren, J., & Duan, H. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.019 · Cited by 77
Hsu, C.-W., Su, F.-C., Peng, P.-Y., Young, H., Liao, S., & Wang, G. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.109 · Cited by 75
Facile and cost-effective CuS dendrite electrode for non-enzymatic glucose sensor
Kim, W. B., Lee, S. H., Cho, M., & Lee, Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.04.089 · Cited by 73
Foroughi, F., Rahsepar, M., Hadianfard, M. J., & Kim, H. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2558-8 · Cited by 67
Glucose Sensing by Fluorescent Nanomaterials
Mello, G. P. C., Simões, E. F. C., Crista, D. M. A., Leitão, J. M. M., da Silva, L. P., & da Silva, J. C. G. E. (2019) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2019.1565984 · Cited by 64
Non-enzymatic flexible glucose sensing platform based on nanostructured TiO2 – Au composite
Grochowska, K., Ryl, J., Karczewski, J. L., Śliwiński, G., Cenian, A., & Siuzdak, K. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.02.040 · Cited by 62
Continuous Blood Glucose Monitoring with a Thin-Film Optical Sensor
Worsley, G. J., Tourniaire, G., Medlock, K. E. S., Sartain, F. K., Harmer, H. E., Thatcher, M., Horgan, A. M., & Pritchard, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.091629 · Cited by 61
Mei, H., Wu, W., Yu, B., Li, Y., Wu, H., Wang, S., & Xia, Q. (2015) · Microchimica Acta · doi:10.1007/s00604-015-1524-6 · Cited by 56
Lopa, N. S., Rahman, M. M., Ahmed, F., Ryu, T., Jin, L., Choi, I., Kim, D. H., Lee, Y. H., & Kim, W. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.03.081 · Cited by 56
Self-citationMOMSense: Metal-Oxide-Metal Elementary Glucose Sensor
Abunahla, H., Mohammad, B. S., Alazzam, A., Jaoudé, M. A., Al‐Qutayri, M., Hadi, S. A., & Al-Sarawi, S. F. (2019) · Scientific Reports · doi:10.1038/s41598-019-41892-w · Cited by 55
Li, D., Wu, J., Wu, P., Lin, Y., Sun, Y., Zhu, R., Yang, J., & Xu, K. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.02.039 · Cited by 50
Nallal, M., Gopalan, A., & Lee, K.-P. (2018) · RSC Advances · doi:10.1039/c7ra09097h · Cited by 49
Gold Nanoparticle-Decorated Diatom Biosilica: A Favorable Catalyst for the Oxidation of d -Glucose
Fischer, C., Adam, M., Koball, A., Sperling, E., Wustmann, M., PÉE, K.-H. V., Kaskel, S., & Brunner, E. (2016) · ACS Omega · doi:10.1021/acsomega.6b00406 · Cited by 45
Nonenzymatic electrochemical detection of glucose based on Pd1Pt3–graphene nanomaterials
Zhang, H., Xu, X., Yin, Y., Wu, P., & Cai, C. (2012) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2012.12.001 · Cited by 38
Li, Z., Wu, G., Cai, Z., Zhao, T., Yao, Q., & Chen, X. (2015) · Microchimica Acta · doi:10.1007/s00604-015-1555-z · Cited by 35
Wu, Y., Wu, Z., & Lee, C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.042 · Cited by 34
Bell, C., Nammari, A., Uttamchandani, P., Rai, A., Shah, P., & Moore, A. L. (2017) · Nanotechnology · doi:10.1088/1361-6528/aa7164 · Cited by 33
Bajgrowicz-Cieslak, M., Alqurashi, Y., Elshereif, M. I., Yetisen, A. K., Hassan, M. U., & Butt, H. (2017) · RSC Advances · doi:10.1039/c7ra11184c · Cited by 32
He, F., Qiao, Z., Qin, X., Chao, L., Tan, Y., Xie, Q., & Yao, S. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126679 · Cited by 31
Simultaneous use of multiple fluorescent reporter dyes for glucose sensing in aqueous solution
Cordes, D. B., Miller, A., Gamsey, S., & Singaram, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1128-z · Cited by 29
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
Olejnik, A., Siuzdak, K., Karczewski, J. L., & Grochowska, K. (2019) · Electroanalysis · doi:10.1002/elan.201900455 · Cited by 29
Gao, F., Zhou, F., Yao, Y., Zhang, Y., Du, L., Geng, D., & Wang, P. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.09.036 · Cited by 28
Jiang, D., Liu, Z., Wu, K., Mou, L., Ovalle‐Robles, R., Inoue, K., Zhang, Y., Yuan, N., Ding, J., Qiu, J., et al. (2018) · Polymers · doi:10.3390/polym10040375 · Cited by 17
Oxygen Gas Assisted Laser Deposition of Gold Thin Films: Electrooxidation of Glucose
Gougis, M., Pereira, A. B., Ma, D., & Mohamedi, M. (2014) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)08033-1 · Cited by 16
