The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Short trains of transcutaneous auricular vagus nerve stimulation (taVNS) have parameter-specific effects on heart rate
Open accessAbstract
Background: Optimal parameters of transcutaneous auricular vagus nerve stimulation (taVNS) are still undetermined. Given the vagus nerve’s role in regulating heart rate (HR), it is important to determine safety and HR effects of various taVNS parameters. Objective: We conducted two sequential trials to systematically test the effects of various taVNS parameters on HR. Methods: 15 healthy individuals participated in the initial two-visit, crossover exploratory trial, receiving either tragus (active) or earlobe (control) stimulation each visit. Nine stimulation blocks of varying parameters (pulse width: 100 μs, 200 μs, 500 μs; frequency: 1 Hz, 10 Hz, 25 Hz) were administered each visit. HR was recorded and analyzed for stimulation-induced changes. Using similar methods and the two best parameters from trial 1 (500μs 10 Hz and 500μs 25 Hz), 20 healthy individuals then participated in a follow-up confirmatory study. Results: Trial 1- There was no overall effect of the nine conditions on HR during stimulation. However multivariate analysis revealed two parameters that significantly decreased HR during active stimulation compared to control (500μs 10 Hz and 500μs 25 Hz; p < 0.01). Additionally, active taVNS significantly attenuated overall sympathetic HR rebound (post-stimulation) compared to control (p < 0.001). Trial 2- For these two conditions, active taVNS significantly decreased HR compared to control (p = 0.02), with the strongest effects at 500μs 10 Hz (p = 0.032). Conclusion: These studies suggest that 60s blocks of tragus stimulation are safe, and some specific parameters modulate HR. Of the nine parameters studied, 500μs 10 Hz induced the greatest HR effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hawker, G. A., Mian, S., Kendzerska, T., & French, M. (2011) · Arthritis Care & Research · doi:10.1002/acr.20543 · Cited by 4,924
Physiology and immunology of the cholinergic antiinflammatory pathway
Tracey, K. J. (2007) · Journal of Clinical Investigation · doi:10.1172/jci30555 · Cited by 1,563 · cited 1×
“The vagus nerve (CN X) is a mixed sensory and motor nerve that has efferent projections travelling throughout the abdomen, targeting nearly every major organ and is highly involved in the parasympathetic nervous system [1,2].”
BackgroundThe Central Autonomic Network: Functional Organization, Dysfunction, and Perspective
BENARROCH, E. E. (1993) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)62272-1 · Cited by 1,534
Ben‐Menachem, E., Mañon‐Espaillat, R., Ristanovic, R., Wilder, B. J., Stefan, H., Mirza, W., Tarver, W. B., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02482.x · Cited by 683
Prospective Long‐Term Study of Vagus Nerve Stimulation for the Treatment of Refractory Seizures
DeGiorgio, C. M., Schachter, S. C., Handforth, A., Salinsky, M., Thompson, J., Uthman, B., Reed, R., Collin, S., Tecoma, E., Morris, G. L., et al. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb00325.x · Cited by 479
Premchand, R. K., Sharma, K., Mittal, S., Monteiro, R., Dixit, S., Libbus, I., DiCarlo, L. A., Ardell, J. L., Rector, T. S., Amurthur, B., et al. (2014) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2014.08.009 · Cited by 377
The yin and yang of cardiac autonomic control: Vago-sympathetic interactions revisited
Paton, J. F. R., Boscan, P., Pickering, A. E., & Nalivaiko, E. (2005) · Brain Research Reviews · doi:10.1016/j.brainresrev.2005.02.005 · Cited by 308
Lim, S., Anantharaman, V, Teo, W., Goh, P., & Tan, A. (1998) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(98)70277-x · Cited by 176
Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78
Cited by
The anatomical basis for transcutaneous auricular vagus nerve stimulation
Butt, M. F., Albusoda, A., Farmer, A. D., & Aziz, Q. (2020) · Journal of Anatomy · doi:10.1111/joa.13122 · Cited by 603
Farmer, A. D., Strzelczyk, A., Finisguerra, A., Gourine, A. V., Gharabaghi, A., Hasan, A., Burger, A. M., Jaramillo, A. M., Mertens, A., Majid, A., et al. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.568051 · Cited by 355
Self-citationCurrent Directions in the Auricular Vagus Nerve Stimulation I – A Physiological Perspective
Kaniusas, E., Kampusch, S., Tittgemeyer, M., Panetsos, F., Gines, R. F., Papa, M., Kiss, A., Podesser, B., Cassara, A. M., Tanghe, E., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00854 · Cited by 323
Dolphin, H., Dukelow, T., Finucane, C., Commins, S., McElwaine, P., & Kennelly, S. P. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.897303 · Cited by 38
Metadata
- Authors
- Badran, B. W., Mithoefer, O. J., Summer, C. E., LaBate, N. T., Glusman, C. E., Badran, A. W., DeVries, W. H., Summers, P. M., Austelle, C. W., McTeague, L. M., Borckardt, J. J., & George, M. S.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 11
- Issue
- 4
- Pages
- 699-708
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2796093625
- Cited by
- 194
- References
- 9
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short trains of transcutaneous auricular vagus nerve stimulation (taVNS) have parameter-specific effects on heart rate. https://app.cochat.ai/papers/10.1016/j.brs.2018.04.004
- The paper
- Badran, B. W., Mithoefer, O. J., Summer, C. E., LaBate, N. T., Glusman, C. E., Badran, A. W., DeVries, W. H., Summers, P. M., Austelle, C. W., McTeague, L. M., Borckardt, J. J., & George, M. S. (2018). Short trains of transcutaneous auricular vagus nerve stimulation (taVNS) have parameter-specific effects on heart rate. Brain Stimulation. https://doi.org/10.1016/j.brs.2018.04.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.