Mei, H., Sheng, Q., Wu, H., Zhang, X., Wang, S., & Xia, Q. (2015) · Microchimica Acta · doi:10.1007/s00604-015-1580-y · Cited by 12
Noninvasive blood glucose detection using a miniature wearable Raman spectroscopy system
Zheng, Y., Zhu, X., Wang, Z., et al. (2017) · Chinese Optics Letters · doi:10.3788/col201715.083001 · Cited by 12
Electrochemical Sensors for Measurement of Glucose in Tiny Volumes of Tear Fluid
Meyerhoff, M. E., Cha, K. H., Qin, Y., Cohan, B. C., Balijepalli, A. S., & Jensen, G. C. (2014) · ECS Meeting Abstracts · doi:10.1149/ma2014-01/26/1107 · Cited by 2
Research works printed but not linked: 14
- Ansari, 2019, Conducting poly(aniline blue)-gold nanoparticles composite modified fluorine-doped tin oxide electrode for sensitive and non-enzymatic electrochemical detection of glucose., J. Electroanal. Chem., 850, 113394, 10.1016/j.jelechem.2019.113394 · doi:10.1016/j.jelechem.2019.113394
- Branagan, 2019, Electrochemical detection of glucose at physiological pH using gold nanoparticles deposited on carbon nanotubes, Sensor. Actuator. B Chem., 282, 490, 10.1016/j.snb.2018.11.089 · doi:10.1016/j.snb.2018.11.089
- Cordes, 2005, Optical glucose detection across the visible spectrum using anionic fluorescent dyes and a viologen quencher in a two-component saccharide sensing system, Org. Biomol. Chem., 3, 1708, 10.1039/b418953a · doi:10.1039/b418953a
- Krishna, 2016, Carbon dot based non enzymatic approach for the detection and estimation of glucose in blood serum, Mater. Res. Express, 3, 10.1088/2053-1591/3/5/055001 · doi:10.1088/2053-1591/3/5/055001
- Li, 2014, One-pot ionic liquid-assisted synthesis of highly dispersed PtPd nanoparticles/reduced graphene oxide composites for nonenzymatic glucose detection, Biosens. Bioelectron., 56, 223, 10.1016/j.bios.2014.01.030 · doi:10.1016/j.bios.2014.01.030
- Lopa, 2018, A base-stable metal-organic framework for sensitive and non-enzymatic electrochemical detection of hydrogen peroxide, Electrochim. Acta, 274, 49, 10.1016/j.electacta.2018.03.148 · doi:10.1016/j.electacta.2018.03.148
- Mai, 2019, Non-enzymatic fluorescent glucose sensor using vertically aligned ZnO nanotubes grown by a one-step, seedless hydrothermal method, Microchim. Acta, 186, 245, 10.1007/s00604-019-3353-5 · doi:10.1007/s00604-019-3353-5
- Mitsou, 2017, Oxidation catalysis by enzymes in microemulsions, Catalysts, 7, 52, 10.3390/catal7020052 · doi:10.3390/catal7020052
- Rauf, 2016, Nano-engineered biomimetic optical sensors for glucose monitoring in diabetes, Sensors, 10.3390/s16111931 · doi:10.3390/s16111931
- Sato, 2001, Electrochemical glucose sensors and their applications in diabetes management, Chem. Rev., 108, 2482
- Wang, 2018, An alkaline and surfactant-tolerant lipase from Trichoderma lentiforme ACCC30425 with high application potential in the detergent industry, Amb. Express, 8, 95, 10.1186/s13568-018-0618-z · doi:10.1186/s13568-018-0618-z
- Wang, 2012, Optical probe for d-glucose based on cationic polymer quencher/receptor and anionic dye in aqueous solution, Sensor. Actuator. B Chem., 163, 202, 10.1016/j.snb.2012.01.036 · doi:10.1016/j.snb.2012.01.036
- Wu, 2018, Facile preparation of PtNPs/BSA-RGO nanostructure for non-enzymatic glucose electrochemical sensing, Int. J. Electrochem. Sci., 13, 9784, 10.20964/2018.10.50 · doi:10.20964/2018.10.50
- Zang, 2018, Copper nanowires-MOFs-graphene oxide hybrid nanocomposite targeting glucose electro-oxidation in neutral medium, Electrochim. Acta, 277, 176, 10.1016/j.electacta.2018.05.016 · doi:10.1016/j.electacta.2018.05.016
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
“Studies on the improvement of new non-invasive monitoring systems are likely to continue to grow [4,10,13,14].”
BackgroundChen, M., Cao, X., Chang, K., Xiang, H., & Wang, R. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137603 · Cited by 65
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
Metadata
- Authors
- Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 165
- Pages
- 112331
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3032779279
- Cited by
- 327
- References
- 116
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Università Ca' Foscari di Venezia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.